Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Transportation Electrification Load Development For A Renewable Future Analysis: Preprint

The transition to electricity as a transportation fuel will create a new load for electricity generation. A set of regional hourly load profiles for electrified vehicles was developed for the 2010 to 2050 timeframe. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determinethe number of plug-in electric vehicles (PEVs) in each analysis region. Market saturation scenarios of 30% and 50% of sales of PEVs consuming on average approx. 6 kWh per day were considered. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging towardutility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across four daily time slices under optimal control from the utility?s perspective. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetrationscenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Moisture Control of Variable-Capacity Heat Pumps in Mechanically Ventilated, Low-Load Homes in Climate Zone 2A

Low-load homes can present a challenge when selecting appropriate space-conditioning equipment. Conventional, fixed-capacity heating and cooling equipment is often oversized for small homes, causing increased first costs and operating costs. This report evaluates the performance of variable-capacity comfort systems, with a focus on inverter-driven, variable-capacity systems, as well as proposed system enhancements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Energy Storage (TES) Modeling and Design (CRADA Final Report)

This project will assess the performance of an innovative high efficiency air conditioner integrated with a composite phase change material (PCM). The research will address critical electric grid challenges by evaluating the thermal efficiency and load-shifting capabilities in NREL’s HVAC characterization lab.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling propellant-based stimulation of a borehole with peridynamics

A non-local formulation of classical continuum mechanics theory known as peridynamics is used to study fracture initiation and growth from a wellbore penetrating the subsurface within the context of propellant-based stimulation. The principal objectives of this work are to analyze the influence of loading conditions on the resulting fracture pattern, to investigate the effect of in-situ stress anisotropy on fracture propagation, and to assess the suitability of peridynamics for modeling complex fracture formation. In peridynamics, the momentum equation from the classical theory of solid mechanics is replaced by a non-local analogue, which results in an integrodifferential conservation equation. A continuum material is discretized with a set of material points that interact with all other points within a specified distance. Interactions between points are governed by bonds that can deform and break depending on loading conditions. The accumulated breakage of bonds gives rise to a picture of complex growth of fractures that is seen as a key advantage in the peridynamic representation of discontinuities. It is shown that the loading rate significantly influences the number and ex- tent of fractures initiated from a borehole. Results show that low loading rates produce fewer but longer fractures, whereas high loading rates produce numerous shorter fractures around the borehole. The numerical method is able to predict fracture growth patterns over a wide range of loading and stress conditions. Our results also show that fracture growth is attenuated with increasing in-situ confining stress, and, in the case of confining stress anisotropy, fracture extensions are largest in the direction perpendicular to the minimum compressive stress. Since the results are in broad qualitative agreement with experimental and numerical studies found in the literature, suggesting that peridynamics can be a powerful tool in the study of complex fracture network formation.

42 ENGINEERING↗

Vertical meteorological patterns and their impact on the energy demand of tall buildings

In accordance with the developing economy and growing population, an increasing number of tall buildings have been constructed over the last 20 years. In 2017, there were 144 new buildings worldwide that were 200 m or greater in height; 50% of these buildings were in China. Due to the vertical gradient impact of meteorological parameters, the energy performance of tall buildings differs from that of general buildings. Few studies exist on vertical meteorological changes using measured data at different heights. Most studies on dynamic energy simulation simulate meteorological parameters using models. This study explores vertical meteorological patterns using hourly dry-bulb temperature, relative humidity, and wind speed data from 2007 to 2017 for a 325 m meteorological tower in Beijing. The temperature decreased significantly with increasing altitude (~0.9 °C per 100 m), while the daily temperature difference decreased with increasing altitude. The absolute humidity did not change significantly with height. The wind speed increased with altitude at approximately 2 m/s per 100 m. The building simulation showed that the annual heating load at a height of 320 m increased by 85% from that at 8 m; the annual cooling load decreased by 20%. Such significant differences in thermal loads for 300-m-tall buildings confirm the need to consider vertical meteorological differences in building performance simulations for tall buildings. A greater number of measurement points at different heights improve the simulation accuracy. Finally, guidance on selecting the heights for vertical metrological measurements is provided based on the influences of building thermal loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data-Driven Load Modeling and Forecasting of Residential Appliances

