Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Approaches to Quantify Potential Contaminant Transport in the Lower Carbonate Aquifer from Underground Nuclear Testing at Yucca Flat, Nevada National Security Site, Nye County, Nevada - 12434

Quantitative modeling of the potential for contaminant transport from sources associated with underground nuclear testing at Yucca Flat is an important part of the strategy to develop closure plans for the residual contamination. At Yucca Flat, the most significant groundwater resource that could potentially be impacted is the Lower Carbonate Aquifer (LCA), a regionally extensive aquifer that supplies a significant portion of the water demand at the Nevada National Security Site, formerly the Nevada Test Site. Developing and testing reasonable models of groundwater flow in this aquifer is an important precursor to performing subsequent contaminant transport modeling used to forecast contaminant boundaries at Yucca Flat that are used to identify potential use restriction and regulatory boundaries. A model of groundwater flow in the LCA at Yucca Flat has been developed. Uncertainty in this model, as well as other transport and source uncertainties, is being evaluated as part of the Underground Testing Area closure process. Several alternative flow models of the LCA in the Yucca Flat/Climax Mine CAU have been developed. These flow models are used in conjunction with contaminant transport models and source term models and models of contaminant transport from underground nuclear tests conducted in the overlying unsaturated and saturated alluvial and volcanic tuff rocks to evaluate possible contaminant migration in the LCA for the next 1,000 years. Assuming the flow and transport models are found adequate by NNSA/NSO and NDEP, the models will undergo a peer review. If the model is approved by NNSA/NSO and NDEP, it will be used to identify use restriction and regulatory boundaries at the start of the Corrective Action Decision Document Corrective Action Plan (CADD/CAP) phase of the Corrective Action Strategy. These initial boundaries may be revised at the time of the Closure Report phase of the Corrective Action Strategy. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cell structure in cold worked and creep deformed phosphorus alloyed copper

Transmission electron microscopy (TEM) examinations on as-received, cold worked, as well as cold worked and creep tested phosphorus-alloyed oxygen-free copper (Cu-OFP) have been carried out to study the role of the cell structure. The cell size decreased linearly with increasing plastic deformation in tension. The flow stress in the tests could also be correlated to the cell size. The observed relation between the flow stress and the cell size was in excellent agreement with previously published results. The dense dislocation walls that appeared after cold work in tension is likely to be the main reason for the dramatic increase in creep strength. The dense dislocation walls act as barriers against dislocation motion and their presence also reduces the recovery rate due to an unbalanced dislocation content.

36 MATERIALS SCIENCE↗

Study of implosion dynamics, the x-ray yield and plasma interpenetration in star wire arrays with gates in the inner cylinder.

Star wire arrays with two closely located wires ('gates') on the inner cylinder of star wire arrays were studied. The gate wires were used to study plasma interpenetration and reproduce transparent and non-transparent regimes of propagation of the imploding plasma through the gates. The non-transparent mode of collision is typical for regular star wire arrays and it was also observed in Al stars with gate wires of regular length. Gated star arrays demonstrate similar x-ray yield but slightly different delay of x-ray generation compared to regular stars. Double length wires were applied as gate wires to increase their inductance and resistance and to increase transparency for the imploding plasma. The wires of the gates were made of Al or high atomic number elements, while the rest of the arrays were regular length Al wires. An intermediate semi-transparent mode of collision was observed in Al stars with long Al gate wires. Arrays with long heavy-element gate wires demonstrated transparency to plasma passing through. Shadowgraphy at the wavelength of 266 nm showed that plasma moved through the gate wires. Double implosions, generating a double-peak keV X-ray pulse, were observed in star arrays when the gates were made of high atomic number elements. A new laser diagnostic beampath for vertical probing of the Z-pinch was built to test how wires could be used to redirect plasma flow. This setup was designed to test gated arrays and further configurations to create a rotating pinch. Results on plasma flow control obtained are discussed, and compared to numerical calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vadose and Saturated Zone Flow and Transport Model Package Report for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

