Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

An Analysis of PNM's Renewable Reserve Requirements to Meet New Mexico's Decarbonization Goals

Over the next three years, the Public Service Company of New Mexico (PNM) plans to increase utility-scale solar photovoltaic (PV) capacity from today’s roughly 330MW to about 1600MW. This massive increase in variable generation—from about 15% to 75% of peak load—will require changes in how PNM operates their system. We characterize the 5 and 30-minute solar and wind forecast errors that the system is likely to experience in order to determine the level of reserves needed to counteract such events. Our focus in this study is on negative forecast error (in other words, shortfalls relative to forecast) – whereas excess variable generation can be curtailed if needed, a shortfall must be compensated for to avoid loss of load. Calculating forecast error requires the use of the same forecasting methods that PNM uses or a reasonable approximation thereof. For wind, we use a persistence forecast on actual 5-minute 2019 wind output data (scaled up to reflect the amount of wind capacity planned for 2025). For solar, we use a formula incorporating the clear sky index (CSI) for the forecast. As the solar on the grid now is a small fraction of what is planned for 2025, we generated 5-minute solar data using 2019 weather inputs. We find that to handle 99.9% of the 5-minute negative forecast errors, a maximum of 275MW of variable generation reserve during daylight hours, and a maximum of 75MW during non-daylight hours, should be sufficient. Note that this variable generation reserve is an additional reserve category that specifies reserves over and above what are currently carried for contingency reserve. This would require a significant increase in reserve relative to what PNM currently carries or can call upon from other utilities per reserve sharing agreements. This variable generation reserve specification may overestimate the actual level needed to deal with PNM’s planned variable generation in 2025. The forecasting methodologies used in this study likely underperform PNM’s forecasting – and better forecasting allows for less reserve. To obtain more precise estimates, it is necessary to consider load and use the same forecasting inputs and methods used by PNM.

14 SOLAR ENERGY↗

An overview of the issues: physiological effects of bed rest and restricted physical activity

Reduction of exercise capacity with confinement to bed rest is well recognized. Underlying physiological mechanisms include dramatic reductions in maximal stroke volume, cardiac output, and oxygen uptake. However, bed rest by itself does not appear to contribute to cardiac dysfunction. Increased muscle fatigue is associated with reduced muscle blood flow, red cell volume, capillarization and oxidative enzymes. Loss of muscle mass and bone density may be reflected by reduced muscle strength and higher risk for injury to bones and joints. The resultant deconditioning caused by bed rest can be independent of the primary disease and physically debilitating in patients who attempt to reambulate to normal active living and working. A challenge to clinicians and health care specialists has been the identification of appropriate and effective methods to restore physical capacity of patients during or after restricted physical activity associated with prolonged bed rest. The examination of physiological responses to bed rest deconditioning and exercise training in healthy subjects has provided significant information to develop effective rehabilitation treatments. The successful application of acute exercise to enhance orthostatic stability, daily endurance exercise to maintain aerobic capacity, or specific resistance exercises to maintain musculoskeletal integrity rather than the use of surgical, pharmacological, and other medical treatments for clinical conditions has been enhanced by investigation and understanding of underlying mechanisms that distinguish physical deconditioning from the disease. This symposium presents an overview of cardiovascular and musculoskeletal deconditioning associated with reduced physical work capacity following prolonged bed rest and exercise training regimens that have proven successful in ameliorating or reversing these adverse effects.

NASA Program Space Physiology and Countermeasures↗

Revealing the aging process of solid electrolyte interphase on SiOx anode

Abstract As one of the most promising alternatives to graphite negative electrodes, silicon oxide (SiO x ) has been hindered by its fast capacity fading. Solid electrolyte interphase (SEI) aging on silicon SiO x has been recognized as the most critical yet least understood facet. Herein, leveraging 3D focused ion beam-scanning electron microscopy (FIB-SEM) tomographic imaging, we reveal an exceptionally characteristic SEI microstructure with an incompact inner region and a dense outer region, which overturns the prevailing belief that SEIs are homogeneous structure and reveals the SEI evolution process. Through combining nanoprobe and electron energy loss spectroscopy (EELS), it is also discovered that the electronic conductivity of thick SEI relies on the percolation network within composed of conductive agents (e.g., carbon black particles), which are embedded into the SEI upon its growth. Therefore, the free growth of SEI will gradually attenuate this electron percolation network, thereby causing capacity decay of SiO x . Based on these findings, a proof-of-concept strategy is adopted to mechanically restrict the SEI growth via applying a confining layer on top of the electrode. Through shedding light on the fundamental understanding of SEI aging for SiO x anodes, this work could potentially inspire viable improving strategies in the future.

