Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Water Impact Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Poly(methylene-co-cyanoguanidine) as an Eco-friendly Nitrogen Fertilizer with Prolonged Activity

Poly(methylene-co-cyanoguanidine), PMCG, is an oligomeric polycation that has found its application in the waste-water treatment as well as in preparation of polyelectrolyte complex microcapsules for biomedical purposes. Considering the nitrogen-rich composition of repeating unit, PMCG may be a valuable polycation utilized as a novel slow-release fertilizer. The aim of this study was to evaluate the potential of PMCG as a nitrogen fertilizer during its 6-month incubation in the soil. Monocotyledonous oat (Avena sativa) and dicotyledonous radish (Raphanus sativus L.) were selected as representative model plants for plant growth test. The effect of PMCG on plant growth and development was dependent on both the PMCG concentration and time of incubation. An increase in the nitrogen amount in green parts of plants demonstrated the uptake of the plant-available form of nitrogen released from PMCG incubated in the soil. This resulted in an increased percentage of fresh matter and shoot height of the tested plants during their exposure to PMCG. Ecotoxicological impact of PMCG in the soil during incubation period against bacteria Allivibrio fischeri and crustacean Heterocypris incongruens was also assessed. PMCG was found as the potential polymer fertilizer that does not require special treatment and can be used as it is for the prolonged release of nitrogen in agriculture.

54 ENVIRONMENTAL SCIENCES↗

Nevada National Security Site 2013 Waste Management Monitoring Report Area 3 and Area 5 Radioactive Waste Management Site

Environmental monitoring data are collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) within the Nevada National Security Site (NNSS). These data are associated with radiation exposure, air, groundwater, meteorology, and vadose zone. This report summarizes the 2013 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (National Security Technologies, LLC, 2013; 2014a; 2014b). Direct radiation monitoring data indicate exposure levels at the RWMSs are within the range of background levels measured at the NNSS. Slightly elevated exposure levels outside the Area 3 RWMS are attributed to nearby historical aboveground nuclear weapons tests. Air monitoring data show tritium concentrations in water vapor and americium and plutonium concentrations in air particles are close to detection limits and background levels. The measured levels of radionuclides in air particulates and moisture are below Derived Concentration Standards for these radionuclides. Groundwater monitoring data indicate the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by RWMS operations. Results of groundwater analysis from wells around the Area 5 RWMS were all below established investigation levels. Leachate samples collected from the leachate collection system at the mixed low-level waste cell were below established contaminant regulatory limits. The 105.8 millimeters (mm) (4.17 inches [in.]) of precipitation at the Area 3 RWMS during 2013 is 30% below the average of 150.3 mm (5.92 in.), and the 117.5 mm (4.63 in.) of precipitation at the Area 5 RWMS during 2013 is 5% below the average of 123.6 mm (4.86 in.). Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter dries the soil and prevents downward percolation of precipitation more effectively than evaporation from the bare-soil weighing lysimeter. Automated vadose zone monitoring on Area 5 and Area 3 RWMS cell covers show no evidence of precipitation percolating through the cover to the waste. Moisture from precipitation did not percolate below 60 centimeters (cm) (2 feet [ft]) in the vegetated final cover on the U-3ax/bl disposal unit at the Area 3 RWMS, and moisture from precipitation and irrigation did not percolate below 45 cm (1.5 ft) on the 92-Acre Area final cover. Irrigation was applied to this cover for seed germination and plant growth. During 2013, there was no drainage through 2.4 meters (8 ft) of soil from the Area 3 drainage lysimeters that received only natural precipitation. Twenty percent of the applied precipitation and irrigation drained from the bare-soil drainage lysimeter that received 3-times natural precipitation. All 2013 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing within expectations of the model and parameter assumptions for the facility PAs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

3D Printing Catalytic Electrodes for Solar-Hydrogen Devices

Hydrogen production through water-splitting systems showed promising pathway to achieve <$2/kg cost target set by Department of Energy (DOE). As far, most efforts have been devoted to new electrocatalytical materials discovery. In contrast, the impact of architecture of the electrocatalysts as well as mass transport within the gas diffusion layers has not been well explored. In this project, we developed a new ink formulation with earth-abundant elements nickel and molybdenum (NiMo) for catalytical 3-dimentional (3D) electrodes in water-splitting devices. The NiMo electrodes fabricated via additive manufacturing have been characterized and tested. The architecture, morphology and compositions of the NiMo electrodes have been confirmed by Scanning Electric Microscopy (SEM) and Powder X-Ray Diffraction (XRD). We have demonstrated that the catalyst precursor survived the whole fabrication and post-treatment process. Furthermore, the NiMo 3D electrodes in this study exhibited state-of-art hydrogen evolution reaction (HER) performance, ~ 60 mV over potential for over 24 hours operation. The high performance of the 3D catalytical electrodes is attributed to large roughness factors (RF) of the electrodes and highly efficient mass transport. This study is in line with DOE initiative H2@Scale and national energy security missions at LLNL.

