Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

The potential for high performance HgCdTe arrays at 4 microns

The potential of existing technology at Rockwell International in terms of the goals for astronomical detector arrays in the 3 to 5 micron interval is evaluated. Measurements have been obtained for a number of samples of HgCdTe diodes manufactured by Rockwell International. All the diodes reported on here had cutoff wavelengths at high temperatures of 4.6 to 4.7 microns. Although no confirming measurements were made, the cutoff wavelength is expected to move to 5 microns or beyond at the low temperatures of our tests. Diode sizes ranged from 20 to 150 microns. The test program yielded full diode curves and relative response at 3.4 microns for the sample diodes as a function of temperature. Dark currents are quoted below as the current passing through the diode with a back bias of 50 mV. The various diode types showed a wide range of behavior, both with regard to dark current and responsibility. The test results for one of the best diode types are illustrated. This detector has a size of 148 microns and a cutoff wavelength of 4.61 microns.

Rieke, G. H.↗

A microwave-biased millimeter- and submillimeter-wave detector using InSb.

Description of a high-purity n-type indium antimonide sample mounted in a reentrant cavity, cooled to 4.2 K, and operated as a millimeter-wave detector. The scheme utilizes a down-conversion process, and free-carrier absorption is the mechanism responsible for the detection process. Power applied at the millimeter-wave frequency causes a change in the material conductivity, which in turn causes a change in the X-band power absorption. Cavity perturbation techniques are used to analyze the scheme. The detector was operated successfully at frequencies between 35 and 150 GHz with no long-wavelength or short-wavelength cutoff observed. The scheme offers a fast, highly sensitive, and rugged detector with low conversion loss.

Eldumiati, I. I.↗

Angular response calibration of the burst and transient source experiment

The Gamma Ray Observatory includes four experiments designed to observe the gamma-ray universe. Laboratory measurements to test the response the Burst and Transient Source Experiment (BATSE) modules to gamma-ray sources that are non-axial were recently completed. The results of these observations are necessary for the correct interpretation of BATSE data obtained after it is put in Earth orbit. The launch is planned for March, 1900. Preliminary analyses of these test data show the presence of a radial dependence to the detector's light collection efficiency. It is proposed to evaluate the importance of this radial response, analyze future experimental data to derive the actual functional dependence on radius, and calculate the net effect on the output spectrum as a function of the angle of incidence.

Lestrade, John Patrick↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

A thick Anger camera for gamma-ray astronomy

The NaI(Tl) Anger camera is a natural candidate for a position sensitive detector in imaging of astrophysical gamma-ray sources. Here laboratory measurements are presented of the response of a relatively thick (5.1 cm) NaI(Tl) Anger camera designed for coded aperture imaging in the 50 keV to 2 MeV energy range. A position resolution of 10.5 mm FWHM at 122 keV and 6.3 mm FWHM at 662 keV. The energy resolution was 7 percent FWHM at 662 keV. The ability of the detector to resolve the depth of the gamma-ray interaction and the use of this depth resolution to reduce back-incident and internal background is discussed.

Cook, W. R.↗

Displacement response, detection limit, and dynamic range of fiber-optic lever sensors

The authors present the evaluation of the displacement response, detection limit, and dynamic range of fiber-optic lever sensors in a general format to establish their dependence on fiber sizes, optoelectronic detector specifications, input power, and other relevant parameters. The formations for the normalized reflected optical power change are derived for the evaluation of the optimal sensor response, the linearity range, and the minimum detectable displacement. The theoretical models are verified by an experiment which determines sensor response, modulation index, reflected optical power change, and linear response range through dynamic measurement. The application of this theoretical model to the study of a fiber-optic microphone for acoustic pressure detection is considered.

He, Gang↗

On-board radiometric preprocessing for multispectral linear arrays /MLA/

A program that was undertaken to design, fabricate, and test a real-time hardwired data preprocessor is described, which applies a calibration normalization to each detector in a 576-element linear photodiode array. Various calibration problems were uncovered, such as those (1) due to system noise in recording the calibration tables, or (2) due to thermal drift and (3) due to the original quantization process. It was determined that in this experiment, noise and thermal drift led to fixed errors in the normalization of responses on the order of + or - 10 counts, out of 255 counts for many of the detectors.

