Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “care”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Quantifying Medical Risk on a Long Duration Lunar Mission: A Demonstration of NASA’s IMPACT Tradespace Analysis Tool

Background NASA’s human exploration spaceflight missions to the Moon and Mars present unprecedented challenges for in-mission medical care. The distance from Earth will mean increased mission durations, communication delays, limited to no resupply opportunities, and constraints on the medical evacuation of astronauts. Mass, volume, power, and data will be limited while higher demands will be placed on the crew to manage medical care. NASA’s Moon to Mars exploration strategy lays out increasingly complex Artemis missions both in terms of duration and operations. In these more challenging deep space missions, it is important to quantitatively estimate the human medical risk to inform a traditional heuristic approach to medical risk. Prior tools have been developed for missions in low Earth orbit, but a new tool is required to plan for future exploration missions. Methods IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments; an expanded list of 119 medical conditions; the addition of medical resources; and the ability for rapid and iterative analysis. Medical system risk estimates include loss of crew life, consideration of the need for return to definitive care (medical evacuation), and an estimate of crew time affected due to medical conditions. A notional long duration lunar orbit and lunar surface design reference mission (DRM) was chosen with a 4-astronaut crew to represent a sustained exploration Artemis mission. Results/Discussion Overall, IMPACT successfully quantified medical risk and derived an optimized medical system to support crew on a long duration lunar mission. In this DRM, the calculated loss of crew life from a medical event was 0.008 events per mission, risk of potential need for evacuation was 0.30 events per mission, and cumulative crew time affected by medical conditions was 103 days. The medical conditions that most contributed to overall medical risk were decompression sickness, trauma conditions, and respiratory failure. The conditions that had the largest effects on crew performance included musculoskeletal injuries and lunar dust exposure. The IMPACT-generated medical system included resources that target the most common and highest risk conditions. This systematic analysis demonstrates the value of the IMPACT tool in medical system design for human exploration spaceflight missions.

Missions to Mars↗

Current Status of Martian Moons eXploration (MMX) Contamination Control and Curation Activity

Martian Moons eXploration (MMX) is a sample return mission from the Martian moon Phobos. The MMX spacecraft is scheduled to launch in 2026 and return to Earth in 2031. The main science goals of MMX are “to reveal the origin of the Martian moons and make progress in the understanding of planetary system formation and material transport in the solar system, and to observe processes that impact the circumplanetary and surface environments of Mars”. MMX has two sampling systems: coring (C)-sampler and pneumatic (P)-sampler and plans to bring back >10 g of Phobos sample. The retuned sample in the sample capsule will be transferred to the curation facility in ISAS/JAXA for sample curation and subsequent sample analysis. Contamination control of the sample return mission requires special care to prevent terrestrial contamination to the spacecraft, which would ruin the scientific value of the returned sample. Retaining the pristineness of the retuned sample is an important task of the MMX Curation and Sampler Science teams. The basis of the contamination control is (1) to minimize and understand the nature and amount of contaminants, (2) to perform contamination assessment and evaluate the effect of contaminants in the spacecraft on the retuned sample, (3) to employ a contamination knowledge (CK) material coupon in the spacecraft to identify the contaminants in the returned samples. In the MMX contamination control plan, the allowable contamination level for each contaminant is carefully defined. They are mostly set to be 1/1000 of the expected amount of each material in the returned sample and are divided into two main categories: organic and inorganic. The allowable atmospheric leakage rate to the sample container is also defined. The allowable contamination level of the organic materials is based on the composition of carbonaceous chondrites. The target contaminants are amino acids, aliphatic and aromatic hydrocarbons, carboxylic acids, etc. In case of the inorganic materials, the target contaminants are important elements to permit distinguishing the origin of the Martian moon by nucleosynthetic isotope anomalies (Cr, Ti, and Mo) and to reveal the evolution of the Martian moon by chronology (Hf, W, U, Pb, Rb, Sr, Sm, and Nd). The key instrument of contamination control in the sample return mission is the sampler system. The C-sampler has been developed by JAXA and the P-sampler was provided by Honeybee/NASA. In MMX, materials used in the two samplers (C- and P- sampler) were carefully selected to avoid potential contamination from the design stage of the system. The individual parts of the C-sampler FM (Flight Model) were thoroughly cleaned at the curation facility in ISAS/JAXA by the full-course cleaning procedure, which is an ultrasonic cleaning with organic solvents and ultrapure water in several steps. The equivalent level of cleaning was also carried out on the P-Samper FM as well by Honeybee Robotics in the USA. Now, MMX is in the critical phase for contamination control called ATLO: Assembly, Test, and Launch Operations. During the ATLO phase, sampler FM is constantly purged with nitrogen gas and maintained at positive pressure to prevent environmental contamination. The surrounding environments of the sampler FM are also simultaneously monitored using the CK Monitoring Coupon Set, which consists of several witness materials such as a glass petri dish, sapphire glass disk, and carbon adhesive tape (Figure 1). The detailed environmental assessment of each clean room used for the assembly and test of the sampler FM has also been conducted. This assessment includes microbial analysis, which was performed for OSIRIS-REx. Regarding the sample recovery and sample curation, we have started the designing of Sample Container Disassembling Instrument for the sample recovery from the sample container and the MMX curation chamber for sample curation. The curation protocol for the Phobos returned sample has also been discussed by the MMX Sample Analysis Working Team (SAWT). The MMX curation protocol consists of three phases: (1) quick analysis, (2) pre-basic characterization, and (3) basic characterization. (1) is extraction of the sample gas from the sample container and analysis by mass spectrometry, (2) is observation in bulk level, and (3) is observation in grain level and allocation of the sample aliquots. In parallel with the curation protocol, the returned sample undergoes preliminary examination for scientific investigations to achieve science goals. In addition, the CK witness plates made of sapphire glass are on board the sampler system. The CK witness plates will be recovered from the sampler system and analyzed by SAWT for the assessment of in-flight contamination.

