Stochastic Home Energy Management Systems with Varying Controllable Resources

This paper studies the performance of a model predictive control (MPC) algorithm in a home energy management system (HEMS) as the set of controllable resources varies and under both a constant and a time-of-use (TOU) electricity price structure. The set of controllable resources includes residentially-owned photovoltaic (PV) panels, a home battery system (HBS), an electric vehicle (EV), and a home heating, ventilation, and air conditioning (HVAC) system. The HEMS optimally schedules the set of controllable resources given user preferences such as indoor thermal comfort and electricity cost sensitivity. The home energy management system is built on a chance constrained, MPC-based algorithm, where the chance constraint ensures the indoor thermal comfort is satisfied with a high probability given uncertainty in the outdoor temperature and solar irradiance forecasts. Simulation results for varying sets of controllable resources under two different electricity price structures demonstrate the variation in the HEMS control with respect to HBS operation, electricity cost, and grid power usage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable Predictive Control and Optimization for Grid Integration of Large-Scale Distributed Energy Resources

Integrating a large number of distributed energy resources (DERs) into the power grid needs a scalable power balancing method. We formulate the power balancing problem as a look-ahead optimization problem to be solved sequentially by a power distribution system aggregator based on a model predictive control (MPC) framework. Solving large-scale look-ahead control problems requires proper configuration of the control steps. In this paper, to solve large-scale control problems, we propose a variable time granularity where control time steps nearby the current control step have finer resolutions. The aggregator objective includes maximization of power production revenue and minimization of power purchasing expense, renewable power curtailment, and mileage costs for energy storage and electric vehicle (EV) charging stations while satisfying system capacity and operational constraints. The control problem is formulated as a mixed-integer linear program (MILP) and solved using the XpressMP solver. We perform simulations considering a copper plate representation of a large distribution network consisting of 2507 devices (control-lable DERs), including curtailable photovoltaics (PVs), energy storage batteries, EV charging stations, and buildings with heating, ventilation, and air conditioning units (HVACs). We show the effectiveness of the proposed approach in managing DERs interactively for maximum energy trading profit and local supply-demand power balancing. Finally, we demonstrate that the proposed method outperforms other benchmark controllers regarding computation time without compromising operational performance.

DER↗

Liquid Rocket Booster (LRB) for the Space Transportation System (STS) systems study. Appendix C: Battery report for the liquid rocket booster TVC actuators

The actuators for control of engine valves and gimbals for a booster require 165 kW or more peak power at 270 volts direct current (VDC) during the 2 or 3 minutes of first stage ascent; other booster devices require much less power at 28 VDC. It is desired that a booster supply its own electrical power and satisfy redundancy requirements of the Solid Rocket Booster Shuttle, when applicable. The power of a Liquid Rocket Booster is therefore provided by two subsystems: Actuator Battery Power (270 VDC) Subsystem for the engine actuators, and Electrical Power and Distribution (28 VDC) Subsystem, to power everything else. Boosters will receive no electrical power from Orbiter, only commands and data, according to current plans. It was concluded that nine 30 volt silver-zinc batteries-in-series be used to provide the 270 volt, 37 kW average (165 kW peak).

Source record↗

Psychology of computer use: IX. A menu of self-administered microcomputer-based neurotoxicology tests

This study examined the feasibility of repeated self-administration of a newly developed battery of mental acuity tests which may have application in screening for fitness-for-duty or for persons who may be exposed to environmental stress, toxic agents, or disease. 16 subjects self-administered 18 microcomputer-based tests (13 new, 5 "core"), without proctors, over 10 sessions. The hardware performed well throughout the study and the tests appeared to be easily self-administered. Stabilities and reliabilities of the tests from the "core" battery were comparable to those obtained previously under more controlled experimental conditions. Eight of the new tests exceeded minimum criteria for metric and practical requirements and can be recommended as additions to the menu. Although the average retest reliability was high, cross-correlations between tests were low, implying factorial diversity. The menu can be used to form batteries with flexible total testing time which are likely to tap different mental processes and functions.

