Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Solar heating and cooling demonstration project at the Florida solar energy center

The retrofitted solar heating and cooling system installed at the Florida Solar Energy Center is described. The system was designed to supply approximately 70 percent of the annual cooling and 100 percent of the heating load. The project provides unique high temperature, nonimaging, nontracking, evacuated tube collectors. The design of the system was kept simple and employs five hydronic loops. They are energy collection, chilled water production, space cooling, space heating and energy rejection. Information is provided on the system's acceptance test results operation, controls, hardware and installation, including detailed drawings.

Source record↗

Effects of regenerator geometry on pulse tube refrigerator performance

This paper gives results of the cooling performance of a double-inlet pulse tube refrigerator using various regenerators. The same pulse tube was used for all the experiments and measured 4.76 mm in diameter and 46.2 mm in length. A commercial linear compressor with a swept volume of 4 cm3 was used in these experiments. The operating conditions were held constant at a mean pressure of 2.0 MPa and a frequency of 54 Hz. Using finite difference software called REGEN3.1, developed at NIST, and recent experiment results, we optimized a series of regenerators based on dimensions, materials and screen packing. The values used for calculating the thermal conduction through stacked screens by REGEN3.1 were based on recent experimental results from NIST. The regenerator tubes were designed using 316 stainless steel and titanium materials. The regenerator matrices investigated were 400-mesh and 500-mesh stainless steel screen. The valve settings for both orifices were adjusted to minimize the no-load temperature for all regenerators. A cooling capacity curve from 0 to 3 W was also determined. The performance of the pulse tube refrigerator using the different regenerators is discussed. The experimental results from the various regenerators are evaluated and compared with their corresponding numerically calculated coefficient of performance (COP) and regenerator design as determined by REGEN3.1.

NASA Discipline Life Sciences Technologies↗

Comparison of Thermal Management Approaches for Integrated Traction Drives in Electric Vehicles

The continuous push to increase power densities of electric vehicle (EV) traction drive systems necessitates combining electric motor and power electronics into one unit. A single, compact traction drive unit with fewer interconnecting components also facilitates fast, automated assembly of electric vehicles, driving production costs down and enabling wider adoption of EVs. There are a number of challenges associated with the integration of power electronics with the electric machine, including thermal management of the combined traction drive system. However, one important benefit of integration from the thermal management system perspective is the potential for using a single fluid loop instead of two separate cooling systems for the electric machine and the power electronics/inverter. This paper reviews several integration approaches and, employing finite element analysis (FEA), compares thermal management solutions for the combined electric machine and power electronics systems. Namely, three different scenarios are modeled: (1) independent component (motor and power electronics) cooling, which is compared to the combined cooling system approach for (2) radially and (3) axially integrated power electronics modules into the motor enclosure. Temperature distributions for selected thermal loads and thermal resistances from the key heat-generating components to the cooling fluid are compared for each scenario.

47 OTHER INSTRUMENTATION↗

PERFORMANCE, EFFICIENCY AND EMISSIONS EVALUATION OF GASOLINE PORT-FUEL INJECTION, NATURAL GAS DIRECT INJECTION AND BLENDED OPERATION

The need to further reduce fuel consumption and decrease the output of emissions — in order to be within future emissions legislation — is still an ongoing effort for the development of internal combustion engines. Natural gas is a fossil fuel which is comprised mostly of methane and makes it very attractive for use in internal combustion engines because of its higher knock resistance and higher molar hydrogen-to-carbon ratio compared to gasoline. The current paper compares the combustion and emissions behavior of the test engine being operated on either a representative U.S. market gasoline or natural gas. Moreover, specific in-cylinder blend ratios with gasoline and natural gas were also investigated at part-load and wide open throttle conditions. The dilution tolerance for part-load operation was investigated by adding cooled exhaust gas recirculation. The engine used for these investigations was a single cylinder research engine for light duty application which is equipped with two separate fuel systems. Gasoline was injected into the intake port; natural gas was injected directly into the cylinder to overcome the power density loss usually connected with port fuel injection of natural gas. Injecting natural gas directly into the cylinder reduced both ignition delay and combustion duration of the combustion process compared to the injection of gasoline into the intake port. Injecting natural gas and gasoline simultaneously resulted in a higher dilution tolerance compared to operation on one of the fuels alone. Significantly higher net indicated mean effective pressure and indicated thermal efficiency were achieved when natural gas was directly injected after intake valve closing at wide open throttle, compared to an injection while the intake valves were still open. In general it was shown that the blend ratio and the start of injection need to be varied depending on load and dilution level in order to operate the engine with the highest efficiency or highest load.

