Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “depth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Primary and secondary particle contributions to the depth dose distribution in a phantom shielded from solar flare and Van Allen protons

Calculations have been made using the nucleon-meson transport code NMTC to estimate the absorbed dose and dose equivalent distributions in astronauts inside space vehicles bombarded by solar flare and Van Allen protons. A spherical shell shield of specific radius and thickness with a 30-cm-diam. tissue ball at the geometric center was used to simulate the spacecraft-astronaut configuration. The absorbed dose and the dose equivalent from primary protons, secondary protons, heavy nuclei, charged pions, muons, photons, and positrons and electrons are given as a function of depth in the tissue phantom. Results are given for solar flare protons with a characteristic rigidity of 100 MV and for Van Allen protons in a 240-nautical-mile circular orbit at 30 degree inclination angle incident on both 20-g/sq cm-thick aluminum and polyethylene spherical shell shields.

Santoro, R. T.↗

Microwave properties of geological materials: Studies of penetration depth and moisture effects

Summarized are the results of two of a series of controlled experiments performed during the summer of 1970. The first series of experiments to determine penetration depth showed the value of having a modeled response and data reduced in real time for examination in the field. The results suggest a radiometric method for measuring the microwave properties of materials in bulk and are applicable to studies of sea ice and other naturally layered media. The sensitivity of the microwave emission to changes in moisture content has inspired a number of airborne and ground based investigations. Although the effect is dominent under certain conditions, the complicating factors of soil type, roughness, vegetation, etc. seem to govern the conclusions regarding its application at this time.

Blinn, J. C., III↗

Height-depth ratios of lunar and terrestrial craters.

Quantitative analysis of Gilbert's (1893) observation regarding the surface geometry of lunar craters and terrestrial calderas. Topographic measurements were made using the ratio of exterior rim height to interior crater depth, and then extended to other types of crater. The morphometric data obtained as well as those presented elsewhere (Murray et al., 1970; Guest and Murray, 1969) verify Gilbert's contention that terrestrial calderas and most rimmed lunar craters are entirely unrelated phenomena. Auxiliary characteristics previously interpreted in terms of primary volcanic cratering on the moon are either of nonendogenic origin or are secondary endogenic features superposed on initial impact landforms (Pike, 1967).

Pike, R. J.↗

EEG monitoring of a free-swimming diver at a working depth of 15 meters.

Feasibility has been shown for underwater transmission of physiological signals, using frequency modulation of carriers transmitted by return-current-density methods, as part of a personal biotelemetry system. In the prototype system, a standard IRIG subcarrier frequency (2300 Hz) was used. Power requirements, antenna design, and signal attenuation are compatible with free-ranging diving activity at distances up to 15 meters from the receiver. Extrapolation from this study and further developments are expected to substantially increase the range. Advantages of this system include subcarrier compatibility with standard IRIG demodulators using channels 1 through 10, the absence of highly specialized antenna requirements, and reasonable attenuation characteristics for transmission through the turbidity of typical seawater. Moreover, the system would not appear to be depth limited, and to be compatible with use of high-powered transponders of the same type for long-distance transmission, with or without further encoding.

Zweizig, J. R.↗

Effects of voluntary eye movement and convergence on the binocular appreciation of depth.

Scaling techniques were employed to establish the relation between perceived distance ratio and physical distance ratio. Measurements were made both with and without free eye movement and under two states of convergence. The results were confirmed using a matching technique. With free eye movement, the perceived ratio is a monotonic increasing function of the physical ratio. Without eye movement, the perceived ratio generally increases, then decreases, as the physical ratio increases. For a given physical ratio, perceived distance ratio is less in the absence of voluntary eye movements. Convergence produces depth micropsia when eye movements are permitted, but not in their absence.

Foley, J. M.↗

Determining optical depth in different parts of the Fraunhofer line contour

The method of approximate determination of the optical depth tau in the profile of the Fraunhofer line is considered. In the method the observed profile and allocation of tau to the temperature in the photosphere must be known. If the source function B prime (tau) in the line seems not to be equal to the Planck function, the dependence B prime (tau) on tau is needed. The method for the determination of B prime (tau) using the center-to-limb observations of the central intensities of the line is suggested.