25 ENERGY STORAGE↗

Bulk Grid Frequency Support Using Electrolyzers

Increasing renewable penetration in the bulk power systems has resulted in declining inertial response of the generation during system disturbances. This results in larger frequency deviations and oscillations during such events. This paper proposes a strategy for controlled dispatch of electrolyzers as loads to improve the system’s frequency response. A droop based controller with constraints based on electrolyzer operating limits has been developed to regulate its load. Consecutively, a localized frequency based control strategy has been developed to support the bulk system during disturbances. The impact of the electrolyzer support has been demonstrated using the 23-bus SAVNW system, and the 240-bus WECC system for baseline, 25% and 50% renewable penetration. The impact of changing droop settings and the available controllable electrolyzer capacities on the system’s frequency response has also been presented. Overall, the dispatchable electrolyzers helps improve (reduce) both the maximum frequency deviation and the settling times during common disturbances like loss of load/generation, and line faults. Systems with lower inertia were seen to benefit more from the controlled electrolyzer dispatch.

39 EE - Hydrogen and Fuel Cell Technologies (EE-3F↗

Electrical power requirements analysis. Single failure tolerant entry

The results of an analysis of the orbiter electrical power system for the case of a single failure tolerant (SFT) entry are presented. The analysis was performed using the shuttle electrical power system analysis computer program. It was performed to permit assessment of the capability of the orbiter systems to support the proposed entry configuration and to provide the data necessary to identify potential constraints and limitations. Three contingency modes have been identified which would require an SFT entry. This analysis addresses an SFT entry resulting from the loss of two fuel cell powerplants, while on orbit. The results of the analysis indicate that, even under near optimum conditions, the fuel cell power demand will exceed the tested operating capacity of 16 kw, and that various electrical components may experience voltages below 24 VDC.

Pipher, M. D.↗

NECAP 4.1: NASA's Energy-Cost Analysis Program fast input manual and example

NASA's Energy-Cost Analysis Program (NECAP) is a powerful computerized method to determine and to minimize building energy consumption. The program calculates hourly heat gain or losses taking into account the building thermal resistance and mass, using hourly weather and a response factor method. Internal temperatures are allowed to vary in accordance with thermostat settings and equipment capacity. NECAP 4.1 has a simplified input procedure and numerous other technical improvements. A very short input method is provided. It is limited to a single zone building. The user must still describe the building's outside geometry and select the type of system to be used.

Jensen, R. N.↗

NECAP 4.1: NASA's energy-cost analysis program user's manual

The Enery Cost Analysis Program (NECAP) is a powerful computerized method to determine and to minimize building energy consumption. The program calculates hourly heat gain or losses taking into account the building thermal resistance and mass, using hourly weather and a "response factor' method. Internal temperatures are allowed to vary in accordance with thermostat settings and equipment capacity. A simplified input procedure and numerous other technical improvements are presented. This Users Manual describes the program and provides examples.

