Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Progress in the development of integrating JFET amplifiers

A new approach to infrared detector readout has appeared with the development of integrating JFET amplifiers. This brief progress report includes results on the operation of commercially available devices at a temperature of 40 K, on their sensitivity and on an effort to develop a new JFET with properties optimized for cryogenic applications. Even with presently available devices it will be shown that for applications such as the Space Infrared Telescope Facility (SIRTF), the most strigent sensitivity requirements of noise currents as low as 1 electron/sec in less than 100 seconds of integration can be met.

Low, F. J.↗

Multi-Band and Broad-Band Infrared Detectors Based on III-V Materials for Spectral Imaging Instruments

Quantum well infrared photodetector technology has shown remarkable success by realizing large-format focal plane arrays in both broad-bands and in multi-bands. The spectral response of these detectors based on the III-V material system are tailorable within the mid and long wavelength IR bands (similar to 3-25 mu m) and possibly beyond. Multi-band and broad-band detector arrays have been developed by vertically integrating stacks of multi quantum wells tailored for response in different wavelengths bands. Each detector stack absorbs photons within the specified wavelength band while allowing the transmission other photons, thus efficiently permitting multiband detection. Flexibility in many design parameters of these detectors allows for tuning and tailoring the spectral shape according to application requirements, specifically for spectral imaging instruments.

quantum well devices↗

Thermal detectors for X-ray astronomy

The characteristics of an 'ideal' spectrometer for X-ray astronomy are discussed. Special attention is given to the development of new thermal detectors (calorimeters) for the AXAF, which are based on the conversion of the energy of a single X-ray photon entirely into heat. The results obtained so far yielded the FWHM value of 17 eV at 100 mK, but the values for each of the contributing noise components measured separately were less than 10 eV, suggesting that the limiting value for AXAF will be better than 10 eV. A summary of the expected parameters for an AXAF calorimeter is presented.

Holt, Stephen S.↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a low-pressure Multi-Mesh THGEM detector for fission experiments at FRIB

Abstract A small-area imaging detector prototype for position measurement of fission fragments produced in low energy heavy-ion reactions is presented in this study. The detector readout is equipped with a 2-dimensional, position-sensitive gaseous avalanche readout based on the novel Multi-Mesh Thick-GEM (MM-THGEM), and is coupled to a delay-line board for particle localization. The prototype has an effective area of 10 × 10 cm 2 and is operated in isobutane at low pressure (7–10 Torr). We present and discuss a series of systematic evaluation tests performed by irradiating the detector with α-particles and fission fragments emitted by small-rate sources ( 241 Am, 249 Cf and 252 Cf). Position and time resolutions of about 0.42 mm and 1 ns were achieved, respectively. This work serves as a benchmark for the development of a large-scale array of detectors for experiments with fission and fission-like reaction products at the Facility for Rare Isotope Beams (FRIB).

Instruments & Instrumentation↗

The CMS Magnetic Field Measuring and Monitoring Systems

This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured and is currently monitored by four nuclear magnetic resonance (NMR) probes installed using special tubes outside the barrel hadron calorimeter. Two more NRM probes were installed at the faces of the tracking system. The field inside the superconducting solenoid was precisely measured in 2006 in a cylindrical volume of 3.448 m in diameter and 7 m in length using 10 three-dimensional (3D) B-sensors based on the Hall effect. These B-sensors were installed on each of the two propeller arms of an automated field-mapping machine. In addition to these measurement systems, a system for monitoring the magnetic field during the CMS detector operation has been developed. Inside the solenoid in the horizontal plane, 4 3D B-sensors were installed at the faces of the tracking detector. Twelve 3D B-sensors were installed on the surfaces of the flux-return yoke nose disks. Seventy 3D B-sensors were installed in the air gaps of the CMS magnet yoke. A specially developed flux loop technique was used for the most complex measurements of the magnetic flux density inside the steel blocks of the CMS magnet yoke. The flux loops are installed in 22 sections of the flux-return yoke blocks. The areas enclosed by these coils varied from 0.3 to 1.59 m$^{2}$ in the blocks of the barrel wheels and from 0.5 to 1.12 m$^{2}$ in the blocks of the yoke endcap disks. The development of these systems and the results of the magnetic flux density measurements across the CMS magnet are presented and discussed in this review article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical flameout detector