Advanced Combustion↗

NREL's Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants (Fact Sheet)

This fact sheet describes how the DEVAP air conditioner was invented, explains how the technology works, and why it won an R&D 100 Award. Desiccant-enhanced evaporative (DEVAP) air-conditioning will provide superior comfort for commercial buildings in any climate at a small fraction of the electricity costs of conventional air-conditioning equipment, releasing far less carbon dioxide and cutting costly peak electrical demand by an estimated 80%. Air conditioning currently consumes about 15% of the electricity generated in the United States and is a major contributor to peak electrical demand on hot summer days, which can lead to escalating power costs, brownouts, and rolling blackouts. DEVAP employs an innovative combination of air-cooling technologies to reduce energy use by up to 81%. DEVAP also shifts most of the energy needs to thermal energy sources, reducing annual electricity use by up to 90%. In doing so, DEVAP is estimated to cut peak electrical demand by nearly 80% in all climates. Widespread use of this cooling cycle would dramatically cut peak electrical loads throughout the country, saving billions of dollars in investments and operating costs for our nation's electrical utilities. Water is already used as a refrigerant in evaporative coolers, a common and widely used energy-saving technology for arid regions. The technology cools incoming hot, dry air by evaporating water into it. The energy absorbed by the water as it evaporates, known as the latent heat of vaporization, cools the air while humidifying it. However, evaporative coolers only function when the air is dry, and they deliver humid air that can lower the comfort level for building occupants. And even many dry climates like Phoenix, Arizona, have a humid season when evaporative cooling won't work well. DEVAP extends the applicability of evaporative cooling by first using a liquid desiccant-a water-absorbing material-to dry the air. The dry air is then passed to an indirect evaporative cooling stage, in which the incoming air is in thermal contact with a moistened surface that evaporates the water into a separate air stream. As the evaporation cools the moistened surface, it draws heat from the incoming air without adding humidity to it. A number of cooling cycles have been developed that employ indirect evaporative cooling, but DEVAP achieves a superior efficiency relative to its technological siblings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of a high repetition rate capillary discharge waveguide

A hydrogen-filled capillary discharge waveguide operating at kHz repetition rates is presented for parameters relevant to laser plasma acceleration (LPA). The discharge current pulse was optimized for erosion mitigation with laser guiding experiments and MHD simulation. Heat flow simulations and measurements showed modest temperature rise at the capillary wall due to the average heat load at kHz repetition rates with water-cooled capillaries, which is promising for applications of LPAs such as high average power radiation sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of Urban Aerial Taxi with Cryogenic Components under Design Environment for Novel Vertical Lift Vehicles (DELIVER)

