Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Analysis of Fault Data Collected from Automated Fault Detection and Diagnostic Products for Packaged Rooftop Units

Rooftop units (RTUs) and other packaged systems are very common in commercial buildings in the U.S., and they often have minimal controls and poor performance. Automated fault detection and diagnostics (AFDD) is a powerful tool that can continuously monitor operating equipment, detect abnormal performance, diagnose problems, and report findings to building operators. AFDD technologies for RTUs have been under development for many years and have recently begun to enter the market in a significant way. There are several AFDD systems available for RTUs that feature a wide range of designs, capabilities, and reporting. Unfortunately, there is little consistency among the AFDD applications and little understanding of the performance and value of these systems. This study presents analysis of AFDD data provided by four companies from over 28,000 RTUs, five building types, and multiple climate zones. The objectives of this investigation were to gain a better understanding of how RTU AFDD systems operate, the types and frequencies of faults identified, and how building operators interact with these systems. The monitoring of a variety of RTUs provides insights into the AFDD monitoring inputs, faults, and diagnostics from which these tools are capable of informing building owners about the status of their HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Carl T. Hayden Veterans Affairs Medical Center: Smart Buildings Case Study

The purpose of this smart buildings case study is to showcase a leading example of a GEB renovation project in the federal buildings space and provide key information on the technology and control upgrades, costs, and energy and utility bill savings. This case study also provides information and recommendations for selecting energy conservation measures (ECMs) and choosing energy and cost reduction strategies from the energy management team at the site. The findings from this successful GEB project can be used to help pave the way for additional GEB retrofits in the future. The Carl T. Hayden Veterans Affairs (VA) Medical Center in Phoenix, Arizona, demonstrates that GEB strategies and technologies can be realistically deployed today across buildings with substantial energy and cost savings. The project implemented both ECMs and grid-interactive technologies and controls strategies, making it a leading example of a smart, sustainable, and efficient commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Crack width control and mechanical properties of low carbon engineered cementitious composites (ECC)

Engineered Cementitious Composites (ECC) have superior properties with high tensile ductility and tight crack width compared to conventional concrete. The properties of ECC are significantly influenced by the material composition which can be tailored to enhance the sustainability of ECC. Towards this goal, recycled crumb rubber (CR) and silica fume (SF) were used to tailor the properties of a polypropylene-fiber reinforced ECC with a low carbon binder based on limestone calcined clay cement (LC3) in this study. Crumb rubber was found to be effective in enhancing strain-hardening performance and reducing the width of the multiple microcracks. However, a loss of compressive strength was accompanied by an increasing amount of CR. While silica fume or lower w/b ratio enhanced the compressive strength, the crack width of ECC increased at higher SF content or lower w/b. The underlying mechanisms of these trends were traced to the alteration of the matrix fracture toughness and fiber/matrix interfacial bond. Rubber particle bridging was found to contribute to crack width control. Finally, the combined use of the LC3 green binder and CR led to a lowering of the embodied and operational carbon footprint of ECC.

36 MATERIALS SCIENCE↗

Laboratory Validation of Integrated Lighting Systems Retrofit Performance and Energy Savings

Light-emitting diodes (LED) fixtures and lamps have emerged as leading technologies for general illumination and are a well-established energy efficiency retrofit measure in commercial buildings (from around 2% of installed fixtures and lamps in 2013 to 28% by 2020). Retrofit approaches that integrate elements, such as networked controls, daylight dimming, and advanced shade technologies lag in comparison. Integrated retrofits have been shown to increase savings over single end-use retrofits, but are perceived as higher complexity and risk. More validation of integrated lighting system performance is needed. This study presents results from laboratory testing of three packages combining fixtures, networked controls, task tuning, and daylight dimming, advanced shades, and lighting layout changes. We characterize performance in perimeter open-office zones, finding energy savings from 20% for daylight dimming and automated shades (no LED retrofit) to over 70% for LED retrofits with advanced controls and shades or lighting layout changes. We present some implementation details, including lessons learned from installation and commissioning in the laboratory setting. We also discuss cost-benefit analysis approaches for the types of packages presented, including the need to quantify and incorporate energy and non-energy benefits for advanced shades packages, which enhance occupant comfort but add significant cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrical Switching of Nematic Plasmonic Nanocolloids for Infrared Solar Gain Control

