How Building America Research is Removing Major Roadblocks to High-Performance Homes

Today the U.S. housing industry is critically challenged to deliver homes that safely and effectively meet demanding new performance requirements of homeowners and modern building codes. But the housing industry must learn to better manage real and perceived risks that can impact occupant health, comfort, and building durability. It is clear from decades of applied research through the U.S. Department of Energy's (DOE) Building America program that many building energy efficiency and performance improvements will not be adopted by the market or industry standards if the costs and perceived risks of change outweigh the known benefits, especially when the benefits do not accrue directly to businesses who must take those risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SAD5 Stereo Correlation Line-Striping in an FPGA

High precision SAD5 stereo computations can be performed in an FPGA (field-programmable gate array) at much higher speeds than possible in a conventional CPU (central processing unit), but this uses large amounts of FPGA resources that scale with image size. Of the two key resources in an FPGA, Slices and BRAM (block RAM), Slices scale linearly in the new algorithm with image size, and BRAM scales quadratically with image size. An approach was developed to trade latency for BRAM by sub-windowing the image vertically into overlapping strips and stitching the outputs together to create a single continuous disparity output. In stereo, the general rule of thumb is that the disparity search range must be 1/10 the image size. In the new algorithm, BRAM usage scales linearly with disparity search range and scales again linearly with line width. So a doubling of image size, say from 640 to 1,280, would in the previous design be an effective 4 of BRAM usage: 2 for line width, 2 again for disparity search range. The minimum strip size is twice the search range, and will produce an output strip width equal to the disparity search range. So assuming a disparity search range of 1/10 image width, 10 sequential runs of the minimum strip size would produce a full output image. This approach allowed the innovators to fit 1280 960 wide SAD5 stereo disparity in less than 80 BRAM, 52k Slices on a Virtex 5LX330T, 25% and 24% of resources, respectively. Using a 100-MHz clock, this build would perform stereo at 39 Hz. Of particular interest to JPL is that there is a flight qualified version of the Virtex 5: this could produce stereo results even for very large image sizes at 3 orders of magnitude faster than could be computed on the PowerPC 750 flight computer. The work covered in the report allows the stereo algorithm to run on much larger images than before, and using much less BRAM. This opens up choices for a smaller flight FPGA (which saves power and space), or for other algorithms in addition to SAD5 to be run on the same FPGA.

Villalpando, Carlos Y.↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Evaluation of Passive Vents in New Construction Multifamily Buildings

Exhaust ventilation and corresponding outdoor air strategies are being implemented in high-performance new construction multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards. CARB's 2014 'Evaluation of Ventilation Strategies in New Construction Multifamily Buildings' consistently demonstrated that commonly used outdoor air strategies are not performing as expected. Of the four strategies evaluated in 2014, the exhaust ventilation system that relied on outdoor air from a pressurized corridor was ruled out as a potential best practice due to its conflict with meeting requirements within most fire codes. Outdoor air that is ducted directly to the apartments was a strategy determined to have the highest likelihood of success, but with higher first costs and operating costs. Outdoor air through space conditioning systems was also determined to have good performance potential, with proper design and execution. The fourth strategy, passive systems, was identified as the least expensive option for providing outdoor air directly to apartments, with respect to both first costs and operating costs. However, little is known about how they actually perform in real-world conditions or how to implement them effectively. Based on the lack of data available on the performance of these low-cost systems and their frequent use in the high-performance building programs that require a provision for outdoor air, this research project sought to further evaluate the performance of passive vents.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Synthesis of Multigraft Copolymer Thermoplastic Elastomers: Superelastomers

Thermoplastic elastomers (TPEs) have been widely studied because of their recyclability, good processibility, low production cost, and unique performance. The building of graft-type architectures can greatly improve mechanical properties of TPEs. This review focuses on the advances in different approaches to synthesize multigraft copolymer TPEs. Anionic polymerization techniques allow for the synthesis of well-defined macromolecular structures and compositions, with great control over the molecular weight, polydispersity, branch spacing, number of branch points, and branch point functionality. Progress in emulsion polymerization offers potential approaches to commercialize these types of materials with low production cost via simple operations. Moreover, the use of multigraft architecturesprovides a solution to the limited elongational properties of all-acrylic TPEs, which can greatly expand their potential application range. The combination of different polymerization techniques, the introduction of new chemical compositions, and the incorporation of sustainable sources are expected to be further investigated in this area in coming years.

