Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Impact of intravenous contrast used in computed tomography on radiation dose to carotid arteries and thyroid in intensity-modulated radiation therapy planning for nasopharyngeal carcinoma

The aim of this study was to investigate if intravenous contrast injection affected the radiation doses to carotid arteries and thyroid during intensity-modulated radiation therapy (IMRT) planning for nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC underwent plain computed tomography (CT) followed by repeated scanning after contrast injection. Carotid arteries (common, external, internal), thyroid, target volumes, and other organs-at-risk (OARs), as well as IMRT planning, were based on contrast-enhanced CT (CE-CT) images. All these structures and the IMRT plans were then copied and transferred to the non–contrast-enhanced CT (NCE-CT) images, and dose calculation without optimization was performed again. The radiation doses to the carotid arteries and the thyroid based on CE-CT and NCE-CT were then compared. Based on CE-CT, no statistical differences, despite minute numeric decreases, were noted in all dosimetric parameters (minimum, maximum, mean, median, D05, and D01) of the target volumes, the OARs, the carotid arteries, and the thyroid compared with NCE-CT. Our results suggested that compared with NCE-CT planning, CE-CT scanning should be performed during IMRT for better target and OAR delineation, without discernible change in radiation doses.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bone Health Monitoring in Astronauts: Recommended Use of Quantitative Computed Tomography [QCT] for Clinical and Operational Decisions

This slide presentation reviews the concerns that astronauts in long duration flights might have a greater risk of bone fracture as they age than the general population. A panel of experts was convened to review the information and recommend mechanisms to monitor the health of bones in astronauts. The use of Quantitative Computed Tomography (QCT) scans for risk surveillance to detect the clinical trigger and to inform countermeasure evaluation is reviewed. An added benefit of QCT is that it facilitates an individualized estimation of bone strength by Finite Element Modeling (FEM), that can inform approaches for bone rehabilitation. The use of FEM is reviewed as a process that arrives at a composite number to estimate bone strength, because it integrates multiple factors.

Sibonga, J. D.↗

Comparison of x ray computed tomography number to proton relative linear stopping power conversion functions using a standard phantom

Purpose: Adequate evaluation of the results from multi-institutional trials involving light ion beam treatments requires consideration of the planning margins applied to both targets and organs at risk. A major uncertainty that affects the size of these margins is the conversion of x ray computed tomography numbers (XCTNs) to relative linear stopping powers (RLSPs). Various facilities engaged in multi-institutional clinical trials involving proton beams have been applying significantly different margins in their patient planning. This study was performed to determine the variance in the conversion functions used at proton facilities in the U.S.A. wishing to participate in National Cancer Institute sponsored clinical trials. Methods: A simplified method of determining the conversion function was developed using a standard phantom containing only water and aluminum. The new method was based on the premise that all scanners have their XCTNs for air and water calibrated daily to constant values but that the XCTNs for high density/high atomic number materials are variable with different scanning conditions. The standard phantom was taken to 10 different proton facilities and scanned with the local protocols resulting in 14 derived conversion functions which were compared to the conversion functions used at the local facilities. Results: For tissues within ±300 XCTN of water, all facility functions produced converted RLSP values within ±6% of the values produced by the standard function and within 8% of the values from any other facility's function. For XCTNs corresponding to lung tissue, converted RLSP values differed by as great as ±8% from the standard and up to 16% from the values of other facilities. For XCTNs corresponding to low-density immobilization foam, the maximum to minimum values differed by as much as 40%. Conclusions: The new method greatly simplifies determination of the conversion function, reduces ambiguity, and in the future could promote standardization between facilities. Although it was not possible from these experiments to determine which conversion function is most appropriate, the variation between facilities suggests that the margins used in some facilities to account for the uncertainty in converting XCTNs to RLSPs may be too small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Depressurization-Induced Fines Migration in Sediments Containing Methane Hydrate: X-Ray Computed Tomography Imaging Experiments

Depressurization of hydrate-bearing sediments (HBS) can cause the movement of fine particles, and in turn, such fines migration affects fluid flow and mechanical behavior of sediments, ultimately affecting long-term hydrocarbon production and wellbore stability. In this work, we investigate how and to what extent depressurization of HBS causes fines migration using X-ray computed tomography (CT) imaging. Methane hydrate was synthesized in sediments with 10% fines content (FC), composed of sands with silt and/or clay, and the hydrate-bearing samples were stepwisely depressurized while acquiring CT images. The CT images were analyzed to quantify the spatial changes in FC in the host sediment and thus to capture the fines migration during depressurization. It was found that the FC changes began occurring from the hydrate dissociation regions. This confirms that the multiphase flow caused by depressurization accompanies fines migration. Depressurization of HBS with a hydrate saturation of ~20–40% caused FC reduction from ~10% to ~6–9%, and the extent of fines migration differed with the particle sizes of the host sands and the types of fines. It was found that fines migration was more pronounced with coarse sands and with silty fines. Such observed level of FC reduction is estimated to increase sediment permeability by several factors based on the Kozeny-type permeability model. In conclusion, our results support the notion that the extent of fines migration and its effect on fluid flow behavior need to be assessed in consideration of physical properties of host sediment and fine particles to identify optimum depressurization strategies.