This model package report (MPR) documents the development of the integrated vadose and saturated zone flow and transport model developed for the performance assessment of Trenches 31 and 34 in the low-level burial grounds (LLBGs). This modeling capability is intended for use in addressing the analysis requirements outlined in DOE O 435.1, Chg 1, Radioactive Waste Management1. The overall objective of the modeling effort is to provide a basis for making informed disposal decisions pertinent to Trenches 31 and 34. The purpose of the MPR is to document the development of the three-dimensional numerical vadose zone and saturated flow and transport model test case and evaluate its adequacy to support the LLBG performance assessment. The purpose is not to present results for DOE 435.1 decision making. The use of the model to perform base case and sensitivity analysis for the LLBG performance assessment, including inputs and results, is documented separately in subsequent environmental calculation files. This report discusses the development and translation of the conceptual model for flow and contaminant transport into the LLBG performance assessment three-dimensional numerical flow and transport model evaluated using the Subsurface Transport Over Multiple Phases (STOMP©) simulator. The development of representative geologic framework is described along with the implementation of waste release models used to represent contaminant release from waste disposed in the trenches. The report also provides the technical basis for specific model parameters and boundary conditions, along with description of modeling assumptions. This MPR includes certain calculations that are necessary to demonstrate the soundness of the model. Results provided by the model include vadose zone and saturated zone flow fields, and estimates of the possible future concentration in groundwater of technetium-99 and iodine-129 as example test cases. As an evaluation of the test cases, the model estimates of current vadose conditions are compared to available and analogous field and laboratory data, and compared to the results from the original performance assessment model (WHC-EP-0645, Performance Assessment for the Disposal of Low-Level Waste in the 200 West Area Burial Grounds 2 ). The features, events, and processes applicable to vadose zone and saturated zone flow and transport model are identified, and representative initial estimates for various parameters are documented. Note that the parameter estimates presented in this MPR are for illustration purposes, and may or may not reflect values selected for eventual performance assessment. Several key topical discussions (i.e., basis for recharge estimates, basis for vadose zone modeling, basis for saturated zone model development, and calibration) are included, which serve as the groundwork for confidence building for the groundwater pathway modeling and results. Numerical simulation results based on an example test case are included to illustrate the use of the combined saturated-unsaturated model in performance assessment calculations. Sensitivity and uncertainty results are not included in this MPR. Those results will be included in future environmental calculation files. The inclusion of the trapezoidal trench geometry and construction details in the finite difference grid introduces some gross simplifications regarding the trench and liner systems. The model test case presented in this MPR includes the assumption that the trench liner system does not affect flow through or around the trenches after the liner system is assumed to fail. This MPR also includes results of other test cases that involve alternate assumptions about how to incorporate the hydraulic effects of the trenches into the vadose zone of the model. These alternate cases do not attempt to account for the presence of the liner system after its assumed failure either. None of these cases is considered to be the base case at this time. Analysis and alternate cases that attempt to account for the presence of the liner system in greater detail, and its effect on flow through and around it, are to be documented in subsequent environmental calculation files. Depending on the results of those analyses and alternate cases, the eventual base case may involve more detailed inclusion of the effects of the liner system hydraulics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dispenser Reliability: Materials R&D. A Hydrogen Fueling Infrastructure Research and Station Technology (H2FIRST) Report

Dispensers are the top cause of maintenance events and down-time at hydrogen fueling stations. In an effort to help characterize and enable improvements in dispenser reliability, an extensive accelerated lifetime testing set-up was designed and built at NREL involving components typically part of dispensing operations at fueling stations. Device Under Test (DUTs) included different components such as normally open valves, normally closed valves, fueling nozzles, breakaways devices and filters. Conditions of testing included pressures, and flow rates similar to light duty fuel cell electric vehicles fueling at -40°C, and -20°C for thousands of cycles in hydrogen. Tested components (failed and non-failed) were disassembled at SNL and polymeric O-rings were carefully retrieved and cataloged for chemical and physical characterization. Data collected was compared to similar O-rings from unexposed or non-tested components for hydrogen effects, and failure modes. Degradation analyses, based on select polymer chemistries common across all component types, their location within components, visual assessment of damage coupled with strong hydrogen effects from chemical characterization, was completed and presented to NREL and DOE. Overall, the failure rate amongst the components was not as high as expected for the test conditions. Among the component types tested, breakaways were the most susceptible to damage under these test conditions, with fueling nozzles a close second. The proper combination of selection of the right polymer and optimum component design was found to make a strong difference in component reliability under severe dispenser operating conditions. Physical degradation of polymers, rather than chemical changes due to low temperature hydrogen exposure, is more prevalent as failure mode for these test conditions. The nature and the extent of the degradation was much less at -20°C as compared to -40°C. The damage and failure rates were higher at lower temperatures than at higher test temperatures. As expected, increasing the number of cycles at the lowest test temperature (-40°C) increased damage. This indicates that cycling at the low temperature of -40°C required by SAE J2601 can reduce component life in fuel dispensing operations