NASA Discipline Neuroscience↗

Virtual Battery Aggregator (Virtual Battery Aggregator for Distributed Energy Resource Management Systems)

Distributed energy resource management systems (DERMS) are being deployed in feeders with high distributed energy resource (DER) penetration to provide visibility of DERs and enable DER control strategies for grid operators. DERMS can support centralized grid controls by aggregating individual DER information into a single virtual DER model. This codebase creates algorithms for a DERMS platform that are able to aggregate a set of DERs that can be modeled as batteries, create a virtual battery model for centralized grid controls, and dispatch power setpoints to the individual DERs based on a desired virtual power setpoint received from the centralized grid control. It integrates with existing co-simulation frameworks and models for buildings, DERs, and distribution systems. While the DERMS is designed to work with batteries, it can be used with any DER that can be defined by a generalized battery model.

Blonsky, Michael↗

Design description of the Schuchuli Village photovoltaic power system

A stand alone photovoltaic (PV) power system for the village of Schuchuli (Gunsight), Arizona, on the Papago Indian Reservation is a limited energy, all 120 V (d.c.) system to which loads cannot be arbitrarily added and consists of a 3.5 kW (peak) PV array, 2380 ampere-hours of battery storage, an electrical equipment building, a 120 V (d.c.) electrical distribution network, and equipment and automatic controls to provide control power for pumping water into an existing water system; operating 15 refrigerators, a clothes washing machine, a sewing machine, and lights for each of the homes and communal buildings. A solar hot water heater supplies hot water for the washing machine and communal laundry. Automatic control systems provide voltage control by limiting the number of PV strings supplying power during system operation and battery charging, and load management for operating high priority at the expense of low priority loads as the main battery becomes depleted.

Ratajczak, A. F.↗

The 50 AMP-hour nickel cadmium battery manual

The battery is designed with a minimum battery to cell weight ratio consistent with adequate containment for operating conditions and dynamic environments and minimized weight. The battery is fully qualified and the environments to which it was successfully subjected were selected by NASA Goddard to cover a wide range of probable uses. The battery is suitable for either near-Earth geosynchronous missions, is compatible with passive or active thermal control systems and may be electrically controlled by a variety of changing routines. The initial application of the 50 A.H. Battery is a near-Earth mission aboard the LANDSAT D Satellite.

Webb, D. A.↗

Complexing Agent-Assisted Membraneless Zinc–Iodine Aqueous Batteries

A membrane is required for conventional zinc–iodine aqueous batteries, since soluble polyiodides cross over to the anode side and react with zinc metal spontaneously. Making the battery membraneless increases ion transport and reduces its cost and overall footprint. In this paper, a membraneless Zn–I 2 aqueous battery is demonstrated, employing a complexing agent, 1-butyl-1-methylpyrrolidinium iodide (MBPI), to promote the formation of I 5 – -containing, phase-separated polyiodides upon charging, to minimize self-discharge and suppress Zn dendrite growth. With an additional 0.3 M MBPI in 4 M ZnI 2 electrolyte, the membraneless battery achieved 65 cycles with >85% Coulombic efficiency, whereas the MBPI-free control failed immediately. Additionally, a volumetric capacity of 14.3 Ah L –1 was achieved, surpassing those of most membraneless batteries reported to date regardless of redox chemistry, and underscores the potential of complexing agents in simplifying the architecture of conventional Zn–I 2 flow batteries.

25 ENERGY STORAGE↗

Comparative and Cost Analysis of a Novel Predictive Power Ramp Rate Control Method: A Case Study in a PV Power Plant in Puerto Rico

One of the most important aspects that need to be addressed to increase solar energy penetration is the power ramp-rate control. In weak grids such as the one found in Puerto Rico, it is important to smooth power fluctuations caused by the intermittence of passing clouds. In this work, a novel power ramp-rate control strategy is proposed. Additionally, a comparison with some of the most common power ramp-rate control methods is performed using a proposed model and real solar radiation data from the Coto Laurel photovoltaic power plant located in Ponce, Puerto Rico. The proposed model was validated using one-year real data from Coto Laurel. The power ramp-rate control methods were compared in real-time simulations using the OP5700 from Opal-RT Technologies considering power ramp rate fluctuations, power ramp-rate violations, fluctuations in the state-of-charge, among other indicators. Moreover, the proposed power ramp-rate control strategy, called predictive dynamic smoothing was explained and compared. Results indicate that the predictive dynamic smoothing produced a considerably reduced Levelized Cost of Storage compared to other power ramp-rate control methods and provided a higher lifetime expectancy for lithium batteries.