42 ENGINEERING↗

Detection of Type II Endoleak After Endovascular Aortic Repair: Comparison Between Magnetic Resonance Angiography and Blood-Pool Contrast Agent and Dual-Phase Computed Tomography Angiography

PurposeThis prospective study was designed to assess the diagnostic value of magnetic resonance angiography (MRA) with blood-pool contrast agent (gadofosveset) in the detection of type-II endoleak after endovascular aortic repair (EVAR).MethodsThirty-two patients with aortic aneurysms who had undergone EVAR were included in this study. All patients were examined by dual-phase computed tomography angiography (CTA) as well as MRA with gadofosveset in the first-pass and steady-state phases. Two independent readers evaluated the images of CTA and MRA in terms of endoleak type II, feeding vessel, and image quality.ResultsMedian follow-up-time after EVAR was 22 months (range 4 to 59). Endoleak type II was detected by CTA in 12 of 32 patients (37.5%); MRA detected endoleak in all of these patients as well as in another 9 patients (n = 21, 65.6%), of whom the endoleaks in 6 patients showed an increasing diameter. Most endoleaks were detected in the steady-state phase (n = 14). The decrease in diameter of the aneurysmal sac was significantly greater in the patients without a visible endoleak that was visible on MRA (P = 0.004). In the overall estimation of diagnostic accuracy, MRA was judged superior to CTA in 66% of all examinations.ConclusionMRA with gadofosveset appeared superior to CTA, and has higher diagnostic accuracy, in the detection of endoleak after EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Exploratory Study Into the Role of Dynamic Contrast-Enhanced Magnetic Resonance Imaging or Perfusion Computed Tomography for Detection of Intratumoral Hypoxia in Head-and-Neck Cancer

Purpose: Hypoxia in patients with head-and-neck cancer (HNC) is well established and known to cause radiation resistance and treatment failure in the management of HNC. This study examines the role of parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and perfusion computed tomography (CT) as surrogate markers of intratumoral hypoxia, defined by using the exogenous marker of hypoxia pimonidazole and the endogenous marker carbonic anhydrase 9 (CA9). Methods and Materials: Patients with HNC underwent preoperative DCE-MRI, perfusion CT, and pimonidazole infusion. Imaging parameters were correlated with pimonidazole and CA9 staining. The strength of correlations was tested by using a two-tailed Spearman's rank correlation coefficient. Results: Twenty-three regions of interest were analyzed from the 7 patients who completed the DCE-MRI studies. A number of statistically significant correlations were seen between DCE-MRI parameters (volume transfer between blood plasma and extracellular extravascular space [EES], volume of EES, rate constant between EES and blood plasma, time at arrival of contrast inflow, time to peak, average gradient, and time to onset) and areas with a pimonidazole score of 4. In the case of CA9 staining, only a weak correlation was shown with wash-in rate. There were no significant correlations between perfusion CT parameters and pimonidazole staining or CA9 expression. Conclusion: Intratumoral hypoxia in patients with HNC may be predicted by using DCE-MRI; however, perfusion CT requires further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implications of free breathing motion assessed by 4D-computed tomography on the delivered dose in radiotherapy for esophageal cancer