Assessing the potential to bring 100 years of aeronautics knowledge to the entrepreneurs desktop to enable a design environment for emerging vertical lift vehicles is one goal for the NASAs Design Environment for Novel Vertical Lift Vehicles (DELIVER). As part of this effort, a system study was performed using a notional, urban aerial taxi system to better understand vehicle requirements along with the tools and methods capability to assess these vehicles and their subsystems using cryogenic cooled components. The baseline was a vertical take-off and landing (VTOL) aircraft, with all-electric propulsion system assuming 15 year technology performance levels and its capability limited to a pilot with one or two people and cargo. Hydrocarbon-fueled hybrid concepts were developed to improve mission capabilities. The hybrid systems resulted in significant improvements in maximum range and number of on demand mobility (ODM) missions that could be completed before refuel or recharge. An important consideration was thermal management, including the choice for air-cooled or cryogenic cooling using liquid natural gas (LNG) fuel. Cryogenic cooling for critical components can have important implications on component performance and size. Thermal loads were also estimated, subsequent effort will be required to verify feasibility for cooling airflow and packaging. LNG cryogenic cooling of selected components further improved vehicle range and reduced thermal loads, but the same concerns for airflow and packaging still need to be addressed. The use of the NASA Design and Analysis of Rotorcraft (NDARC) tool for vehicle sizing and mission analysis appears to be capable of supporting analyses for present and future types of vehicles, missions, propulsion, and energy sources. Further efforts are required to develop verified models for these new types of propulsion and energy sources in the size and use envisioned for these emerging vehicle and mission classes.

systems analysis↗

Assessment of Urban Aerial Taxi with Cryogenic Components Under Design Environment for Novel Vertical Lift Vehicles (DELIVER)

Assessing the potential to bring 100 years of aeronautics knowledge to the entrepreneurs desktop to enable a design environment for emerging vertical lift vehicles is one goal for the NASA's Design Environment for Novel Vertical Lift Vehicles (DELIVER). As part of this effort, a system study was performed using a notional, urban aerial taxi system to better understand vehicle requirements along with the tools and methods capability to assess these vehicles and their subsystems using cryogenic cooled components. The baseline was a vertical take-off and landing (VTOL) aircraft, with all-electric propulsion system assuming 15 year technology performance levels and its capability limited to a pilot with one or two people and cargo. Hydrocarbon-fueled hybrid concepts were developed to improve mission capabilities. The hybrid systems resulted in significant improvements in maximum range and number of on demand mobility (ODM) missions that could be completed before refuel or recharge. An important consideration was thermal management, including the choice for air-cooled or cryogenic cooling using liquid natural gas (LNG) fuel. Cryogenic cooling for critical components can have important implications on component performance and size. Thermal loads were also estimated, subsequent effort will be required to verify feasibility for cooling airflow and packaging. LNG cryogenic cooling of selected components further improved vehicle range and reduced thermal loads, but the same concerns for airflow and packaging still need to be addressed. The use of the NASA Design and Analysis of Rotorcraft (NDARC) tool for vehicle sizing and mission analysis appears to be capable of supporting analyses for present and future types of vehicles, missions, propulsion, and energy sources. Further efforts are required to develop verified models for these new types of propulsion and energy sources in the size and use envisioned for these emerging vehicle and mission classes.

thermal analysis↗

Physics design of a 100 keV acceleration grid system for the diagnostic neutral beam for international tokamak experimental reactor

This paper describes the physics design of a 100 keV, 60 A H{sup -} accelerator for the diagnostic neutral beam (DNB) for international tokamak experimental reactor (ITER). The accelerator is a three grid system comprising of 1280 apertures, grouped in 16 groups with 80 apertures per beam group. Several computer codes have been used to optimize the design which follows the same philosophy as the ITER Design Description Document (DDD) 5.3 and the 1 MeV heating and current drive beam line [R. Hemsworth, H. Decamps, J. Graceffa, B. Schunke, M. Tanaka, M. Dremel, A. Tanga, H. P. L. De Esch, F. Geli, J. Milnes, T. Inoue, D. Marcuzzi, P. Sonato, and P. Zaccaria, Nucl. Fusion 49, 045006 (2009)]. The aperture shapes, intergrid distances, and the extractor voltage have been optimized to minimize the beamlet divergence. To suppress the acceleration of coextracted electrons, permanent magnets have been incorporated in the extraction grid, downstream of the cooling water channels. The electron power loads on the extractor and the grounded grids have been calculated assuming 1 coextracted electron per ion. The beamlet divergence is calculated to be 4 mrad. At present the design for the filter field of the RF based ion sources for ITER is not fixed, therefore a few configurations of the same have been considered. Their effect on the transmission of the electrons and beams through the accelerator has been studied. The OPERA-3D code has been used to estimate the aperture offset steering constant of the grounded grid and the extraction grid, the space charge interaction between the beamlets and the kerb design required to compensate for this interaction. All beamlets in the DNB must be focused to a single point in the duct, 20.665 m from the grounded grid, and the required geometrical aimings and aperture offsets have been calculated.