36 MATERIALS SCIENCE↗

Electrical resistance of the current collector controls lithium morphology

Abstract The electrodeposition of low surface area lithium is critical to successful adoption of lithium metal batteries. Here, we discover the dependence of lithium metal morphology on electrical resistance of substrates, enabling us to design an alternative strategy for controlling lithium morphology and improving electrochemical performance. By modifying the current collector with atomic layer deposited conductive (ZnO, SnO 2 ) and resistive (Al 2 O 3 ) nanofilms, we show that conductive films promote the formation of high surface area lithium deposits, whereas highly resistive films promote the formation of lithium clusters of low surface area. We reveal an electrodeposition mechanism in which radial diffusion of electroactive species is promoted on resistive substrates, resulting in lateral growth of large (150 µm in diameter) planar lithium deposits. Using resistive substrates, similar lithium morphologies are formed in three distinct classes of electrolytes, resulting in up to ten-fold improvement in battery performance. Ultimately, we report anode-free pouch cells using the Al 2 O 3 -modified copper that maintain 60 % of their initial discharge capacity after 100 cycles, displaying the benefits of resistive substrates for controlling lithium electrodeposition.

25 ENERGY STORAGE↗

NASA Alternative Orion Small Cell Battery Design Support

The NASA Orion Crew Module Reference Design was produced to address large scale thermal runaway (TR) hazard with specific safety controls for the Orion Spacecraft. The design presented provides the description of a full scale battery design reference for implementation as a drop in replacement to meet all spacecraft energy requirements with compatible 120 Vdc electrical and mechanical interface using small cell technology (18650) packaging. The 32V SuperBrick incorporates unique support features and an electrical bus bar arrangement that allows cells negative can insertion into heat sink that is compressively coupled to the battery enclosure to promote good thermal management. The housing design also provides an internal flame suppression "filter tray" and positive venting path internal to the enclosure to allow hot effluent ejecta to escape in the event of single cell TR. Virtual cells (14P Banks) that are supported to provide cell spacing with interstitial materials to prevent side can failures that can produce cell to cell TR propagation. These features were successfully test in four separate TR run with the full scale DTA1 test article in February 2016. Successfully Completed Test Objectives - Four separate TR test runs with Full-Scale DTA1 housing with Two SuperBricks, Two SuperBrick Emulators All Tests resulted in "clean" gas with less than 6 C rise at Battery vent All Tests resulted in less than 2 C temperature rise on cold-plate outlet All Tests resulted in less than 6 psi pressure rise in the battery housing Test Run 1 -One neighbor cell TR, highest remaining neighbor 139 C. Ejecta shorted to bus caused prolonged additional heating, One shorted cell did experience TR after 12 minutes, remaining cells had adequate thermal margin Test Run 2 - No cell to cell propagation, highest neighbor cell 112 C; Test Run 3 - No cell to cell propagation, highest neighbor cell 96 C; Test Run 4 - No cell to cell propagation, highest neighbor cell 101 C; Primary TR testing and analysis were completed and reviewed for endorsement by NASA Engineering and Safety Center team members. All Key Test Objectives were met and the small cell design alternative was demonstrated and selected to be a feasible drop in replacement for the MPCV Orion CM Battery for EM2 mission.

Haynes, Chuck↗

Power Converter Design for the Europa Lander Motor Controller

This paper will outline the design and test results for the Europa Lander motor controller’s Power Conversion Slice. Europa Lander is a proposed NASA mission concept to send a stationary spacecraft to Jupiter’s Icy Moon, Europa, to search for subsurface biosignatures. The Power Conversion Card is one of the many technologies designed for this mission. The Power Conversion Card’s primary function is to convert the power supplied by the spacecraft battery to usable power for use within the motor controller. In addition, this card provides power system telemetry to the spacecraft computer. This card tolerates Europa’s harsh radiation environment within a protected vault to enable it to survive the external temperatures which can be as low as -184°C during the three-week mission. This design makes use of multiple commercially available radiation hardened electronics, including Cobham’s UT32M0R500 Arm Microcontroller along with VPT’s DC-DC Converters for power conversion. The microcontroller is used to collect local power system telemetry and assess card health autonomously without intervention from the spacecraft’s main computer. This paper will showcase the design behind the prototype and electrical testing results.

