Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

SU-F-T-377: Monte Carlo Re-Evaluation of Volumetric-Modulated Arc Plans of Advanced Stage Nasopharygeal Cancers Optimized with Convolution-Superposition Algorithm

Background: Commercial treatment planning system Pinnacle3 (Philips, Fitchburg, WI, USA) employs a convolution-superposition algorithm for volumetric-modulated arc radiotherapy (VMAT) optimization and dose calculation. Study of Monte Carlo (MC) dose recalculation of VMAT plans for advanced-stage nasopharyngeal cancers (NPC) is currently limited. Methods: Twenty-nine VMAT prescribed 70Gy, 60Gy, and 54Gy to the planning target volumes (PTVs) were included. These clinical plans achieved with a CS dose engine on Pinnacle3 v9.0 were recalculated by the Monaco TPS v5.0 (Elekta, Maryland Heights, MO, USA) with a XVMC-based MC dose engine. The MC virtual source model was built using the same measurement beam dataset as for the Pinnacle beam model. All MC recalculation were based on absorbed dose to medium in medium (Dm,m). Differences in dose constraint parameters per our institution protocol (Supplementary Table 1) were analyzed. Results: Only differences in maximum dose to left brachial plexus, left temporal lobe and PTV54Gy were found to be statistically insignificant (p> 0.05). Dosimetric differences of other tumor targets and normal organs are found in supplementary Table 1. Generally, doses outside the PTV in the normal organs are lower with MC than with CS. This is also true in the PTV54-70Gy doses but higher dose in the nasal cavity near the bone interfaces is consistently predicted by MC, possibly due to the increased backscattering of short-range scattered photons and the secondary electrons that is not properly modeled by the CS. The straight shoulders of the PTV dose volume histograms (DVH) initially resulted from the CS optimization are merely preserved after MC recalculation. Conclusion: Significant dosimetric differences in VMAT NPC plans were observed between CS and MC calculations. Adjustments of the planning dose constraints to incorporate the physics differences from conventional CS algorithm should be made when VMAT optimization is carried out directly with MC dose engine.

60 APPLIED LIFE SCIENCES↗

Extremum Seeking-Based Control System for Particle Accelerator Beam Loss Minimization

Particle accelerators throughout the world vary widely in terms of age and availability of advanced noninvasive diagnostics that provide varying levels of detail about the accelerated beams. Additionally, beam loss measurements and current monitors are ubiquitous in the accelerator community, they are noninvasive, and they are some of the most important metrics in terms of preventing damage or irradiation of beam pipes and equipment for high-energy machines. However, beam loss and current measurements are difficult to use for feedback tuning because of a lack of a known analytic relationship between scalar loss measurements throughout an accelerator and the hundreds of thousands of parameters that influence the beam and time variation of the beam source itself. In this work, we present a model-independent extremum seeking (ES) controller, which has been implemented for automated tuning and optimization of the Los Alamos Neutron Science Center (LANSCE) linear ion accelerator based only on scalar quantities, such as beam loss or flux measurements. We demonstrate the approach on various accelerator subsystems, including groups of radio frequency (RF) accelerating cavities, quadrupole magnets, bending magnets, and steering magnets. This tool is now available as a use graphical user interface (GUI) in the LANSCE control room, allowing beam physicists to choose arbitrary groups of parameters and beam loss or current monitors for adaptive tuning.

43 PARTICLE ACCELERATORS↗

Construction and Test of a Novel Superconducting RF Electron gun

The University of Wisconsin-Madison has completed installation of a superconducting electron gun. Its concept was optimized to be the source for a CW free electron laser facility with multiple megahertz repetition rate end stations. This VHF superconducting configuration holds the promise of the highest performance for CW injectors. Initial commissioning efforts show that the cavity can achieve gradients of 35 MV/m at the cathode position. With the cathode inserted CW operation has been achieved at 20 MV/m with good control of microphonics, negligible dark current, and Q 0 > 3×10 9 at 4 K. Bunch charges of ~100 pC have been delivered, and first simple beam measurements made. These preliminary results are very encouraging for production of 100s pC bunches with millimeter-milliradian or smaller normalized emittances. Plans are in place to carry out more definitive studies to establish the full capabilities. However, since the grant was not renewed, the electron gun is currently mothballed, and without supplemental fund the opportunity for further work will be lost.