Controlling solar gain is essential to reduce the energy consumption by residential and commercial buildings, which are responsible for ≈40% of all energy generated globally. However, the dynamic control of solar gain in the near-infrared that corresponds to ≈50% of the overall Sun's energy at the Earth's surface, separately from the visible spectral range has been a challenge, albeit commercial coatings provide passive control while retaining highly visible transmission. To address this problem, in this paper switchable silver colloids (SSCs) are demonstrated, colloidal analogs of the common silver coatings used for solar gain control. When dispersed in a nematic liquid crystal, orientations of such plasmonic silver nanoplates are controlled by ≈1 V low-voltage electric fields, allowing for sub-second switching of the near-infrared-based solar gain. Installed and retrofit products made from thin films of such nanoplate dispersions confined between glass and plastic substrates, respectively, exhibit electrically controlled infrared-based solar gain while retaining high visible-range transparency, low haze, and high color rendering index. Furthermore, this study's findings reveal a great potential of soft-matter systems in addressing energy-related problems.

36 MATERIALS SCIENCE↗

Engineered Polymer Architectures for Thermo–Responsive Desiccants in Dehumidification Applications

Humidity control is relevant to many processes in buildings and manufacturing and is responsible for over 600 million tons of CO 2 annually. As such, desiccants that can efficiently remove moisture from air can greatly reduce emissions. A new class of desiccant materials, thermo–responsive desiccants, has been of increased interest in the literature. These materials are generally based on thermo–responsive polymers and exhibit a temperature–dependent isotherm, an attribute that is small in traditional desiccants. In this work, seven key parameters needed to create an effective thermo–responsive polymer desiccant are identified using a combination of modeling and experimental data. Further, it is found that more thermo–responsiveness is not necessarily better for energy efficiency, and that an optimal, “medium” value is desired. Additionally, polymer composition and architecture play key roles in adjusting the seven key parameters. Finally, based on findings from both modeling and experimental work, guidelines on synthesizing future thermo–responsive polymer desiccants are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bayesian Inference for Integrating Yarrowia lipolytica Multiomics Datasets with Metabolic Modeling

Optimizing the metabolism of microbial cell factories for yields and titers is a critical step for economically viable production of bioproducts and biofuels. In this process, tuning the expression of individual enzymes to obtain the desired pathway flux is a challenging step, in which data from separate multiomics techniques must be integrated with existing biological knowledge to determine where changes should be made. Following a design-build-test-learn strategy, building on recent advances in Bayesian metabolic control analysis, we identify in this work key enzymes in the oleaginous yeast Yarrowia lipolytica that correlate with the production of itaconate by integrating a metabolic model with multiomics measurements. To this extent, we quantify the uncertainty for a variety of key parameters, known as flux control coefficients (FCCs), needed to improve the bioproduction of target metabolites and statistically obtain key correlations between the measured enzymes and boundary flux. Based on the top five significant FCCs and five correlated enzymes, our results show phosphoglycerate mutase, acetyl-CoA synthetase (ACSm), carbonic anhydrase (HCO3E), pyrophosphatase (PPAm), and homoserine dehydrogenase (HSDxi) enzymes in rate-limiting reactions that can lead to increased itaconic acid production.

