Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

A direct electron detector for time-resolved MeV electron microscopy

The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here in this paper, we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μm spatial resolution and less than 20 analogue-to-digital converter count RMS pixel noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.

36 MATERIALS SCIENCE↗

Experimental Measurements of Short-Lived Fission Products from Uranium, Neptunium, Plutonium and Americium

Fission yields are especially well characterized for long-lived fission products. Modeling techniques incorporate numerous assumptions and can be used to deduce information about the distribution of short-lived fission products. This work is an attempt to gather experimental (model-independent) data on the short-lived fission products. Fissile isotopes of uranium, neptunium, plutonium and americium were irradiated under pulse conditions at the Washington State University 1 MW TRIGA reactor to achieve ~108 fissions. The samples were placed on a HPGe (high purity germanium) detector to begin counting in less than 3 minutes post irradiation. The samples were counted for various time intervals ranging from 5 minutes to 1 hour. The data was then analyzed to determine which radionuclides could be quantified and compared to the published fission yield data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A GAMMA RAY SCANNING APPROACH TO QUANTIFY SPENT FUEL CASK RADIONUCLIDE CONTENTS

The International Atomic Energy Agency (IAEA) has outlined a need to develop methods of allowing re-verification of LWR spent fuel stored in dry storage casks without the need of a reference baseline measurement. Some scanning methods have been developed, but improvements can be made to readily provide required data for spent fuel cask verification. The scanning process should be conditioned to both confirm the contents and detect any changes due to container/contents degradation or unauthorized removal or tampering. Savannah River National Laboratory and The University of Tennessee are exploring a new method of engineering a high efficiency, cost effective detection system, capable of meeting the above defined requirements in a variety of environmental situations. An array of NaI(Tl) detectors, arranged to form a 'line scan' along with a matching array of 'honeycomb' collimators provide a precisely defined field of view with minimal degradation of intrinsic detection efficiency and with significant scatter rejection. Scanning methods are adapted to net optimum detection efficiency of the combined system. In this work, and with differing detectors, a series of experimental demonstrations are performed that map system spatial performance and counting capability before actual spent fuel cask scans are performed. The data are evaluated to demonstrate the prompt ability to identify missing fuel rods or other content abnormalities. To also record and assess cask tampering, the cask is externally examined utilizing FTIR hyper spectral and other imaging/sensing approaches. This provides dated records and indications of external abnormalities (surface deposits, smears, contaminants, corrosion) attributable to normal degradation or to tampering. This paper will describe the actual gathering of data in both an experimental climate and from an actual spent fuel dry storage cask, and how an evaluation may be performed by an IAEA facility inspector attempting to draw an independent safeguards conclusion concerning the status of the special nuclear material.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mercat

Mercat is a highly scalable property software package for robust of analysis of features in next-generation sequencing data and observed unique peptides from metaproteomic data. Mercat is offered in python 3.5/anaconda3, is multiparellel and is easily installed using bioconda/conda recipes. Mercat inputs include assembled contigs, raw sequence reads from any platform, and unique peptide files obtained from proteomics with feature abundance counts tables. Mercat is the only software available that allows for direct analysis of data properties without a data-dependent search tools such as BLAST or diamond for compositional analysis of whole community shotgun sequencing (e.g. metagenomes and/or metatranscriptomes) or metaproteomic data.

Source record↗

Mercat

Mercat is a highly scalable property software package for robust of analysis of features in next-generation sequencing data and observed unique peptides from metaproteomic data. Mercat is offered in python 3.5/anaconda3, is multiparellel and is easily installed using bioconda/conda recipes. Mercat inputs include assembled contigs, raw sequence reads from any platform, and unique peptide files obtained from proteomics with feature abundance counts tables. Mercat is the only software available that allows for direct analysis of data properties without a data-dependent search tools such as BLAST or diamond for compositional analysis of whole community shotgun sequencing (e.g. metagenomes and/or metatranscriptomes) or metaproteomic data.