Haruna Sugahara↗

Assessing the Added Value of Miniature X-Ray in the Setting of US in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in lowEarth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

Jon Steller↗

The Magnox Clean-Up Programme - Integrating and Making Best Use of the Supply Chain - 16603

In 2010, the UK Nuclear Decommissioning Authority (NDA) secured a funding settlement of British Pounds 2.5 Bn from the Government for the period to 2015 for the Magnox Care and Maintenance programme. This settlement was a reflection of the importance placed on discharging the decommissioning liability associated with the UK's first generation Magnox reactors. It also reflected the NDA's confidence in the Magnox Optimised Decommissioning Plan (MODP), which aimed to accelerate entry into Care and Maintenance and reduce the Magnox decommissioning liability by British Pounds 1.2 Bn. Despite the settlement, huge challenges remained if the MODP was to be delivered within the funding envelope. Essentially, the supply chain had to be able to participate in the delivery of the MODP and make the investment in skills and techniques required to minimise the threats and uncertainties remaining in the Programme. The Magnox Commercial and Supply Chain Strategy was, therefore, an integral part of the MODP. At the highest level, the Strategy involved: - Classifying and segregating procurements by risk and value - Moving the contracting philosophy from risk transfer to risk management - Focusing on relationships and results rather than activities and processes By aligning the supply chain to the MODP, Magnox was able to better organise itself to deliver against the MODP, to act on feedback from suppliers and enable a culture of 'Lead and Learn' to take root. Using feedback and learning from other organisations and applying these to contract management approaches improved project outcomes. In particular, learning from previous experience of dealing with Programme 'unknowns' increased the company's ability to control and improve on the overall Programme cost and schedule. The impact of the MODP was to reduce the Magnox baseline by over British Pounds 1.5 Bn and remove 34 reactor-years from the Care and Maintenance preparations period. This huge gain resulted from a range of technical, process and commercial improvements across the organisation. Perhaps the greatest achievement of the MODP and its supply chain strategy was to quantify and stabilise the Magnox Life-cycle scope and cost and enable the successful competition and transfer of the Management and Operating (M and O) contract in 2014 and lay the foundations for further cost-savings to the UK taxpayer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of an Analytical Model for Therapeutic and Stray Dose Calculations of 6 MV Photon Beams