36 MATERIALS SCIENCE↗

Performance of Integrated Hydronic Heating Systems.

A variety of system configurations are used in North America to meet the heating and domestic hot water needs of single-family homes. This includes, for example: warm air furnaces with electric water heaters; boilers with integrated hot water coils; and boilers with 'indirect' hot water storage tanks. Integrated hydronic systems which provide both heat and hot water are more popular only in the Northeast and mid-Atlantic regions. For those making decisions about configurations of these integrated hydronic systems, including control options, little information is available concerning the annual energy cost implications of these decisions. This report presents results of a project to use a direct load emulation approach to measure the performance of hydronic systems, develop performance curves, and to provide decision tools to consumers. This is a laboratory measurement system involving direct energy input and output measurements under different load patterns. These results are then used to develop performance correlations for specific systems that can be used to predict energy use in specific applications. A wide range of system types have been tested under this project including conventional boilers with 'tankless' internal coils for domestic hot water production, boilers with indirect external storage tanks, tank type water heaters which may also be used for space heating, condensing oil- and gas-fired systems, and systems with custom control features. It is shown that low load and idle energy losses can have a very large impact on the total annual energy use and that the potential energy savings associated with replacing old equipment with newer, high efficiency equipment with low losses at idle or low load can be in the 25% range. These savings are larger than simple combustion efficiency measurements would indicate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of an Automated Touchdown Detection Algorithm for the Orion Crew Module

Orion Crew Module (CM) touchdown detection is critical to activating the post-landing sequence that safe?s the Reaction Control Jets (RCS), ensures that the vehicle remains upright, and establishes communication with recovery forces. In order to accommodate safe landing of an unmanned vehicle or incapacitated crew, an onboard automated detection system is required. An Orion-specific touchdown detection algorithm was developed and evaluated to differentiate landing events from in-flight events. The proposed method will be used to initiate post-landing cutting of the parachute riser lines, to prevent CM rollover, and to terminate RCS jet firing prior to submersion. The RCS jets continue to fire until touchdown to maintain proper CM orientation with respect to the flight path and to limit impact loads, but have potentially hazardous consequences if submerged while firing. The time available after impact to cut risers and initiate the CM Up-righting System (CMUS) is measured in minutes, whereas the time from touchdown to RCS jet submersion is a function of descent velocity, sea state conditions, and is often less than one second. Evaluation of the detection algorithms was performed for in-flight events (e.g. descent under chutes) using hi-fidelity rigid body analyses in the Decelerator Systems Simulation (DSS), whereas water impacts were simulated using a rigid finite element model of the Orion CM in LS-DYNA. Two touchdown detection algorithms were evaluated with various thresholds: Acceleration magnitude spike detection, and Accumulated velocity changed (over a given time window) spike detection. Data for both detection methods is acquired from an onboard Inertial Measurement Unit (IMU) sensor. The detection algorithms were tested with analytically generated in-flight and landing IMU data simulations. The acceleration spike detection proved to be faster while maintaining desired safety margin. Time to RCS jet submersion was predicted analytically across a series of simulated Orion landing conditions. This paper details the touchdown detection method chosen and the analysis used to support the decision.

Gay, Robert S.↗

Pick-and-Eat Space Crop Production Flight Testing on the International Space Station

