Davis-Besse Water Processing System Upgrade - 19654
This paper looks at the in-house liquid radwaste (LRW) processing system configuration at Davis-Besse Nuclear Power Station in Oak Harbor, Ohio. The suboptimal performance of that system, which had been in service for over three decades, prompted Plant Management to canvass the industry for LRW processing technologies and techniques that might offer improvements. The goal was to upgrade water processing performance at Davis-Besse, particularly during outages, when water generation is high and the most difficult to decontaminate water is produced. This paper reviews the goals established by Management to guide the selection of technology and equipment components. The chosen vendor would be responsible for designing a system that would incorporate the plant's existing equipment as much as feasible, while respecting the limited space and funding available for the project. The LRW processing system changes eventually made by Davis-Besse are identified and discussed. We also offer a summary of pre- and post-upgrade operation and performance in vital areas, including manpower requirements (for operation and maintenance), effluent quality, waste production and overall operating cost. The information and experiences cited in this paper are directly applicable to other nuclear power plants who might contemplate an upgrade of LRW processing systems or of individual system components. (authors)