A device has been developed which monitors the presence of a flame within a combustion chamber. The optical flameout detection system responds to gross changes in combustor light intensity, which is monitored in two spectral bands. A photomultiplier tube makes optical measurements in the ultraviolet portion of the spectrum, and a silicon photodiode covers the visible region. The detectors, located outside the combustion chamber, receive the light energy radiated from the combustion process through fiber optic probes designed to operate in a high pressure environment. The optical fibers are aimed diagonally through the center of the injector at the combustion chamber wall downstream of the injector. The probes observe events occurring within a narrow conical-shaped field of view so that the system can quickly detect longitudinal movement of the flame front away from the injector. If a change in intensity of the flame is detected, the fuel supply to the combustion chamber is shut off, limiting the amount of unburned fuel in the combustion chamber which could reignite.

Borg, Stephen E.↗

Optical Flameout Detector

A device has been developed which monitors the presence of a flame within a combustion chamber. The optical flameout detection system responds to gross changes in combustor light intensity which is monitored in two spectral bands. A photomultiplier tube makes optical measurements in the ultraviolet portion of the spectrum and a silicon photodiode covers the visible region. The detectors, located outside the combustion chamber, receive the light energy radiated from the combustion process through fiber optic probes designed to operate in a high pressure environment. The optical fibers are aimed diagonally through the center of the injector at the combustion chamber wall downstream of the injector. The probe observes events occurring within a narrow conical-shaped field of view so that the system can quickly detect longitudinal movement of the flame front away from the injector. If a change in intensity of the flame is detected, the fuel supply to the combustion chamber is shut off limiting the amount of unburned fuel in the combustion chamber which could reignite.

Borg, Stephen E.↗

Scalable DAQ system operating the CHIPS-5 neutrino detector

The CHIPS R&D project focuses on development of low-cost water Cherenkov neutrino detectors through novel design strategies and resourceful engineering. This work presents an end-to-end DAQ solution intended for a recent 5 kt CHIPS prototype, which is largely based on affordable mass-produced components. Much like the detector itself, the presented instrumentation is composed of modular arrays that can be scaled up and easily serviced. A single such array can carry up to 30 photomultiplier tubes (PMTs) accompanied by electronics that generate high voltage in-situ and deliver time resolution of up to 0.69 ns. In addition, the technology is compatible with the White Rabbit timing system, which can synchronize its elements to within 100 ps. While deployment issues did not permit the presented DAQ system to operate beyond initial evaluation, the presented hardware and software successfully passed numerous commissioning tests that demonstrated their viability for use in a large-scale neutrino detector, instrumented with thousands of PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LWIR detector requirements for low-background space applications

Detection of cold bodies (200 to 300 K) against space backgrounds has many important applications, both military and non-military. The detector performance and design characteristics required to support low-background applications are discussed, with particular emphasis on those characteristics required for space surveillance. The status of existing detector technologies under active development for these applications is also discussed. In order to play a role in future systems, new, potentially competing detector technologies such as multiple quantum well detectors must not only meet system-derived requirements, but also offer distinct performance or other advantages over these incumbent technologies.

Deluccia, Frank J.↗

Large Format Arrays for Far Infrared and Millimeter Astronomy

Some of the most compelling questions in modem astronomy are best addressed with submillimeter and millimeter observations. The question of the role of inflation in the early evolution of the universe is best addressed with large sensitive arrays of millimeter polarimeters. The study of the first generations of galaxies requires sensitive submillimeter imaging, which can help us to understand the history of energy release and nucleosynthesis in the universe. Our ability to address these questions is dramatically increasing, driven by dramatic steps in the sensitivity and size of available detector arrays. While the MIPS instrument on the SIRTF mission will revolutionize far infrared astronomy with its 1024 element array of photoconductors, thermal detectors remain the dominant technology for submillimeter and millimeter imaging and polarimetry. The last decade has seen the deployment of increasingly large arrays of bolometers, ranging from the 48 element arrays deployed on the KAO in the late 198Os, to the SHARC and SCUBA arrays in the 1990s. The past years have seen the deployment of a new generation of larger detector arrays in SHARC II (384 channels) and Bolocam (144 channels). These detectors are in operation and are beginning to make significant impacts on the field. Arrays of sensitive submillimeter bolometers on the SPIRE instrument on Herschel will allow the first large areas surveys of the sky, providing important insight into the evolution of galaxies. The next generation of detectors, led by SCUBA II, will increase the focal scale of these instruments by an order of magnitude. Two major missions are being planned by NASA for which further development of long wavelength detectors is essential, The SAFlR mission, a 10-m class telescope with large arrays of background limited detectors, will extend our reach into the epoch of initial galaxy formation. A major goal of modem cosmology is to test the inflationary paradigm in the early evolution of the universe. To this end, a mission is planned to detect the imprint of inflation on the CMB by precision measurement of its polarization. This work requires very large arrays of sensitive detectors which can provide unprecedented control of a wide range of systematic errors, given the small amplitude of the signal of interest. We will describe the current state of large format detector arrays, the performance requirements set by the new missions, and the different approaches being developed in the community to meet these requirements. We are confident that within a decade, these developments will lead to dramatic advances in our understanding of the evolution of the universe.

