Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

In-duct removal of mercury from coal-fired power plant flue gas by activated carbon: assessment of entrained flow versus wall surface contributions

In-duct mercury capture efficiency by activated carbon from coal-combustion flue gas was investigated. To this end, elemental mercury capture experiments were conducted at 100 C in a purposely designed 65-mm ID labscale pyrex apparatus operated as an entrained flow reactor. Gas residence times were varied between 0.7 and 2.0 s. Commercial-powdered activated carbon was continuously injected in the reactor and both mercury concentration and carbon elutriation rate were followed at the outlet. Transient mercury concentration profiles at the outlet showed that steady-state conditions were reached in a time interval of 15-20 min, much longer than the gas residence time in the reactor. Results indicate that the influence of the walls is non-negligible in determining the residence time of fine carbon particles in the adsorption zone, because of surface deposition and/or the establishment of a fluid-dynamic boundary layer near the walls. Total mercury capture efficiencies of 20-50% were obtained with carbon injection rates in the range 0.07-0.25 g/min. However, only a fraction of this capture was attributable to free-flowing carbon particles, a significant contribution coming from activated carbon staying near the reactor walls. Entrained bed experiments at lab-scale conditions are probably not properly representative of full-scale conditions, where the influence of wall interactions is lower. Moreover, previously reported entrained flow lab-scale mercury capture data should be reconsidered by taking into account the influence of particle-wall interactions.

01 COAL, LIGNITE, AND PEAT↗

Reaction enhancement of initially distant scalars by Lagrangian coherent structures

Turbulent fluid flows have long been recognized as a superior means of diluting initial concentrations of scalars due to rapid stirring. Conversely, experiments have shown that the structures responsible for this rapid dilution can also aggregate initially distant reactive scalars and thereby greatly enhance reaction rates. Indeed, chaotic flows not only enhance dilution by shearing and stretching but also organize initially distant scalars along transiently attracting regions in the flow. To show the robustness of this phenomenon, a hierarchical set of three numerical flows is used: the periodic wake downstream of a stationary cylinder, a chaotic double gyre flow, and a chaotic, aperiodic flow consisting of interacting Taylor vortices. We demonstrate that Lagrangian coherent structures (LCS), as identified by ridges in finite time Lyapunov exponents, are directly responsible for this coalescence of reactive scalar filaments. When highly concentrated filaments coalesce, reaction rates can be orders of magnitude greater than would be predicted in a well-mixed system. This is further supported by an idealized, analytical model that was developed to quantify the competing effects of scalar dilution and coalescence. Chaotic flows, known for their ability to efficiently dilute scalars, therefore have the competing effect of organizing initially distant scalars along the LCS at timescales shorter than that required for dilution, resulting in reaction enhancement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma assisted NH 3 /H 2 /air ignition in nanosecond discharges with non-equilibrium energy transfer

Ammonia (NH 3 ), with its high energy density and easiness to store and transport as a hydrogen carrier, has become a promising alternative green fuel. However, its adoption in power generation is hindered by challenges such as low burning velocity, slow low-temperature oxidation, high NO x emissions, and ignition difficulty. Here, this work computationally investigates the effects of non-equilibrium energy transfer by nanosecond discharges on NH 3 ignition and flame propagation in an NH 3 /H 2 /air flow at 700 K and 1 atm. The simulation results demonstrate that NH 3 /air mixtures require a large ignition energy due to their large critical ignition radius. It is shown that adding 30 % hydrogen significantly reduces the critical ignition radius and minimum ignition energy. Two-dimensional modeling further shows a non-monotonic dependence of ignition kernel volume on the applied voltage and reduced electric field. The optimum ignition enhancement occurs at 200 Td where the generation of electronically excited species and radicals including N 2 (B), O( 1 D) and OH becomes most efficient. Higher voltages divert electron energy toward ionization, which makes it less effective for NH 3 ignition. The study also identifies an optimal electrode gap size for a given pulse energy. Smaller gap sizes increase deposited energy density, raising temperature and radical concentrations. However, excessive reduction of the gap distance reduces flame propagation speed due to the flame stretch effect in rich mixtures with the effective Lewis number greater than unity. A nonlinear relationship between pulse repetition frequency and ignition kernel volume is observed in a nanosecond pulsed high frequency discharge (NPHFD). An optimal frequency range of 200 kHz to 2 MHz is found when two pulses are used. In addition, an optimal number of pulses exists for each pulse repetition frequency, with higher frequencies requiring more pulses to maximize the overlap region. These findings provide critical insights on developing controlled plasma discharge techniques for efficient NH 3 ignition in reactive flows within internal combustion engines and gas turbines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermodynamic Analysis of Isothermal Redox Cycling of Ceria for Solar Fuel Production