Source record↗

Using Process Load Cell Information for IAEA Safeguards at Enrichment Plants

Uranium enrichment service providers are expanding existing enrichment plants and constructing new facilities to meet demands resulting from the shutdown of gaseous diffusion plants, the completion of the U.S.-Russia highly enriched uranium downblending program, and the projected global renaissance in nuclear power. The International Atomic Energy Agency (IAEA) conducts verification inspections at safeguarded facilities to provide assurance that signatory States comply with their treaty obligations to use nuclear materials only for peaceful purposes. Continuous, unattended monitoring of load cells in UF{sub 6} feed/withdrawal stations can provide safeguards-relevant process information to make existing safeguards approaches more efficient and effective and enable novel safeguards concepts such as information-driven inspections. The IAEA has indicated that process load cell monitoring will play a central role in future safeguards approaches for large-scale gas centrifuge enrichment plants. This presentation will discuss previous work and future plans related to continuous load cell monitoring, including: (1) algorithms for automated analysis of load cell data, including filtering methods to determine significant weights and eliminate irrelevant impulses; (2) development of metrics for declaration verification and off-normal operation detection ('cylinder counting,' near-real-time mass balancing, F/P/T ratios, etc.); (3) requirements to specify what potentially sensitive data is safeguards relevant, at what point the IAEA gains on-site custody of the data, and what portion of that data can be transmitted off-site; (4) authentication, secure on-site storage, and secure transmission of load cell data; (5) data processing and remote monitoring schemes to control access to sensitive and proprietary information; (6) integration of process load cell data in a layered safeguards approach with cross-check verification; (7) process mock-ups constructed to provide simulated load cell data; (8) hardware and software implementation for process load cell data collection; (9) costs associated with unattended monitoring of load cells (for both operator and inspector) weighed against the potential benefits of having access to such data; (10) results from field tests of load cell data collection systems in operating facilities; and (11) use of unattended load cell data to increase efficiency of on-site inspection schedules and activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data-optimized source modeling with the Backwards Liouville Test–Kinetic method

In the standard practice of neutron multiplicity counting , the first three sampled factorial moments of the event triggered neutron count distribution were used to quantify the three main neutron source terms: the spontaneous fissile material effective mass, the relative (α,n) production and the induced fission source responsible for multiplication. Our study compares three methods to quantify the statistical uncertainty of the estimated mass: the bootstrap method, propagation of variance through moments, and statistical analysis of cycle data method. Each of the three methods was implemented on a set of four different NMC measurements, held at the JRC-laboratory in Ispra, Italy, sampling four different Pu samples in a standard Plutonium Scrap Multiplicity Counter (PSMC) well counter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In Situ Measurement of Tritium Permeation Through Stainless Steel

The TMIST-2 irradiation experiment was conducted in the Advanced Test Reactor at Idaho National Laboratory to evaluate tritium permeation through Type 316 stainless steel (316 SS). The interior of a 316 SS seamless tube specimen was exposed to a 4He carrier gas mixed with a specified quantity of tritium (T2) to yield partial pressures of 0.1, 5, and 50 Pa at 292° and 330°C. In-situ tritium permeation measurements were made by passing a He-Ne sweep gas over the outer surface of the specimen to carry the permeated tritium to a bubbler column for liquid scintillation counting. An irradiation enhancement factor (IEF) was determined by comparing in-situ permeation data with a correlation for ex-reactor hydrogen permeation through austenitic stainless steel developed from literature data and reported by Le Claire. Nominal values for the IEF ranged between 3 and 5 for 316 SS. In-situ permeation data were also used to derive an in-reactor permeation correlation as a function of temperature and pressure. In addition, the triton recoil contribution to tritium permeation, which results from the transmutation of 3He to T, was also evaluated by introducing a 4He carrier gas mixed with 3He at a partial pressure of 1013 Pa at 330°C. Less than 3% of the tritium resulting from 3He transmutation contributed to tritium permeation.