Jensen, R. N.↗

Analysis of a Radioisotope Thermal Rocket Engine

The Triton Hopper is a concept for a global hopper vehicle which uses a radioisotope rocket engine and In-situ propellant acquisition to explore the surface of Neptune's moon, Triton. The current Triton Hopper concept stores heated Nitrogen in a spherical tank to be used as the propellant. The aim of the research was to investigate the benefits of storing propellant at ambient temperature and heating it through the use of a thermal block during engine operation, as opposed to storing gas at a high temperature. Lithium, Lithium Fluoride and Beryllium were considered as possible materials for the thermal block. A heat energy analysis indicated that a lithium thermal mass would provide the highest heat energy for a temperature change from 900 Celsius to -100 Celsius. A heat transfer analysis was performed for Nitrogen at -100 Celsius flowing through 1000 passages inside a 1kg lithium thermal block at a temperature of 900 Celsius. The system was analyzed as turbulent flow through a tube with constant surface temperature. The analysis indicated that the propellant reached a maximum temperature of 877 Celsius before entering the nozzle. At this exit temperature, the average specific impulse [I(sub sp)] of the engine was determined to be 157s. Previous studies for the stored heated gas concept suggest that the engine would have an average I(sub sp) of approximately 52s. Thus, the use of a thermal block concept results in a 200 percent engine performance increase. In addition, a tank sizing study was performed to determine if the concept is feasible in terms of mass requirements. The mass for a spherical carbon fiber COPV storing 35kg of nitrogen at an initial temperature of -100 Celsius and a pressure of 1000psia, was determined to be 7.2kg. The specific impulse analysis indicated that the maximum engine performance is obtained for a mass ratio of 5kg of Nitrogen per every 1kg of lithium thermal mass. Thus for 35kg of Nitrogen the total thermal mass would be 7kg. This brings the total mass of the system to 49.2.kg which is less than the 56kg landing payload capacity of the Triton Hopper. Finally, an insulation analysis using 10mm of MLI insulation indicated that a total of 22 watts of heat are lost to the environment. With the heat loss known, the power required to heat the thermal mass to 900 Celsius in 24 days was determined to be 2.15 watts. The study's results allowed us to conclude that the thermal mass concept is the better option due to the performance increase provided, the low power requirement and its compliance with the landing mass requirement of the Triton Hopper.

Radioisotope↗

Investigating the Chemical Reactivity of Lithium Silicate Model SEI Layers

Silicon anodes suffer from an unstable solid electrolyte interphase (SEI) layer that contributes to undesirable capacity fade with cycling. A key part to addressing this unstable SEI formation is to examine how certain components of the SEI react with the electrolyte over time. One SEI component that has not been thoroughly studied in the context of the chemical reactivity against the electrolyte is lithiated silicate. Four model silicate thin films with increasing lithium content were deposited by radio frequency (RF) magnetron sputtering to study how the lithiation of the native oxide on a silicon anode affects the chemical stability of the anode surface. SiO2, Li2Si2O5, Li2SiO3, and Li3SiOx films were exposed to 1.2 M LiPF6 in the 3:7 wt% ethylene carbonate/ethyl methyl carbonate (EC/EMC) electrolyte for periods of time that are representative of the amount of time it takes to undergo cell formations. Soaked samples were rinsed, dried, and characterized by a combination of attenuated total reflectance-infrared spectroscopy (ATR-IR), focused ion beam-secondary electron microscopy (FIB-SEM), and X-ray photoelectron spectroscopy (XPS) depth profiling. It was found that the rate of the decrease in film thickness of the silicates exposed to the electrolyte over time increases as a function of the lithium content in the thin film. This reaction involves HF etching and LiPF6 salt degradation leading to silicate loss and fluorination throughout the bulk. Understanding this chemical instability is critical to determining the overall mechanism of SEI degradation over time.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Direct Imaging of the Structural and Morphological Evolution of Epitaxial LiCoO 2 Films during Charge and Overcharge

The capacity decay of layered cathodes in high-voltage applications underscores the need to utilize accurate and precise techniques to understand the underlying mechanisms. Here, we use well-defined epitaxial LiCoO 2 (LCO) films on SrRuO 3 /SrTiO 3 (SRO/STO) with controlled orientations and defect structures along with in situ electrochemical atomic force microscopy to probe the structural and morphological evolutions during the charge and overcharge processes. We quantitatively show the morphological changes in both the reversible delithiation regime and the irreversible over-delithiation regime and correlate the overall electrochemical behaviors to atomic scale defect evolutions in the films. Further, we also observe a significantly lower charging capacity for LCO/SRO/STO(111) compared to that of LCO/SRO/STO(001) films of the same thickness, which is ascribed to different types of atomic scale defects formed during the film growth process. Our high- resolution scanning transmission electron microscopy (STEM) and electron energy loss spectroscopy (EELS) studies reveal that the antiphase boundaries in LCO/SRO/STO(111) act as viable channels for Li migration but are more susceptible to irreversible phase transitions, which then block subsequent Li diffusion. The failure mechanisms developed here may provide insight into the design of future cathode materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Throughput Measurements and Capacity Estimates for Quantum Connections

