Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fast neutron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Producing Evaluation-quality 239 Pu Average Prompt Fission Neutron Multiplicities using a Correlated Fission Model

An evaluation of the average prompt fission neutron multiplicity, $\bar{ν}_p$, of 239 Pu(n,f) is shown. This evaluation includes (a) the correlated fission model CGMF, and (b) a detailed analysis of past and recently published experimental data. Using CGMF-calculated $\bar{ν}_p$ as prior enables to link, through the use of evaluated model input parameters, $\bar{ν}_p$ to other fission observables such as the prompt fission neutron spectrum (PFNS), preneutron emission fission yields as a function of mass, and the average total kinetic energy of the fragments. These evaluated parameters produce realistic predictions of many fission observables, while the evaluated $\bar{ν}_p$ agrees well (χ 2 ≈ 1) with data. Moreover, with the new evaluated $\bar{ν}_p$, the effective neutron multiplication factor of fast Pu ICSBEP critical assemblies are predicted with a mean bias of 58 pcm compared to 18 pcm with ENDF/B-VIII.0, when paired with a new 239 Pu PFNS and fission cross section. Due to these encouraging validation results, the evaluated $\bar{ν}_p$ is currently part of a release candidate for the 239 Pu ENDF/B-VIII.1 file. Hence, a correlated fission model was used for the first time for evaluating $\bar{ν}_p$ that is of evaluation quality. This is an important step towards consistent evaluations of prompt fission observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proton decay spectroscopy of S 28 and Cl 30

States in 28 S and 30 Cl have been studied using one- and two-proton decay spectroscopy. In the first spectrometer setting, states in 28 S were populated following one-neutron knockout from a fast 29 S beam. Three new states are observed in 28 S from one- and two-proton decay. For the two-proton case the nature of the decay was investigated and found to proceed via sequential two-proton emission. For the second setting, states in 30 Cl were populated via one-proton knockout from a fast 31 Ar beam. The decay energy of the ground and first excited state were measured, with the ground-state decay energy found to be in disagreement with a previous measurement. Here, the spin and parity of these two 30 Cl states were inferred from shell-model calculations.

20 ≤ A ≤ 38↗

Nuclear Data and Cross Section Testing Using ENDF/B-VIII.0

With the release of the Evaluated Nuclear Data File (ENDF)/B-VIII.0 library, nuclear criticality safety practitioners and engineers have access to the latest cross section sets available for their analyses. However, these cross sections must be rigorously tested and validated to ensure that the nuclear data are responsive to the needs of the individuals responsible for developing, implementing, and maintaining computational tools for criticality safety applications. Thus, the ENDF/B-VIII.0 library is tested and validated with a large collection of experiments that were vetted by the International Criticality Safety Benchmark Evaluation Project and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. A selection of benchmark experiments for use within the criticality safety community were prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Nuclear Energy and Fuel Cycle Division at Oak Ridge National Laboratory. The performance of the ENDF/B-VIII.0 library is assessed by using VALID models of benchmark experiments with the beta 12 version of SCALE 6.3 KENO V.a and KENO-VI Monte Carlo codes. The performance is compared with the results obtained from with the ENDF/B-VII.1 library. This report considers multigroup (MG) and continuous energy (CE) formats of the ENDF/B-VIII.0 and -VII.1 libraries. The benchmark experiments within VALID that validate the ENDF/B-VIII.0 library cover 15 broad system categories by using a range of fissile materials, uranium enrichments, plutonium isotopic vectors, and mixed uranium/plutonium systems. These forms are represented as metals, solutions, or various arrays of rods or plates that cover a variety of neutron energy spectra: thermal, fast, mixed, and intermediate. Over 600 cases were considered for use with the KENO V.a and KENO-VI codes with the ENDF/B-VIII.0 library. The results of the Monte Carlo comparison of ENDF/B-VIII.0 to ENDF/B-VII.1 with both KENO V.a and KENO-VI indicate that there is a less than 0.53% Δk difference between the bias of calculated k eff from the expected values. The CE ENDF/B-VIII.0 library results in smaller magnitude biases than the ENDF/B-VII.1 data for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-SOL-THERM, PU-SOL-THERM, and U233-MET-FAST systems, while the MG results yielded smaller magnitude biases for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-COMP-THERM, LEU-SOL THERM, MIX-COMP-FAST, and U233-MET-FAST systems. Most notable are the adjustments to the plutonium and 233 U cross section data, which has resulted in noticeably lower biases in the ENDF/B VIII.0 results for the mixed, plutonium, and 233 U systems. Results of the sensitivity data file comparison generated from TSUNAMI-3D for selected VALID cases for the ENDF/B-VIII.0 library indicate a very high level of agreement with correlation coefficients of the effect of nuclear data uncertainty on k eff (the c k integral parameter) all above 0.99. This indicates that cases with the ENDF/B-VIII.0 library would see very similar responses to any nuclear data errors or change as those with the ENDF/B-VII.1 library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Simulation of the Fast Reactor Fuel Assembly Duct-Bowing Reactivity Effect Using Monte Carlo Neutron Transport and Finite Element Analysis