36 MATERIALS SCIENCE↗

The Phenix‐AlphaFold webservice: Enabling AlphaFold predictions for use in Phenix

Abstract Advances in machine learning have enabled sufficiently accurate predictions of protein structure to be used in macromolecular structure determination with crystallography and cryo‐electron microscopy data. The Phenix software suite has AlphaFold predictions integrated into an automated pipeline that can start with an amino acid sequence and data, and automatically perform model‐building and refinement to return a protein model fitted into the data. Due to the steep technical requirements of running AlphaFold efficiently, we have implemented a Phenix‐AlphaFold webservice that enables all Phenix users to run AlphaFold predictions remotely from the Phenix GUI starting with the official 1.21 release. This webservice will be improved based on how it is used by the research community and the future research directions for Phenix.

Poon, Billy K.↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]↗

Microstructure, fatigue, and impact toughness properties of additively manufactured nickel alloy 718

A complete understanding of processing-structure-property-performance relationship of additively manufactured (AM) components are critical from an application standpoint. Therefore, in the current investigation, a comprehensive microstructural characterization and mechanical properties (tensile, fatigue and impact toughness) evaluation of nickel alloy 718 AM by the laser powder bed fusion (L-PBF) technique have been performed. AM builds were made from powders manufactured via different atomization conditions. Although the standard post-heat treatment procedure led to the removal of severe interdendritic segregation both grain boundary and intra-grain precipitation of d phase occurred. Regardless of d phase presence, axial fatigue properties of both the AM builds were similar to design handbook wrought fatigue data. However, due to the d phase, impact toughness properties were comparable to the wrought material conditions that exhibited d phase. Fractured surfaces of Charpy impact samples exhibited crack propagation extensively along the boundaries decorated by d precipitates.

Komarasamy, Mageshwari↗

A framework for estimating the energy-saving potential of occupant behaviour improvement

Energy-related occupant behaviour in buildings has demonstrated considerable energy-saving potential. However, the current modelling method of occupant behaviour does not give sufficient considerations on the implementation difficulty of behaviour and provide a holistic map from survey data to various behaviour models. This article proposes a holistic survey-and-simulation-based framework for estimating the energy-saving potential of occupant behaviour improvement. In the framework, seven typical categories of occupant behaviour models are identified based on the survey results. According to the implementation difficulty, the models are integrated into four behaviour styles (baseline, wasteful, moderate and austere) to represent different levels of energy-saving consciousness of occupants. Based on a case study with a nationwide survey in Singapore, there are remarkable energy savings potential if occupant behaviour is improved; the building energy consumption can be reduced by up to 9.5% with the moderate behaviour improvement, and up to 21.0% with the aggressive behaviour improvement. The simulation results accord well with the measured results within a reasonable range of deviation. The framework can be applied to estimate the energy-saving potential of occupant behaviour improvement in a building with affordable cost, and the findings can inform a behaviour improvement programme with effective and efficient measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mapping use cases and dataset needs for benchmarking buildings data

A perennial challenge in buildings research is the lack of high-quality datasets that can be relied upon for a wide array of tasks, including model calibration and improving energy efficiency and load flexibility. Instrumenting a building for data collection is resource intensive, so it is important to be methodical in the approach and ensure that resulting data are flexible and useful for a broad range of analyses. This study aims to fill the gaps in characterizing potential use cases for buildings datasets and mapping them to dataset needs using a well-defined data infrastructure. Here, we have developed a systematic mapping strategy between buildings dataset needs and use cases to help streamline the processes of efficiently targeting datasets, designing building sensing systems, and determining buildings research use cases. We selected 14 prospective use cases and 11 refined buildings data categories for developing the preliminary dataset-needs-to-use-cases mapping matrix (‘DN-UC mapping matrix’) with generic ‘Tags’—a detailed sub-level of data categories extracted by justifying the needs of an aspect of the datasets to use cases. We present two example applications of the developed mapping matrix to demonstrate use of the mapping matrix and its effectiveness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset describing two reference models for full-spectral lighting and daylight simulations together with implementations for two software systems