The aim of this study was to assess the effect of breathing motion on the delivered dose in esophageal cancer 3-dimensional (3D)-conformal radiotherapy (3D-CRT), intensity-modulated radiotherapy (IMRT), and volumetric modulated arc therapy (VMAT). We assessed 16 patients with esophageal cancer. All patients underwent 4D-computed tomography (4D-CT) for treatment planning. For each of the analyzed patients, 1 3D-CRT, 1 IMRT, and 1 VMAT (RapidArc—RA) plan were calculated. Each of the 3 initial plans was recalculated on the 4D-CT (for the maximum free inspiration and maximum free expiration) to assess the effect of breathing motion. We assessed the minimum dose (D{sub min}) and mean dose (D{sub mean}) to the esophagus within the planning target volume, the volume changes of the lungs, the D{sub mean} and the total lung volume receiving at least 40 Gy (V{sub 40}), and the V{sub 30}, V{sub 20}, V{sub 10}, and V{sub 5}. For the heart we assessed the D{sub mean} and the V{sub 25}. Over all techniques and all patients the change in D{sub mean} as compared with the planned D{sub mean} (planning CT [PCT]) to the esophagus was 0.48% in maximum free inspiration (CT-insp) and 0.55% in maximum free expiration (CT-exp). The D{sub min} CT-insp change was 0.86% and CT-exp change was 0.89%. The D{sub mean} change of the lungs (heart) was in CT-insp 1.95% (2.89%) and 3.88% (2.38%) in CT-exp. In all, 4 patients had a clinically relevant change of the dose (≥ 5% D{sub mean} to the heart and the lungs) between inspiration and expiration. These patients had a very cranially or caudally situated tumor. There are no relevant differences in the delivered dose to the regions of interest among the 3 techniques. Breathing motion management could be considered to achieve a better sparing of the lungs or heart in patients with cranially or caudally situated tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Micro-Computed Tomography for Structural Analysis of All-Solid-State Battery at Pouch Cell Level

Characterizing the microstructure of all-solid-state batteries (ASSBs) during fabrication and operation is vital for their advancement, particularly as scaling to pouch cell levels introduces challenges in probing large-scale microstructural evolution. This work highlights the potential of synchrotron X-ray micro-computed tomography (sXCT) as a nondestructive, rapid (<30 min), and high-resolution technique for visualizing and quantifying key microstructural features, including overhang, porosity, contact loss, active surface area, and tortuosity, in all-solid-state pouch cells. The large field of view (up to millimeters) of sXCT enables detailed analysis at an industry-relevant scale, bridging the gap between laboratory research and commercial applications. Furthermore, integrating realistic sXCT-derived 3D models into multiphysics simulations could provide insights into chemo-mechanical degradation, particularly at the edges of the pouch cells, offering a pathway for designing robust, high-performance ASSBs. This perspective establishes sXCT as an indispensable tool for advancing both the understanding and the engineering of next-generation energy storage systems.

25 ENERGY STORAGE↗

Cone Beam Computed Tomography Image Guidance System for a Dedicated Intracranial Radiosurgery Treatment Unit

Purpose: Image guidance has improved the precision of fractionated radiation treatment delivery on linear accelerators. Precise radiation delivery is particularly critical when high doses are delivered to complex shapes with steep dose gradients near critical structures, as is the case for intracranial radiosurgery. To reduce potential geometric uncertainties, a cone beam computed tomography (CT) image guidance system was developed in-house to generate high-resolution images of the head at the time of treatment, using a dedicated radiosurgery unit. The performance and initial clinical use of this imaging system are described. Methods and Materials: A kilovoltage cone beam CT system was integrated with a Leksell Gamma Knife Perfexion radiosurgery unit. The X-ray tube and flat-panel detector are mounted on a translational arm, which is parked above the treatment unit when not in use. Upon descent, a rotational axis provides 210 Degree-Sign of rotation for cone beam CT scans. Mechanical integrity of the system was evaluated over a 6-month period. Subsequent clinical commissioning included end-to-end testing of targeting performance and subjective image quality performance in phantoms. The system has been used to image 2 patients, 1 of whom received single-fraction radiosurgery and 1 who received 3 fractions, using a relocatable head frame. Results: Images of phantoms demonstrated soft tissue contrast visibility and submillimeter spatial resolution. A contrast difference of 35 HU was easily detected at a calibration dose of 1.2 cGy (center of head phantom). The shape of the mechanical flex vs scan angle was highly reproducible and exhibited <0.2 mm peak-to-peak variation. With a 0.5-mm voxel pitch, the maximum targeting error was 0.4 mm. Images of 2 patients were analyzed offline and submillimeter agreement was confirmed with conventional frame. Conclusions: A cone beam CT image guidance system was successfully adapted to a radiosurgery unit. The system is capable of producing high-resolution images of bone and soft tissue. The system is in clinical use and provides excellent image guidance without invasive frames.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The microstructure of capsule containing self-healing materials: A micro-computed tomography study

Autonomic self-healing materials are materials with built-in (micro-) capsules or vessels, which upon fracturing release healing agents in order to recover the material's physical and mechanical properties. In order to better understand and engineer these materials, a thorough characterization of the material's microstructural behavior is essential and often overlooked. In this context, micro-computed tomography (μCT) can be used to investigate the three dimensional distribution and (de)bonding of (micro-) capsules in their native state in a polymer system with self-healing properties. Furthermore, in-situ μCT experiments in a self-healing polymer and a self-healing concrete system can elucidate the breakage and leakage behavior of (micro-) capsules at the micrometer scale. While challenges related to image resolution and contrast complicate the characterization in specific cases, non-destructive 3D imaging with μCT is shown to contribute to the understanding of the link between the microstructure and the self-healing behavior of these complex materials. - Highlights: • μCT imaging allows for the analysis of microcapsule distribution patterns in self-healing materials. • μCT allows for qualitative and quantitative measurements of healing agent release from carriers in self-healing materials. • Experimental set-ups can be optimized by changing chemical compounds in the system to ensure maximum quality imaging.