Cancer is one of the most significant health care problems today. It is estimated that 1 in 2 men and women will be diagnosed with some form of cancer in their lifetime. Nearly two thirds of cancer patients will receive radiation therapy at some point in their care and the vast majority of these radiotherapy treatments will be performed with megavoltage photon therapy. Photon treatment techniques typically devote considerable attention to limiting the exposure of healthy tissues outside of the intended treatment volume. Nonetheless, small levels of unwanted stray radiation are incident upon the patient's whole body, which can increase the risk for numerous late effects, including second malignancies. When one considers that second cancers account for approximately 15% of all cancers and that it is projected that by the year 2020, there will be almost 20 million cancer survivors in the United States and four million in the UK, the need for improved accuracy in stray dose calculations appears likely to increase dramatically. Despite the obvious benefits this capability would afford, contemporary commercial treatment planning systems (TPSs) lack the ability to accurately predict stray dose outside the treatment field, e.g., beyond the 5% isodose surface. Thus, there is a large, variable, and systematic underestimation of stray radiation exposures by commonly used clinical TPSs for photon therapy. To overcome this problem, in a companion paper we proposed a simple, physics-based analytical model that calculates the total therapeutic and stray dose from photon treatment fields. The purpose of this work was to evaluate the accuracy of the basic physics in the analytical absorbed dose model for several simple treatment fields. We assessed the performance of the basic physics in an analytical model that calculates the total absorbed dose deposited by primary, leakage, and scattered photons both inside and outside of square treatment fields of 6 MV photon conventional radiotherapy. The assessment was accomplished by comparing model predictions of total dose with measured dose profiles in a water-phantom. The major finding of this study is that the physics-based model performed well, predicting dose in water within 11.5% dose difference or 5 mm distance to agreement with measured values in the therapeutic region and within 1.1 mGy/Gy or 0.5 mm distance to agreement with measured values in the out-of-field region at 90% of the locations considered. Contemporary external-beam photon TPSs do not include the capability to accurately predict the absorbed dose beyond a few centimeters outside of the treatment field. Our work suggests that it is feasible to improve dosimetric accuracy in the out-of-field region using a simple and computationally fast, physics-based analytical algorithm. This is demonstrated by the measured absorbed dose as well as the corresponding values calculated by two contemporary commercial TPSs (Pinnacle, Philips Health care, Andover, MA and Eclipse, Varian Medical Systems, Inc., Palo Alto, CA) and the analytical model considered in this work. It is apparent that both TPSs underestimated the absorbed dose by greater than 3 mGy/Gy at locations outside of the 0.5% relative dose level. In contrast, the analytical model evaluated in this work calculated absorbed dose in the same region within 0.4 mGy/Gy of measured values. The physics-based analytical dose model could prove useful in a number of different applications. The accurate knowledge of absorbed dose deposited outside of the treatment field is especially important for predicting radiation late effects, such as second cancer, fertility complications, and cardiac toxicity. It may also facilitate predictions of the effects of in utero exposure. We conclude that it is possible to accurately calculate the therapeutic and stray absorbed dose from a conventional radiotherapy treatment field of 6 MV photons using a physics-based analytical model. This was demonstrated by the agreement between measured and calculated doses in water within 11.5% relative dose difference or 5 mm distance to agreement in the therapeutic region, and within 1.1 mGy/Gy absolute dose difference or 0.5 mm distance to agreement in the out-of-field region at 90% of positions for all of the fields considered in this work. This is also illustrated by Figure 4 which plots dose values from analytical model predictions and measurements at five representative irradiation conditions and shows that the analytical model agreement is good in all cases. Furthermore, the model validated in this work evidently can predict dose values with better accuracy at out-of-field locations than contemporary TPSs. This and previous works, taken together, suggest that analytical physics-based models will offer advantages over TPSs or Monte Carlo models for whole-body dose calculations for several radiotherapy applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Use of Artificial Intelligence in Head and Neck Cancers: A Multidisciplinary Survey

Artificial intelligence (AI) approaches have been introduced in various disciplines but remain rather unused in head and neck (H&N) cancers. This survey aimed to infer the current applications of and attitudes toward AI in the multidisciplinary care of H&N cancers. From November 2020 to June 2022, a web-based questionnaire examining the relationship between AI usage and professionals’ demographics and attitudes was delivered to different professionals involved in H&N cancers through social media and mailing lists. A total of 139 professionals completed the questionnaire. Only 49.7% of the respondents reported having experience with AI. The most frequent AI users were radiologists (66.2%). Significant predictors of AI use were primary specialty (V = 0.455; p < 0.001), academic qualification and age. AI’s potential was seen in the improvement of diagnostic accuracy (72%), surgical planning (64.7%), treatment selection (57.6%), risk assessment (50.4%) and the prediction of complications (45.3%). Among participants, 42.7% had significant concerns over AI use, with the most frequent being the ‘loss of control’ (27.6%) and ‘diagnostic errors’ (57.0%). This survey reveals limited engagement with AI in multidisciplinary H&N cancer care, highlighting the need for broader implementation and further studies to explore its acceptance and benefits.