Moseley, Harvey↗

Analysis with the ORIGEN Module of PNAR Spent Fuel Measurements for Nuclear Safeguards Applications

This report documents the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements for 23 boiling water reactor spent fuel assemblies that were performed in Finland under Action Sheet 65, which is an international collaboration on spent fuel safeguards verification methods in the context of the Finnish spent fuel encapsulation/repository system. PNAR measures the passive neutron and gamma emission rates from each of the spent fuel assemblies like a Fork detector, and it also measures the PNAR ratio, which is expected to correlate with the net neutron multiplication of the measured fuel assembly. The analysis was performed with the Oak Ridge Isotope Generation and Depletion (ORIGEN) Data Analysis Module, which was originally developed for predicting Fork detector spent fuel measurement signals in real time and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the International Atomic Energy Agency. The module includes the ORIGEN burnup analysis code and integrates detector response functions pregenerated using the MCNP Monte Carlo transport code to predict the detector signals in several seconds per assembly. In this study, new response functions specific to the analyzed PNAR measurements were generated for the ORIGEN Module. The study also analyzes the impact of using detailed fuel design and operation information vs. standard safeguards information on the results calculated with the ORIGEN Module. Using detailed information reduced the standard deviation of the relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. An uncertainty assessment of the calculations was also performed to estimate the potential impact of the accuracy and the completeness of declaration information on the calculated results for the count rates and net neutron multiplications. The ORIGEN Module predictions for PNAR signals and net neutron multiplication are expected to directly support the safeguards inspectors’ efforts to verify operator declarations of a spent fuel assembly in real time in safeguards practices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RD53 pixel readout integrated circuits for ATLAS and CMS HL-LHC upgrades

The RD53 collaboration has since 2013 developed new hybrid pixel detector chips with 50 × 50 μm2 pixels for the HL-LHC upgrades of the ATLAS and CMS experiments at CERN. A common architecture, design and verification framework has been developed to enable final pixel chips of different sizes to be designed, verified and tested to handle extreme hit rates of 3 GHz/cm2 (up to 12 GHz per chip) together with an increased trigger rate of 1 MHz and efficient readout of up to 5.12 Gbits/s per pixel chip. Tolerance to an extremely hostile radiation environment with 1 Grad over 10 years and induced SEU (Single Event Upset) rates of up to 100 upsets per second per chip have been major challenges to make reliable pixel chips. Three generations of pixel chips, and many specific mixed signal building blocks and radiation test chips, have been submitted and extensively tested to get to final production chips. The large, complex and high rate pixel chips have been developed with a strong emphasis on low power consumption together with a concurrent development and qualification of novel serial powering at chip, module and system level, to minimize detector material budget.

Alimonti, G↗

LST and supporting technology

In order to realize the LST objectives of high angular resolution, extended wavelength coverage and faint object detection, the performance of the instruments must be matched to that of the telescope. To insure that adequate technology is available by 1976, an intensive SR & T program has been initiated which builds on previous work and is coordinated with work in other agencies. The primary areas of concern are detectors, on-board computers, and ultraviolet optical components. In the last area grating work is being emphasized. The on-board computer will be necessary to allow pre-processing of raw data and enable detector operation in a pulse counting mode. For detectors, the SEC Vidicon development will be continued but the use of solid-state arrays in the electron bombarded mode and channel plate detectors are being seriously considered. One challenging problem is to provide 2 K cooling to permit ultra-sensitive IR observations to be made.