This paper discusses a new method of simulating the fuel assembly duct-bowing reactivity coefficient for EBR-II run 138B. Quantification of the fuel assembly duct-bowing reactivity effect in liquid metal–cooled fast reactors has been a persistent problem since they were first designed and operated. Simulation of the duct-bowing reactivity effect is difficult because the level of detail required to simulate the effect has exceeded most modeling capabilities. The new method outlined in this paper utilizes the finite element analysis code ANSYS to analyze the thermal and structural components. Here, the displacement of the fuel assembly duct due to thermal expansion and mechanical interaction was calculated by ANSYS using recorded EBR-II run 138B temperature and power boundary value data. The displacement values were incorporated into to a Monte Carlo model of EBR-II run 138B and keff was calculated. Multiple Monte Carlo calculations were performed with duct displacement values corresponding to different reactor temperatures. Using the calculated keff values associated with the different duct displacement results allowed calculation of the duct-bowing reactivity coefficient. The duct-bowing reactivity coefficient was calculated to be –14.5 × 10 –4 $/°C/ ± 4.4%.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

Emulators for Scarce and Noisy Data: Application to Auxiliary-Field Diffusion Monte Carlo for Neutron Matter

Understanding the equation of state (EOS) of pure neutron matter is necessary for interpreting multimessenger observations of neutron stars. Reliable data analyses of these observations require well-quantified uncertainties for the EOS input, ideally propagating uncertainties from nuclear interactions directly to the EOS. This, however, requires calculations of the EOS for a prohibitively larger number of nuclear Hamiltonians, solving the nuclear many-body problem for each one. Quantum Monte Carlo methods, such as auxiliary-field diffusion Monte Carlo (AFDMC), provide precise and accurate results for the neutron matter EOS, but they are very computationally expensive, making them unsuitable for the fast evaluations necessary for uncertainty propagation. Here, we employ parametric matrix models to develop fast emulators for AFDMC calculations of neutron matter and use them to directly propagate uncertainties of coupling constants in the Hamiltonian to the EOS. As these uncertainties include estimates of the effective field theory truncation uncertainty, this approach provides robust uncertainty estimates for use in astrophysical data analyses. In conclusion, this Letter will enable novel applications such as using astrophysical observations to put constraints on coupling constants for nuclear interactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design Optimization of a Criticality Experiment for the Molten Chloride Reactor Experiment Facility