Growing fresh, nutritious, palatable produce for crew consumption during spaceflight may provide health-promoting, bioavailable nutrients and enhance the astronaut dietary experience as we move toward longer-duration missions. However, requirements to support consistent growth of a variety of high-quality crops under spaceflight environmental conditions remain unclear. This study explores the potential to grow crops for consumption on the International Space Station (ISS) using Veggie, NASA’s vegetable production chamber system. VEG-04A and VEG-04B were two flight tests with ground components conducted with the leafy green crop mizuna mustard. In each location, mizuna was grown in two Veggie units simultaneously, with the chambers set to different red-to-blue-to-green light formulations. Preflight verification testing with various lighting treatments was conducted to down-select two treatments that contributed to the best desirable growth and sensory qualities in mizuna mustard. For the flight tests, one Veggie was programmed as “red-rich” with an average of 270 μmol m-2 s-1 of 630 nm red light, 30 μmol m-2 s-1 of 455 nm blue light, and 30 μmol m-2 s-1 of 530 nm green light. The second Veggie was “blue-rich” with an average of 150 µmol m-2 s-1 of 630 nm red light, 150 µmol m-2 s-1 of 455 nm blue light, and 30 µmol m-2 s-1 of 530 nm green light. Light quality is known to impact plant growth, nutrition, microbiology, and sensory characteristics on Earth, and the Veggie flight tests examined how these impacts might differ in microgravity. VEG-04A, a 35-day growth test with a single harvest, was initiated in June and harvested in July 2019. VEG-04B, a 56-day test with three harvests from the same plants, assessed sustained productivity. Preflight testing for VEG-04B was conducted after the VEG-04A flight test to improve the operations, approaches, and watering requirements, which resulted in better crop establishment in the VEG-04B flight test. VEG-04B was initiated in October 2019 with harvests at four, six, and eight weeks after initiation. At all of the harvests, the astronauts froze half of the edible plant tissue to return to Earth and weighed the remaining half using the Mass Measurement Device (MMD). Weighed samples were then cleaned with produce-sanitizing wipes, and consenting crew members participated in sensory evaluations of the fresh produce. The remaining sanitized produce was available for crew consumption as desired. Frozen flight samples were returned to Earth for chemical and microbial analyses to assess nutritional quality and food safety. Flight-grown mizuna was generally more acceptable to the crew and had higher nutrient levels, although mizuna grown in the ground control performed better in terms of higher yield and lower microbial load. This presentation will focus on results from the nutritional and sensory analyses, including how nutrients identified as key for supplementing the crew diet varied across lighting treatments, harvest approaches, and spaceflight versus ground conditions. It is our hope that these tests on the ISS will help mitigate the risk of an inadequate food supply for long-duration missions by adding fresh vegetables to the crew diet. This study was supported by NASA’s Human Research and Space Biology Programs through the HERO NNJ13ZSA002N-ILSRA grant solicitation.

Jess Bunchek↗

Aerosol Formation from High-Pressure Sprays for Supporting the Safety Analysis for the Hanford Waste Treatment and Immobilization Plant

The Waste Treatment and Immobilization Plant (WTP) at Hanford is being designed and built to pretreat and vitrify waste currently stored in underground tanks at Hanford. One of the postulated events in the hazard analysis for the WTP is a breach in process piping that produces a pressurized spray with small droplets that can be transported into ventilation systems. Literature correlations are currently used for estimating the generation rate and size distribution of aerosol droplets in postulated spray releases. These correlations, however, are based on results obtained from small engineered nozzles using Newtonian liquids that do not contain slurry particles and thus do not accurately represent the fluids and breaches in the WTP. A test program was developed to measure the generation rate of droplets suspended in a test chamber and droplet size distribution from a range of prototypic sprays. A novel test method was developed to allow measurement of sprays from small to very large breaches and also includes the effect of aerosol generation from splatter when the spray impacts on walls. Results show that the aerosol generation rate increases with increasing the orifice area, though with a weaker dependence on orifice area than the currently-used correlation. A comparison of water sprays to slurry sprays with 8 to 20 wt% gibbsite or boehmite particles shows that the presence of slurry particles depresses the release fraction compared to water for droplets above 10 μm and increases the release fraction below this droplet size.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nevada National Security Site 2012 Waste Management Monitoring Report Area: 3 and Area 5 Radioactive Waste Management Sites