A thermodynamic analysis of continuous fuel production by redox cycling of ceria in a single solar reactor under isothermal conditions is presented. Ceria is partially reduced in a sweep gas flow of purified nitrogen and reoxidized with either steam or carbon dioxide to produce hydrogen or carbon monoxide, respectively. The sweep gas and oxidizer flows are preheated by the product gases. The influence of selected process parameters, including operating temperature, pressure, and the effectiveness of heat recovery, on the solar-to-fuel conversion efficiency is determined. For a solar concentration ratio of 3000, typical of state-of-the-art solar dish concentrators, and operating temperature of 1773 K, 95.5% of the available gas-phase heat must be recovered to reach conversion efficiencies of 10% and 18% for hydrogen and carbon monoxide production, respectively, assuming the flow rate of inert sweep gas is equivalent to that in a counter-current flow arrangement of gas and ceria. The efficiency depends strongly on the gas-phase heat recovery effectiveness and the sweep gas flow rate. Introducing a temperature swing of 150 K between reduction and oxidation steps strongly reduces the sweep gas flow rate and increases the efficiency from 10% to 31.6% for hydrogen production.

Bader, R↗

Hydrodynamics of a multicomponent vesicle under strong confinement

Herein we numerically investigate the hydrodynamics and membrane dynamics of a multicomponent vesicle in two strongly confined geometries. This serves as a simplified model for red blood cells undergoing large deformations while traversing narrow constrictions. We propose a new parameterization for the bending modulus that remains positive for all lipid phase parameter values. For a multicomponent vesicle passing through a stenosis, we establish connections between various properties: lipid phase coarsening, size and flow profile of the lubrication layers, excess pressure, and the tank-treading velocity of the membrane. For a multicomponent vesicle passing through a contracting channel, we find that the lipid always phase separates so that the vesicle is stiffer in the front as it passes through the constriction. For both cases of confinement we find that lipid coarsening is arrested under strong confinement, and resumes at a high rate upon relief from extreme confinement. The results may be useful for efficient sorting lipid domains using microfluidic flows by controlled release of vesicles passing through strong confinement.

97 MATHEMATICS AND COMPUTING↗

Simulated performance of biomass gasification based combined power and refrigeration plant for community scale application

Thermal performance analysis and sizing of a biomass gasification based combined power and refrigeration plant (CPR) is reported in this study. The plant is capable of producing 100 kWe of electrical output while simultaneously producing a refrigeration effect, varying from 28-68 ton of refrigeration (TR). The topping gas turbine cycle is an indirectly heated all-air cycle. A combustor heat exchanger duplex (CHX) unit burns producer gas and transfer heat to air. This arrangement avoids complex gas cleaning requirements for the biomass-derived producer gas. The exhaust air of the topping GT is utilized to run a bottoming ammonia absorption refrigeration (AAR) cycle via a heat recovery steam generator (HRSG), steam produced in the HRSG supplying heat to the generator of the refrigeration cycle. Effects of major operating parameters like topping cycle pressure ratio (r{sub p}) and turbine inlet temperature (TIT) on the energetic performance of the plant are studied. Energetic performance of the plant is evaluated via energy efficiency, required biomass consumption and fuel energy savings ratio (FESR). The FESR calculation method is significant for indicating the savings in fuel of a combined power and process heat plant instead of separate plants for power and process heat. The study reveals that, topping cycle attains maximum power efficiency of 30%in pressure ratio range of 8-10. Up to a certain value of pressure ratio the required air flow rate through the GT unit decreases with increase in pressure ratio and then increases with further increase in pressure ratio. The capacity of refrigeration of the AAR unit initially decreases up to a certain value of topping GT cycle pressure ratio and then increases with further increase in pressure ratio. The FESR is found to be maximized at a pressure ratio of 9 (when TIT=1100°C), the maximum value being 53%. The FESR is higher for higher TIT. The heat exchanger sizing is also influenced by the topping cycle pressure ratio and GT-TIT.