43 PARTICLE ACCELERATORS↗

Construction and Test of a Novel Superconducting RF Electron Gun

The University of Wisconsin-Madison has completed installation of a superconducting electron gun. Its concept was optimized to be the source for a CW free electron laser facility with multiple megahertz repetition rate end stations. This VHF superconducting configuration holds the promise of the highest performance for CW injectors. Initial commissioning efforts show that the cavity can achieve gradients of 35 MV/m at the cathode position. With the cathode inserted CW operation has been achieved at 20 MV/m with good control of microphonics, negligible dark current, and Q o > 3xl0 9 at 4 K. Bunch charges of~100 pC have been delivered, and first simple beam measurements made. These preliminary results are very encouraging for production of lOOspC bunches with millimeter-milliradian or smaller normalized emittances. Plans are in place to carry out more definitive studies to establish the full capabilities. However, since the grant was not renewed, the electron gun is currently mothballed, and without supplemental fund the opportunity for further work will be lost.

Bisognano, Joseph P.↗

ELECTRON BEAM SHAPING AND ITS APPLICATIONS

Transverse and longitudinal electron beam shaping is a crucial part of high-brightness electron accelerator operations. In this dissertation, we report on the corresponding beam dynamics research conducted at Fermilab Accelerator Science and Technology facility (FAST) and Argonne Wakeeld Accelerator (AWA). We demonstrate an experimental method for spatial laser and electron beam shaping using microlens arrays (MLAs) at a photoinjector facility. Such a setup was built at AWA and resulted in transverse emittance reduction by a factor of 2. We present transverse emittance partitioning methods that were recently employed at FAST facility. A strongly coupled electron beam was generated in an axial magnetic eld and accelerated in 1.3 GHz SRF cavities to 34 MeV. It was then decoupled in Round-To-Flat beam transformer and beams with emittance asymmetry ratio of 100 were generated. We introduce the new methods of measuring electron beam canonical angular momentum, beam transformer optimization and beam image analysis. We also describe a potential longitudinal space-charge amplier setup for FAST high-energy beamline. As an outcome, a broadband partially coherent radiation in the UV range could be generated.

43 PARTICLE ACCELERATORS↗

Contextual modeling and Bayesian Optimization for Improved Injection at the Fermilab Booster

The Fermilab accelerator complex delivers high-intensity proton beams to serve the lab’s neutrino, muon, and fixed-target programs. A normal-conducting Linac accelerates H− beam to 400 MeV and injects into the Booster rapid cycling synchrotron via charge exchange, which accelerates protons to 8 GeV. Injection from the Linac into the Booster is a critical area for high-power performance of the Fermilab proton complex. The Booster is a high-intensity proton ring with extreme space-charge forces which necessitates precise control over the beam losses through the acceleration cycle. The main challenge for the reliability of Booster performance is compensating for drifting conditions in the beam from the Linac, which can drift daily in energy by up to O(1) MeV w.r.t. design. Drifts in Linac orbit and energy must be corrected to match the Booster, while simultaneously accommodating interdependent drifts in transverse and longitudinal beam quality. Operationally, compensation for these changes is addressed by manual tuning of the Linac output energy and/or Booster acceptance, which can be inefficient and time-consuming. This works describes contextual Bayesian Optimization for injection tuning that takes into account the state of Linac beam via information from instrumentation in the injection line (Beam position monitors (BPMs), beam loss monitors (BLMs), wire scanners for transverse profiles (WSs)), as well as RF cavity setting parameters from the Linac.

Sharankova, R. [Fermilab] (ORCID:000000027014593X)↗

Multiphase reacting flow modeling of singlet oxygen generators for chemical oxygen iodine lasers.