43 PARTICLE ACCELERATORS↗

Transpiring Cooling of a Scram-Jet Engine Combustion Chamber

The peak cold-wall heating rate generated in a combustion chamber of a scram-jet engine can exceed 2000 Btu/sq ft sec (approx. 2344 W/sq cm). Therefore, a very effective heat dissipation mechanism is required to sustain such a high heating load. This research focused on the transpiration cooling mechanism that appears to be a promising approach to remove a large amount of heat from the engine wall. The transpiration cooling mechanism has two aspects. First, initial computations suggest that there is a reduction, as much as 75%, in the heat flux incident on the combustion chamber wall due to the transpirant modifying the combustor boundary layer. Secondly, the heat reaching the combustor wall is removed from the structure in a very effective manner by the transpirant. It is the second of these two mechanisms that is investigated experimentally in the subject paper. A transpiration cooling experiment using a radiant heating method, that provided a heat flux as high as 200 Btu/sq ft sec ( approx. 234 W/sq cm) on the surface of a specimen, was performed. The experiment utilized an arc-lamp facility (60-kW radiant power output) to provide a uniform heat flux to a test specimen. For safety reasons, helium gas was used as the transpirant in the experiments. The specimens were 1.9-cm diameter sintered, powdered-stainless-steel tubes of various porosities and a 2.54cm square tube with perforated multi-layered walls. A 15-cm portion of each specimen was heated. The cooling effectivenes and efficiencies by transpiration for each specimen were obtained using the experimental results. During the testing, various test specimens displayed a choking phenomenon in which the transpirant flow was limited as the heat flux was increased. The paper includes a preliminary analysis of the transpiration cooling mechanism and a scaling conversion study that translates the results from helium tests into the case when a hydrogen medium is used.

Choi, Sang H.↗

Implications of Power Plant Idling and Cycling on Water Use Intensity

Survey data from the Energy Information Administration (EIA) was combined with data from the Environmental Protection Agency (EPA) to explore ways in which operations might impact water use intensity (both withdrawals and consumption) at thermoelectric power plants. Two disparities in cooling and power systems operations were identified here that could impact water use intensity: 1) Idling Gap—where cooling systems continue to operate when their boilers and generators are completely idled; and 2) Cycling Gap—where cooling systems operate at full capacity, while their associated boiler and generator systems cycle over a range of loads. Analysis of the EIA and EPA data indicated that cooling systems operated on average 13% more than their corresponding power system (Idling Gap), while power systems operated on average 30% below full load when the boiler was reported as operating (Cycling Gap). Regression analysis was then performed to explore whether the degree of power plant idling/cycling could be related to the physical characteristics of the plant, its environment or time of year. While results suggested that individual power plants’ operations were unique, weak trends consistently pointed to a plant’s place on the dispatch curve as influencing patterns of cooling system, boiler, and generator operation. This insight better positions us to interpret reported power plant water use data as well as improve future water use projections.