59 BASIC BIOLOGICAL SCIENCES↗

Spontaneous Reorganization of DNA-Based Polymers in Higher Ordered Structures Fueled by RNA

We demonstrate a strategy that allows for the spontaneous reconfiguration of self-assembled DNA polymers exploiting RNA as chemical fuel. To do this, we have rationally designed orthogonally addressable DNA building blocks that can be transiently deactivated by RNA fuels and subtracted temporarily from participation in the self-assembly process. Through a fine modulation of the rate at which the building blocks are reactivated we can carefully control the final composition of the polymer and convert a disordered polymer in a higher order polymer, which is disfavored from a thermodynamic point of view. We measure the dynamic reconfiguration via fluorescent signals and confocal microscopy, and we derive a kinetic model that captures the experimental results. Our approach suggests a novel route toward the development of biomolecular materials in which engineered chemical reactions support the autonomous spatial reorganization of multiple components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of superconducting through-silicon vias as capacitive elements in quantum circuits

The large physical size of superconducting qubits and their associated on-chip control structures presents a practical challenge toward building a large-scale quantum computer. In particular, transmons require a high-quality-factor shunting capacitance that is typically achieved by using a large coplanar capacitor. Other components, such as superconducting microwave resonators used for qubit state readout, are typically constructed from coplanar waveguides, which are millimeters in length. Here, we use compact superconducting through-silicon vias to realize lumped-element capacitors in both qubits and readout resonators to significantly reduce the on-chip footprint of both of these circuit elements. We measure two types of devices to show that through-silicon vias are of sufficient quality to be used as capacitive circuit elements and provide a significant reduction in size over existing approaches.

Physics↗

Tailoring Surface Roughness Using Additive Manufacturing to Improve Internal Cooling

Abstract Surface roughness present on internal cooling channels produced with additive manufacturing has been previously shown to augment heat transfer and pressure loss to levels similar to traditionally cast turbulators. Given the ability of the surface roughness to improve the cooling performance of small cooling channels, the question arises on whether there is an optimal combination of random roughness features to maximize internal cooling performance. To investigate this question, test coupons with different surface roughness morphologies and magnitudes were manufactured by manipulating the parameters in the laser powder bed fusion additive manufacturing process. The coupons were tested to characterize the friction factor and Nusselt number of the cooling channels over a range of Reynolds numbers. Results showed that certain roughness combinations outperformed others, increasing the internal cooling performance of the channels. Additionally, manipulation of the performance using the process parameters allowed for reductions in build time, which could be useful for controlling component cost.

Engineering↗

Testing and Processing of Pre-production 325 MHz Single Spoke Resonator Power Couplers for PIP-II Project

Fundamental 325 MHz power couplers are designed, built and tested for SSR cavities in PIP-II project. Couplers should work in CW mode at power level 7.5kW w/o beam and ~15 kW with the 2 mA beam. At pre-production stage we built and tested 6 couplers, produced by CPI (FNAL) and PMB (IJCLab) and 4 more couplers will be tested soon. Two of tested couplers had TiN coated ceramic window. In warm test stand two couplers were mounted on the coupling chamber and tested in SW regime at full reflection with phase controlled by position of short and reflection insert. Couplers were tested at pulse mode (up to 25kW) and cw mode (12kW) with HV bias or without bias. Test results demonstrated that 3.5 kV DC bias completely suppresses multipactor in coupler. Vacuum activity in coupler was controlled by e-pickups and build-in vacuum gauges, located near the vacuum side of window. Power processing without DC bias was done for several couplers with and without TiN coating on ceramic window. Test results are presented and discussing in paper.

43 PARTICLE ACCELERATORS↗

Storm Water Pollution Prevention Plan (SWPPP) for the Limited Area, Multi-Purpose (LAMP) High Bay Laboratory