The expansion of residential demand side management programs and increased deployment of controllable loads require accurate appliance-level load modeling and forecasting. This paper proposes a conditional hidden semi-Markov model to describe the probabilistic nature of residential appliance demand. Model parameters are estimated directly from power consumption data using scalable statistical learning methods. We also propose an algorithm for short-term load forecasting as a key application for appliance-level load models. Case studies performed using granular sub-metered power measurements from various types of appliances demonstrate the effectiveness of the proposed load model for short-term prediction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Test Protocol: Standard Internal Load Generation in Unoccupied Test Homes

This document describes a simple and general way to generate House Simulation Protocol (HSP)-consistent internal sensible and latent loads in unoccupied homes. It is newly updated based on recent experience, and provides instructions on how to calculate and set up the operational profiles in unoccupied homes. The document is split into two sections: how to calculate the internal load magnitudeand schedule, and then what tools and methods should be used to generate those internal loads to achieve research goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Test Protocol: Standard Internal Load Generation for Unoccupied Test Homes

This document describes a simple and general way to generate House Simulation Protocol (HSP)-consistent internal sensible and latent loads in unoccupied homes. It is newly updated based on recent experience, and provides instructions on how to calculate and set up the operational profiles in unoccupied homes. The document is split into two sections: how to calculate the internal load magnitude and schedule, and then what tools and methods should be used to generate those internal loads to achieve research goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits of Leapfrogging to Superefficiency and Low Global Warming Potential Refrigerants in Room Air Conditioning

Hydrofluorocarbons (HFCs) emitted from uses such as refrigerants and thermal insulating foam, are now the fastest growing greenhouse gases (GHGs), with global warming potentials (GWP) thousands of times higher than carbon dioxide (CO2). Because of the short lifetime of these molecules in the atmosphere, mitigating the amount of these short-lived climate pollutants (SLCPs) provides a faster path to climate change mitigation than control of CO2 alone. This has led to proposals from Africa, Europe, India, Island States, and North America to amend the Montreal Protocol on Substances that Deplete the Ozone Layer (Montreal Protocol) to phase-down high-GWP HFCs. Simultaneously, energy efficiency market transformation programs such as standards, labeling and incentive programs are endeavoring to improve the energy efficiency for refrigeration and air conditioning equipment to provide life cycle cost, energy, GHG, and peak load savings. In this paper we provide an estimate of the magnitude of such GHG and peak electric load savings potential, for room air conditioning, if the refrigerant transition and energy efficiency improvement policies are implemented either separately or in parallel. We find that implementing HFC refrigerant transition and energy efficiency improvement policies in parallel for room air conditioning, roughly doubles the benefit of either policy implemented separately. We estimate that shifting the 2030 world stock of room air conditioners from the low efficiency technology using high-GWP refrigerants to higher efficiency technology and low-GWP refrigerants in parallel would save between 340-790 gigawatts (GW) of peak load globally, which is roughly equivalent to avoiding 680-1550 peak power plants of 500MW each. This would save 0.85 GT/year annually in China equivalent to over 8 Three Gorges dams and over 0.32 GT/year annually in India equivalent to roughly twice India’s 100GW solar mission target. While there is some uncertainty associated with emissions and growth projections, moving to efficient room air conditioning (~30% more efficient than current technology) in parallel with low-GWP refrigerants in room air conditioning could avoid up to ~25 billion tonnes of CO2 in 2030, ~33 billion in 2040, and ~40 billion in 2050, i.e. cumulative savings up to 98 billion tonnes of CO2 by 2050. Therefore, superefficient room ACs using low-GWP refrigerants merit serious consideration to maximize peak load reduction and GHG savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prediction of Air Conditioning Load Response for Providing Spinning Reserve - ORNL Report

This report assesses the use of air conditioning load for providing spinning reserve and discusses the barriers and opportunities. Air conditioning load is well suited for this service because it often increases during heavy load periods and can be curtailed for short periods with little impact to the customer. The report also provides an appendix describing the ambient temperature effect on air conditioning load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficient fluid powered linear actuator with variable area