54 ENVIRONMENTAL SCIENCES↗

High-Efficiency Solid State Heat Pump Module

The baseline heat pumping technology today is dominated by vapor compression refrigeration cycle that involves use of global warming potential fluids (e.g. hydrofluorocarbons HFC). Current regulations (e.g. 2016 Kigali agreement) and market needs are driving HVAC&R related building, automotive and aerospace industries to safe, compact and cost-effective systems with low global warming potential (GWP) footprint (i.e. direct GWP impact) and higher efficiencies (i.e. indirect GWP impact) and low life cycle cost. Among the solid-state technology options, electrocaloric heat pumping (ECHP) technology has potential to be more efficient, quiet and compact than vapor compression systems. However, electrocaloric technology is still at low maturity, as expressed by standard technology readiness level (TRL) assessments and hence was the focus of the current effort. During the current research effort, UTRC proved feasibility (TRL2/3) of the direct-air ECHP concept by demonstrating cooling of ambient air by 8.4°C (under no load conditions) in a laboratory environment. To the team’s knowledge this is the largest direct air cooling demonstration using electrocaloric technology. The technology was matured from lab-scale dime-sized materials to module-scale dimensions and further demonstrated the feasibility of integrating these electrocaloric materials into modules for providing direct-air cooling. The use of inexpensive polymer-based materials validates the economic feasibility of the proposed technology. Future effort is required to further mature this promising technology to TRL 4/5 demonstrating module and system performance at full capacity and efficiency. Maturity to beyond TRL4/5 could be done with limited potential field trials. Successful field trials can pave the way for commercialization. At full commercialization, electrocaloric based heating and cooling technologies have the potential to enable annual energy savings upwards of a quadrillion BTUs and reduction of 10s of million metric tons/yr of Green-House Gas (GHG) emissions in the US, leapfrogging emerging technologies and disrupting traditional cooling and heating systems in residential and commercial HVAC applications and enabling new applications. This would result in reduction of energy imports, greenhouse gas (GHG) emissions and help create US jobs in this new technical area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A fuselage/tank structure study for actively cooled hypersonic cruise vehicles: Active cooling system analysis

The effects of fuselage cross section and structural arrangement on the performance of actively cooled hypersonic cruise vehicles are investigated. An active cooling system which maintains the aircraft's entire surface area at temperatures below 394 K at Mach 6 is developed along with a hydrogen fuel tankage thermal protection system. Thermodynamic characteristics of the actively cooled thermal protection systems established are summarized. Design heat loads and coolant flowrate requirements are defined for each major structural section and for the total system. Cooling system weights are summarized at the major component level. Conclusions and recommendations are included.

Stone, J. E.↗

Variants of Regenerated Fissile Materials Usage in Thermal Reactors as the First Stage of Fuel Cycle Closing

At present, 240 000 t of spent nuclear fuel (SF) has been accumulated in the world. Its long-term storage should meet safety conditions and requires noticeable finances, which grow every year. Obviously, this situation cannot exist for a long time; in the end, it will require a final decision. At present, several variants of solution of the problem of SF management are considered. Since most of the operating reactors and those under construction are thermal reactors, it is reasonable to assume that the structure of the nuclear power industry in the near and medium-term future will be unchanged, and it will be necessary to utilize plutonium in thermal reactors. In this study, different strategies of SF management are compared: open fuel cycle with long-term SF storage, closed fuel cycle with MOX fuel usage in thermal reactors and subsequent long-term storage of SF from MOX fuel, and closed fuel cycle in thermal reactors with heterogeneous fuel arrangement. The concept of heterogeneous fuel arrangement is considered in detail. While in the case of traditional fuel it is necessary to reprocess the whole amount of spent fuel, in the case of heterogeneous arrangement, it is possible to separate plutonium and {sup 238}U in different fuel rods. In this case, it is possible to achieve nearly complete burning of fissile isotopes of plutonium in fuel rods loaded with plutonium. These fuel rods with burned plutonium can be buried after cooling without reprocessing. They would contain just several percent of initially loaded plutonium, mainly even isotopes. Fuel rods with {sup 238}U alone should be reprocessed in the usual way.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Propane Liquefaction with an Active Magnetic Regenerative Liquefier