60 APPLIED LIFE SCIENCES↗

Cross‐Cultural Validation of the Binge Eating Disorder Screener‐7 ( BEDS ‐7) Across 42 Countries

ABSTRACT Objective This study aimed to evaluate the reliability and validity of the Binge Eating Disorder Screener‐7 (BEDS‐7) across 42 countries and 26 languages, assessing its reliability and validity as a screening tool for binge‐eating disorder (BED) in diverse cultural contexts. Specifically, it sought to enhance early recognition of BED symptoms in primary care settings globally, contributing to a standardized framework for assessing BED. Method The International Sex Survey, a cross‐sectional online study, was conducted in 42 countries and 26 languages. A diverse community sample of 82,243 participants, aged 18 years or older, completed the BEDS‐7 and measures of sexuality, mental health, substance use, and sociodemographic characteristics. Confirmatory factor analyses and tests of measurement invariance were employed to evaluate the reliability and validity of the BEDS‐7 across languages, countries, genders, and sexual orientations. Results The BEDS‐7 demonstrated scalar factorial invariance across languages and countries, indicating consistent factor loadings and item intercepts. In contrast, the screener showed residual invariance across gender and sexual orientation groups, supporting its robustness across these demographics. Kruskal–Wallis tests revealed significant differences in BED symptoms across languages, countries, genders, and sexual orientations, with the highest BED scores observed among queer, pansexual, and gender‐diverse individuals. The BEDS‐7 also demonstrated adequate reliability (Cronbach's alpha > 0.80) and moderate criterion validity. Discussion The findings provide further evidence of the reliability and validity of the BEDS‐7 as a potential screening tool for identifying probable cases of BED globally, facilitating early intervention in primary care settings.

Gewirtz‐Meydan, Ateret [School of Social Work, Fac↗

Comparing variability in diagnosis of upper respiratory tract infections in patients using syndromic, next generation sequencing, and PCR-based methods

Early and accurate diagnosis of respiratory pathogens and associated outbreaks can allow for the control of spread, epidemiological modeling, targeted treatment, and decision making–as is evident with the current COVID-19 pandemic. Many respiratory infections share common symptoms, making them difficult to diagnose using only syndromic presentation. Yet, with delays in getting reference laboratory tests and limited availability and poor sensitivity of point-of-care tests, syndromic diagnosis is the most-relied upon method in clinical practice today. Here, we examine the variability in diagnostic identification of respiratory infections during the annual infection cycle in northern New Mexico, by comparing syndromic diagnostics with polymerase chain reaction (PCR) and sequencing-based methods, with the goal of assessing gaps in our current ability to identify respiratory pathogens. Of 97 individuals that presented with symptoms of respiratory infection, only 23 were positive for at least one RNA virus, as confirmed by sequencing. Whereas influenza virus (n = 7) was expected during this infection cycle, we also observed coronavirus (n = 7), respiratory syncytial virus (n = 8), parainfluenza virus (n = 4), and human metapneumovirus (n = 1) in individuals with respiratory infection symptoms. Four patients were coinfected with two viruses. In 21 individuals that tested positive using PCR, RNA sequencing completely matched in only 12 (57%) of these individuals. Few individuals (37.1%) were diagnosed to have an upper respiratory tract infection or viral syndrome by syndromic diagnostics, and the type of virus could only be distinguished in one patient. Thus, current syndromic diagnostic approaches fail to accurately identify respiratory pathogens associated with infection and are not suited to capture emerging threats in an accurate fashion. We conclude there is a critical and urgent need for layered agnostic diagnostics to track known and unknown pathogens at the point of care to control future outbreaks.