36 MATERIALS SCIENCE↗

Attenuation properties and percentage depth dose of tannin-based Rhizophora spp. particleboard phantoms using computed tomography (CT) and treatment planning system (TPS) at high energy x-ray beams

A set of tannin-based Rhizophora spp. particleboard phantoms with dimension of 30 cm x 30 cm was fabricated at target density of 1.0 g/cm{sup 3}. The mass attenuation coefficient of the phantom was measured using {sup 60}Co gamma source. The phantoms were scanned using Computed Tomography (CT) scanner and the percentage depth dose (PDD) of the phantom was calculated using treatment planning system (TPS) at 6 MV and 10 MV x-ray and compared to that in solid water phantoms. The result showed that the mass attenuation coefficient of tannin-based Rhizohora spp. phantoms was near to the value of water with χ{sup 2} value of 1.2. The measured PDD also showed good agreement with solid water phantom at both 6 MV and 10 MV x-ray with percentage deviation below 8% at depth beyond the maximum dose, Z{sub max}.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of pore structures and cracking in cement paste exposed to elevated temperatures by X-ray computed tomography

When cement-based materials are exposed to the high temperatures induced by fire, which can rapidly cause temperatures of over 1000 °C, the changes in pore structure and density prevail. In the present study, mortar specimens were subjected to a series of increasing temperatures to explore the temperature-dependent evolution of internal pore structure. High-performance X-ray computed tomography (CT) was used to observe the evolution of temperature-induced discontinuities at the sub-millimeter level. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were employed to investigate the cause of physical changes in the heated mortar specimens. Results exhibit the changes in pore structure caused by elevated temperatures, and thermally induced fractures. We discuss the progressive formation of thermally induced fracture networks, which is a prerequisite for spalling failure of cement-based materials by fire, based on visual observations of the 3D internal structures revealed by X-ray CT.

36 MATERIALS SCIENCE↗

Comparison of Intensity-Modulated Radiotherapy Planning Based on Manual and Automatically Generated Contours Using Deformable Image Registration in Four-Dimensional Computed Tomography of Lung Cancer Patients

Purpose: To evaluate the implications of differences between contours drawn manually and contours generated automatically by deformable image registration for four-dimensional (4D) treatment planning. Methods and Materials: In 12 lung cancer patients intensity-modulated radiotherapy (IMRT) planning was performed for both manual contours and automatically generated ('auto') contours in mid and peak expiration of 4D computed tomography scans, with the manual contours in peak inspiration serving as the reference for the displacement vector fields. Manual and auto plans were analyzed with respect to their coverage of the manual contours, which were assumed to represent the anatomically correct volumes. Results: Auto contours were on average larger than manual contours by up to 9%. Objective scores, D{sub 2%} and D{sub 98%} of the planning target volume, homogeneity and conformity indices, and coverage of normal tissue structures (lungs, heart, esophagus, spinal cord) at defined dose levels were not significantly different between plans (p = 0.22-0.94). Differences were statistically insignificant for the generalized equivalent uniform dose of the planning target volume (p = 0.19-0.94) and normal tissue complication probabilities for lung and esophagus (p = 0.13-0.47). Dosimetric differences >2% or >1 Gy were more frequent in patients with auto/manual volume differences {>=}10% (p = 0.04). Conclusions: The applied deformable image registration algorithm produces clinically plausible auto contours in the majority of structures. At this stage clinical supervision of the auto contouring process is required, and manual interventions may become necessary. Before routine use, further investigations are required, particularly to reduce imaging artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-207-07: Dual-Energy Computed Tomography Detection Limit of Various Radiopaque Contrast Agents That Can Be Infused Within Absorbable Inferior Vena Cava Filters

Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GE Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.