Singlet oxygen generators are multiphase flow chemical reactors used to generate energetic oxygen to be used as a fuel for chemical oxygen iodine lasers. In this paper, a theoretical model of the generator is presented along with its solutions over ranges of parameter space and oxygen maximizing optimizations. The singlet oxygen generator (SOG) is a low-pressure, multiphase flow chemical reactor that is used to produce molecular oxygen in an electronically excited state, i.e. singlet delta oxygen. The primary product of the reactor, the energetic oxygen, is used in a stage immediately succeeding the SOG to dissociate and energize iodine. The gas mixture including the iodine is accelerated to a supersonic speed and lased. Thus the SOG is the fuel generator for the chemical oxygen iodine laser (COIL). The COIL has important application for both military purposes--it was developed by the US Air Force in the 1970s--and, as the infrared beam is readily absorbed by metals, industrial cutting and drilling. The SOG appears in various configurations, but the one in focus here is a crossflow droplet generator SOG. A gas consisting of molecular chlorine and a diluent, usually helium, is pumped through a roughly rectangular channel. An aqueous solution of hydrogen peroxide and potassium hydroxide is pumped through small holes into the channel and perpendicular to the direction of the gas flow. So doing causes the solution to become aerosolized. Dissociation of the potassium hydroxide draws a proton from the hydrogen peroxide generating an HO{sub 2} radical in the liquid. Chlorine diffuses into the liquid and reacts with the HO{sub 2} ion producing the singlet delta oxygen; some of the oxygen diffuses back into the gas phase. The focus of this work is to generate a predictive multiphase flow model of the SOG in order to optimize its design. The equations solved are the so-called Eulerian-Eulerian form of the multiphase flow Navier-Stokes equations wherein one set of the equations represents the gas phase and another equation set of size m represents the liquid phase. In this case, m is representative of the division of the liquid phase into distinct representations of the various droplet sizes distributed in the reactor. A stabilized Galerkin formulation is used to solve the equation set on a computer. The set of equations is large. There are five equations representing the gas phase: continuity, vector momentum, heat. There are 5m representing the liquid phase: number density, vector momentum, heat. Four mass transfer equations represent the gas phase constituents and there are m advection diffusion equations representing the HO{sub 2} ion concentration in the liquid phase. Thus we are taking advantage of and developing algorithms to harness the power of large parallel computing architectures to solve the steady-state form of these equations numerous times so as to explore the large parameter space of the equations via continuation methods and to maximize the generation of singlet delta oxygen via optimization methods. Presented here will be the set of equations that are solved and the methods we are using to solve them. Solutions of the equations will be presented along with solution paths representing varying aerosol loading-the ratio of liquid to gas mass flow rates-and simple optimizations centered around maximizing the oxygen production and minimizing the amount of entrained liquid in the gas exit stream. Gas-entrained liquid is important to minimize as it can destroy the lenses and mirrors present in the lasing cavity.

42 ENGINEERING↗

Single-frequency TEA CO{sub 2} laser with a bleaching spectral intracavity filter

The regime of single-frequency operation is realised in a TEA CO{sub 2} laser with a spectral filter inside the cavity (a cell filled with SF{sub 6}) on P(12)–P(24) lines of the 10P band. The minimal scatter of the peak powers of the laser pulses in a series of ‘shots’ and the maximal ratio of the output energies in the single-frequency and free running regimes (greater than 0.84) are obtained on the P(16) line at an optimal SF{sub 6} pressure in the cell. Experimental results qualitatively agree with the absorption spectrum of SF{sub 6} calculated from the SPECTRA information-analytical system. It is shown that the high ratio of energies in two regimes is achived due to gas bleaching in the cell. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PIP-II High Beta 650 Prototype Cryomodule Assembly Experience and Related Design Optimization

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.

Ozelis, J.↗

A dosimetric comparative study: Volumetric modulated arc therapy vs intensity-modulated radiation therapy in the treatment of nasal cavity carcinomas

The purpose of this study was to evaluate the differences between volumetric modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) in the treatment of nasal cavity carcinomas. The treatment of 10 patients, who had completed IMRT treatment for resected tumors of the nasal cavity, was replanned with the Philips Pinnacle{sup 3} Version 9 treatment-planning system. The IMRT plans used a 9-beam technique whereas the VMAT (known as SmartArc) plans used a 3-arc technique. Both types of plans were optimized using Philips Pinnacle{sup 3} Direct Machine Parameter Optimization algorithm. IMRT and VMAT plans' quality was compared by evaluating the maximum, minimum, and mean doses to the target volumes and organs at risk, monitor units (MUs), and the treatment delivery time. Our results indicate that VMAT is capable of greatly reducing treatment delivery time and MUs compared with IMRT. The reduction of treatment delivery time and MUs can decrease the effects of intrafractional uncertainties that can occur because of patient movement during treatment delivery. VMAT's plans further reduce doses to critical structures that are in close proximity to the target volume.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structure-based design of prefusion-stabilized human metapneumovirus fusion proteins