The throughput of conventional and quantum network connections is an important performance metric, which is typically specified by bits per second (bps) and entangled quntum bits per second (ebps), respectively. It is measured over practical quantum network connections using specialized methods, and estimated using analytical bounds for which extensive theory has been developed. For practical connections, however, these two quantities have often been hard to correlate due to the lack of measurements and estimates derived under well-characterized common conditions. They both differ significantly from the conventional network throughput of TCP which employs buffers and loss recovery mechanisms. We describe a conventional-quantum testbed that enables the comparison of these two quantities both qualitatively and quantitatively. The bps and ebps throughput is measured over fiber connections of lengths over 75 kilometers, which show that the former decreases significantly slower with distance than the latter and in a qualitatively different way. The analytic capacity estimates of ebps are derived using approximations based on light intensity measurements, and they decrease more rapidly with distance than the measured ebps throughput. These results provide qualitative insights into the conventional transport mechanisms based on buffers, and the conditions used in deriving the analytical ebps capacity estimates.

Rao, Nageswara↗

Stabilizing the Interphase in Cobalt–Free, Ultrahigh–Nickel Cathodes for Lithium–Ion Batteries

High-nickel layered oxide cathodes, such as LiNi 1-x-y Mn x Co y O 2 (NMC) and LiNi 1-x-y Co x Al y O 2 (NCA), are at the forefront for implementation in high-energy-density lithium-ion batteries. The presence of cobalt in both cathode chemistries, however, largely deters their application due to fiscal and humanitarian issues affiliated with cobalt sourcing. Increasing the Ni content drives down the Co content, but introduces additional structural and electrochemical problems attributed to high-Ni cathodes. Herein a dually modified cobalt-free ultrahigh-nickel cathode 0.02B-LiNi 0.99 Mg 0.01 O 2 (NBM) is presented with 1 mol% Mg and 2 mol% B that exhibits a high initial 1C discharge capacity of 210 mA h g –1 with a 20% capacity retention improvement over 500 cycles when benchmarked against LiNiO 2 (LNO) in pouch full cell configurations with graphite anode. Postmortem analyses reveal the enhanced performance stems from reduced active lithium inventory loss and localized surface reactivity in the NBM cathode. Here, the stabilized cathode-electrolyte interphase subsequently reduces transition-metal dissolution and ensuing chemical crossover to the graphite anode, which prevents further catalyzed parasitic reactions that harmfully passivate the anode surface. Altogether, this study aims to highlight the importance of electrode characterization and analysis from an interphasial viewpoint and to push the ongoing research to stabilize cobalt-free ultrahigh-Ni cathodes for industrial feasibility.

25 ENERGY STORAGE↗

A High Energy–Density, Cobalt–Free, Low–Nickel LiNi 0.7 Mn 0.25 Al 0.05 O 2 Cathode with a High–Voltage Electrolyte for Lithium–Metal Batteries

Cobalt-free cathode materials have garnered increased attention for applications in next-generation batteries for electric vehicles, as cobalt is considered to have at a high supply chain risk. Here, the use of a localized saturated electrolyte (LSE) to enable stable cycling of a cobalt-free, low-nickel layered-oxide cathode LiNi 0.7 Mn 0.25 Al 0.05 O 2 (NMA-70) to higher voltages (4.6 V) in a lithium-metal battery is demonstrated. Compared to the baseline LP57 electrolyte, the LSE extends the cycle life from ≈100 cycles to ≈400 cycles before reaching 80% capacity retention. Visual indicators of cell degradation, such as product deposition, are observed on electrodes cycled in LP57. It is shown that cycling NMA-70 in LSE reduces the overall active material loss and overpotential growth during extended cycling. This is attributed to the formation of a beneficial fluorinated interphase layer, a lower degree of rock-salt phase formation, and a reduction in the gas evolution from the cathode surface. The decrease in gas evolution from the cathode cycled in LSE reflects a lower degree of electrolyte reactivity and an overall improvement in the safety characteristics of the cell. Furthermore, this study highlights the importance of a stable electrolyte to enable the high-voltage cycling of alternative, lower nickel, and cobalt-free cathodes.