60 APPLIED LIFE SCIENCES↗

NRAP-Open-IAM: NRAP Open Source Integrated Assessment Model

Note: This is the last version (a2.6.1) of NRAP-Open-IAM released during NRAP Phase II in 2022. The latest version of NRAP-Open-IAM is available here: https://edx.netl.doe.gov/dataset/phase-iii-nrap-open-iam NRAP-Open-IAM is an open-source software product that enables quantification of containment effectiveness and leakage risk at storage sites in the context of system uncertainties and variability. NRAP-Open-IAM represents the next-generation in a line of systems-based computational models developed for quantitative geological carbon storage (GCS) risk assessment. The model comprises a set of reduced-order and analytical models of various components of the GCS system, potential leakage pathways, receptors of concern including impact to groundwater resources and the atmosphere, a framework to support stochastic simulation, time stepping, uncertainty quantification, other analytical functionality for scenario and risk-performance evaluation, and a basic graphical user interface to support scenario development, data input simulation definition, and basic post-processing and results display. As the NRAP Open-IAM functionality continues to evolve, we continue to add to its capability to develop quantitative, probabilistic, and time-dependent profiles of the evolution of risk at a GCS site and evaluate the influence of uncertain parameters on uncertainty in predicted risk. It can be used to quantify the dynamics of reservoir saturation plume and pressure-affected area, for evaluation of the area of potential groundwater impact (i.e., Area of Review) and monitoring requirements to support cost and regulatory analysis, and for consideration of different post-injection site care and closure scenarios. This submission contains the current version of NRAP-Open-IAM available for evaluation and testing. To use the NRAP-Open-IAM, download the source code (https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/4c24a3da-3b40-4ffe-9892-c807ae9f8760) then open the NRAP-Open-IAM user's guide (https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/8b27335a-343c-4836-b8a3-3ad0bdc9e669) to read more about the tool. Installation instructions for Windows, Mac, and Linux can be found in the "installers" folder of the extracted NRAP-Open-IAM folder and describe setup of environment (e.g., Python libraries) needed for proper work of the tool. Test of installation can be done by running "python openiam_setup_tests.py" in the "setup" folder. The installation test also runs a test suite to see if the NRAP-Open-IAM has been installed correctly. To run the test suite separately, run "python iam_test.py" in the "test" folder. User's guide: https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/8b27335a-343c-4836-b8a3-3ad0bdc9e669 Developer's guide: https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/3bc6ee7d-609d-4eb6-80ba-fa6130ee0313 Reservoir simulation data used in some examples distributed with NRAP-Open-IAM: - Kimberlina: https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/eb62cece-61b2-4037-9b6d-32407dde2ab8 - Kimberlina (compartmentalized): https://edx.netl.doe.gov/dataset/08f396c8-bc5f-44ad-a028-6e98a6ea6d70/resource/366f9530-3b32-4b84-affe-ab2df1d9a8b5 - FutureGen 2.0: https://edx.netl.doe.gov/dataset/futuregen-2-0-1008-simulation-reservoir-lookup-table NRAP-Open-IAM GitLab repository: https://gitlab.com/NRAP/OpenIAM Related publications: - Bacon, D., Yonkofski, C., Brown, C., Demirkanli, D. and Whiting, J., 2019. Risk-based post injection site care and monitoring for commercial-scale carbon storage: Reevaluation of the FutureGen 2.0 site using NRAP-Open-IAM and DREAM. International Journal of Greenhouse Gas Control 90: 102784. - Bacon, D. Demirkanli, D., and White, S., 2020. Probabilistic risk-based Area of Review (AoR) determination for a deep-saline carbon storage site. International Journal of Greenhouse Gas Control 102: 103153. - Harp, D., Oldenburg, C., and Pawar, R., 2019. A metric for evaluating conformance robustness during geologic CO2 sequestration operations. International Journal of Greenhouse Gas Control 85: 100-108. - Lackey, G., Vasylkivska, V., Huerta, N., King, S., and Dilmore, R., 2019. Managing well leakage risks at a geologic carbon storage site with many wells, International Journal of Greenhouse Gas Control, 88 :182-194. - Vasylkivska, V., Dilmore, R., Lackey, G., Zhang, Y., King, S., Bacon, D., Chen, B., Mansoor, K., and Harp, D., 2021. NRAP-Open-IAM: A flexible open-source integrated assessment model for geologic carbon storage risk assessment and management, Environmental Modelling & Software, 143: 105114. Presentations: - Chen, B., Harp, D., and Pawar, R., A data assimilation approach (ES-MDA) coupling with NRAP-Open-IAM for quantifying uncertainty reduction in geological CO2 sequestration. AGUFM 2019: T44A-02. - Chen, B., and Harp, D., Improving risk analysis precision for geologic CO2 sequestration by quantifying the uncertainty reduction before and after acquiring monitoring data. 14th Greenhouse Gas Control Technologies Conference, Melbourne, Australia, 2018, pp. 21-26. - Harp, D., National Risk Assessment Partnership Task 2: Containment Assurance. No. LA-UR-19-28654, Los Alamos National Laboratory (LANL), Los Alamos, NM (United States), 2019. - Vasylkivska, V., King, S., Bacon, D., Harp, D., Chen, B., Mansoor, K., Onishi, T., Yang, Y., Zhang, Y., and Keating, E., NRAP-Open-IAM: An open-source integrated assessment model, poster, Mastering the Subsurface Through Technology Innovation, Partnerships and Collaboration: Carbon Storage and Oil and Natural Gas Technologies Review Meeting, Pittsburgh, PA, August 13-16, 2018. - Vasylkivska, V., Lackey, G., King, S., Wentworth, A., Huerta, N., Creason, C., DiGiulio, J., Yang, Y., and Dilmore, R., Long-term risk analysis of a geologic CO2 storage project during the post-injection period, SIAM Conference on Computational Science and Engineering, Spokane, WA, February 25-March 1, 2019. - Vasylkivska, V., Overview of the NRAP-Open-IAM tool for carbon storage (beta release), 2019 Annual NRAP Tool Users Meeting, Pittsburgh, PA, August 27, 2019. - Vasylkivska, V., Bacon, D., Chen, B., Dilmore, R., Harp, D., King, S., Lackey, G., Lindner, E., Liu, G., Mansoor, K. and Zhang, Y., NRAP-Open-IAM: A new, open-source code for integrated assessment of geologic carbon storage containment effectiveness and leakage risk, poster, American Geophysical Union Fall Meeting 2020 (virtual meeting), December 2020. - Vasylkivska, V., NRAP open-source integrated assessment model and relevant application, oral presentation, NRAP workshop "NRAP Tools for Geologic Carbon Storage Risk-Based Decision Making" held in conjunction with Groundwater Protection Council (GWPC) 2021 Annual Forum (virtual meeting), Salt Lake City, UT, September 2021. - Vasylkivska, V., NRAP-Open-IAM: open-source integrated assessment model, digital poster/demonstration, software demonstration session, 2022 Carbon Management Project Review Meeting, August 16, 2022

