In situ object counting system (ISOCSi3T{sup M}) technique: A cost-effective tool for NDA verification in IAEA Safeguards

Nuclear material measurements using the ISOCS technique are playing an increasing role in IAEA verification activities. The ISOCS capabilities include: a high sensitivity to the presence of U and Pu; the ability to detect very small amounts of material; and the ability to measure items of different shapes and sizes. In addition, the numerical absolute efficiency calibration of a germanium detector used in the technique does not require any calibration standards or reference materials. The ISOCS modelling software performs an absolute efficiency calibration for items with various container shapes, container wall materials, material compositions, material fill-heights, U/Pu weight fractions and even heterogeneously distributed emitting materials. In a number of cases, some key parameters, such as the matrix density and U/Pu weight fraction, can be determined in addition to the emitting material mass and isotopic composition. These capabilities provide a verification solution suitable for a majority of cases where quantitative and isotopic analysis should be performed. Taking into account these advantages, the technique becomes a cost-effective solution for nuclear material non-destructive assay (NDA) verification. At present, the IAEA uses the ISOCS for a wide range of applications including the quantitative analysis of U scrap materials, U/Pu contaminated solid wastes, U fuel elements, U hold-up materials. Additionally, the ISOCS is also applied to some specific verification cases such as the measurement of PuBe neutron sources and the quantification of fission products in solid wastes. In reprocessing facilities with U/Pu waste compaction or facilities with item re-batching, the continuity-of-knowledge can be assured by applying either video surveillance systems together with seals (requiring attaching/detaching and verification activities for each seal) or verification of operator declarations using quantitative measurements for items selected on a random basis. In some cases, the first option is too expensive and places a high demand on inspector and operator time. Quantitative NDA based on the ISOCS technique verifies these materials and significantly decreases the resources required for assuring the continuity-of-knowledge. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Meso-scale magnetic signatures for nuclear reactor steel irradiation embrittlement monitoring

Verifying the structural integrity of passive components in light water and advanced reactors will be necessary to ensure safe, long-term operations of the existing U.S. nuclear fleet. This objective can be achieved through nondestructive condition monitoring techniques, which can be integrated with plant operations to quantify the “state of health” of structural materials in real-time. While nondestructive methods for monitoring many classes of degradation (such as fatigue or stress corrosion cracking) are relatively advanced, this is not the case for degradation caused by irradiation. The development of nondestructive evaluation technologies for these types of degradation will require advanced materials characterization techniques and tools that enable comprehensive understanding of nuclear reactor material microstructural and behavioral changes under extreme operating environments. Irradiation-induced degradation of reactor steels causes changes in their microstructure that impacts their micro-magnetic properties. In this paper, we describe preliminary results of integrating advanced material characterization techniques with meso-scale computational models. In the future, this will help to provide an interpretive understanding of the state of degradation in structural materials. Microstructural data are presented from monocrystalline Fe and are correlated with variable-field magnetic force microscopy and micro-magnetic measurements. Ongoing research is focused on extending the measurements and models on thin films to gain insights into the structural state of irradiated materials and the resulting impact on magnetic properties. Preliminary conclusions from these correlations are presented, and next steps described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3 ) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235 U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in Autoradiography Systems for Nuclear Forensic Analysis

Nuclear forensic analysis techniques work to determine the contents of radiological samples with nondestructive and destructive analysis methods. Autoradiography is a nondestructive analysis method that creates an image of the distribution of radioactivity within the sample. These images allow the location of the radiological content within a sample to be ascertained, which can be used for further analysis. Autoradiography has been used since the discovery of radiation and has been continuously developed to better suit the needs of the medical, nuclear security, nuclear safeguards, and nuclear forensic communities. Recent developments in autoradiography have led to a higher spatial resolution down to a level of tens of microns, real-time capabilities that minimize the risk of overexposure, and the ability to discriminate particles. All of these developments in autoradiography would assist the nuclear forensics community in understanding the placement of radiological content within a sample and in understanding the locations of beta-particle interactions versus those for alpha-particle interactions. This article aims to discuss the history of autoradiography as well as multiple different autoradiographic technologies while focusing on imaging plates, the BeaQuant system, and the ionizing-radiation Quantum Imaging Detector system. This article reviews three autoradiographic techniques and detectors, discusses how they relate to nuclear forensics, and addresses the drawbacks and benefits of each detector.