In-Reactor↗

Methods for diagnosing and quantifying double pulsing in a Uranium Neutron Collar system using shift register logic

Double pulsing in neutron coincidence counters is the result of a pulse processing chain-3He proportional counter timing incompatibility known to nondestructive assay system designers. It is not currently widely acknowledged, or accounted for, in the user community. However, it is gaining attention as list mode data acquisition and analysis becomes more commonly used for system diagnostics, revealing features that have been overlooked by historic timing gate selection using traditional shift register data acquisition methods. Double pulsing increases the apparent number of measured neutron events from a source. Therefore, it may contribute to a falsely increased count rate if present at the operational high voltage used when assaying samples, even with set predelays. The authors have previously studied the effects of double pulsing, using list mode data acquisition and analysis on neutron pulse trains in three common neutron coincidence counting systems used in routine measurements for international safeguards: a Canberra Industries JCC-71 Neutron Coincidence Collar, a variant on the Canberra Industries JCC-51 Active Well Neutron Coincidence Counter (the Large Volume Active Well Neutron Coincidence Counter), and an AnTech Inc. N2071 Neutron Coincidence Collar. We find that this non-ideal behavior was isolated to the Amptek A111 Charge Sensitive Preamplifier & Discriminator chip used in both the Canberra Industries and Antech systems. The double pulsing fraction was calculated in post-analysis for various high voltage settings in these A111-based systems, assuming no predelay settings. In this work, the authors expand upon this identification and analysis to make it more translatable between list mode data acquisition and analysis and shift register-based analysis. By investigating the double pulsing fractions in a JCC-71 Uranium Neutron Collar as a function of predelay settings, as well as describing and performing alternative tests and analyses to diagnose and quantify the double pulsing using shift register logic, this work hopes to complete the picture of double pulsing identification and analysis.

Safeguards↗

Multiple Changepoint Detection for Non‐Gaussian Time Series

ABSTRACT This article combines methods from existing techniques to identify multiple changepoints in non‐Gaussian autocorrelated time series. A transformation is used to convert a Gaussian series into a non‐Gaussian series, enabling penalized likelihood methods to handle non‐Gaussian scenarios. When the marginal distribution of the data is continuous, the methods essentially reduce to the change of variables formula for probability densities. When the marginal distribution is count‐oriented, Hermite expansions and particle filtering techniques are used to quantify the scenario. Simulations demonstrating the efficacy of the methods are given and two data sets are analyzed: 1) the proportion of home runs hit by Major League Baseball batters from 1920 to 2023 and 2) a six‐dimensional series of tropical cyclone counts from the Earth's basins of generation from 1980 to 2023. In the first series, beta marginal distributions are used to describe the proportions; in the second, Poisson marginal distributions seem appropriate.

Lund, Robert [Department of Statistics University ↗

Data for: Climatic Imprint on Interfacially-Controlled Platinum-Palladium Resources