Sobieski, S.↗

Airborne imaging spectrometer II - The optical design

The Airborne Imaging Spectrometer (AIS I) was a multispectral infrared imaging instrument utilizing a 32 x 32 element mercury-cadmium-telluride detector array. A novel optical design provided high spectral resolution and, in conjunction with the 32-element spatial resolution, made optimal use of the capabilities of the area array. The operational successes of this proof-of-concept instrument, coupled with advances in infrared detector array technology, have provided the impetus and opportunity to upgrade the instrument by replacing the sensor with a newly developed 64 x 64 detector. The original instrument configuration is reviewed, and the design considerations, limitations and trade-offs necessitated by the new detector are examined, particularly the near doubling of the field of view and the increase from 1024 to 4096 pixels per read-out frame.

La Baw, Clayton↗

(abstract) JPL Cryocooler Development and Test Program Overview

Many near-term and future space-instrument programs within NASA and the Ballistic Missile Defense Organization (BMDO) depend on the successful development of long-life, low-vibration space cryocoolers. The most demanding near-term programs include a number of science instruments selected for NASA's Earth Observing System (Eos) program, and a number of space reconnaissance instruments associated with the BMDO's Brilliant Eyes program; both of these programs require delivery of similar types of flight coolers in the next few years. To help ensure the success of these cooler commitments, JPL has implemented an extensive cryocooler program in support of the NASA/JPL AIRS project, the Air Force Phillips Laboratory (AFPL), and the Air Force Space and Missiles Systems Division (SMC). This program is directed at assisting industry in developing advanced cryocoolers that successfully address the broad array of complex performance requirements needed for NASA and BMDO long-life space instruments. The JPL cryocooler program includes extensive characterization and life testing of industry-developed cryocoolers, development and flight testing of advanced sorption cooler systems for detector cooling to 10 K , development of mechanical cryocooler enhancement technologies, and flight tests of advanced low-vibration Stirling-cooler systems.

development design testing↗

Split-Block Waveguide Polarization Twist for 220 to 325 GHz

A split-block waveguide circuit that rotates polarization by 90 has been designed with WR-3 input and output waveguides, which are rectangular waveguides used for a nominal frequency range of 220 to 325 GHz. Heretofore, twisted rectangular waveguides equipped with flanges at the input and output have been the standard means of rotating the polarizations of guided microwave signals. However, the fabrication and assembly of such components become difficult at high frequency due to decreasing wavelength, such that twisted rectangular waveguides become impractical at frequencies above a few hundred gigahertz. Conventional twisted rectangular waveguides are also not amenable to integration into highly miniaturized subassemblies of advanced millimeter- and submillimeter-wave detector arrays now undergoing development. In contrast, the present polarization- rotating waveguide can readily be incorporated into complex integrated waveguide circuits such as miniaturized detector arrays fabricated by either conventional end milling of metal blocks or by deep reactive ion etching of silicon blocks. Moreover, the present split-block design can be scaled up in frequency to at least 5 THz. The main step in fabricating a splitblock polarization-rotating waveguide of the present design is to cut channels having special asymmetrically shaped steps into mating upper and lower blocks (see Figure 1). The dimensions of the steps are chosen to be consistent with the WR-3 waveguide cross section, which is 0.864 by 0.432 mm. The channels are characterized by varying widths with constant depths of 0.432, 0.324, and 0.216 mm and by relatively large corner radii to facilitate fabrication. The steps effect both a geometric transition and the corresponding impedance-matched electromagnetic-polarization transition between (1) a WR-3 rectangular waveguide oriented with the electric field vector normal to the block mating surfaces and (2) a corresponding WR-3 waveguide oriented with its electric field vector parallel to the mating surfaces of the blocks. A prototype has been built and tested. Figure 2 presents test results indicative of good performance over nearly the entire WR-3 waveguide frequency band.

Ward, John↗

OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. A preliminary estimate of the decay timescale for one detector is that a drop of 0.1-0.2% occurs over a ten day period, indicating that relatively infrequent cal lamp exposures can mitigate the behavior to extremely low levels.

Collins, Nick↗