The human metapneumovirus (hMPV) fusion (F) protein is essential for viral entry and is a key target of neutralizing antibodies and vaccine development. The prefusion conformation is thought to be the optimal vaccine antigen, but previously described prefusion F proteins expressed poorly and were not well stabilized. Here, we use structures of hMPV F to guide the design of 42 variants containing stabilizing substitutions. Through combinatorial addition of disulfide bonds, cavity-filling substitutions, and improved electrostatic interactions, we describe a prefusion-stabilized F protein (DS-CavEs2) that expresses at 15mg/L and has a melting temperature of 71.9°C. Crystal structures of two prefusion-stabilized hMPV F variants reveal that antigenic surfaces are largely unperturbed. Importantly, immunization of mice with DS-CavEs2 elicits significantly higher neutralizing antibody titers against hMPV A1 and B1 viruses than postfusion F. The improved properties of DS-CavEs2 will advance the development of hMPV vaccines and the isolation of therapeutic antibodies.

59 BASIC BIOLOGICAL SCIENCES↗

A 15-Mev/nucleon Iso-Cyclotron for Security and Radioisotope Production

Cargo inspection systems exploit the broad bremsstrahlung spectrum from a 6-10 MeV, low-duty cycle electron accelerator which in the presence of significant backgrounds presents challenges in image and material identification. An alternative approach is to use ions which can excite nuclear states either directly, or through generation of secondary high-energy signature gammas produced from nuclear interactions in a target. RadiaBeam is designing a compact sector isocyclotron 1.25 m in radius, with high-gradient cavities to accelerate multi-ion species up to 15-20 MeV/u with large turn-to turn, centimeter-level separation for low-loss extraction without lossy foil stripping. A strong-focusing radial field profile will be optimized in a separated-sector format for control over machine tune simultaneous with isochronous orbist requirements for high-current (~0.5 milliamp) operation. Innovation in injection will be introduced to replace the high-loss central region. Non-security applications of the cyclotron include medical isotope production, ion radiobiology, as well as material science research and ion instrumentation development.

43 PARTICLE ACCELERATORS↗

Recent improvements to software used for optimization of SRF linacs

This work describes a software tool that allows one to vary parameters and understand the effects on the optimized costs of construction plus 10 year operations of an SRF linac, where operation costs includes the cost of the electrical utilities but not the labor or other costs. The program includes estimates for the associated cryogenic facility, and controls hardware. The software interface provides the ability to vary the cost of the different aspects of the machine as well as to change the cryomodule and cavity types. Additionally, this work will describe the recent improvements to the software that allow one to estimate the costs of energy-recovery based linacs and to enter arbitrary values of the low field Q0 and Q0 slope. The initial goal when developing the software was to convert a spreadsheet format to a graphical interface and to allow the ability to sweep different parameter sets. The tools also allow one to compare the cost of the different facets of the machine design and operations so as to better understand tradeoffs. An example of how it was used to independently investigate cost optimization tradeoffs for the LCLS-II linac will also be presented.

Powers, Tom J.↗

Possibility of using cylindrical ionization chambers for percent depth-dose measurements in clinical electron beams

Purpose: This study investigated the possibility of using cylindrical ionization chambers for percent depth-dose (PDD) measurements in high-energy clinical electron beams. Methods: The cavity correction factor, P{sub cav}, for cylindrical chambers with various diameters was calculated as a function of depth from the surface to R{sub 50}, in the energy range of 6-18 MeV electrons with the EGSnrc C ++ -based user-code CAVITY. The results were compared with those for IBA NACP-02 and PTW Roos parallel-plate ionization chambers. The effective point of measurement (EPOM) for the cylindrical chamber and the parallel-plate chamber was positioned according to the IAEA TRS-398 code of practice. The overall correction factor, P{sub Q}, and the percent depth-ionization (PDI) curve for a PTW30013 Farmer-type chamber were also compared with those of NACP-02 and Roos chambers. Results: The P{sub cav} values at depths between the surface and R{sub 50} for cylindrical chambers were all lower than those with parallel-plate chambers. However, the variation in depth for cylindrical chambers equal to or less than 4 mm in diameter was equivalent to or smaller than that for parallel-plate chambers. The P{sub Q} values for the PTW30013 chamber mainly depended on P{sub cav}, and for parallel-plate chambers depended on the wall correction factor, P{sub wall}, rather than P{sub cav}. P{sub Q} at depths from the surface to R{sub 50} for the PTW30013 chamber was consequently a lower value than that with parallel-plate chambers. However, the variation in depth was equivalent to that of parallel-plate chambers at electron energies equal to or greater than 9 MeV. The shift to match calculated PDI curves for the PTW30013 chamber and water (perturbation free) varied from 0.65 to 0 mm between 6 and 18 MeV beams. Similarly, the shifts for NACP-02 and Roos chambers were 0.5-0.6 mm and 0.2-0.3 mm, respectively, and were nearly independent of electron energy. Conclusions: Calculated PDI curves for PTW30013, NACP-02, and Roos chambers agreed well with that of water by using the optimal EPOM. Therefore, the possibility of using cylindrical ionization chambers can be expected for PDD measurements in clinical electron beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Superadiabatic scheme for optimizing the fast generation of tree-type 3D entanglement