AoR↗

Improving radiograph analysis throughput through transfer learning and object detection

SIGN Fracture Care International partners with surgeons in low-resource hospitals worldwide to provide access to effective orthopedic care by donating educational materials and innovatively designed surgical implants. Over two decades, SIGN’s Online Surgical Database (SOSD) has grown to contain over 500,000 medical images, with radiographs holding the majority share. One challenge in working with hospitals worldwide is that both the radiographs uploaded to the SOSD and the data entry accompanying the uploads vary in quality. To improve the accuracy of data in the SOSD, we trained a model to detect surgical implants in radiographs. We first developed a tool to automatically detect radiographs, then trained an object detection model to determine the number and placement of surgical implants visible in the radiograph. Active learning was used to generate a training set containing 2,510 radiographs with screws, nails, and plates labeled by bounding boxes. Training a model to simultaneously recognize all three classes of implants gave a low average precision (AP) for the plate class, likely due to the low number of plate instances in our training set and the large variety of surgical plates used by SIGN-partnered surgeons. Applying standard image augmentation techniques to increase the plate count in our training set did not appreciably increase the AP of plate detection. To improve plate detection, we redrew the bounding boxes to account for correlations between the screw and plate classes. Training one model to detect nails and screws and a separate model to detect plates increased the AP of plate detection by 78.8 percentage points. The AP of each class was 80.7% for screws, 93.6% for nails, and 92.6% for plates; meanwhile, the sensitivity was 92% for screws, 86% for nails, and 81% for plates. We show that object detection methods can be used to detect surgical implants in radiographs of varying quality; however, the detection ability is dependent on the type of implant, and some implants, in our case plates, must be treated differently than others. Such tools can improve the throughput of radiograph analysis, assisting physicians and surgeons with the treatment of bone fractures.