Data package for manuscript "Climatic Imprint on Interfacially-Controlled Platinum-Palladium Resources" by Emily G. Wright, Ivey Wang, Yihang Fang, Elaine D. Flynn, and Jeffrey G. Catalano. This dataset contains adsorption results from experiments designed to investigate the effect of chloride on Pd(II) adsorption to goethite and Pt(II) adsorption to hematite and goethite, including lab experiments, X-ray absorption fine structure spectroscopy, and models of retention within a laterite. See the associated manuscript for full methods information. The file "Wright2025_PtAds_data.csv" contains the target starting Pt concentration (uM), final aqueous Pt and associated error (in uM), calculated adsorbed Pt and associated error (in umol/m2), target and measured aqueous chloride (mM), target aqueous nitrate (mM), final pH, and mineral concentration/loading (g/L). Associated mineral-free controls (mineral loading = 0 g/L) are included; the aqueous Pd error was not calculated and chloride was not measured in every sample. These data appear in Figures 1, S3, S4, S5, S20, and S22 in the associated manuscript. The file "Wright2025_PdAds_data.csv" contains the target starting Pd concentration (uM), final aqueous Pd and associated error (in uM), calculated adsorbed Pd and associated error (in umol/m2), target and measured aqueous chloride (mM), and mineral concentration/loading (g/L). Associated mineral-free controls (mineral loading = 0 g/L) are included; the aqueous Pd error was not calculated and chloride was not measured in every sample. These data appear in Figures 1, S3, S4, S5, and S20 in the associated manuscript. The file "Wright2025_MineralBatches_data.csv" contains the mineral identity and BET specific surface area (m2/g) for every mineral batch synthesized and used in experiments. The annealing time used is listed for hydrothermally annealed goethite. These data appear in Table S2 in the associated manuscript. The file "Wright2025_XRD_data.csv" contains the XRD patterns for every mineral batch synthesized as the counts as a function of two theta (in degrees). See "Wright2025_MineralBatches_data.csv" for more details on specific mineral batches. These data appear in Figure S2 in the associated manuscript. The file "Wright 2025_ZetaPotential_data.csv" contains the measured zeta potentials for samples of goethite (batch G2) at pH 4 the presence of varying amounts of sodium chloride. These data appear in Table S3 in the associated manuscript. The file "Wright2025_XAFSSamples_data.csv" contains the specific mineral batch, measured final aqueous Pd or Pt (uM), measured final aqueous chloride (mM), and estimated adsorbed Pd or Pt (umol/m2) of all XAFS samples. These data appear in Tables S4, S7, S8, and S10 in the associated manuscript. The files "Wright2025_PdXAFS_data.csv" and "Wright2025_PtXAFS_data.csv" contain the normalized spectra of Pd and Pt, respectively, adsorbed to minerals at varying chloride concentrations. See "Wright2025_XAFSSamples_data.csv" for a guide to sample names. Note that "05" in a sample name is equivalent to "0.5". These data appear in Figures 2, S6, S7, S8, S12, S13, and S14 in the associated manuscript. The file "Wright2025_LateriteProfileProfileModelParameters_data.csv" include the ratio of hematite to hematite and goethite in two synthetic, modeled profiles, as well as the modeled surface areas of goethite and hematite as a function of relative depth within the modeled weathering zone. These data were used, in conjunction with equations presented in the paper, to calculate the theoretical concentrations of Pd and Pt (and the resulting Pt/Pd ratio) within the profiles. These data appear in Figure 3 in the associated manuscript. The file "Wright2025_Imagery_data.zip" is a zipped folder containing the TEM and STEM images appear in Figures S18 and S19. Individual files are labeled as either STEM (Fig. S18) or TEM (Fig. S19) with a letter representing the part of the multipart figure.

58 GEOSCIENCES↗

Application of modern autoradiography to nuclear forensic analysis

Modern autoradiography techniques based on phosphorimaging technology using image plates (IPs) and digital scanning can identify heterogeneities in activity distributions and reveal material properties, serving to inform subsequent analyses. Here, we have adopted these advantages for applications in nuclear forensics, the technical analysis of radioactive or nuclear materials found outside of legal control to provide data related to provenance, production history, and trafficking route for the materials. IP autoradiography is a relatively simple, non-destructive method for sample characterization that records an image reflecting the relative intensity of alpha and beta emissions from a two-dimensional surface. Such data are complementary to information gathered from radiochemical characterization via bulk counting techniques, and can guide the application of other spatially resolved techniques such as scanning electron microscopy (SEM) and secondary ion mass spectrometry (SIMS). IP autoradiography can image large 2-dimenstional areas (up to 20 × 40 cm), with relatively low detection limits for actinides and other radioactive nuclides, and sensitivity to a wide dynamic range (10 5 ) of activity density in a single image. Distributions of radioactivity in nuclear materials can be generated with a spatial resolution of approximately 50 μm using IP autoradiography and digital scanning. While the finest grain silver halide films still provide the best possible resolution (down to ~10 μm), IP autoradiography has distinct practical advantages such as shorter exposure times, no chemical post-processing, reusability, rapid plate scanning, and automated image digitization. Sample preparation requirements are minimal, and the analytical method does not consume or alter the sample. These advantages make IP autoradiography ideal for routine screening of nuclear materials, and for the identification of areas of interest for subsequent micro-characterization methods. Here in this article we present a summary of our setup, as modified for nuclear forensic sample analysis and related research, and provide examples of data from select samples from the nuclear fuel cycle and historical nuclear test debris.