Lias, Malcolm↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗

Highly Loaded Sulfur Cathode, Coated Separator and Gel Electrolyte for High Rate Li-Sulfur Batteries

As one of DOE Battery 500 Seedling projects, Cornell University and EIC Labs investigated and developed i) highly loaded sulfur cathodes (> 3 mg/cm 2 ), ii) hybrid separators, and iii) gel ceramic electrolytes (GCE) to mitigate the low rate capability, shuttling effect and limited cycle life in high performance Li-Sulfur batteries. Scalable nanomanufacturing processes such as air-controlled electrospray (ACES) and gas-assisted electrospinning (GAES) have been utilized to develop directly deposited electrodes and polymer/ceramic hybrid separators. First, in the development of highly loaded cathodes, alternating layers of sulfur impregnated mesoporous carbon and graphene were fabricated via ACES and the resulting layered cathodes and coated separators exhibit higher capacity and capacity retention (about 1,000 mAh/g capacity with less than 0.02% fade/cycles) than single layer cathode or cathode prepared by conventional slurry cast. Alternating layer approach via ACES has been applied to high loading systems (3 - 5 mg S/cm 2 ), demonstrating the potential to increase sulfur utilization and capacity retention. We have also incorporated iron oxides (Fe 3 O 4 ) into S/mesoporous carbon/graphene cathodes to enhance sulfur utilization and mitigation of polysulfide shuttling. and the effect of Fe 3 O 4 in mesoporous carbon and Gr is highly pronounced at high C rates of 1C and 2C cycling performance. To further improve the cathodes at high rates, graphene nanoribbons (GNR) which can promote ion transport were incorporated in the cathode, resulting in 550 mAh/g at 5C/5C rates. Hybrid Li-ion/Li-S cathodes has also been explored to better engage unreacted polysulfides during charge/discharge. S/LFP hybrid cathodes offer higher sulfur utilization and enhanced rate capability, as well as higher areal loading. This study suggests inclusion of iron phosphide (Fe2P) which can chemically interact with polysulfides can further enhance sulfur utilization and mitigation of soluble polysulfides at high rates. Secondly, in the development of hybrid separators, we first employed graphene coating on the commercial polyolefin separators, which exhibits higher capability, better capacity retention and enhanced rate capability. To improve the rate capability with enhanced safety features such as thermal stability and nonflammability, we developed polymer/ceramic hybrids based on thermally stable polyimide (PI) and room temperature curable ceramic precursors such as organopolysilazane (OPSZ) or polysilsesquioxanes (PSSQ), which exhibit no shrinkages up to 300 ºC and non-flammability. To improve mechanical properties and electrochemical stability, polybenzimidazole (PBI) and alumina have been incorporated in polymer/ceramic hybrid separator, replacing PI and OPSZ/PSSQ, respectively. Finally, the gel ceramic electrolyte (GCE) based on ceramic cross linkers have been applied to make Li-S cells even safer and also to mitigate the polysulfide shuttling further. The resulting gel ceramic electrolyte offers improved capacity retention and rate capability, and also effectively mitigates polysulfide shuttling which was also confirmed by modeling. Inclusion of high ion conducting additives into GCE together with polymer/ceramic hybrid separators exhibit the higher ionic conductivity than liquid electrolyte with commercial polyolefin separator. We demonstrated that the developed highly loaded sulfur cathodes, polymer/ceramic hybrid separators and gel ceramic electrolyte can effectively mitigate the low rate capability, shuttling effect and limited cycle life in high performance Li-Sulfur batteries with improved safety.