Autoradiography↗

X-ray tomographic in-service inspection of girth welds - The European project TomoWELD

The new standard 'ISO 17636-2:2013: Non-destructive testing of welds - Radiographic testing - Part 2: X- and gamma-ray techniques with digital detectors', defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined.

36 MATERIALS SCIENCE↗

Broadband Achromatic Phase Shifter for a Nulling Interferometer

Nulling interferometry is a technique for imaging exoplanets in which light from the parent star is suppressed using destructive interference. Light from the star is divided into two beams and a phase shift of radians is introduced into one of the beams. When the beams are recombined, they destructively interfere to produce a deep null. For monochromatic light, this is implemented by introducing an optical path difference (OPD) between the two beams equal to lambda/2, where lambda is the wavelength of the light. For broadband light, however, a different phase shift will be introduced at each wavelength and the two beams will not effectively null when recombined. Various techniques have been devised to introduce an achromatic phase shift a phase shift that is uniform across a particular bandwidth. One popular technique is to use a series of dispersive elements to introduce a wavelength-dependent optical path in one or both of the arms of the interferometer. By intelligently choosing the number, material and thickness of a series of glass plates, a nearly uniform, arbitrary phase shift can be introduced between two arms of an interferometer. There are several constraints that make choosing the number, type, and thickness of materials a difficult problem, such as the size of the bandwidth to be nulled. Several solutions have been found for bandwidths on the order of 20 to 30 percent (Delta(lambda)/lambda(sub c)) in the mid-infrared region. However, uniform phase shifts over a larger bandwidth in the visible regime between 480 to 960 nm (67 percent) remain difficult to obtain at the tolerances necessary for exoplanet detection. A configuration of 10 dispersive glass plates was developed to be used as an achromatic phase shifter in nulling interferometry. Five glass plates were placed in each arm of the interferometer and an additional vacuum distance was also included in the second arm of the interferometer. This configuration creates a phase shift of pi radians with an average error of 5.97 x 10(exp -8) radians and standard deviation of 3.07 x 10(exp -4) radians. To reduce ghost reflections and interference effects from neighboring elements, the glass plates are tilted such that the beam does not strike each plate at normal incidence. Reflections will therefore walk out of the system and not contribute to the intensity when the beams are recombined. Tilting the glass plates, however, introduces several other problems that must be mitigated: (1) the polarization of a beam changes when refracted at an interface at non-normal incidence; (2) the beam experiences lateral chromatic spread as it traverses multiple glass plates; (3) at each surface, wavelength- dependent intensity losses will occur due to reflection. For a fixed angle of incidence, each of these effects must be balanced between each arm of the interferometer in order to ensure a deep null. The solution was found using a nonlinear optimization routine that minimized an objective function relating phase shift, intensity difference, chromatic beam spread, and polarization difference to the desired parameters: glass plate material and thickness. In addition to providing a uniform, broadband phase shift, the configuration achieves an average difference in intensity transmission between the two arms of the interferometer of 0.016 percent with a standard deviation of 3.64 x 10(exp -4) percent, an average difference in polarization between the two arms of the interferometer of 5.47 x 10(exp -5) percent with a standard deviation of 1.57 x 10(exp -6) percent, and an average chromatic beam shift between the two arms of the interferometer of -47.53 microns with a wavelength-by-wavelength spread of 0.389 microns.

Bolcar, Matthew R.↗

Status Report on Photothermal Radiometry Development

Thermal transport properties such as thermal conductivity and diffusivity, are critical parameters in the development of improved nuclear fuels and components. It is well known that thermal transport properties change temporally and spatially due to dynamic microstructural evolution as a result of neutron irradiation. Laser based photothermal techniques are an ideal candidate for thermal properties measurement of irradiated materials because they are non contact, non destructive and can be performed remotely. In this report, we present the progress in the development of a photothermal radiometry (PTR) system to measure the thermal diffusivity of solid samples. The PTR technique measures the local temperature response from a modulated heat source by detecting the sample radiation heat flux. Initially, a well developed thermal wave analytical model was fit to the data to obtain the thermal diffusivity. However, systematic errors from the diffraction effect and non linearity issues resulted in thermal diffusivity measurements higher than literature values. These effects have been studied, an improved analytical model has been developed, and the physics behind the phenomena are still under investigation. A procedure for optimizing measurements from the benchtop system has been provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Method For The Verification Of Wire Crimp Compression Using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to assess quantitatively wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating at right angles to the wire axis and through the junction of a crimp termination is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. To demonstrate the technique, the case of incomplete compression of crimped connections is ultrasonically tested, and the results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently predicts good crimps when the ultrasonic transmission is above a certain threshold amplitude level. A quantitative measure of the quality of the crimped connection based on the ultrasonic energy transmitted is shown to respond accurately to crimp quality. A wave propagation model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. A comparison of the results of two different instruments is presented and shows reproducibility between instruments within a 95% confidence bound.