07 ISOTOPE AND RADIATION SOURCES↗

Statistical analysis of the performance and long-term stability of unquenched LSC standards ( 3 H, 14 C) used for radiochemical measurements

Multiple sets of toluene-based unquenched standards, procured over the last 3 decades, were analyzed to determine their stability over time. A statistical analysis was performed to provide insight into the variability for tSIE and counting efficiency measurements of 3 H and 14 C isotopes. Our data suggests that standards remain viable even 30 years after the manufacturer’s recommended expiration date. Overall, these standards have shown no statistically significant sign of performance degradation. We have proven through statistical analysis that these standards can provide comparable performance over time well past their manufactured expiration date.

LSC standards↗

Developing Poultry Facility Type Information from USDA Agricultural Census Data for Use in Epidemiological and Economic Models

The epidemiological and economic modeling of poultry diseases requires knowing the size, location, and operational type of each poultry type operation within the US. At the present time, the only national database of poultry operations that is available to the general public is the USDA's 2002 Agricultural Census data, published by the National Agricultural Statistics Service, herein referred to as the 'NASS data'. The NASS data provides census data at the county level on poultry operations for various operation types (i.e., layers, broilers, turkeys, ducks, geese). However, the number of farms and sizes of farms for the various types are not independent since some facilities have more than one type of operation. Furthermore, some data on the number of birds represents the number sold, which does not represent the number of birds present at any given time. In addition, any data tabulated by NASS that could identify numbers of birds or other data reported by an individual respondent is suppressed by NASS and coded with a 'D'. To be useful for epidemiological and economic modeling, the NASS data must be converted into a unique set of facility types (farms having similar operational characteristics). The unique set must not double count facilities or birds. At the same time, it must account for all the birds, including those for which the data has been suppressed. Therefore, several data processing steps are required to work back from the published NASS data to obtain a consistent database for individual poultry operations. This technical report documents data processing steps that were used to convert the NASS data into a national poultry facility database with twenty-six facility types (7 egg-laying, 6 broiler, 1 backyard, 3 turkey, and 9 others, representing ducks, geese, ostriches, emus, pigeons, pheasants, quail, game fowl breeders and 'other'). The process involves two major steps. The first step defines the rules used to estimate the data that is suppressed within the NASS database. The first step is similar to the first step used to estimate suppressed data for livestock [Melius et al (2006)]. The second step converts the NASS poultry types into the operational facility types used by the epidemiological and economic model. We also define two additional facility types for high and low risk poultry backyards, and an additional two facility types for live bird markets and swap meets. The distribution of these additional facility types among counties is based on US population census data. The algorithm defining the number of premises and the corresponding distribution among counties and the resulting premises density plots for the continental US are provided.

60 APPLIED LIFE SCIENCES↗

The Use of a Multichannel Analyzer to Investigate Effects of Experimental Factors on Gross-Counting Gamma and Neutron Detectors