A dataset of two spectral lighting simulation reference models - one office and one factory hall - is presented. It aims to demonstrate and support full-spectral daylight and electric lighting simulations and facilitate evaluation of non-visual effects of light. The dataset includes Rhino CAD geometry, comprehensive spectral material and light source data and window system BSDF data. Example implementations in the two software tools, Radiance and OWL, enable reproducible workflows and support adoption in other software. The dataset is openly available on Zenodo. The office model reproduces Room 518 at the University of Innsbruck, including a west-facing façade and interior furnishings. The factory hall model follows the proposed geometry in the European standard 15193 for building energy performance. Interior reflectances in the office were measured in-situ using a handheld spectrometer. Exterior spectra and factory hall materials matching specified reflectances were obtained from an online spectral materials database. Glazing transmittance was derived from IGDB data using LBNL Optics/WINDOW. BSDFs for venetian blinds at various tilt angles, and for a diffusing pane adapted from the Complex Glazing Database, were generated in WINDOW. Luminaires in both models are specified with photometric files (Eulumdat/IES) and lamp spectra (Fluorescent 840, 4000 K LED). The provided example implementations (Radiance, OWL) include prepared input data and scripts to run first spectral simulations; example results are also included. The dataset is prepared to support reuse by researchers, designers and software developers for method validation, software engineering and comparison, and development of spectral metrics and controls.

Geisler-Moroder, David↗

An Innovative Fault Impact Analysis Framework for Enhancing Building Operations

The main goal of this paper is to rank building faults based on their impacts on the building energy penalty and occupant thermal comfort penalty considering multiple faults and fault occurrence rates. A fault impact analysis framework is created by incorporating the fault model library with the whole building energy performance simulation (e.g., EnergyPlus used in this study). The fault occurrence rate is introduced as a 'meta' parameter in the simulation. This framework involves three essential aspects of conducting a fault impact analysis: fault constructing, fault simulation, and fault impact analysis. A parametric sensitivity analysis was used to determine and rank the criticality of the faults considering the fault concurrence frequency, by using the deep-learning based response surface model (i.e., the multi-layer perceptron regression). The proposed fault analysis framework with ranking was tested and demonstrated for the DOE's prototype medium-sized office in four different climate zones (i.e., Atlanta, Chicago, Miami, and San Francisco) with 12,000 EnergyPlus fault simulations. A total of 129 fault modes from 41 groups of fault models were simulated for the medium-sized office case. The results demonstrate the proposed framework is robust and scalable for the fault impact analysis. The top critical fault for the medium-sized office is the fault of HVAC-Left-ON for the packaged rooftop unit, regarding the site energy, source energy, and HVAC energy. Excluding the fault of HVAC-Left-ON, the top critical faults vary significantly among the four climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recent Developments in Revealing the Impact of Complex Metal Oxide Reconstruction on Catalysis

Surface reconstruction of complex metal oxides refers to the alterations of the topmost catalyst surface, relative to the bulk structure, following exposure to pretreatment or reaction conditions during heterogeneous catalysis. (1) This structural and electronic transformation may involve (1) changes of the exposed crystallographic facets, (2) changes in chemical composition, such as the enrichment of specific elements, and, (3) morphological variations, including surface roughness and defects (Scheme 1). Beyond relaxation, surface reconstruction here also encompasses disruptions to the periodicity of the sublayers and changes to its stoichiometry. This change significantly influences the chemical properties of the catalyst surface, such as redox sites, (2) acid/base pairs, hydroxyl groups, (3) and surface defects. Surface reconstruction occurs due to the thermodynamic drive to lower the surface energy of the catalyst under the surrounding environment (e.g., temperature, chemical potential of species present). In addition to the treatment or reaction conditions, the extent of reconstruction also depends on the elements in the metal oxide structure. For instance, annealing ABO 3 perovskites (SrTiO 3 , BaTiO 3 , and BaZrO 3 ) at high temperatures (500 °C) in O 2 has a very different impact on the A/B ratio at the surface (ranging from 0.9 to 2.5), depending on the identity of A and B. (4) Metal oxide surface reconstruction under an electric field and exposure to acidic and alkaline media has recently gained increased attention in electrocatalysis, such as in the oxygen evolution reaction (OER); (5,6) however, in this Viewpoint we focus on the impact of surface reconstruction on thermal catalysis, a critical enduring research theme with ongoing challenges. Here, we start showcasing approaches to characterize surface reconstruction at the topmost surface layer, such as low-energy ion scattering (LEIS), discussing advantages and limitations. Next, we connect characterization of surface reconstruction to site-specific kinetic analysis, enabled via steady-state isotopic transient kinetic analysis (SSITKA), and we express our viewpoint on building structure–performance relationships by deeply understanding reconstructed surfaces. Later, we comment on the potential of tuning surface reconstruction to enhance catalytic performance. Finally, we explore the interplay between surface reconstruction and the “intelligent behavior”.