High-dimensional entanglement has more superior security than qubit entanglement. Recently, adiabatic and fast-adiabatic schemes for generating a novel three-dimensional (3D) entanglement, tree-type 3D entanglement, were proposed. However, the previous schemes have their experimental defects, respectively. Here we give a superadiabatic scheme for optimizing the generation of tree-type 3D entanglement. Adequate numerical simulations prove that the scheme is not only fast, effective and robust, but also highly feasible in experiment. - Highlights: • The scheme for generating tree-type 3D entanglement is not only fast but also robust against the variation in the control parameters and decoherence induced by atomic spontaneous emissions and photon leakages from the cavity-fiber system. • The designed driving pulses are experimentally feasible Gaussian pulses which can reduce experimental difficulties. • The Hamiltonian used to speed up generating tree-type 3D entanglement is of the same form as the original Hamiltonian, which will greatly enhances the experimental feasibility of the scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-CD-209-02: Beam Angle Optimization Incorporating Anatomical Heterogeneities for Pencil Beam Scanning Charged-Particle Therapy

Purpose: In charged particle therapy with pencil beam scanning (PBS), localization of the dose in the Bragg peak makes dose distributions sensitive to lateral tissue heterogeneities. Sensitivity of a PBS plan to lateral tissue heterogeneity can be reduced by selecting suitable beam angles. The purpose of this study is to establish a fast and accurate method of beam angle selection for PBS. Methods: The lateral tissue heterogeneity surrounding the path of respective pencil beams at a given angle was quantified with the heterogeneity number using effective density data of patients. To shorten the computation time, one dimensional dose calculation and optimization were conducted along the central axis of pencil beams originating from the scanning magnets. Calculation was performed for all fields with possible gantry and couch angles. The angles leading the minimum mean heterogeneity number was selected as the optimal beam angle. Three head and neck (H&N) cancer patients were used to evaluate our method. Dose distributions and their robustness to range and set up errors were evaluated for all tested angles, and their relation to their heterogeneity numbers were investigated. Results: Variety of heterogeneity number was clearly shown due to air cavities and bony structures in the patients. The mean value of heterogeneity number in all possible fields varied between 1.2 and 10.6 mm. By selecting a field with a lower mean value of heterogeneity number, target dose coverage and robustness of the fields were improved. Conclusion: We developed a computational method to determine a beam angle that leads good target coverage and robustness to setup errors. The developed stand-alone computation program is simple, fast, accurate and applicable for beam angle selection in PBS therapy.

60 APPLIED LIFE SCIENCES↗

MRI- Versus CT-Based Volume Delineation of Lumpectomy Cavity in Supine Position in Breast-Conserving Therapy: An Exploratory Study