09 BIOMASS FUELS↗

Measuring the Aerosol Collection Efficiency and Detector Face Deposition of the Bladewerx KatanaGBM™ (Glove Box Monitor) Continuous Air Monitor

To assist Bladewerx LLC (the Requestor) in testing their new CAM (continuous air monitor) sampler model Bladewerx™ KatanaGBM™ (Glove Box Monitor), the Laboratory (LANL, i.e. Los Alamos National Laboratory) measured the aerosol particle collection efficiency and detector face deposition for several experimental test conditions. Bladewerx LLC provided a prototype KatanaGBM with a set of requested tests. According to these parameters, LANL designed and performed a series of experiments to (A.) Measure the aerosol particle collection efficiency and detector face deposition of the KatanaGBM at three air flow rates of 5, 42, and 70 ALPM (ambient liters per minute), (B.) Measure the collection efficiency and detector face deposition using two sizes of oil droplet particles: 3±1 and 10±1 µm (micron) AED (aerodynamic equivalent diameter), and (C.) Test the KatanaGBM for aerosol collection efficiency and detector face deposition with the wind tunnel’s air flow at three different angles 0°, 45° and 90° (compared to the KatanaGBM’s filter face).

61 RADIATION PROTECTION AND DOSIMETRY↗

Computational Analysis of Hydraulic Efficiency of Michigan DOT Covers J and K

Drainage structures are used in urban street and highway systems to capture stormwater runoff. These structures typically consist of catch basins fitted with grates, inlets, or combination grate/inlet configurations that collect runoff and convey it through buried drainage systems. They are strategically placed within curb-and-gutter systems to enhance public safety by efficiently removing water from roadways and thereby reducing the risk of hydroplaning. The performance of drainage structures is commonly evaluated in terms of hydraulic efficiency, defined as the percentage of flow captured by the basin relative to the total flow reaching the structure. Understanding the hydraulic performance of these structures allows designers to properly space inlets, resulting in cost-effective designs that also help ensure the safety of the traveling public. MDOT uses a variety of drainage structures for runoff capture, as documented in Michigan Department of Transportation (MDOT) Drainage Manual. Many of these structures incorporate sinusoidal-type grates that are not addressed in HEC-22. Because physical modeling of these structures has been limited, further analysis is needed to verify their capture efficiency. Under current MDOT practice, the capture efficiency of these grates is estimated by assuming performance similar to that of a comparably sized reticuline grate described in HEC22. The first phase of this effort, titled Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C, focused on evaluating the hydraulic performance of MDOT’s Cover C grate. Cover C was selected as the initial test candidate because its sinusoidal pattern is representative of other MDOT grates, while it is typically used in high-volume, higher-speed applications. A similar version, Cover CX, is used on interstate highways but does not include transverse bars for bicycle safety. The current second phase of the study expands this work to evaluate MDOT’s Covers J and K. These grates were selected for additional analysis to further assess the hydraulic performance of MDOT drainage structures that are not directly represented by grate configurations in HEC-22. The results of this phase will build on the findings from the Cover C analysis and support improved understanding of the capture efficiency of MDOT’s standard drainage grates. This report is intended to serve as a companion document to the earlier study, Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C [3]. The present work applies the same overall CFD-based evaluation approach to MDOT Covers J and K and compares the resulting performance trends with those previously identified for Cover C. In particular, both studies assess on-grade interception efficiency, sag-location hydraulic capacity, and the effects of partial obstruction relative to HEC-22-based design estimates.

42 ENGINEERING↗

Numerical investigation for the impact of CO2 geologic sequestration on regional groundwater flow