08 HYDROGEN↗

Electromagnetic zonal flow residual responses

The collisionless axisymmetric zonal flow residual calculation for a tokamak plasma is generalized to include electromagnetic perturbations. We formulate and solve the complete initial value zonal flow problem by retaining the fully self-consistent axisymmetric spatial perturbations in the electric and magnetic fields. Simple expressions for the electromagnetic test of the zonal flow residual in gyrokinetic codes. Unlike the electrostatic potential, the parallel vector potential and the parallel magnetic field perturbations need not relax to flux functions for all possible initial conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Blind Modeling Validation Exercises Using the Horizontal Dry Cask Simulator

The U.S. Department of Energy (DOE) established a need to understand the thermal-hydraulic properties of dry storage systems for commercial spent nuclear fuel (SNF) in response to a shift towards the storage of high-burnup (HBU) fuel (> 45 gigawatt days per metric ton of uranium, or GWd/MTU). This shift raises concerns regarding cladding integrity, which faces increased risk at the higher temperatures within spent fuel assemblies present within HBU fuel compared to low-burnup fuel (≤ 45 GWd/MTU). A dry cask simulator (DCS) was built at Sandia National Laboratories (SNL) in Albuquerque, New Mexico to produce validation-quality data that can be used to test the accuracy of the modeling used to predict cladding temperatures. These temperatures are critical to evaluating cladding integrity throughout the storage cycle of commercial spent nuclear fuel. A model validation exercise was previously carried out for the DCS in a vertical configuration. Lessons learned during the previous validation exercise have been applied to a new, blind study using a horizontal dry cask simulator (HDCS). Three modeling institutions – the Nuclear Regulatory Commission (NRC), Pacific Northwest National Laboratory (PNNL), and Empresa Nacional del Uranio, S.A., S.M.E. (ENUSA) – were granted access to the input parameters from the DCS Handbook, SAND2017-13058R, and results from a limited data set from the horizontal BWR dry cask simulator tests reported in the HDCS update report, SAND2019-11688R. With this information, each institution was tasked to calculate peak cladding temperatures and air mass flow rates for ten HDCS test cases. Axial as well as vertical and horizontal transverse temperature profiles were also calculated. These calculations were done using modeling codes (ANSYS/Fluent, STAR-CCM+, or COBRA-SFS), each with their own unique combination of modeling assumptions and boundary conditions. For this validation study, the ten test cases of the horizontal dry cask simulator were defined by three independent variables – fuel assembly decay heat (0.5 kW, 1 kW, 2.5 W, and 5 kW), internal backfill pressure (100 kPa and 800 kPa), and backfill gas (helium and air). The plots provided in Chapter 3 of this report show the axial, vertical, and horizontal temperature profiles obtained from the dry cask simulator experiments in the horizontal configuration and the corresponding models used to describe the thermal-hydraulic behavior of this system. The tables provided in Chapter 3 illustrate the closeness of fit of the model data to the experiment data through root mean square (RMS) calculations of the error in peak cladding temperatures (PCTs), PCT axial locations, axial temperature profiles, vertical and horizontal temperature profiles at two different axial locations, and air mass flow rates for the ten test cases, normalized by the experimental results. The model results are assigned arbitrary model numbers to retain anonymity. Due to the relatively flat axial temperature profiles, small temperature gradients resulted in large deviations of all models’ PCT axial location from the experimental PCT axial location. When the PCT axial location error is excluded in the calculation of the combined RMS of the normalized errors that considers PCT, the temperature profiles, and the air mass flow rates, the model data fits the experimental data to within 5%. When the vault information is excluded, the model data fits the experimental data to within 2.5%. An error analysis was developed further for one model, using the model and experimental uncertainties in each validation parameter to calculate validation uncertainties. The uncertainties for each parameter were used to define quantifiable validation criteria. For this analysis, the model was considered validated for a given comparison metric if the normalized error in that metric divided by the validation uncertainty was less than or equal to 1. When considering the combined RMS of the normalized errors of all metrics divided by their validation uncertainties, the model was found to have satisfied the criterion for model validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification and Validation of a Modified Numerical Algorithm for Simulation of Transient Unconfined Groundwater Flow