60 APPLIED LIFE SCIENCES↗

Validation of High-Risk Computed Tomography Features for Detection of Local Recurrence After Stereotactic Body Radiation Therapy for Early-Stage Non-Small Cell Lung Cancer

Purpose: Fibrotic changes after stereotactic body radiation therapy (SBRT) for stage I non-small cell lung cancer (NSCLC) are difficult to distinguish from local recurrences (LR), hampering proper patient selection for salvage therapy. This study validates previously reported high-risk computed tomography (CT) features (HRFs) for detection of LR in an independent patient cohort. Methods and Materials: From a multicenter database, 13 patients with biopsy-proven LR were matched 1:2 to 26 non-LR control patients based on dose, planning target volume (PTV), follow-up time, and lung lobe. Tested HRFs were enlarging opacity, sequential enlarging opacity, enlarging opacity after 12 months, bulging margin, linear margin disappearance, loss of air bronchogram, and craniocaudal growth. Additionally, 2 new features were analyzed: the occurrence of new unilateral pleural effusion, and growth based on relative volume, assessed by manual delineation. Results: All HRFs were significantly associated with LR except for loss of air bronchogram. The best performing HRFs were bulging margin, linear margin disappearance, and craniocaudal growth. Receiver operating characteristic analysis of the number of HRFs to detect LR had an area under the curve (AUC) of 0.97 (95% confidence interval [CI] 0.9-1.0), which was identical to the performance described in the original report. The best compromise (closest to 100% sensitivity and specificity) was found at ≥4 HRFs, with a sensitivity of 92% and a specificity of 85%. A model consisting of only 2 HRFs, bulging margin and craniocaudal growth, resulted in a sensitivity of 85% and a specificity of 100%, with an AUC of 0.96 (95% CI 0.9-1.0) (HRFs ≥2). Pleural effusion and relative growth did not significantly improve the model. Conclusion: We successfully validated CT-based HRFs for detection of LR after SBRT for early-stage NSCLC. As an alternative to number of HRFs, we propose a simplified model with the combination of the 2 best HRFs: bulging margin and craniocaudal growth, although validation is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Regularizing INR with Diffusion Prior for Self-Supervised 3D Reconstruction OF Neutron Computed Tomography Data

Recently, generative diffusion priors have made huge strides as inverse problem solvers, including the ability to be adapted for inference on out-of-distribution data. Concurrently, implicit neural representations (INRs) have emerged as fast and lightweight inverse imaging solvers that are amenable to hybrid approaches that combine learned priors with traditional inverse problem formulations. In this paper, we present a diffusive computed tomography (CT) inversion framework for regularizing INRs called Diffusive INR (DINR), designed to enable high-quality reconstruction from sparse-view neutron CT. Pretrained purely on synthetic data, DINR is evaluated on simulated and experimentally obtained observations of concrete microstructures, where traditional reconstruction methods suffer substantial degradation when the number of views is reduced. Our approach delivers superior performance, reduces reconstruction artifacts, and achieves gains in PSNR and SSIM, enabling accurate micro-structural characterization even under extreme data limitations compared to state-of-the-art sparse-view reconstruction techniques.

Hossain, Maliha [ORNL]↗

Augmented Reality Rendering of Computed Tomography 3-D Density Data

Overall Objectives: Purchase equipment and Software required to develop the technology; Import CT Data for viewing on an AR device; Develop the tools necessary to manipulate the data in AR. With Augmented and Virtual Reality technology becoming more common and affordable everyday, new visualization techniques need to be developed that can leverage this technology to visualize data in new and useful ways. Computed Tomography (CT) scans, are the result of a powerful X-ray machine taking multiple images of the same object. These images represent slices of the original object and have extremely high resolution. Because of the high resolution, CT scanning is often used in the medical field but is becoming increasingly predominate in diverse industrial fields as well. This is an example of a CT scan that shows an object with multiple items inside. These items are represented by different colors in gray scale to indicate different densities. This is also from the data set used for the duration of the project. The data sets usually contain hundreds of slides that looks like just like this. Visualizing these large data sets can be difficult. The general approach for this seedling was to identify the devices and software that are currently in use for data visualization and evaluate them for use in the project. After that a plan was made to convert the data into a format viewable in AR. Tools were then developed to manipulate that data. The project was a success, but there is plenty of room to advance the technology and create better visualizations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of Risk Survival Measures Estimated From Pre- and Posttreatment Computed Tomography Scans Improves Stratification of Patients With Early-Stage Non-small Cell Lung Cancer Treated With Stereotactic Body Radiation Therapy

To predict overall survival of patients receiving stereotactic body radiation therapy (SBRT) for early-stage non-small cell lung cancer (ES-NSCLC), we developed a radiomic model that integrates risk of death estimates and changes based on pre- and posttreatment computed tomography (CT) scans. We hypothesize this innovation will improve our ability to stratify patients into various oncologic outcomes with greater accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