Cramer, K. E.↗

Analysis of electrically conductive adhesives in shingled solar modules by X-ray imaging techniques

The failure mechanisms of electrically conductive adhesives (ECAs) in solar modules are difficult to study since the ECA layer is not easily accessible within the module package. In this work, we present two complementary imaging modalities—X-ray radiography and X-ray microcomputed tomography (XCT)—that reveal important morphological features of the ECA within a shingled module. X-ray radiography uses single X-ray projections to provide fast and non-destructive imaging of the shingled interconnection, illuminating the alignment of the ECA relative to the busbars, the size and shape of the ECA, and the presence of voids within it. Through X-ray radiography, we observed, for example, that the average void coverage area of ECA segments reduced from 36.7% to 4.4% when an ECA was cured for 60 s prior to module lamination. XCT is a three-dimensional imaging technique that can identify regions in which the ECA makes electrical contact to busbars on cells and regions in which the ECA has cracked, among other features. XCT can also be used to image the individual metal particles within ECA, from which the metal volume fraction of an ECA was found here to be 70.4%. This is a quantity that is not often reported by ECA manufacturers but is important to ensure isotropic conduction. As X-ray projections can be performed non-destructively on full modules, the technique may be used to pinpoint ECA failures in accelerated degradation testing. XCT is complementary and is suited to forensic analysis of failing modules.

14 SOLAR ENERGY↗

Non-destructive Faraday imaging of dynamically controlled ultracold atoms

We describe an easily implementable method for non-destructive measurements of ultracold atomic clouds based on dark field imaging of spatially resolved Faraday rotation. The signal-to-noise ratio is analyzed theoretically and, in the absence of experimental imperfections, the sensitivity limit is found to be identical to other conventional dispersive imaging techniques. The dependence on laser detuning, atomic density, and temperature is characterized in a detailed comparison with theory. Due to low destructiveness, spatially resolved images of the same cloud can be acquired up to 2000 times. The technique is applied to avoid the effect of shot-to-shot fluctuations in atom number calibration, to demonstrate single-run vector magnetic field imaging and single-run spatial imaging of the system's dynamic behavior. This demonstrates that the method is a useful tool for the characterization of static and dynamically changing properties of ultracold atomic clouds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct observations and characterization of crack closure during microstructurally small fatigue crack growth via in-situ high-energy X-ray characterization

This study provides direct observation of the crack closure mechanism of a naturally occurring, tortuous, 3D microstructurally small fatigue crack (SFC) in additively manufactured Inconel 718. In-situ non-destructive characterization is performed using high-energy X-ray diffraction techniques to capture the evolution of the 3D microstructure and micromechanical response in the vicinity of the crack front. Based on the stress state of twelve grains analyzed at the crack tip, the crack closure events of the SFC front was found to be spatially heterogeneous with respect to loading progression governed by the local stress state of the grains (specifically the stress reversal from compression to tension). From this analysis, three grains that displayed different degrees of crack closure were further investigated, based on the orientation of the crack relative to the grains and the associated modality of crack growth. The stress normal to the crack plane and the associated degree of Mode I crack behavior were correlated with events of the crack opening earlier during the loading cycle. This was further corroborated by diffraction spot spreading analysis that quantified the crystallographic lattice distortion caused by the opening crack. Additionally, the detailed characterization of the opening behavior of the grains located at the crack tip and their associated states of stress elucidates the mechanism governing crack closure and will inform future modeling efforts of this phenomenon.