60 APPLIED LIFE SCIENCES↗

Creation of a Robust and Generalizable Machine Learning Classifier for Patient Ventilator Asynchrony

Background: As healthcare increasingly digitizes, streaming waveform data is being made available from an variety of sources, but there still remains a paucity of performant clinical decision support systems. For example, in the intensive care unit (ICU) existing automated alarm systems typically rely on simple thresholding that result in frequent false positives. Recurrent false positive alerts create distrust of alarm mechanisms that can be directly detrimental to patient health. To improve patient care in the ICU, we need alert systems that are both pervasive, and accurate so as to be informative and trusted by providers. Objective: We aimed to develop a machine learning-based classifier to detect abnormal waveform events using the use case of mechanical ventilation waveform analysis, and the detection of harmful forms of ventilation delivery to patients. We specifically focused on detecting injurious subtypes of patient-ventilator asynchrony (PVA).Methods: Using a dataset of breaths recorded from 35 different patients, we used machine learning to create computational models to automatically detect, and classify two types of injurious PVA, double trigger asynchrony (DTA), breath stacking asynchrony (BSA). We examined the use of synthetic minority over-sampling technique (SMOTE) to overcome class imbalance problems, varied methods for feature selection, and use of ensemble methods to optimize the performance of our model. Results: We created an ensemble classifier that is able to accurately detect DTA at a sensitivity/specificity of 0.960/0.975, BSA at sensitivity/specificity of 0.944/0.987, and non-PVA events at sensitivity/specificity of .967/.980. Conclusions: Our results suggest that it is possible to create a high-performing machine learning-based model for detecting PVA in mechanical ventilator waveform data in spite of both intra-patient, and inter-patient variability in waveform patterns, and the presence of clinical artifacts like cough and suction procedures. Our work highlights the importance of addressing class imbalance in clinical data sets, and the combined use of statistical methods and expert knowledge in feature selection.

97 MATHEMATICS AND COMPUTING↗

MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring

Development and evaluation of Intensive Care Unit (ICU) decision-support systems would be greatly facilitated by the availability of a large-scale ICU patient database. Following our previous efforts with the MIMIC (Multi-parameter Intelligent Monitoring for Intensive Care) Database, we have leveraged advances in networking and storage technologies to develop a far more massive temporal database, MIMIC II. MIMIC II is an ongoing effort: data is continuously and prospectively archived from all ICU patients in our hospital. MIMIC II now consists of over 800 ICU patient records including over 120 gigabytes of data and is growing. A customized archiving system was used to store continuously up to four waveforms and 30 different parameters from ICU patient monitors. An integrated user-friendly relational database was developed for browsing of patients' clinical information (lab results, fluid balance, medications, nurses' progress notes). Based upon its unprecedented size and scope, MIMIC II will prove to be an important resource for intelligent patient monitoring research, and will support efforts in medical data mining and knowledge-discovery.

NASA Discipline Cardiopulmonary↗

NASA spinoffs to bioengineering and medicine

Through the active transfer of technology, the National Aeronautics and Space Administration (NASA) Technology Utilization (TU) Program assists private companies, associations, and government agencies to make effective use of NASA's technological resources to improve U.S. economic competitiveness and to provide societal benefit. Aerospace technology from areas such as digital image processing, space medicine and biology, microelectronics, optics and electrooptics, and ultrasonic imaging have found many secondary applications in medicine. Examples of technology spinoffs are briefly discussed to illustrate the benefits realized through adaptation of aerospace technology to solve health care problems. Successful implementation of new technologies increasingly requires the collaboration of industry, universities, and government, and the TU Program serves as the liaison to establish such collaborations with NASA. NASA technology is an important resource to support the development of new medical products and techniques that will further advance the quality of health care available in the U.S. and worldwide.

Biomedical Engineering/instrumentation/trends↗

Johnson Space Center Astronaut and Flight Surgeon Survey Report (January 2008)

In early 2007, an incident involving former astronaut, Lisa Nowak, led NASA to conduct several reviews including internal and external evaluations of astronaut behavioral health and medical care. The internal NASA review, led by Johnson Space Center (JSC), focused on two elements: 1) current astronaut behavioral medicine practices and 2) a review of relevant records and information to determine whether any leading indicators that could have averted the incident were missed. The external review, conducted by the NASA Astronaut Health Care System Review Committee (comprised of external experts from the behavioral health and aerospace medical communities), focused on space medicine operations at JSC.