Radiation detection technology is invaluable to many fields of study in identifying nuclear materials. However, many detectors use gross-counting methods that give only a relative count rate. Without a spectrum (information on counts over time vs energy), it can be more difficult to discern if an alarm is false, innocent, or real. In particular, we would like to understand better the effect of experimental factors (i.e., external conditions and equipment parameters) on detector data, with possible implications for false alarms. To more thoroughly characterize detector technology, a multichannel analyzer (MCA) was used to record spectra from neutron (helium-3 tubes) and gamma (photomultiplier tubes) gross-counting detectors. Several factors could affect the signal-to-noise ratio of sources. For example, we examined the effects of neutron detector high voltage setting on the appearance of a californium-252 spectrum, the effect of discriminator values on integrated counts in neutron detection, and the effect of gain changes on the gamma spectra from several sources. Possible implications of ambient temperature of the experiment on the data collected will be discussed. The input impedance of the MCA must be considered to ensure that data are not affected by the measurement itself. Moreover, a calibration on the MCA was performed to verify the conversion of a MCA channel number to a voltage. In summary, the series of source spectra collected on an MCA with a variety of experimental conditions allow us to understand factors that affect data better, and assure us that gross-counting neutron and gamma detectors will have minimal false alarms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty as a Function of Time for Subcritical Experiment Parameters Using the Hage-Cifarelli Formalism

When designing critical or subcritical experiments, it is desirable to have an estimate of the measurement uncertainties prior to performing an experiment. In addition, an important goal is to have the smallest measurement uncertainties possible given measurement time constraints. Having well-designed experiments with small uncertainties helps improve nuclear data and therefore has direct impacts on criticality safety. This work shows how the uncertainties in various measurement parameters vary as a function of counting time and provides an approach to estimate measured uncertainties and guides in optimizing the available counting time. The uncertainty in six parameters used in subcritical experiments was investigated as a function of time: singles count rate (R{sub 1}), doubles count rate (R{sub 2}), lifetime (1/λ), leakage multiplication (M{sub L}), spontaneous fission rate (FS), and detector efficiency (ε). A comparison to measured data will be presented at the meeting. The approach and results in this work will be used to optimize measurement time in future subcritical experiments and will be used to help estimate measurement uncertainties during the design phase. Having well-designed experiments with the smallest uncertainties possible can help the criticality safety community through data validation. (authors)

42 ENGINEERING↗

High-Multiplicity Muon Airshower Analysis at NOvA Far Detector

We process and analyze muon airshower data from the NOvA far detector using various image processing algorithms, such as Fast Fourier Transformation, and Hough line transformation. From the processed event images, we calculate multiple parameters for our study. We are looking for physics features, including East-West Asymmetry, anisotropies in right ascension, and seasonal variation. Additionally, we have developed an algorithm to count the multiplicity of muons in the airshower events using the single muon data.

Lima, Aklima Khanam [Syracuse U.]↗

Improvements to the 115g/115m Cd Nuclear Data

Repeated measurements of the isotope 115m Cd by Los Alamos National Laboratory (LANL), Pacific Northwest National Laboratory (PNNL), and Atomic Weapons Establishment (AWE) have revealed a consistent discrepancy between beta and gamma counting. This suggests that a significant disparity exists between the true value of the isotope’s gamma-ray branching ratios and the values reported by the National Nuclear Data Center (NNDC). Enriched 114 Cd was irradiated using thermal neutrons to produce a high-purity 115m/g Cd source for counting and analysis using traditional singles gamma-ray spectroscopy, liquid scintillation counting, gas-proportional counting, and analysis using the new Gamma-Alpha-Beta-Gamma (GABγ) and Gamma-Alpha-Beta Radio-Isotope EvaLuator (GABRIEL) coincidence detection systems. Using the D-T fusion generated neutrons, reduces the wait time required to let the short-lived 115Cd ground state decay away by leveraging the 1:1 production ratio of the ground and metastable state of 115 Cd from the 115 In (n,p) reaction relative to the 10:1 production ratio of the ground and metastable isotopes of 115 Cd by thermal neutron capture on 114 Cd. However, the much higher flux in from the Washington State University TRIGA reactor is a more rapid method of production of 115m/gCd but requires access to enriched 114 Cd. High purity 115m/g Cd samples were analyzed on regular intervals over a period of 140-days. The activity of 115m Cd measured by beta and gamma show a clear discrepancy using the current best known gamma-ray decay branching ratios. Based on these observations and measurements, a set of new branching ratio recommendations have been produced using conventional counting techniques and the advanced GAB? and GABRIEL instruments.

07 ISOTOPE AND RADIATION SOURCES↗