Large-scale storage of carbon dioxide in saline aquifers may cause considerable pressure perturbation and brine migration in deep rock formations, which may have a significant influence on the regional groundwater system. With the help of parallel computing techniques, we conducted a comprehensive, large-scale numerical simulation of CO{sub 2} geologic storage that predicts not only CO{sub 2} migration, but also its impact on regional groundwater flow. As a case study, a hypothetical industrial-scale CO{sub 2} injection in Tokyo Bay, which is surrounded by the most heavily industrialized area in Japan, was considered, and the impact of CO{sub 2} injection on near-surface aquifers was investigated, assuming relatively high seal-layer permeability (higher than 10 microdarcy). A regional hydrogeological model with an area of about 60 km x 70 km around Tokyo Bay was discretized into about 10 million gridblocks. To solve the high-resolution model efficiently, we used a parallelized multiphase flow simulator TOUGH2-MP/ECO2N on a world-class high performance supercomputer in Japan, the Earth Simulator. In this simulation, CO{sub 2} was injected into a storage aquifer at about 1 km depth under Tokyo Bay from 10 wells, at a total rate of 10 million tons/year for 100 years. Through the model, we can examine regional groundwater pressure buildup and groundwater migration to the land surface. The results suggest that even if containment of CO{sub 2} plume is ensured, pressure buildup on the order of a few bars can occur in the shallow confined aquifers over extensive regions, including urban inlands.

54 ENVIRONMENTAL SCIENCES↗

SiC MOSFET Based Single Phase Active Boost Rectifier with Power Factor Correction for Wireless Power Transfer Applications

Wireless Power Transfer (WPT) technology is a novel research area in the charging technology that bridges the utility and the automotive industries. There are various solutions that are currently being evaluated by several research teams to find the most efficient way to manage the power flow from the grid to the vehicle energy storage system. There are different control parameters that can be utilized to compensate for the change in the impedance due to variable parameters such as battery state-of-charge, coupling factor, and coil misalignment. This paper presents the implementation of an active front-end rectifier on the grid side for power factor control and voltage boost capability for load power regulation. The proposed SiC MOSFET based single phase active front end rectifier with PFC resulted in >97% efficiency at 137mm air-gap and >95% efficiency at 160mm air-gap.

active rectifier↗

Continuous caustic aqueous phase electrochemical reforming (CAPER) of ethanol for producing compressed hydrogen

Caustic Aqueous Phase Electrochemical Reforming (CAPER) of ethanol produces pure compressed H 2 at lower voltages, temperatures, and energy requirements than conventional electrolysis, while capturing carbonaceous products. The CAPER flow reactor consists of stainless steel endplates, stainless steel current collectors, and a Teflon flow field. The electrodes are prepared using commercial palladium nanoparticles on carbon support for the anode and platinum nanoparticles on carbon support for the cathode. The catalyst metal loading was 1 mgcm –2 on a 10cm 2 carbon cloth for both electrodes. Our CAPER reactor produces pure H 2 at 80bar and 80°C applying voltages at ≤0.5V. The only gas-phase product detected was H 2 and any carbonaceous products were contained in the liquid phase. The H 2 was produced with 97±4% faradaic efficiency. Further, operating at smaller electrode separation distances (4mm) and 80°C increased the current density. The highest lower heating value efficiency achieved was 28% at a flow rate of 0.05mLmin –1 and an applied voltage of 0.5V. The compressed H 2 was produced at ≤20 kWh kg –1 , which is much lower than electrolysis systems that require upwards of 50 kWh kg –1 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupled numerical approach combining finite volume and lattice Boltzmann methods for multi-scale multi-physicochemical processes

A coupled (hybrid) simulation strategy spatially combining the finite volume method (FVM) and the lattice Boltzmann method (LBM), called CFVLBM, is developed to simulate coupled multi-scale multi-physicochemical processes. In the CFVLBM, computational domain of multi-scale problems is divided into two sub-domains, i.e., an open, free fluid region and a region filled with porous materials. The FVM and LBM are used for these two regions, respectively, with information exchanged at the interface between the two sub-domains. A general reconstruction operator (RO) is proposed to derive the distribution functions in the LBM from the corresponding macro scalar, the governing equation of which obeys the convection–diffusion equation. The CFVLBM and the RO are validated in several typical physicochemical problems and then are applied to simulate complex multi-scale coupled fluid flow, heat transfer, mass transport, and chemical reaction in a wall-coated micro reactor. The maximum ratio of the grid size between the FVM and LBM regions is explored and discussed. -- Highlights: •A coupled simulation strategy for simulating multi-scale phenomena is developed. •Finite volume method and lattice Boltzmann method are coupled. •A reconstruction operator is derived to transfer information at the sub-domains interface. •Coupled multi-scale multiple physicochemical processes in micro reactor are simulated. •Techniques to save computational resources and improve the efficiency are discussed.