Environmental monitoring data are collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada National Security Site (NNSS). These data are associated with radiation exposure, air, groundwater, meteorology, and vadose zone. This report summarizes the 2012 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (National Security Technologies, LLC, 2012; 2013a; 2013b). Direct radiation monitoring data indicate exposure levels at the RWMSs are within the range of background levels measured at the NNSS. Slightly elevated exposure levels outside the Area 3 RWMS are attributed to nearby historical aboveground nuclear weapons tests. Air monitoring data show tritium concentrations in water vapor and americium and plutonium concentrations in air particles are only slightly above detection limits and background levels. The measured levels of radionuclides in air particulates and moisture are below Derived Concentration Standards for these radionuclides. Groundwater monitoring data indicate the groundwater in the uppermost aquifer beneath the Area 5 RWMS is not impacted by RWMS operations. Results of groundwater analysis from wells around the Area 5 RWMS were all below established investigation levels. Leachate samples collected from the leachate collection system at the mixed low-level waste cell were below established contaminant regulatory limits. The 133.9 millimeters (mm) (5.27 inches [in.]) of precipitation at the Area 3 RWMS during 2012 is 12% below the average of 153.0 mm (6.02 in.), and the 137.6 mm (5.42 in.) of precipitation at the Area 5 RWMS during 2012 is 11% below the average of 122.4 mm (4.82 in.). Water balance measurements indicate that evapotranspiration from the vegetated weighing lysimeter dries the soil and prevents downward percolation of precipitation more effectively than evaporation from the bare-soil weighing lysimeter. Automated vadose zone monitoring on Area 5 and Area 3 RWMS cell covers show no evidence of precipitation percolating through the cover to the waste. Moisture from precipitation did not percolate below 60 centimeters (cm) (2 feet [ft]) in the vegetated final cover on the U-3ax/bl disposal unit at the Area 3 RWMS, and moisture from precipitation and irrigation did not percolate below 45 cm (1.5 ft) on the 92-Acre Area final cover. Irrigation was applied to this cover for seed germination and plant growth. During 2012, there was no drainage through 2.4 meters (8 ft) of soil from the Area 3 drainage lysimeters that received only natural precipitation. Twenty percent of the applied precipitation and irrigation drained from the bare-soil drainage lysimeter that received 3 times natural precipitation. All 2012 monitoring data indicate that the Area 3 and Area 5 RWMSs are performing within expectations of the model and parameter assumptions for the facility PAs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of an Environmentally Acceptable Hydraulic Fluid

Hydroelectric plants operators like the United States Army Corps of Engineers seek their traditional petroleum-based fluids with environmentally acceptable hydraulic fluids (EAHF) to reduce their impact and liability related to spills and leakages to the water and environment. Artesion, Inc. and its sub-contractor Washington State University (WSU) sought to optimize WSU’s existing EAHF blend into an improved product that would demonstrate long-term stability while meeting the EAHF requirements of the EPA’s Vessel General Permit (VGP). Multiple rounds of Design of Experiments testing were performed from WSU’s base formulation, modifying mixing ratios to generate multiple test fluids. These fluids were then tested for hydraulic fluid properties. It was found that there was a significant tradeoff between oxidative stability and biodegradability; highly stable materials were not sufficiently biodegradable, while the highly biodegradable materials quickly failed in stability tests. After four rounds of Design of Experiments, AI and WSU had found a base fluid which met the VGP, but only had a Rotating Pressure Vessel Oxidative Test (RPVOT) of 284-minute RPVOT stability, far short of the 500-minute target that would be needed for hydroelectric plants. It was determined that WSU’s route had shown initial promise but needed more refinement to be able to produce an acceptable EAHF.

36 MATERIALS SCIENCE↗

A Statistical Analysis of Impact Ice Adhesion Strength Data Acquired with a Modified Lap Joint Test

Numerous methodologies have been utilized to measure the adhesion strength of impact ice, and the data reported in the literature varies significantly from method to method. In order to initiate an investigation to determine the cause of this disparity, a lap-joint shear test methodology that was recently developed was utilized in the Icing Research Tunnel at the NASA Glenn Research Center. Data was obtained while varying the temperature, test section velocity, liquid water content, and cloud droplet median volumetric diameter, among other parameters, over five campaigns. A new data set acquired using this new test method is presented. The results are analyzed with standard statistical methodologies and demonstrate a strong correlation between the apparent adhesion strength of ice and temperature, annealing time, and heating time. Observations during the test and analysis of the results suggest the presence of large residual stresses in the samples, which is in agreement with prior work. Due to the nature of the test methodology, and all known ice adhesion test methodologies, the measured, or apparent, adhesion strength is geometry dependent, a fact emphasized by the results presented here. The data was organized both cumulatively and independently by result code. Trends in the data are discussed in the context of causal physical mechanisms. The data shows the apparent adhesion strength was not linear with temperature, liquid water content, annealing time, and other variables. Short-term heating of the samples was shown to have negligible effect, and the apparent adhesion strength had a flat trend with velocity.

Ice Adhesion↗

To Cage or Not to Cage Seagrass; Is There Even a Question?