Hydraulic actuation systems having variable displacements and energy recovery capabilities include cylinders with pistons disposed inside of barrels. When operating in energy consuming modes, high speed valves pressurize extension chambers or retraction chambers to provide enough force to meet or counteract an opposite load force. When operating in energy recovery modes, high speed valves return a working fluid from extension chambers or retraction chambers, which are pressurized by a load, to an accumulator for later use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficient fluid powered linear actuator with variable area and concentric chambers

Hydraulic actuation systems having concentric chambers, variable displacements and energy recovery capabilities include cylinders with pistons disposed inside of barrels. When operating in energy consuming modes, high speed valves pressurize extension chambers or retraction chambers to provide enough force to meet or counteract an opposite load force. When operating in energy recovery modes, high speed valves return a working fluid from extension chambers or retraction chambers, which are pressurized by a load, to an accumulator for later use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results of an Analysis of Field Studies of the Intrinsic Dynamic Characteristics Important for the Safety of Nuclear Power Plant Equipment

A classification of the equipment important for the safety of nuclear power plants is proposed in terms of its dynamic behavior under seismic loading. An extended bank of data from dynamic tests over the entire range of thermal and mechanical equipment in generating units with VVER-1000 and RBMK-1000 reactors is analyzed. Results are presented from a study of the statistical behavior of the distribution of vibrational frequencies and damping decrements with the “small perturbation” factor that affects the measured damping decrements taken into account. A need to adjust the regulatory specifications for choosing the values of the damping decrements with specified inertial loads on equipment owing to seismic effects during design calculations is identified. Minimum values of the decrements are determined and proposed for all types of equipment as functions of the directions and natural vibration frequencies of the dynamic interactions to be adopted as conservative standard values in the absence of actual experimental data in the course of design studies of seismic resistance.

42 ENGINEERING↗

A Siamese CNN + KNN-Based Classification Framework for Non-intrusive Load Monitoring

Through the development of smart grids, programs such as demand side response, have been presented as auxiliary services to the real-time operation of distributed networks. In order to provide consumers information on their energy consumption, so that a modulation in consumption is possible, non-intrusive load monitoring has been introduced as an solution to this pattern recognition problem. Non-intrusive load monitoring enables the modeling of electrical loads connected to the low-voltage system, considering only a single measurement point. Presented state-of-the-art solutions though, consider availability of data as well as representation of all possible classes of the environment. This is of course a most conservative hypothesis, since in real-life applications availability of such data is much difficult, as well as the dynamic behavior of models is implicitly evolving in time. Here, a framework that uses neural Siamese networks with k-nearest neighbor clustering is presented toward non-intrusive load monitoring. Online learning feature is implemented, which relaxes the hypothesis of data requirements as well addresses the evolving nature of load profile. k-nearest clustering allows nonlinear characteristic space modelling. Test results using synthetics and real-life data show that the solution, besides obtaining a good generalizability in the classification, also obtained results with an accuracy of 95.77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reducing Idle Power Consumption in Office Spaces Saves U.S. Navy in Energy Costs (Fact Sheet)

As part of a two-year project to demonstrate energy efficiency measures, renewable energy generation, and energy systems integration, the National Renewable Energy Laboratory (NREL) has identified advanced plug load controls as a promising technology for reducing energy use and related costs in the U.S. Navy's Naval Facilities Engineering Command (NAVFAC) office spaces.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy savings and usability of zero-client computing in office settings

This study provides a detailed comparison of the power consumption, usability, and applicability of virtual machines (VMs) - accessed through zero-client devices - and traditional laptop computers in office settings. The study analyzed high-level plug loads across two office spaces, one using traditional laptops, the other using zero clients. In addition, the individual power consumption of four workstations was monitored and compared. Each workstation user switched between using a laptop or zero client for one week and then using the alternate system the second week. Results of the high-level and workstation analysis show that average workstation plug loads are lower for occupants using zero clients. However, this does not include power consumed by the data center managing VMs. This study calculates the affiliated data center power draw of VMs and shows that server-related loads push total zero-client computing energy higher than that of traditional laptops. Finally, a questionnaire was administered to building occupants to determine the appropriateness of zero-client computing for various user groups, with the results indicating that VMs are most appropriate for more basic software functions. The findings of this study suggest that advances in server technology can help improve both the overall efficiency and the usability of zero-client computing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