97 MATHEMATICS AND COMPUTING↗

Performance evaluation approach for the supercritical helium cold circulators of ITER

The ITER project design foresees Supercritical Helium (SHe) forced flow cooling for the main cryogenic components, namely, the superconducting (SC) magnets and cryopumps (CP). Therefore, cold circulators have been selected to provide the required SHe mass flow rate to cope with specific operating conditions and technical requirements. Considering the availability impacts of such machines, it has been decided to perform evaluation tests of the cold circulators at operating conditions prior to the series production in order to minimize the project technical risks. A proposal has been conceptualized, evaluated and simulated to perform representative tests of the full scale SHe cold circulators. The objectives of the performance tests include the validation of normal operating condition, transient and off-design operating modes as well as the efficiency measurement. A suitable process and instrumentation diagram of the test valve box (TVB) has been developed to implement the tests at the required thermodynamic conditions. The conceptual engineering design of the TVB has been developed along with the required thermal analysis for the normal operating conditions to support the performance evaluation of the SHe cold circulator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

THE OBSERVED M-{sigma} RELATIONS IMPLY THAT SUPER-MASSIVE BLACK HOLES GROW BY COLD CHAOTIC ACCRETION

We argue that current observations of M-{sigma} relations for galaxies can be used to constrain theories of super-massive black holes (SMBHs) feeding. In particular, assuming that SMBH mass is limited only by the feedback on the gas that feeds it, we show that SMBHs fed via a planar galaxy-scale gas flow, such as a disk or a bar, should be much more massive than their counterparts fed by quasi-spherical inflows. This follows from the relative inefficiency of active galactic nucleus feedback on a flattened inflow. We find that even under the most optimistic conditions for SMBH feedback on flattened inflows, the mass at which the SMBH expels the gas disk and terminates its own growth is a factor of several higher than the one established for quasi-spherical inflows. Any beaming of feedback away from the disk and any disk self-shadowing strengthen this result further. Contrary to this theoretical expectation, recent observations have shown that SMBHs in pseudobulge galaxies (which are associated with barred galaxies) are typically under- rather than overmassive when compared with their classical bulge counterparts at a fixed value of {sigma}. We conclude from this that SMBHs are not fed by large (100 pc to many kpc) scale gas disks or bars, most likely because such planar flows are turned into stars too efficiently to allow any SMBH growth. Based on this and other related observational evidence, we argue that most SMBHs grow by chaotic accretion of gas clouds with a small and nearly randomly distributed direction of angular momentum.

79 ASTRONOMY AND ASTROPHYSICS↗

A screening model for predicting injection well pressure buildup and plume extent in CO 2 geologic storage projects

We present a new screening model for predicting injection well pressure buildup and CO 2 plume migration for CO 2 geologic sequestration projects. The model requires only limited information and is quite accurate when compared to detailed simulation results. Such models can assist project developers during the early days of project planning (e.g., for 45Q related projects), and also help regulators perform simple checks against detailed numerical models. The screening model consists of two correlations: one for injectivity index in terms of the slope of the CO 2 fractional flow curve, and the second for total storage efficiency within the footprint of plume as a function of gravity number and slope of the CO 2 fractional flow curve. Using these two correlations, as well as a knowledge of some basic reservoir characteristics and estimates of fluid properties from standard correlations, the injection-well pressure buildup and CO 2 plume extent in the formation can be readily estimated. Finally, the new correlations show a good match with the results of the underlying simulations, and also provide good agreement with independent calculations for two example problems.

42 ENGINEERING↗

Efficiency of clay-TiO2 nanocomposites on the photocatalytic eliminationof a model hydrophobic air pollutant