25 ENERGY STORAGE↗

Thermal regulation of batteries

A battery thermal management system for an air vehicle includes a liquid heat exchange circuit. The system includes at least one battery in thermal communication with the liquid heat exchange circuit. The system includes a controller operatively connected to the liquid heat exchange circuit. The controller is configured and adapted to variably select whether heat will be rejected to the liquid heat exchange circuit. The system includes at least one heat exchanger positioned on the liquid heat exchange circuit. The at least one heat exchanger is a liquid-air heat exchanger or a liquid-liquid heat exchanger. A method for controlling a thermal management system for an air vehicle includes determining an expected temperature of at least one battery, and cooling the at least one battery with a cooling device if the expected temperature exceeds a pre-determined expected temperature threshold.

Rheaume, Jonathan↗

Microprocessor control of multiple peak power tracking DC/DC converters for use with solar cell arrays

A method and an apparatus is provided for efficiently controlling the power output of a solar cell array string or a plurality of solar cell array strings to achieve a maximum amount of output power from the strings under varying conditions of use. Maximum power output from a solar array string is achieved through control of a pulse width modulated DC/DC buck converter which transfers power from a solar array to a load or battery bus. The input voltage from the solar array to the converter is controlled by a pulse width modulation duty cycle, which in turn is controlled by a differential signal controller. By periodically adjusting the control voltage up or down by a small amount and comparing the power on the load or bus with that generated at different voltage values a maximum power output voltage may be obtained. The system is totally modular and additional solar array strings may be added to the system simply by adding converter boards to the system and changing some constants in the controller's control routines.

Frederick, Martin E.↗

Model Predictive Voltage Control of Large-Scale PV or Hybrid PV-BESS Plants

Increased penetration level of inverter-based resources (IBRs) and renewable energy in the power grid has called for more requirements from the control of IBRs. In this paper, the voltage-reactive power control of a photovoltaic (PV) power plant or hybrid PV-battery energy storage system (BESS) plant connected to a bulk power grid, whilst meeting the grid requirements, is studied. In this paper, a continuous-set model predictive control (MPC) formulation is proposed for voltage-reactive power control. For the same, an aggregated dynamic PV plant model is developed based on the recursive system equivalencing method. The formulation is then implemented in PSCAD simulation on a 125 MW PV plant or hybrid PV-BESS plant. The MPC implementation achieves 10.13% voltage improvement based on PSCAD simulation results in a balanced fault case study. Simulation results further demonstrate that MPC provides improved voltage support over the conventional proportional-integral (PI) controller post-fault occurrence.

Abu rub, Omar↗

Space Shuttle Upgrades Advanced Hydraulic Power System

Three Auxiliary Power Units (APU) on the Space Shuttle Orbiter each provide 145 hp shaft power to a hydraulic pump which outputs 3000 psi hydraulic fluid to 41 hydraulic actuators. A hydrazine fuel powered APU utilized throughout the Shuttle program has undergone many improvements, but concerns remain with flight safety, operational cost, critical failure modes, and hydrazine related hazards. The advanced hydraulic power system (AHPS), also known as the electric APU, is being evaluated as an upgrade to replace the hydrazine APU. The AHPS replaces the high-speed turbine and hydrazine fuel supply system with a battery power supply and electric motor/pump that converts 300 volt electrical power to 3000 psi hydraulic power. AHPS upgrade benefits include elimination of toxic hydrazine propellant to improve flight safety, reduction in hazardous ground processing operations, and improved reliability. Development of this upgrade provides many interesting challenges and includes development of four hardware elements that comprise the AHPS system: Battery - The battery provides a high voltage supply of power using lithium ion cells. This is a large battery that must provide 28 kilowatt hours of energy over 99 minutes of operation at 300 volts with a peak power of 130 kilowatts for three seconds. High Voltage Power Distribution and Control (PD&C) - The PD&C distributes electric power from the battery to the EHDU. This 300 volt system includes wiring and components necessary to distribute power and provide fault current protection. Electro-Hydraulic Drive Unit (EHDU) - The EHDU converts electric input power to hydraulic output power. The EHDU must provide over 90 kilowatts of stable, output hydraulic power at 3000 psi with high efficiency and rapid response time. Cooling System - The cooling system provides thermal control of the Orbiter hydraulic fluid and EHDU electronic components. Symposium presentation will provide an overview of the AHPS upgrade, descriptions of the four hardware elements, and a summary of development results to date.

Source record↗