Neutronics simulations of Molten Chloride Fast Reactors have quantifiable biases that arise from nuclear data, modeling choices, or numerical methods. The multiphysics nature of molten salt reactors makes it challenging to disentangle neutronics modeling biases from biases originating from other physical phenomena. In comparison to a mock-up reactor, criticality experiments can specifically assess the neutronics modeling bias while limiting multiphysics effects. The criticality experiment must be neutronically representative of the full-scale reactor to be valuable. Here, in this paper, we describe the design of a criticality experiment to validate only the neutronics of TerraPower’s Molten Chloride Reactor Experiment (MCRE) and its criticality safety upset scenarios. The proposed experiment uses different chlorine-containing materials to maximize its similarity to the MCRE. The design process uses a constrained Bayesian optimization algorithm to investigate different objective functions that use covariance information for 35 Cl nuclear data. The experiments could reduce the nuclear data–induced uncertainty in k eff of the MCRE from 2161 to 886 pcm. They would also increase the upper subcritical limit of the MCRE criticality safety upset scenario from 0.94101 to 0.94476 when using the WHISPER analysis framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast rotation of nuclei with extreme isospin in the vicinity of neutron and proton drip lines

Abstract The analysis of the present understanding of collective rotation in very neutron-rich nuclei is presented. It is shown that collective rotation can lead to the increase of stability of rotational states with increasing spin. The detailed investigation of rotational excitations in very proton-rich nuclei confirms this conclusion and indicates that experimental studies of such features are more feasible in the nuclei near proton drip line. They also show that rotational bands which are proton quasi-bound at zero or low spins can be transformed into proton bound ones at high spin by collective rotation of nuclear systems. This is due to strong Coriolis interaction which acts on high-jor strongly mixed M orbitals and drives the highest in energy occupied single-particle states into negative energy domain. These physical mechanisms lead to a substantial extension of the nuclear landscape beyond the spin zero proton drip line. In addition, a new phenomenon of the formation of giant proton halos in rotating nuclei emerges: it is triggered by the occupation of strongly mixed M intruder orbitals.

Physics↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband X-ray burst spectroscopy of the fast-radio-burst-emitting Galactic magnetar

Magnetars are young, magnetically powered neutron stars that possess the strongest magnetic fields in the Universe. Fast radio bursts (FRBs) are extremely intense millisecond-long radio pulses of primarily extragalactic origin, and a leading attribution for their genesis focuses on magnetars. A hallmark signature of magnetars is their emission of bright, hard X-ray bursts of sub-second duration. On 27 April 2020, the Galactic magnetar SGR J1935+2154 emitted hundreds of X-ray bursts within a few hours. One of these temporally coincided with an FRB, the first known detection of an FRB from the Milky Way. Here, we present spectral and temporal analyses of 24 X-ray bursts emitted 13 hours prior to the FRB and seen simultaneously with the Neutron Star Interior Composition Explorer (NICER) mission of the National Aeronautics and Space Administration and with the Fermi Gamma-ray Burst Monitor (GBM) mission in their combined energy range of 0.2 keV to 30 MeV. These broadband spectra permit direct comparison with the spectrum of the FRB-associated X-ray burst (FRB-X). We demonstrate that all 24 NICER and GBM bursts are very similar temporally to the FRB-X, but strikingly different spectrally. The singularity of the FRB-X burst is perhaps indicative of an uncommon locale for its origin. We suggest that this event originated in quasi-polar open or closed magnetic field lines that extend to high altitudes.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband X-ray burst spectroscopy of the fast-radio-burst-emitting Galactic magnetar

Magnetars are young, magnetically powered neutron stars that possess the strongest magnetic fields in the Universe. Fast radio bursts (FRBs) are extremely intense millisecond-long radio pulses of primarily extragalactic origin, and a leading attribution for their genesis focuses on magnetars. A hallmark signature of magnetars is their emission of bright, hard X-ray bursts of sub-second duration. On 27 April 2020, the Galactic magnetar SGR J1935+2154 emitted hundreds of X-ray bursts within a few hours. One of these temporally coincided with an FRB, the first known detection of an FRB from the Milky Way. Here, we present spectral and temporal analyses of 24 X-ray bursts emitted 13 hours prior to the FRB and seen simultaneously with the Neutron Star Interior Composition Explorer (NICER) mission of the National Aeronautics and Space Administration and with the Fermi Gamma-ray Burst Monitor (GBM) mission in their combined energy range of 0.2 keV to 30 MeV. These broadband spectra permit direct comparison with the spectrum of the FRB-associated X-ray burst (FRB-X). We demonstrate that all 24 NICER and GBM bursts are very similar temporally to the FRB-X, but strikingly different spectrally. The singularity of the FRB-X burst is perhaps indicative of an uncommon locale for its origin. We suggest that this event originated in quasi-polar open or closed magnetic field lines that extend to high altitudes.