Kier + Wright, as Qualified SWPPP Developer (QSD), puts forth this Storm Water Pollution Prevention Plan (SWPPP) for the Limited Area, Multi-Purpose (LAMP) High Bay Laboratory facility (Project) located at Sandia National Laboratories, 7011 East Avenue, CA. The property is owned by the U.S. Department of Energy, and managed and operated by National Technology & Engineering Solutions of Sandia, LLC. The project proposes converting an asphalt parking lot into a new high bay machine shop building and a low bay office building. Per the California State Water Resources Control Board’s (California State Water Board) Construction General Permit (CGP), a SWPPP is required when 1 acre or more of land is disturbed. The project site area of 1.6 acres exceeds the minimum acreage threshold of 1 acre and therefore requires SWPPP implementation. QSD has determined the sediment risk for this project, based on soil type at the site and starting and ending dates of construction, to be low (Section 3.4.1 and Appendix B). Receiving water for this project is the Arroyo Seco. QSD has determined the Arroyo Seco to be a high-risk receiving water because it has the three beneficial uses of “spawn”, “cold”, and “migratory” (Sections 3.3 and 3.4.2 and Appendix B). QSD has determined the overall risk level for the site to be Risk Level 2, based on a combination of low sediment risk and high receiving water risk (Appendix B). As such, QSD has delineated a variety of Best Management Practices (BMPs) to be employed during project construction to reduce or eliminate pollutants in stormwater runoff or any other discharges from the Project site. In addition to site-specific BMPs, this SWPPP report provides instruction for on site monitoring. Electronic copies of required documentation such as inspection reports, REAPs, annual report documentation, etc. shall be submitted to NTESS Sandia Delegated Representative via Newforma.

54 ENVIRONMENTAL SCIENCES↗

TESTING AND PROCESSING OF PRE-PRODUCTION 325 MHZ SINGLE SPOKE RESONATOR POWER COUPLERS FOR PIP-II PROJECT

Fundamental 325 MHz power couplers are designed, built and tested for SSR cavities in PIP-II project [1]. Couplers should work in CW mode at power level 7.5kW w/o beam and ~15 kW with the 2 mA beam. At pre-production stage we built and tested 6 couplers, produced by CPI (FNAL) and PMB (IJCLab) and 4 more couplers will be tested soon. Two of tested couplers had TiN coated ceramic window. In warm test stand two couplers were mounted on the coupling chamber and tested in SW regime at full reflection with phase controlled by position of short and reflection insert. Couplers were tested at pulse mode (up to 25kW) and cw mode (12kW) with HV bias or without bias. Test results demonstrated that 3.5 kV DC bias completely suppresses multipactor in coupler. Vacuum activity in coupler was controlled by e-pickups and build-in vacuum gauges, located near the vacuum side of window. Power processing without DC bias was done for several couplers with and without TiN coating on ceramic window. Test results are presented and discussing in paper.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Predicting Selective Laser Printing Print Quality of Polymer Powders through Melt Flow Index

Selective Laser Sintering (SLS) uses a precisely controlled laser to fuse polymer powder to build complex 3D shapes. While SLS covers a wide application space, the processing knowledge of polymer powder is limited, restricting the number of commercial powders available. This study serves to expand the processing knowledge of polypropylene and polyethylene in parallel with a “mature” SLS feedstock, nylon, through melt flow index (MFI) characterization. Differential Scanning Calorimetry (DSC) was used to explore the sintering window of the polymers. Polyethylene and polypropylene exhibited a relatively narrow sintering window between 4 – 5 °C, whereas the sintering window of nylon was much wider, between 23 – 24 °C. This suggests that the print quality between polyethylene and polypropylene would be similar; however, X-ray computed tomography revealed a higher volume of print defects, voids, and de lamination in polyethylene than in polypropylene. MFI analysis provided additional insight into the difference in print quality, as the MFI of polyethylene was 7.16 g/10 min, 9.95 g/10 min for polypropylene, and 17.23 g/10 min for nylon. MFI is inversely correlated to melt viscosity, and a low melt viscosity is desired for proper coalescing between the layers and particles. These results suggest that MFI is a promising tool, in conjunction with traditional thermal analysis, for screening candidate powder feedstocks for SLS and optimization of print parameters for novel powders.

36 MATERIALS SCIENCE↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