Clay-supported TiO2 photocatalysts can potentially improve the performance of air treatment technologies via enhanced adsorption and reactivity of target volatile organic compounds (VOCs). In this study, a bench-top photocatalytic flow reactor was used to evaluate the efficiency of hectorite-TiO2 and kaolinite-TiO2, two novel composite materials synthesized in our laboratory. Toluene, a model hydrophobic VOC and a common indoor air pollutant, was introduced in the air stream at realistic concentrations, and reacted under UVA (gamma max = 365 nm) or UVC (gamma max = 254 nm) irradiation. The UVC lamp generated secondary emission at 185 nm, leading to the formation of ozone and other short-lived reactive species. Performance of clay-TiO2 composites was compared with that of pure TiO2 (Degussa P25), and with UV irradiation in the absence of photocatalyst under identical conditions. Films of clay-TiO2 composites and of P25 were prepared by a dip-coating method on the surface of Raschig rings, which were placed inside the flow reactor. An upstream toluene concentration of ~;;170 ppbv was generated by diluting a constant flow of toluene vapor from a diffusion source with dry air, or with humid air at 10, 33 and 66percent relative humidity (RH). Toluene concentrations were determined by collecting Tenax-TA (R) sorbent tubes downstream of the reactor, with subsequent thermal desorption -- GC/MS analysis. The fraction of toluene removed, percentR, and the reaction rate, Tr, were calculated for each experimental condition from the concentration changes measured with and without UV irradiation. Use of UVC light (UV/TiO2/O3) led to overall higher reactivity, which can be partially attributed to the contribution of gas phase reactions by short-lived radical species. When the reaction rate was normalized to the light irradiance, Tr/I gamma, the UV/TiO2 reaction under UVA irradiation was more efficient for samples with a higher content of TiO2 (P25 and Hecto-TiO2), but not for Kao-TiO2. In all cases, reaction rates peaked at 10percent RH, with Tr values between 10 and 50percent higher than those measured under dry air. However, a net inhibition was observed as RH increased to 33percent and 66percent, indicating that water molecules competed effectively with toluene for reactive surface sites and limited the overall photocatalytic conversion. Compared to P25, inhibition by co-adsorbed water was less significant for Kao-TiO2 samples, but was more dramatic for Hecto-TiO2 due to the high water uptake capacity of hectorite.

1?1 and 2?1 phyllosilicates, photocatalysis, indoo↗

Magnetic nozzle and plasma detachment model for a steady-state flow

Plasma propulsion concepts that employ a guiding magnetic field raise the question of how the magnetically controlled plasma can detach from the spacecraft. This paper presents a detachment scenario relevant to high-power thrusters in which the plasma can stretch the magnetic field lines to infinity, similar to the solar wind. In previous work, the corresponding ideal magnetohydrodynamics equations have been solved analytically for a plasma flow in a slowly diverging nozzle. That solution indicates that efficient detachment is feasible if the nozzle is sufficiently long. In order to extend the previous model beyond the idealizations of analytical theory, a Lagrangian code is developed in this work to simulate steady-state kinetic plasma flows and to evaluate nozzle efficiency. The code is benchmarked against the analytical results and then used to examine situations that are not analytically tractable, including plasma behavior in the recent Detachment Demonstration Experiment at the National Aeronautics and Space Administration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle Mass Flow Control for High-Temperature Concentrating Solar Receivers

This report summarizes the results of a two-year project funded by the U.S. Department of Energy's Solar Energy Technologies Office (SuNLaMP 1506) to evaluate the performance of high-temperature (>700 °C) particle receivers for concentrating solar power (see Appendix A for project information). In the first year, novel particle release patterns were designed and tested to increase the effective solar absorptance of the particle curtain. Modeling results showed that increasing the magnitude and frequency of different wave-like patterns increased the effective absorptance and thermal efficiency by several percentage points, depending on the mass flow rate. Tests showed that triangular-wave, square-wave, and parallel-curtain particle release patterns could be implemented and maintained at flow rates of ~10 kg/s/m. The second year of the project focused on the development and testing of particle mass-flow control and measurement methods. An automated slide gate controlled by the outlet temperature of the particles was designed and tested. Testing demonstrated that the resolution accuracy of the slide-gate positioning was less than ~1 mm, and the speed of the slide gate enabled rapid adjustments to accommodate changes in the irradiance to maintain a desired outlet temperature range. Different in-situ particle mass-flow measurement techniques were investigated, and two were tested. The in-situ microwave sensor was found to be unreliable and sensitive to variations in particle flow patterns. However, the in-situ weigh hopper using load cells was found to provide reliable and repeatable measurements of real-time in-situ particle mass flow. On-sun tests were performed to determine the thermal efficiency of the receiver as a function of mass flow rate, particle temperature, and irradiance. Models of the tests were also developed and compared to the tests.

14 SOLAR ENERGY↗