36 MATERIALS SCIENCE↗

Quantitative and qualitative bone imaging: A review of synchrotron radiation microtomography analysis in bone research

All levels of the unique hierarchical structure of bone, consisting of collagen and hydroxyapatite crystals at the nanoscale to osteon/lamellae structures at the microscale, contribute to its characteristic toughness and material properties. Elements of bone's density and size contribute to bone quantity (or bone mass), whereas elements of bone's material composition, material properties, internal structure, and organization describe bone quality. Furthermore, bone quantity and quality can be degraded by factors such as aging, disease, treatments, and irradiation, compromising its ability to resist fracture and sustain loading. Accessing the morphology and architecture of bone at the microscale to quantify microstructural features and assess the degree of mineralization and path of crack propagation in bone provides crucial information on how these factors are influencing bone quantity and quality. Synchrotron radiation micro-computed tomography (SRμCT) was first used to assess bone structure at the end of the 1990's. One of the main advantages of the technique is that it enables accurate three-dimensional (3D), non-destructive quantification of structure while traditional histomorphometry on histological sections is inherantly destructive to the sample and two-dimensional (2D). Additionally, SRμCT uses monochromatic, high-flux X-ray beams to provide high-resolution and high-contrast imaging of bone samples. This allows the quantification of small microstructural features (e.g. osteocyte lacunae, canals, trabeculae, microcracks) and direct gray value compositional mapping (e.g. mineral quantification, cement lines) with greater speed and fidelity than lab-based micro-computed tomography. In this article, we review how SRμCT has been applied to bone research to elucidate the mechanisms by which bone aging, disease, and other factors affect bone fragility and resistance to fracture.

60 APPLIED LIFE SCIENCES↗

Extracting Optical Bandgaps from Luminescence Images of Perovskite Solar Cells

We report a camera-based method to capture optical bandgap images of perovskite solar cells (PSCs). It is fast and non-destructive. It can also provide micron-scale spatial resolution. This imaging technique utilizes well-defined and relatively symmetrical band-to-band luminescence spectra emitted from perovskite materials. Their spectra can be fitted with Gaussian functions whose peak locations are similar to absorption thresholds and thus represent the material optical bandgaps. We apply the technique to resolve relative variations in optical bandgaps across various PSCs, and to show optical bandgap inhomogeneity within the same device due to material degradation and impurities. Degradation and impurities were found to both cause optical bandgap shifts inside the materials. Our results are independently confirmed with photoluminescence and absorption spectroscopy.

14 SOLAR ENERGY↗

Radiation Monitoring for Volatilized Zinc Contamination Using Gamma-Ray Imaging and Spectroscopy

Gamma-ray imaging is a tool that has grown in importance in the applications of non-destructive assay (NDA) for radioactive survey and analysis of nuclear facilities. Imaging techniques have shown great promise in providing valuable information involving radioactive waste management and contamination prevention. For the application studied in this work, 65 Zn has been identified as a radioactive contaminant during tritium extraction. Due to the volatile nature of 65 Zn under the pressure and temperature changes during extraction operations, 65 Zn can easily travel through components of the extraction system as vapor, making it difficult to trap. Previous research involving the development of a filtration system showed that the 65 Zn can be trapped, mitigating product contamination. However, during the extraction process, direct analysis of the equipment to confirm that zinc contamination is trapped in the filter and has not spread to other components is impractical. Here, in this situation, the need to assay the location of the contamination with little-to-no interference with operations is vital. In this work, we demonstrate the use of a commercialized 3D position-sensitive CdZnTe (CZT) gamma-ray imaging spectrometer to provide analysis of the 65 Zn contamination. Onsite measurements during an extraction process are studied to assess the location and migration of the 65 Zn. The results obtained from real-time glovebox monitoring demonstrate the feasibility of gamma-ray imaging for localizing the contamination and providing a preliminary qualitative assessment that is intended to be used in future work quantifying the contamination build-up and activity over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging transient solidification behavior

Solidification processing offers the first opportunity to control microstructure, properties, and performance in metallic alloy components. Until recently, microstructural evaluations were limited to post-solidification characterization by destructive methods. We review the development of time-resolved, in situimaging techniques capable of capturing solid-liquid interfacial evolution in metallic alloys with high spatial and temporal resolution underdiverse solidification conditions relevant for applications ranging from conventional directional solidification, crystal growth, and casting,to welding and additive manufacturing. These experiments enable direct visualization of transient behaviors that would otherwise remain unknown, uniquely providinginsights into the physics that impact microstructure and defect development and strategies for microstructuralcontrol and defect mitigation. Understanding microstructural evolution and the characteristics that form under various solidification conditions is essential for the development of multiscale, experimentallyinformed predictive modeling. This is highlightedby solidification simulations that utilize in situmeasurements of solidification dynamics from state-of-the-art experimental techniques.