Gurtovenko, E. A.↗

Auger electron spectroscopy and depth profile study of oxidation of modified 440C steel

Auger electron spectroscopy (AES) and sputtering were used to study selective oxidation of modified 440C steel. The sample was polycrystalline. Oxidation was performed on initially clean surfaces for pressures ranging from 1 x 10 to the minus 7th power to 1 x 10 to the minus 5th power torr and temperatures ranging from room temperature to 800 C. AES traces were taken during oxidation. In situ sputtering depth profiles are also obtained. A transition temperature is observed in the range 600 to 700 C for which the composition of the outer surface oxide changed from iron oxide to chromium oxide. Heating in vacuum about 5 x 10 to the minus 10 power torr to 700 C causes conversion of the iron oxide surface to chromium oxide.

Ferrante, J.↗

Extracting depth information from a stereo pair

An approach to extracting depth information out of a stereo pair of images is described. Special camera pair configurations are shown to be effective in reducing complexity. A simple algorithm which pairs objects in the two images and allows verification is described.

Yakimovsky, Y.↗

Effects of inlet treatment location and treatment cavity depth on compressor noise

The ability of acoustic liners to reduce compressor noise inside and in front of an inlet was studied. An axial flow research compressor and a specially designed inlet were used inside an anechoic chamber. Acoustic and performance data were obtained for a range of inlet treatment locations and cavity depths to determine their effects on inlet noise over a range of blade passing frequencies. The greatest noise reductions in front of the inlet were obtained with acoustic treatment located close to the compressor and backed with the deepest cavities tested. Inside the inlet the maximum noise level reductions were obtained in the area of the treatment regardless of treatment location. No appreciable losses in compressor performance were measured.

Clark, L. R.↗

Lunar crater depths from Orbiter IV long-focus photographs

Determination of the depths of more than 1900 small lunar craters from measures of shadows on the long-focus pictures obtained by Lunar Orbiter IV. The method for converting the measured shadow length into the true length in nature of the shadow hypotenuse is new and is applicable to other planetary bodies, provided that comparable spacecraft ephemerides are available. The measures were made with a simple surveyor's plotting scale on the standard Orbiter IV photographic enlargements. The results indicate that the smaller lunar (D less than 30 km) crater are appreciably deeper than is indicated by earlier work using imagery obtained at terrestrial observatories.

Arthur, D. W. G.↗

Laser measure of sea salinity, temperature and turbidity in depth

A method is described in which a pulsed laser is used to probe the sea. Backscattered light is analyzed in time, intensity and wavelength. Tyndall, Raman and Brillouin scattering are used to obtain the backscatter turbidity, sound velocity, salinity, and the temperature as a function of depth.

Hirschberg, J. G.↗

Electro-optical liquid depth sensor

Transducer utilizes absorptive properties of water to determine variations in depth without disturbing liquid. Instrument is inexpensive, simple, and small and thus can be used in lieu of direct graduated scale readout or capacitive, ultrasonic, resistive or inducive sensors when these are impractical because of complexity or cost.

Heppner, D. B.↗

An elementary theory of eclipsing depths of the light curve and its application to Beta Lyrae

An elementary theory of the ratio of depths of secondary and primary eclipses of a light curve has been proposed for studying the nature of component stars. It has been applied to light curves of Beta Lyrae in the visual, blue, and far-ultraviolet regions with the purpose of investigating the energy sources for the luminosity of the disk surrounding the secondary component and determining the dominant radiative process in the disk. No trace of the spectrum of primary radiation has been found in the disk. Therefore, it is suggested that LTE is the main radiative process in the disk, which radiates at a temperature of approximately 12,000 K in the portion that undergoes eclipse. A small source corresponding to 14,500 K has also been tentatively detected and may represent a hot spot caused by hydrodynamic flow of matter from the primary component to the disk.

Huang, S.-S.↗