This report extends verification and validation testing of the NUFT package of codes (Nitao 2000a,b) to the US1P module of code designed for simulation of single-phase mixed or “coupled” saturated and unsaturated (or “variably saturated”) groundwater flow. Importantly, the verification and validation testing of US1P in this report includes performance evaluation of a modified numerical algorithm that was not included in prior quality assurance (QA) of the NUFT package by Carle et al. (2014) for Underground Test Area (UGTA) project activities, which are directed at assessment of radionuclide contamination in groundwater sourced from underground nuclear test locations at the Nevada National Security Site (NNSS). An immediate purpose of this report is to provide QA for ongoing large-scale, three-dimensional (3-D) groundwater flow modeling of transient water levels associated with longterm water supply pumping and underground nuclear testing at the NNSS (Jackson and Fenelon, 2018; Jackson et al., 2021). For UGTA activities, the QA refers to the standards of ASTM (1996) for verification and validation testing of groundwater modeling codes.

54 ENVIRONMENTAL SCIENCES↗

Enhanced flow boiling heat transfer on chromium coated zircaloy-4 using cold spray technique for accident tolerant fuel (ATF) materials

Flow boiling heat transfer tests were conducted to evaluate the Critical Heat Flux (CHF) and Heat Transfer Coefficient (HTC) of conventional and accident tolerant fuel (ATF) cladding materials, i.e., bare Zircaloy-4 (Zr4), and Zircaloy-4 coated with Chromium using physical vapor deposition (PVD) (Zr4-Cr-PVD) and cold spray process (Zr4-Cr-CS), respectively. The tests were performed on a single heater rod with a uniform heat flux profile, at the atmospheric pressure, inlet temperature (24 °C) and mass flow rate (750 kg/m 2 s). HTC’s were increased by 5.2% and 3.3% on Zr4-Cr-CS compared to bare Zr4 and Zr4-Cr-PVD. Improved HTCwas attributed to the increased void fraction and high roughness (Ra = 532 nm) of the Zr4-Cr-CS. In detail, the micro-cavities, which act as bubble seeds, were entirely distributed on the Zr4-Cr-CS, and these micro-cavities generated smaller and faster bubbles, thus the void fraction increased by 10.9% compared to bare Zr4. HTC is improved by these smaller and faster bubbles which can remove heat from the heater rod surface more efficiently. To identify the exact location of CHF, the surface temperature profile was measured using advanced fiber-optic sensors which have high temporal/spatial resolution (distance between point to point: ~2.5 mm, frequency ~100 Hz). CHF occurred at 80–95% along the heated length and showed an 11.6% reduction on Zr4-Cr-CS compared to bare Zr4. We hypothesize the CHF reduction was caused by the lower wettability of the Zr4-Cr-CS which reduces the liquid supply to the surface, and vigorous bubble accumulation owing to high void fraction near the outlet, which results in early formation of the vapor film. During the post-CHF quenching phase, the rougher Zr4-Cr-CS showed larger cooling rates compared to the bare Zr4 and Zr4-Cr-PVD, preventing of oxidation by chromium layer. In conclusion, we demonstrate that the high roughness on the Zr4-Cr-CS increased the number of micro-cavities on the surface, resulting in 5.2% increase in HTC and improvement in the quenching heat transfer performance whereas CHF was 11.6% reduced compared to bare Zr4. Overall statistically there is little effect in the coating with regards to CHF and slight improvement in HTC.

42 ENGINEERING↗

Development of Ce-type FeCrAl-ODS ferritic steel to accident tolerant fuel for BWRs

A Ce-type FeCrAl-ODS ferritic steel has been examined as a candidate Fe-Cr-Al alloy for the fuel cladding in BWRs. The properties examined in this study were the corrosion resistance to coolant water, the resistance to the high temperature steam and the interactions with neighboring materials (UO{sub 2} and B{sub 4}C). For the corrosion test, the specimens were corroded in an autoclave with circulating pure water at 633 K and a pressure of approximately 20 MPa. In addition to the Ce-ODS, MA956 and SS316L alloys were also corroded as reference materials. For the steam oxidation test, the specimens were oxidized in an electric furnace at 1473 K for 100 h and 1573 K for 25 h under wet Ar gas flow. The materials reaction test with B{sub 4}C was carried out at 1573 K and 1673 K for 1 h. The test with UO{sub 2} was performed in a high purity He gas at 1573 K and 1673 K for 1 h. A disk of UO{sub 2} pellet was set on the Ce-ODS specimen and the reaction couple was held in the pure Zr box to prevent a surface oxidation by residual oxidizing gases. The cross sections of reaction couples were observed by an optical microscope (OM) and a secondary electron microscope (SEM) with energy-dispersive spectroscope (EDS) after the materials interaction tests. The results show that the Ce-type FeCrAl-ODS steel has demonstrated a good corrosion resistance to coolant water and high accident tolerances in the oxidation with high temperature steam and in the interactions with neighboring materials. Those favorable properties would imply that the oxide dispersion strengthened (ODS) technology can be a candidate option for further development of accident-tolerant fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NETL Direct Air Capture Center