G. Younes↗

Numerical assessment of the impact of the guiding-centre approximation on fast ion simulations in NSTX

Guiding-centre (GC) and full-orbit (FO) simulations of the beam-injected fast ion distribution and the corresponding neutron emissivity have been carried out for magnetohydrodynamics-quiescent National Spherical Torus eXperiment (NSTX) plasmas, using a combination of ASCOT5 and DRESS, to assess the suitability of the GC approximation for fast ions in NSTX. It was found that GC and FO simulations predicted substantially different steady-state distributions in both position and velocity space and different neutron emissivity profiles, leading to a 15% reduction in the predicted global neutron rate for FO relative to GC. These changes accompany a higher magnetic moment in FO, and correspond to a change in particle orbits from co-passing to trapped and stagnation orbits. ASCOT5 was also benchmarked against TRANSP/NUBEAM with input loaded entirely from TRANSP/NUBEAM output files, with agreement found between the GC simulations when finite Larmor radius (FLR) corrections were omitted. ASCOT5 FO and TRANSP/NUBEAM with FLR produced fast ion distributions which differed in localised regions, but predicted global neutron rates which agree within 3%.

ASCOT↗

Identifying Neutron Irradiation in Space to Mitigate Bio-Medical Effects

Ubiquitous GCR high energy particles >1 GeV is primary concern • Medical effects compounded by ionizing dose of radiation from energetic particles- cancer, mutations, microbiome changes • Cancer induction and effects are irreversible after initiation • Long term space radiation exposure is cancer promoting but reversible Secondary GCR and Solar induced neutron spallation is a concern • Produced by interactions with space craft materials, EVA and planetary surfaces • Neutron Quality Factor is 10x that of beta, x-ray or gamma rays Space isn’t friendly to life or electronics! Real-time charged particle and EARLY neutron detection are required. Traveling fast or digging deep are the best protection. Nuclear space propulsion through LENR/LCF/Solid-State Fusion is a good bet!

space medicine↗

Godiva IV Central Cavity Neutron Environment Characterization with Threshold Neutron Detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235 U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lattice Confinement Fusion & Fast Fission for Space

Lattice Confinement Fusion (LCF) 1 • Fusion of hydrogen isotopes into helium isotopes • No tokamak magnets or laser power supplies • Nuclear fuel is confined and triggered within lattice • Nuclear reactions enhanced by electron screening • Extended Electrodynamics (EED) role • NASA published results in Physical Review C 2,3 • Locally hot but globally cold • Commercialized in 2025 to produce medical radioisotopes 4 Lattice Confinement Fusion Fast-Fission Hybrid Reactor • Fusion neutrons fission uranium, spent fuel rods or thorium • No enriched uranium, cleaner fission! • Demonstrated with US Navy and GEC • Supported by NASA STMD (NIAC) and NSF Application • LEO, Deep Space Power and High I sp Propulsion • (Terrestrial)

lattice confinement fusion↗

Analyzing the thermionic reactor critical experiments

The Thermionic Reactor Critical Experiments (TRCE) consisted of fast spectrum highly enriched U-235 cores reflected by different thicknesses of beryllium or beryllium oxide with a transition zone of stainless steel between the core and reflector. The mixed fast-thermal spectrum at the core reflector interface region poses a difficult neutron transport calculation. Calculations of TRCE using ENDF/B fast spectrum data and GATHER library thermal spectrum data agreed within about 1 percent for the multiplication factor and within 6 to 8 percent for the power peaks. Use of GAM library fast spectrum data yielded larger deviations. The results were obtained from DOT R Theta calculations with leakage cross sections, by region and by group, extracted from DOT RZ calculations. Delineation of the power peaks required extraordinarily fine mesh size at the core reflector interface.

Niederauer, G. F.↗