Magnetic refrigeration is a cooling technique that uses the magnetocaloric e?ect (MCE). The active magnetic regenerator (AMR) cycle is a regenerative cycle that employs the MCE and consists of four steps: adiabatic magnetization with no heat transfer gas flow; heat transfer gas flow at constant high field; demagnetization with no heat transfer gas flow; and heat transfer gas flow at constant low field. The first heat transfer gas cold-to-hot flow step rejects heat from the magnetized regenerator to a hot sink and the second reverse heat transfer gas hot-to-cold flow step add heat from a cold source into the demagnetized regenerator. Our primary research and development objective is to use the MCE for more efficient liquefaction of much colder cryogens, to help identify problems of effective coupling of cold heat transfer gas of a single-stage reciprocating magnetic refrigerator to a process gas, we have used a single-stage active magnetic regenerative refrigerator (AMRR) with Gd refrigerant to liquefy pure propane gas at two different supply pressures. The high-purity propane was supplied from a small regulated lecture bottle at 295 K via a 1.6 mm o.d. stainless-steel tube into the helium-cooled coiled-fin tube heat exchanger at 49 psia or 27 psia, to liquefy propane at 262 K or 246 K, respectively. Propane liquefied until the small collection vessel and the coiled fin tube heat exchanger were filled at which the flow from the open lecture bottle stopped. The measured rate of liquefaction and the elapsed time for each case were measured and used to determine the volume of propane collected and the cooling power of the AMRR at the liquefaction temperatures. These cooling power results were compared to the cooling power results obtained from the curve of cool-down temperature vs. time data and agreement was excellent after the duty cycle of each cooling process was properly treated.

propane, liquefaction, active magnetic regenerator↗

Shielding Analysis Capability of UNF-ST&DARDS

The Used Nuclear Fuel Storage, Transportation and Disposal Analysis Resource and Data System (UNF-ST&DARDS) is used to perform dose rate calculations for spent nuclear fuel (SNF) transportation packages based on the actual physical and nuclear characteristics (i.e., assembly design, burnup, initial enrichment, and cooling time) of the as-loaded SNF. Nuclear fuel data, transportation package model templates, and SNF canister loading map information residing within the tool facilitate automated generation of SCALE input files for radiation source term and dose rate calculations. Transportation package specific models developed for UNF-ST&DARDS dose rate analyses are described in detail. UNF-ST&DARDS dose rate analyses were performed in this paper for over 400 SNF canisters from 16 sites in their designated transportation casks. For simplicity, representative dose rate calculation results are presented as a function of time (i.e., selected calendar years between 2020 and 2100) for 73 SNF canisters in dry storage at four sites. For these canisters, the projected maximum dose rate values at 2 m from the lateral surfaces of the vehicle under normal conditions of transport (NCT) would vary between 1.9 and 11.5 mrem/h in 2020. Five SNF canisters will exceed the regulatory dose rate limit of 10 mrem/h at 2 m in 2020, and the analyzed SNF canisters will comply with regulatory dose rate limits by 2030. An analysis of the impact on the dose rate of fuel failure and reconfiguration during transportation indicated that the maximum dose rate for hypothetical accident conditions will be unaffected, and the NCT maximum dose rate at 2 m would have a maximum increase by a factor of 1.7 for a representative pressurized water reactor package and by a factor of 2.6 for a representative boiling water reactor package relative to intact fuel. Finally, analysis of the actual heat loading and the dose rate at 2 m from the lateral surface of the vehicle for the five SNF canisters exceeding the NCT regulatory dose rate limit of 10 mrem/h in 2020 showed that the dose rate could be more limiting with respect to regulatory requirements than the heat loading; i.e., the canister transportability date may be evaluated based on the transportation package’s external dose rate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modified Bridgman anvils for high pressure synthesis and neutron scattering

A simple modified Bridgman design for large volume pressure anvils usable in the Paris-Edinburgh (PE) press has been demonstrated at Oak Ridge National Laboratory Spallation Neutron Source. The design shows advantages over the toroidal anvils typically used in the PE press, mainly rapid compression/decompression rates, complete absence of blow-outs upon drastic phase transitions, simplified cooling, high reliability, and relative low loads (~40 tons) corresponding to relatively high pressures (~20 GPa). It also shows advantages over existing large-volume diamond cells as sample volumes of ~2-3 mm 3 can be easily and rapidly synthesized. The anvils thus allow sample sizes sufficient for in situ neutron diffraction as well as rapid synthesis of adequate amounts of new materials for ex situ analysis via total neutron scattering and neutron spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