Johnson Space Center(JSC)↗

Giant Apparent Optical Circular Dichroism in Thin Films of Bismuth-Based Hybrid Organic-Inorganic Metal Halide Semiconductor Through Preferred Orientation

Introducing chirality into organic/inorganic hybrid materials can impart chiroptical properties such as circular dichroism. The ability to tune chiroptical properties in self-assembled materials can have important implications for spintronic and optoelectronic applications. Here, a chiral organic cation, (R/S)-4-methoxy-a-methylbenzylammonium, is incorporated to synthesize the bismuth-based hybrid organic-inorganic metal halide semiconductor, (R/S-MeOMePMA)BiI4. Thin films of this Bi-based compound demonstrate large chiroptical responses, with circular dichroism anisotropy (gCD) values up to ˜0.1, close to the highest value observed in another chiral metal-halide semiconductor, (R-MBA2CuCl4). Detailed investigation reveals that this large gCD in (R/S-MeOMePMA)BiI4 is caused by the apparent CD effect. Careful selection of deposition conditions and the concomitant thin-film orientation enables the control of gCD, with maximum value observed when its thin film has a well-crystallized preferred (001) orientation parallel to the substrate. The results support a growing body of evidence that low symmetry plays an important role in achieving unusually large gCD in these chiral metal-halide materials and provides design rules for achieving large chiroptical response via morphology control.

chiroptic response↗

Interphases in Sodium-Ion Batteries

Sodium-ion batteries (SIBs) as economical high energy alternatives to lithium-ion batteries (LIBs) have received significant attention for large-scale energy storage in the last few years. While the efforts of developing SIBs have benefited from the knowledge learned in LIBs, thanks to the apparent proximity between Na-ion and Li-ion, the unique physical and chemical properties of Na-ion also distinctly differ itself from Li-ion. It is expected SIBs have drastically different electrode material structure, solvation-de-solvation behavior, electrode-electrolyte interphase stability, ion transfer property, and hence electrochemical performance of batteries. In this review, we comprehensively summarize the current understanding of the anode solid-electrolyte-interphase (SEI) and cathode cathode-electrolyte-interphase (CEI) in SIBs, with an emphasis on how the tuning of the stability and ion transfer properties of interphases fundamentally determines the reversibility and efficiency of electrochemical reactions. Through these carefully screened references, we intend to reveal the intrinsic correlation between the properties/functionalities of the interphases and the electrochemical performances of batteries.

Song, Junhua↗

On‐site surrogates for large‐scale calibration

Abstract Motivated by a computer model calibration problem from the oil and gas industry, involving the design of a honeycomb seal, we develop a new Bayesian methodology to cope with limitations in the canonical apparatus stemming from several factors. We propose a new strategy of on‐site design and surrogate modeling for a computer simulator acting on a high‐dimensional input space that, although relatively speedy, is prone to numerical instabilities, missing data, and nonstationary dynamics. Our aim is to strike a balance between data‐faithful modeling and computational tractability in a calibration framework—tailoring the computer model to a limited field experiment. Situating our on‐site surrogates within the canonical calibration apparatus requires updates to that framework. We describe a novel yet intuitive Bayesian setup that carefully decomposes otherwise prohibitively large matrices by exploiting the sparse blockwise structure. Empirical illustrations demonstrate that this approach performs well on toy data and our motivating honeycomb example.

Huang, Jiangeng↗

Enhancing 2‐Pyrone Synthase Efficiency by High‐Throughput Mass‐Spectrometric Quantification and In Vitro/In Vivo Catalytic Performance Correlation

Abstract Engineering efficient biocatalysts is essential for metabolic engineering to produce valuable bioproducts from renewable resources. However, due to the complexity of cellular metabolic networks, it is challenging to translate success in vitro into high performance in cells. To meet such a challenge, an accurate and efficient quantification method is necessary to screen a large set of mutants from complex cell culture and a careful correlation between the catalysis parameters in vitro and performance in cells is required. In this study, we employed a mass‐spectrometry based high‐throughput quantitative method to screen new mutants of 2‐pyrone synthase (2PS) for triacetic acid lactone (TAL) biosynthesis through directed evolution in E. coli . From the process, we discovered two mutants with the highest improvement (46 fold) in titer and the fastest k cat (44 fold) over the wild type 2PS, respectively, among those reported in the literature. A careful examination of the correlation between intracellular substrate concentration, Michaelis‐Menten parameters and TAL titer for these two mutants reveals that a fast reaction rate under limiting intracellular substrate concentrations is important for in‐cell biocatalysis. Such properties can be tuned by protein engineering and synthetic biology to adopt these engineered proteins for the maximum activities in different intracellular environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