To Cage or Not to Cage Seagrass; Is There Even a Question? Loraé T. Simpson1, Morgan K. Gilligan1, Douglas M. Scheidt2 1Florida Oceanographic Society, Stuart, FL; 2Herndon Solutions Group/NEMCON, Kennedy Space Center, FL Contact email: lsimpson@floridaocean.org Diminished water quality has led to the decline of seagrasses and their associated ecosystem services in the Banana River Lagoon (BRL), resulting in increased restoration initiatives. Restoration success may be hindered by herbivory and the addition of herbivore exclusion devices may limit grazing stress on newly established seagrasses. These structures may alter sediment dynamics, influencing seagrass productivity. To test whether herbivore exclusion devices impact restoration success and sediment dynamics, we caged half of our seagrass restoration plots in the BRL. Treatments were monitored monthly for seagrass growth, and at three months for porewater nutrients, sediment bulk density, and carbon to nitrogen ratio. On average, caged plots had 87% more seagrass cover and 81% taller blades than control plots, highlighting the importance of caging newly transplanted seagrasses. There was no significant difference in porewater or sediment characteristics between treatments, suggesting that pedogensis and nutrient cycling need extended monitoring to capture changes in temporal scales.

Indian River Lagoon↗

To Cage or Not to Cage Seagrass; Is There Even a Question?

Diminished water quality has led to the decline of seagrasses and their associated ecosystem services in the Banana River Lagoon (BRL), resulting in increased restoration initiatives. Restoration success may be hindered by herbivory and the addition of herbivore exclusion devices may limit grazing stress on newly established seagrasses. These structures may alter sediment dynamics, influencing seagrass productivity. To test whether herbivore exclusion devices impact restoration success and sediment dynamics, we caged half of our seagrass restoration plots in the BRL. Treatments were monitored monthly for seagrass growth, and at three months for porewater nutrients, sediment bulk density, and carbon to nitrogen ratio. On average, caged plots had 87% more seagrass cover and 81% taller blades than control plots, highlighting the importance of caging newly transplanted seagrasses. There was no significant difference in porewater or sediment characteristics between treatments, suggesting that pedogensis and nutrient cycling need extended monitoring to capture changes in temporal scales.

Indian River Lagoon↗

Cementitious Grouts for ILW Encapsulation - Hydration and Continuity of Supply within the UK - 16184

In the UK the preferred route to disposal for the majority of intermediate level nuclear waste (ILW) streams is encapsulation within a cementitious matrix, accounting for 83% of waste conditioned to date (NDA, 2013). The method is well-defined and produces a waste package that is both chemically and physically stable, providing a multi-layered barrier to the release of the waste species contained within. Due to the process of treatment, facilitated via remote operation, it is necessary for the grouting matrices to meet strict performance limits in terms of their flow, setting time and avoidance of the formation of bleed water or segregation. To this end, the limits on composition of the anhydrous materials (a mixture of ordinary Portland cement [OPC] and blast furnace slag [BFS]) are tight to ensure conformity. Whilst these limits on composition are well understood, their impact upon grout hydration, and hence performance, is poorly defined. This study investigates the effects of modifying the physical and chemical composition of both the OPC and the BFS components of the matrix in order to identify the sensitivity or otherwise of the system to ensure that a continuity of supply is maintained. A number of techniques, scanning electron microscopy - image analysis (SEM-IA), chemical shrinkage (measured via dilatometry), isothermal conduction calorimetry (ICC), thermogravimetric analysis (TGA) and X-ray diffraction (XRD), have been applied to assess the rate and degree of hydration (DoH) of a range of grouts prepared with OPC and BFS with a range of chemical and physical compositions. This has been coupled with subsequent engineering performance testing, with additional analysis to understand the impact of a fire scenario within a storage or disposal facility, to provide an indication towards the resilience of the waste packages to a potential catastrophic event. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRITON: A Multi-GPU open source 2D hydrodynamic flood model

A new open source multi-GPU 2D flood model called TRITON is presented in this work. The model solves the 2D shallow water equations with source terms using a time-explicit first order upwind scheme based on an Augmented Roe's solver that incorporates a careful estimation of bed strengths and a local implicit formulation of friction terms. Here, the scheme is demonstrated to be first order accurate, robust and able to solve for flows under various conditions. TRITON is implemented such that the model effectively utilizes heterogeneous architectures, from single to multiple CPUs and GPUs. Different test cases are shown to illustrate the capabilities and performance of the model, showing promising runtimes for large spatial and temporal scales when leveraging the computer power of GPUs. Under this hardware configuration, communication and input/output subroutines may impact the scalability. The code is developed under an open source license and can be freely downloaded in https://code.ornl.gov/hydro/triton.