In 2022 Congress authorized the $25M National Energy Technology Laboratory Direct Air Capture Center. The facility will be specifically targeted at accelerating the commercialization of technologies beyond the conceptual stage which have not yet reached full pilot-scale (TRL 3 to 6). The ability to operate over a wide range of conditions will help the developers to understand how their technologies respond in different climates, from summer to winter and arid to tropical. NETL recognizes that DAC technology is still early in its evolution, and a wide variety of highly varied technologies are being explored. The Center will be designed with substantial flexibility to accommodate the rapidly evolving technological landscape. Testing systems at three scales will be included: lab-scale systems designed to examine the long-term stability of DAC materials, bench-scale module testing systems capable of probing flow dynamics, and small pilot-scale skid rooms able to test prototype DAC units under a wide variety of climate conditions. The NETL DAC Center will feature dedicated engineering, technician, scientific and logistical support for experimental system design, installation, operation of experiments, and interpretation of results for projects including but not limited to kinetics of absorption/desorption, thermal duty, and post-mortem elemental characterization to understand degradation. The NETL DAC Center projects will also have access to dedicated process modeling and analysis to evaluate the technoeconomic aspects of new technologies. NETL’s Systems Engineering and Analysis (SEA) team, the Carbon Capture Simulation Initiative (CCSI), and the Institute for the Design of Advanced Energy Systems (IDAES) are all potential collaborators with NETL’s testing partners from industry, academia, and other research institutions. NETL also has world class capabilities in device scale modeling (i.e., MFIX) that will be available to help design more efficient contactors and optimize unique internal configurations that can be realized by advanced manufacturing. The talk will cover the design and capabilities of the center, the planned availability, and feedback will be solicited from the audience on DAC testing needs.

Luebke, David↗

Accelerating commercialization of direct air capture technology

In 2022 Congress authorized the $25M National Energy Technology Laboratory Direct Air Capture Center. The facility will be specifically targeted at accelerating the commercialization of technologies beyond the conceptual stage which have not yet reached full pilot-scale (TRL 3 to 6). The ability to operate over a wide range of conditions will help the developers to understand how their technologies respond in different climates, from summer to winter and arid to tropical. NETL recognizes that DAC technology is still early in its evolution, and a wide variety of highly varied technologies are being explored. The Center will be designed with substantial flexibility to accommodate the rapidly evolving technological landscape. Testing systems at three scales will be included: lab-scale systems designed to examine the long-term stability of DAC materials, bench-scale module testing systems capable of probing flow dynamics, and small pilot-scale skid rooms able to test prototype DAC units under a wide variety of climate conditions. The NETL DAC Center will feature dedicated engineering, technician, scientific and logistical support for experimental system design, installation, operation of experiments, and interpretation of results for projects including but not limited to kinetics of absorption/desorption, thermal duty, and post-mortem elemental characterization to understand degradation. The NETL DAC Center projects will also have access to dedicated process modeling and analysis to evaluate the technoeconomic aspects of new technologies. NETL’s Systems Engineering and Analysis (SEA) team, the Carbon Capture Simulation Initiative (CCSI), and the Institute for the Design of Advanced Energy Systems (IDAES) are all potential collaborators with NETL’s testing partners from industry, academia, and other research institutions. NETL also has world class capabilities in device scale modeling (i.e., MFIX) that will be available to help design more efficient contactors and optimize unique internal configurations that can be realized by advanced manufacturing. The talk will cover the design and capabilities of the center, the planned availability, and feedback will be solicited from the audience on DAC testing needs.