25 ENERGY STORAGE↗

An Analysis of Post Attack Impacts and Effects of Learning Parameters on Vulnerability Assessment of Power Grid

Due to the increasing number of heterogeneous devices connected to electric power grid, the attack surface increases the threat actors. Game theory and machine learning are being used to study the power system failures caused by external manipulation. Most of existing works in the literature focus on one-shot process of attacks and fail to show the dynamic evolution of the defense strategy. In this paper, we focus on an adversarial multistage sequential game between the adversaries of the smart electric power transmission and distribution system. We study the impact of exploration rate and convergence of the attack strategies (sequences of action that creates large scale blackout based on the system capacity) based on the reinforcement learning approach. We also illustrate how the learned attack actions disrupt the normal operation of the grid by creating transmission line outages, bus voltage violations, and generation loss. This simulation studies are conducted on IEEE 9 and 39 bus systems. The results show the improvement of the defense strategy through the learning process. The results also prove the feasibility of the learned attack actions by replicating the disturbances created in simulated power system.

attack impacts↗

Niobium-tin as a transformative technology for low-beta linacs

Niobium-tin has been identified as the most promising next-generation superconducting material for accelerator cavities. This is due to the higher critical temperature (Tc = 18 K) of Nb3Sn compared to niobium (TC = 9.2 K), which leads to greatly reduced RF losses in the cavity during 4.5 K operation. This allows two important changes during cavity and cryomodule design. First, the higher Tc leads to negligible BCS losses when operated at 4.5 K, which allows for a higher frequency to be used, translating to significantly smaller cavities and cryomodules. Second, the reduced dissipated power lowers the required cryogenic cooling capacity, meaning that cavities can feasibly be operated on 5-10 W cryocoolers instead of a centralized helium refrigeration plant. These plants and distribution systems are costly and complex, requiring skilled technicians for operation and maintenance. These fundamental changes present an opportunity for a paradigm shift in how low-beta linacs are designed and operated. Fabrication challenges and first coated cavity test results are discussed.

43 PARTICLE ACCELERATORS↗

Modeling Needs to Support the Reconstruction Strategy of Ukraine

Ukraine has been facing difficult times. Russia started a full-scale invasion on February 24, 2022, and has caused huge human and infrastructure losses. As a result of the invasion, more than 8 million people left their homes. The Russian army has targeted Ukrainian energy sources, destroying or damaging over 50% of thermal power generation capacity (coal and gas), 30% of solar generation, and 90% of wind generation. The Russians are also threatening Ukrainian energy security, as they currently control the Zaporizhzhia nuclear power plant – Europe’s largest. In addition, Russia has destroyed 121,000 buildings, including 5,300 multistory buildings - more buildings than Ukraine built during the past five years. The occupiers destroyed or damaged 343 district heat boiler stations (destroyed 12 / damaged 331) and 8 CHPs (destroyed 4/ damaged 4). There is no doubt that Ukraine will be able to protect its sovereignty and restore its territorial integrity; however, this will be a long process. The Government of Ukraine needs to simultaneously focus on many issues, from waging war to the restoration of electricity, water, and heat supply in the territories close to the front line. In addition to these time-sensitive issues, the government also needs to plan a long term multi-sector strategy for the reconstruction of Ukraine’s economy. Ukraine initiated a broad-based political process for recovery at the International Ukraine Recovery Conference (URC 2022) in Lugano, Switzerland. Prior to URC 2022, Ukraine applied for EU membership on February 28 and was granted the status of candidate country by the European Council on June 23, 2022. More than 40 nations are fully committed to supporting Ukraine throughout its path from early to long-term recovery. In addition, these countries link a successful recovery to Ukraine’s European future (URC, 2022a). The reconstruction process will be long. The government also recognizes that it is not enough to build energy infrastructure back – it should be built back better. The government is committed to building a more sustainable and cleaner energy sector. Energy modeling can provide important insights into paths to decarbonize Ukraine’s economy while rebuilding it after the war. Pacific Northwest National Laboratory (PNNL) and the Institute for Economics and Forecasting of the National Academy of Sciences of Ukraine (IEF) work on modeling decarbonization scenarios in the energy sector of Ukraine. The teams focus on the heat sector, which includes district heat, autonomous and individual heating, and energy consumption by final energy consumption sectors, including buildings. Since the teams use world-class integrated assessment models, other sectors will be analyzed as well. The purpose of the document is to describe the needs of key Ukrainian ministries in modeling the reconstruction process. The scope of this document is limited to modeling energy consumption by the power and heat sectors, final energy consumption by buildings, and GHG emissions from these two sectors. The rest of this policy memo is organized as follows. After this introduction, Chapter 2 discusses key provisions of the reconstruction strategy with a focus on energy, buildings, heat supply, environment, and European integration aspirations. Section 3 provides an overview of recent developments and key decisions of the Government of Ukraine in the area of energy efficiency and decarbonization. Finally, Section 4 provides key suggestions on how PNNL and IEF can help the Government of Ukraine in developing strategic documents.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High Performance Solvent for NGCC Flue Gas CO 2 Capture (Final Technical Report)