Thompson, L. L.↗

The Average Quality Factors by TEPC for Charged Particles

The quality factor used in radiation protection is defined as a function of LET, Q(sub ave)(LET). However, tissue equivalent proportional counters (TEPC) measure the average quality factors as a function of lineal energy (y), Q(sub ave)(Y). A model of the TEPC response for charged particles considers energy deposition as a function of impact parameter from the ion s path to the volume, and describes the escape of energy out of sensitive volume by delta-rays and the entry of delta rays from the high-density wall into the low-density gas-volume. A common goal for operational detectors is to measure the average radiation quality to within accuracy of 25%. Using our TEPC response model and the NASA space radiation transport model we show that this accuracy is obtained by a properly calibrated TEPC. However, when the individual contributions from trapped protons and galactic cosmic rays (GCR) are considered; the average quality factor obtained by TEPC is overestimated for trapped protons and underestimated for GCR by about 30%, i.e., a compensating error. Using TEPC's values for trapped protons for Q(sub ave)(y), we obtained average quality factors in the 2.07-2.32 range. However, Q(sub ave)(LET) ranges from 1.5-1.65 as spacecraft shielding depth increases. The average quality factors for trapped protons on STS-89 demonstrate that the model of the TEPC response is in good agreement with flight TEPC data for Q(sub ave)(y), and thus Q(sub ave)(LET) for trapped protons is overestimated by TEPC. Preliminary comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.2-4.1, while TEPC measures 2.9-3.4 for QQ(sub ave)(y), indicating that QQ(sub ave)(LET) for GCR is underestimated by TEPC.

Kim, Myung-Hee Y.↗

Infrared detector performance in the Shuttle Infrared Telescope Facility /SIRTF/

The limitations imposed on infrared detectors for SIRTF are quite different from those imposed on ground-based, balloon-borne, or aircraft-borne systems. The paper examines the limitations and provides performance predictions corresponding to SIRTF conditions. Detector parameters typical of an infrared camera are used. The detector size is taken to be of the order of the diffraction-limited spot, frequency response is taken to correspond to a fraction of a second or less time constant, and spectral definition is provided by multilayer dielectric filters, inductive or capacitive grids, intrinsic absorption, or a combination of these. A nominal 10-micron bandwidth is assumed. The discussion covers atmospheric absorption and emission, zodiacal dust radiance, Shuttle contaminants, telescope self-emission, charged particle radiation, clear environment detector performance, and trapped radiation effects. It is concluded that the SIRTF design and operating conditions will allow current and near-term state-of-the-art detectors to reach their performance limits with SIRTF at a temperature of 10-12 K.

Mccarthy, S. G.↗

OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. A preliminary estimate of the decay timescale for one detector is that a drop of 0.1-0.2% occurs over a ten day period, indicating that relatively infrequent cal lamp exposures can mitigate the behavior to extremely low levels.

Collins, Nick↗

Hybrid gas scintillation proportional counter/phoswich detector for hard X-ray astronomy

A concept is presented for a balloon-borne imaging hybrid proportional counter/phoswich detector of medium to hard X-rays. The phoswich would be optically coupled to the exit window of the proportional counter, and both detectors would use a common position-sensitive readout. It is anticipated that such a detector could combine the good energy and position resolution and excellent background rejection ability of the proportional counter for incident photon energies less than 100 keV with the extended response of the phoswich for higher energies. The phoswich could also be used to reject Compton scattering events in the proportional counter. This detector concept is studied using numerical simulations of a 400 sq cm square prototype detector. Results from this simulation indicate that current levels of proportional counter and phoswich performance are attainable at small cost in quantum efficiency, compared to a bare phoswich detector.

Grindlay, Jonathan E.↗

Chandra ACIS Observations of Jovian X-Ray Emission

On November 25 and 26, 1999, the Chandra X-ray spacecraft conducted a set of four 19,000 sec observations of Jupiter. The ACIS-S instrument configuration was used for its good low energy efficiency and spatial resolution. An anomalous response was obtained which was subsequently attributed to strong jovian infrared radiation penetrating the detector and piling up spurious events across the entire X-ray range. However, the pre-observation establishment of an offsetting bias field has allowed the recovery of data from that portion of Jupiter's disc which remained within the elevated portion of the bias field during the observation. This ranges from fewer than 3000 sec to the entire observing time for about 10% of the planet. Auroral emission is seen near both poles in each observation. The northern aurora ia overall more intense than the southern, consistent with prior Einstein and ROSAT Observatory results. The southern aurora shows more modulation with Jupiter's rotation than the northern. Spatial resolution has been improved by at least a factor of two over prior measurements but convincing evidence of structure has not been seen. Lower latitude emission, first observed by ROSAT, is confirmed with flux levels averaging more than a factor of five below peak auroral values. Pronounced variation in the observed emission has occurred over the observing period. The spectral response extends from 0.24 keV, below which noise dominates, to about 1.2 keV. For all four observations the spectrum is clearly enhanced between 0.45 and 0.85 keV. This is apparently unequivocal evidence that Jupiter's X-ray emission is the result of oxygen and perhaps sulfur ions precipitating into the planet's atmosphere, where they undergo charge exchange interactions. The identification of specific transitions lines in the spectrum is among the ongoing efforts. A bremsstrahlung component has not yet been identified.