Luebke, David↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Impact of Brine/CO 2 exposure on the transport and mechanical properties of the Mt Simon sandstone

When sandstone rocks are exposed to CO 2 -saturated brine, their transport and mechanical properties can change due to brine/CO 2 -induced chemical reactions. The present study investigates the change in the flow-through characteristics, porosity, and the mechanical behavior of Mt. Simon Sandstone samples caused by exposure to brine/CO 2 . The cores, extracted from a depth interval of 2110.4–2111.4 m (6924–6927 ft) in the Mt. Simon formation, were first characterized for their mechanical and transport properties, and then aged in CO 2 -saturated brine at pressures of 17.24 MPa (2500 psi) and temperature of 50°C for one to two weeks. Following that, the changes in the transport and mechanical properties of the samples were analyzed using He pycnometry, flow perporometry and triaxial testing. Our experiments show that the porosity of the Mt. Simon samples slightly increases after exposure to CO 2 /brine, while the permeability increases more substantially depending on the stress state. Measurements of the flow-through pore size distribution (PSD) are indicative of the changes occurring and are consistent with the observed increases in permeability. Nitrogen adsorption tests (BET), before and after incubation, show a significant loss of pore volume in the mesoporous range that is indicative of clay dissolution. Weakening of the materials was observed based on the mechanical properties studied, a result that is consistent with the observed dissolution of clays that play a central role in the cementation of the quartz grains. Finally, the analysis of the brine compositions reveals an increase in concentration of most cations after incubation with the Mt. Simon cores. This is also consistent with mineral/clay dissolution, confirmed by the porosity, transport, and mechanical property measurements as well as electron microscopy analysis of the same samples.

58 GEOSCIENCES↗

Experimental and Measurement Uncertainty Associated with Characterizing Slurry Mixing Performance of Pulsating Jets at Multiple Scales

Understanding how uncertainty manifests itself in complex experiments is important for developing the testing protocol and interpreting the experimental results. This paper describes experimental and measurement uncertainties, and how they can depend on the order of performing experimental tests. Experiments with pulse-jet mixers in tanks at three scales were conducted to characterize the performance of transient-developing periodic flows in Newtonian slurries. Other test parameters included the simulant, solids concentration, and nozzle exit velocity. Critical suspension velocity and cloud height were the metrics used to characterize Newtonian slurry flow associated with mobilization and mixing. During testing, near-replicate and near-repeat tests were conducted. The experimental results were used to quantify the combined experimental and measurement uncertainties using standard deviations and percent relative standard deviations (%RSD) The uncertainties in critical suspension velocity and cloud height tend to increase with the values of these responses. Hence, the %RSD values are the more appropriate summary measure of near-replicate testing and measurement uncertainty.

pulse jet mixing↗

Helium Leak Test Data for System Evaluation

The test data in the flowing pages below has been created to ensure the maintenance conducted on the current MSHLD systems is satisfactory per ASNT Level III review. This is diagnostic test data only and it is intended to be used as a reference document.

36 MATERIALS SCIENCE↗

Sequential formulation of all‐way coupled finite strain thermoporomechanics for largely deformable gas hydrate deposits

We develop a numerically stable sequential formulation of thermoporomechanics for largely deformable gas hydrate deposits, extended from the fixed stress split of infinitesimal transformation. Constitutive equations are based on the total Lagrangian approach for both flow and geomechanics, including dynamic full tensor permeability and thermal conductivity updated from the deformation gradient. For space discretization, we take the cell-centered finite volume and node-based finite element method for flow and geomechanics, respectively. Then, we propose a sequential implicit method for all-way coupled thermoporomechanics, where the nonisothermal multiphase flow problem of gas hydrates is solved implicitly first and then the geomechanics problem is solved implicitly at the next step. During solution of the flow problem, we fix the rate of first Pioal total stress for numerical stability as well as apply porosity correction and entropy correction to account for geomechanical effects. We test numerical examples where flow and geomechanics parameters are based on deep oceanic gas hydrate deposits. When applying depressurization, even though the results between the infinitesimal transformation and finite strain geomechanics are similar in the early stages due to small deformation, we find differences between them in the late times as deformation becomes large. Accordingly, permeability and thermal conductivity tensors become nonisotropic full tensors although they are initially isotropic. Furthermore, we identify numerical stability of the developed sequential method from the test cases that exhibit the highly complex coupled gas hydrate systems with large deformation. Thus, the proposed sequential formulation can be applied in largely deformable gas hydrate systems.

42 ENGINEERING↗