Purpose: To examine magnetic resonance imaging (MRI) and computed tomography (CT) for lumpectomy cavity (LC) volume delineation in supine radiotherapy treatment position and to assess the interobserver variability. Methods and Materials: A total of 15 breast cancer patients underwent a planning CT and directly afterward MRI in supine radiotherapy treatment position. Then, 4 observers (2 radiation oncologists and 2 radiologists) delineated the LC on the CT and MRI scans and assessed the cavity visualization score (CVS). The CVS, LC volume, conformity index (CI), mean shift of the center of mass (COM), with the standard deviation, were quantified for both CT and MRI. Results: The CVS showed that MRI and CT provide about equal optimal visibility of the LC. If the CVS was high, magnetic resonance imaging provided more detail of the interfaces of the LC seroma with the unaffected GBT. MRI also pictured in more detail the interfaces of axillary seromas (if present) with their surroundings and their relationship to the LC. Three observers delineated smaller, and one observer larger, LC volumes comparing the MRI- and CT-derived delineations. The mean {+-} standard deviation CI was 32% {+-} 25% for MRI and 52% {+-} 21% for CT. The mean {+-} standard deviation COM shift was 11 {+-} 10 mm (range 1-36) for MRI and 4 {+-} 3 mm (range 1-10) for CT. Conclusions: MRI does not add additional information to CT in cases in which the CVS is assessed as low. The conformity (CI) is lower for MRI than for CT, especially at a low CVS owing to greater COM shifts for MRI, probably caused by inadequate visibility of the surgical clips on magnetic resonance (MR) images. The COM shifts seriously dictate a decline in the CI more than the variability of the LC volumes does. In cases in which MRI provides additional information, MRI must be combined with the CT/surgical clip data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photoelectron spectroscopy and computational investigations of the electronic structures and noncovalent interactions of cyclodextrin-closo-dodecaborate anion complexes x-CD·B12X122- (x = a, ß, y; X = H, F)

We report a joint negative ion photoelectron spectroscopy (NIPES) and computational study on the electronic structures and noncovalent interactions of a series of cyclodextrin-closo-dodecaborate dianion complexes, ?-CD·B12X122- (? = a, ß, ?; X = H, F). The measured vertical / adiabatic detachment energies (VDEs / ADEs) are 1.15/0.93, 3.55/3.20, 3.90/3.60, and 3.85/3.60 eV for B12H122- and its a-, ß-, ?-CD complexes, respectively; while the corresponding values are 1.90/1.70, 4.00/3.60, 4.33/3.95, and 4.30/3.85 eV for the X = F case. These results show that the inclusion of B12X122- into the CD cavities greatly increase the electronic stability of the dianions. The effect of electronic stabilization for ß-CD is roughly the same as for ?-CD, both being considerably stronger than that for a-CD. Density functional theory (DFT) based geometry optimization reveals that B12X122- are inserted into CDs increasingly deeper from a-CD to ?-CD. The calculated VDEs and ADEs agree with the experiments well, particularly, reproducing the electron binding energy (EBE) trends. The molecular orbital analyses indicate that the most loosely bound photodetached electrons origin from the guest B12X122- moieties. In addition to a shift of all signals to larger EBE, significant changes in the signal patterns are observed. At low EBE, this is due to the splitting of highly degenerate B12X122- orbitals, while at high EBE, photodetachment from CD oxygens contributes to the new bands. The guest B12X122- and host CD nocovalent, size-specific interaction based on the independent gradient model (IGM) and energy decomposition analysis (EDA), is dominated by electrostatic interactions. The analysis further unravels unambiguiously the existence of dihydrogen bonding and how it affects the total energy that stabilizes the host-guest complexes of CDs·B12H122- compared to the general hydrogen bonding interaction in CDs·B12F122-. This work clearly exhibits strong influences on the electronic structures of dodecaborates upon clustering with CDs, with both size (a-, ß-, ?-) and molecular (X = H or F) specificities, thus providing critical molecular-level information on the cyclodextrin-closo-dodecaborate interactions of interest to medical applications, e.g. Boron neutron capature therapy. The NIPES experiments done at PNNL were supported by the U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Bioscience (X.-B.W.) and was performed at the EMSL, a national scientific user facility sponsored by DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory. H.S. and Z.S. acknowledge the funding support of National Natural Science Foundation of China (Nos.11727810, 61720106009 and 21603074), the Science and Technology Commission of Shanghai Municipality (Nos. 19JC1412200), and the Program of Introducing Talents of Discipline to Universities 111 project (B12024). Z. L. thanks the China Scholarship Council (CSC) for financial support. We acknowledge the ECNU Multifunctional Platform for Innovation (001) and HPC Research Computing Team for providing computational and storage resources. J.W. acknowledges support from the Alexander von Humboldt foundation (Feodor Lynen Fellowship and Rückkehrerstipendium), a Freigeist fellowship of the Volkswagenfoundation and Prof. Vladimir A. Azov for helpful discussions.

Li, Zhipeng↗