Amine-based solvent absorption is the most mature and reliable technology for large scale CO 2 capture, dating back to the 1930s when monoethanolamine (MEA) was used to treat acid gases from oil refineries. However, while strategic advancements have optimized the CO2 capture process, the cost of capture remains high, where current estimates suggest that CO 2 capture costs are around $\$$72/tonne of CO 2 . To address this, solvent development and optimization have become a focus of current research. This project sought to develop a high-performance solvent to reduce the overall cost of CO 2 capture from NGCC flue gas. Here, solvent optimization focused on: (1) reducing the energy required for CO 2 desorption in a reboiler, (2) improving CO 2 absorption and desorption reaction kinetics, (3) improving solvent stability, and (4) reducing environmental impacts. Susteon has developed and evaluated a promoted solvent, Sustenol™, for NGCC flue gas CO 2 capture. The optimized Sustenol™ also shows a higher dynamic CO 2 absorption capacity of ~0.5 mol CO2 /mol amine compared to 0.25 mol CO2 /mol amine for 30 wt% MEA. Additionally, the solvent is oxidatively, thermally and hydrothermally stable, which leads to lower solvent loss and emissions. These advancements have resulted in a solvent regeneration energy of 2.16 GJ/tonne of CO 2 which is >30% lower than current state-of-the-art commercial and emerging solvents. Combined with empirical data from the bench and pilot scale testing, this preliminary TEA study indicated the cost of CO 2 capture by Sustenol™ for 97% CO 2 removal at $\$$54/tonne and for 90% removal at $\$$49/tonne, with a pathway to achieve $\$$45/tonne of CO 2 with continued process and solvent advancements. Susteon has developed a technology roadmap to reduce the cost of CO 2 capture to <$\$$45/tonne for NGCC flue gas. Susteon plans to derisk this technology for commercial deployment through comprehensive solvent degradation testing, long-term testing in a pilot plant at 5 tonne CO2 /day and demonstration scale testing at 100 tonne CO2 /day with NGCC flue gas and engineering design studies to qualify Sustenol™ as a drop-in replacement solvent.

03 NATURAL GAS↗

High temperature underground thermal energy storage system for solar energy

The activities feasibility of high temperature underground thermal storage of energy was investigated. Results indicate that salt cavern storage of hot oil is both technically and economically feasible as a method of storing huge quantities of heat at relatively low cost. One particular system identified utilizes a gravel filled cavern leached within a salt dome. Thermal losses are shown to be less than one percent of cyclically transferred heat. A system like this having a 40 MW sub t transfer rate capability and over eight hours of storage capacity is shown to cost about $13.50 per KWh sub t.

Collins, R. E.↗