36 MATERIALS SCIENCE↗

Structural analysis of an ancient pottery by using FT-IR technique

Pottery artifacts are one of the most abundant findings among archaeological artifacts and their analysis can reveal information regarding daily life of that society. The composition of the artifact can be correlated to the age in which it was created. The authenticity of the artifact is also important. Forgers can “touch up” artifacts to make them appear original. FT-IR is a useful method to investigate the structure, bonding and chemical properties of materials and is used for the analysis of art and historical objects in support of efforts to conserve, restore, and validate authenticity of these rare objects. Generally, the minerals found in the pottery can be classified into primary minerals, firing minerals, and secondary minerals. The identification of firing minerals is essential requirement for the clarification of firing temperature which provides understanding of the civilization that created the potteries. Qualitative and also quantitative techniques such as XRD and bench top FTIR spectrometers are often not destructive but require a small amount of the sample to be separated from the material, in this case artifact. On the other hand, hand held FT-IR offers a method that is not invasive. The piece of the pottery used in the present study is shown in fig.1. The pot contains black, white, and brown decorations. The areas analyzed were mapped over the different colored decorations. This was done to determine the consistency of the composition of the pot. This can ultimately be used to determine if the pot was made at the same time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microstructure Experiments-Enabled MARMOT Simulations of SiC/SiC-based Accident Tolerant Nuclear Fuel System

We have undertaken an experimental-computational project that addresses a few key technology gaps associated with the use of SiC/SiC composites for light water reactor fuel cladding. Two principal endeavors in this project are to assess the irradiation-induced microstructural changes and swelling in SiC/SiC composites, and to characterize and model the porous oxide surface layer (when exposed to steam) along SiC recession that is detrimental to the clad integrity under accident conditions. The project tasks are: (i) ion irradiation and characterization (University of Tennessee, Knoxville), (ii) mechanical tests and analysis (University of South Carolina), (iii) steam exposure tests (Oak Ridge National Laboratory), (iv) electron microscopy and spectroscopic characterization (NC State University), (v) x-ray microscopy and reconstruction (University of South Carolina and NC State University), (vi) phase field modeling and simulations (NC State University and Idaho National Laboratory). The effects of 10 MeV Au ion irradiation at 350°C on the microstructure evolution in SiC/SiC composites are investigated at doses up to 400 displacements per atom (dpa) at the University of Tennessee, Knoxville. Atomic force microscopy and optical profilometry reveal irradiation induced axial and radial shrinkage of the fibers for doses greater than 10 dpa. Based on detailed electron microscopy characterization, the primary cause of the fiber shrinkage is attributed to irradiation-induced loss of carbon packets. Additionally, the multilayer PyC interface is observed to portray high resistance to irradiation damage. The mechanical response and failure mechanisms of un-irradiated samples is also assessed through loading tests and X-ray imaging at the University of South Carolina. Steam exposure tests are performed at the Oak Ridge National Laboratory in a facility that represents a reactor pressure vessel under a loss-of-coolant-accident scenario. The samples that are analyzed methodically in this report are tested for 32/31 hours at 1200°C with a velocity of 0.25 cm/s for the pressures: 0.1 MPa, 0.45 MPa, 0.92 MPa and 1.38 MPa. Scanning/transmission electron microscopy analysis conducted at the NC State University (NCSU) shows that the oxide layer thickness increases with the steam pressure. While the oxide layer is crystalline (α- cristobalite) for the pressures 0.45 MPa, 0.92 MPa and 1.38 MPa, the layer is amorphous at 0.1 MPa. Results from Raman spectroscopy have also confirmed the formation of α-cristobalite phase of SiO₂. The abrupt increase in the integrated Raman intensity ratio between steam pressures 0.1 and 0.45 MPa suggests the onset of accelerated crystallization. Non-destructive three dimensional X-ray microscopy/tomography (XCT) and computational image processing techniques are employed by the University of South Carolina to probe the porous oxidation features on SiC samples at varying pressures. Interestingly, most pores are observed to be located away from the surface as well as the oxide-SiC interface. The average oxide layer thickness assessed from the XCT analysis is seen to be in excellent agreement with the values determined through scanning electron microscopy analysis for the highest pressures where the oxide layer is relatively more uniform. A phase-field model developed by the NC State University and Idaho National Laboratory for simulating oxidation of SiC by steam captures the paralinear kinetics of SiC oxidation with a high degree of fidelity. Results from quasi-one-dimensional and two dimensional simulations show that the pores with oxidizing species lead to a higher volatilization rate. These simulations indicate that the enhanced apparent volatilization rates at higher pressures observed in experiments can be rationalized by the increased volatilization from the pores. The project team has also successfully developed the capability to import images from experiments for realistic evolution of the oxidizing microstructure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