Garmire, Gordon↗

Methods of measurement for semiconductor materials, process control, and devices

Activities directed toward the development of methods of measurement for semiconductor materials, process control, and devices are described. Topics investigated include: measurements of transistor delay time; application of the infrared response technique to the study of radiation-damaged, lithium-drifted silicon detectors; and identification of a condition that minimizes wire flexure and reduces the failure rate of wire bonds in transistors and integrated circuits under slow thermal cycling conditions. Supplementary data concerning staff, standards committee activities, technical services, and publications are included as appendixes.

Bullis, W. M.↗

Gamma Ray Astronomy

The project has progressed successfully during this period of performance. The highlights of the Gamma Ray Astronomy teams efforts are: (1) Support daily BATSE data operations, including receipt, archival and dissemination of data, quick-look science analysis, rapid gamma-ray burst and transient monitoring and response efforts, instrument state-of-health monitoring, and instrument commanding and configuration; (2) On-going scientific analysis, including production and maintenance of gamma-ray burst, pulsed source and occultation source catalogs, gamma-ray burst spectroscopy, studies of the properties of pulsars and black holes, and long-term monitoring of hard x-ray sources; (3) Maintenance and continuous improvement of BATSE instrument response and calibration data bases; (4) Investigation of the use of solid state detectors for eventual application and instrument to perform all sky monitoring of X-Ray and Gamma sources with high sensitivity; and (5) Support of BATSE outreach activities, including seminars, colloquia and World Wide Web pages. The highlights of this efforts can be summarized in the publications and presentation list.

Wu, S. T.↗

An Overview of MODIS Calibration and Characterization

The MODerate Resolution Imaging Spectroradiometer (MODIS) is one of the key instruments for the NASA s Earth Observing System (EOS). It is currently operating on both EOS Terra and Aqua satellites. The MODIS is a major advance over its heritage sensors in terms of its spectral, spatial, and temporal resolutions with frequent global observations and a broad range of science applications. There are 20 reflective solar bands (RSB) with center wavelengths ranging from 0.41 to 2.l microns and 16 thermal emissive bands (TEB) from 3.7 to 14.4 microns. The absolute radiometric accuracy requirements (lsigma) at the typical spectral radiance levels are plus or minus 2% for the RSB reflectance factors and plus or minus 5% for the RSB radiance products. With few exceptions, the TEB requirements are plus or minus 1%. To verify that the instruments met their specified design requirements both Terra and Aqua MODIS underwent extensive pre-launch calibration and characterization at various levels, including system-level thermal vacuum testing. On-orbit calibration and characterization are performed by the on-board calibrators: a solar diffuser (SD) and a solar diffuser stability monitor (SDSM), a V-groove flat panel blackbody (BB), and a spectro-radiometric calibration assembly (SRCA). In this paper, we present an overview of MODIS calibration and characterization activities, methodologies, and lessons learned from pre-launch testing and on-orbit operations. Key issues to be discussed include our on-orbit efforts of monitoring detectors noise characterization, tracking solar diffuser and optics degradation, and updating sensor s response versus scan-angle. The MODIS experience has provided invaluable lessons that are being used in designing and testing the Visible Infrared Imaging Radiometer Suite (VIIRS), a direct follow-on to the MODIS that will be flown on the National Polar-Orbit Operational Environmental Satellite System (NPOESS) missions.

Xiong, X.↗

Development of a Transition-Edge Sensor Anti-Coincidence Detector for a Probe Class Mission

The Light Element Mapper (LEM), a probe class mission proposal slated for submission in 2023, combines a large X-ray optic with an extremely large format microcalorimeter array to probe the physics of galaxy formation with a grasp 22x greater than ATHENA and 7x greater than Lynx. The focal plane for LEM requires a larger anti-coincidence detector than the other missions while maintaining or exceeding their high-speed response, presenting a challenge for claiming technical readiness at the time of the announcement of opportunity (AO). We will perform a rapid demonstration in the next year including design, fabrication and integration and test of a high-fidelity transition-edge sensor (TES) based device at a scale suitable for LEM.

James Chervenak↗

Low-cost 20-22 GHz MIC active receiver/radiometer

A microwave integrated circuit active receiver is built and tested at 19-25 GHz. The receiver consists of a planar CPW-fed double folded-slot antenna coupled to a six-stage MESFET (metal semiconductor field effect transistors) amplifier and followed by a planar Schottky-diode detector. The folded-slot antenna on a GaAs half-space results in a wide frequency bandwidth suitable for MMIC amplifiers. The measured system performance show a video responsivity close to 1 GV/W at 20 GHz with a 3-dB bandwidth of 1500 MHz. A novel method which uses the planar video detector after the amplifier stages as an RF (radio frequency) mixer is used to measure the noise-figure of the direct detection radiometer. The system noise figure is 4.8 dB at 22 GHz. The radiometer sensitivity to a hot/cold load is 3.8 mu V/K. The measured antenna patterns show a 90% Gaussicity at 20-22 GHz. The active MIC receiver can be integrated monolithically for low-cost applications and is well suited for millimeter-wave linear imaging arrays.

PLANAR SCHOTTKY DIODE DETECTOR↗