2D flood model↗

Validation of Computational Fluid Dynamics Simulations for Biological Performance Assessment in Hydropower units (Final Report)

The biological performance assessment (BioPA) toolset developed by Pacific Northwest National Laboratory (PNNL) estimates the relative biological performance of fish passage at a hydroelectric power turbine unit. The tool is based on the use of computational fluid dynamics (CFD) and fish biological response relationships. The recent release, BioPA-v3, is based on directly computed trajectory and collision of material Lagrangian particles using CFD simulation codes rather than the prior version that relies on Tecplot to compute streamtrace trajectories. Before modifying the toolset, a series of validation tests were performed at the various steps of modification in the toolset. Validation is a critical step of any numerical investigation that reflects the accuracy and reliability of the predicted results. It raises the confidence level of the user to use the modified version of the BioPA toolset. Several test cases were simulated and compared, where available, to observed data. The trajectory and collision of the small spherical and cylindrical particles in a water flume were compared to in-house experiments. The CFD predicted collision rate and flow field compared well with experimental observation for vane array and large cylinder as target bodies. Next, the CFD-predicted flow field and hydraulic performance of a laboratory-scale model of a Francis turbine was also successfully validated. Note that the trajectory of the particles is significantly affected by the flow field in such extreme conditions. In addition to the particle trajectories and flow field, the collision detection method employed in the CFD simulations was also successfully validated. The CFD predicted impact velocity, collision time, velocity, and trajectory of a sphere excellently matched with analytical value for a bouncing ball in the elastic collision. A similar approach was also tested and successfully validated for a collision of sphere with a 45° inclined plane. After successfully validating different cases, the BioPA toolset was modified to use direct output of the CFD prediction and the new version can be used in evaluating biological performance at hydroelectric turbines.

13 HYDRO ENERGY↗

CARETS: A prototype regional environmental information system. Volume 11: Potential usefulness of CARETS data for environmental impact assessment

The National Environmental Policy Act of 1969 requires that Federal agencies prepare environmental impact statements (EIS) for all proposed actions that significantly affect the quality of the environment. The EIS builds a predictive model of beneficial or adverse changes resulting from an action. Environmental impact statement preparation requires identification of environmental, social, and economic conditions likely to change and also requires prediction of intensity and spatial dimensions of changes. The Central Atlantic Regional Ecological Test Site (CARETS) project has produced land use data that can be of value for such assessment. To ascertain the types of proposed actions requiring EIS's, all EIS's prepared for proposed actions in the test site between January 1970 and June 1974 were reviewed. The actions were divided into seven categories: (1) construction of transportation and communication facilities; (2) construction of power plant, powerline, and fuel line facilities; (3) urban renewal, new town development projects, and multistory building construction; (4) construction of facilities for watershed protection and development;, (5) construction of waste treatment and disposal facilities (6) maintenance dredging, navigation improvements, and beach erosion control and replenishment projects; and (7) establishing or enhancing land and water conservation areas. Examples of actions from each category were selected for more detailed study. In view of the types of projects being proposed, an approach to environmental impact assessment using land use and water data as central inputs was recommended. The viability of such an approach as well as other approaches depends upon the availability of quantitative data such as those produced by the CARETS project.

Environmental impact assessment↗

Computational and Experimental Benchmarking for Transient Fuel Testing

In 2018 the Transient Reactor Test (TREAT) Facility was restarted. This now-operational facility brings back world-class transient fuel testing capabilities to the U.S. Among a number of parallel efforts prior to the TREAT Facility’s restart a Department of Energy (DoE) Integrated Research Project (IRP) was funded for the purpose of benchmarking the TREAT with several goals in mind: To produce a comprehensive evaluation of existing TREAT Facility neutronics data using the next generation reactor core neutronics codes in accordance with established guidelines per the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhEP). To perform a benchmark using ready-use computational fluid dynamics tools against that of a historically collected sodium loop experiment collected in the TREAT. To design, develop and test a new experimental thermal hydraulic system of a representative TREAT Facility water flow loop. And benchmark the data collected against that produced via RELAP5-3D and TRACE. To develop a comprehensive instrumentation plan for the TREAT Facility by benchmarking performing of advanced in-pile instruments in the Massachusetts Institute of Technology Research Reactor (MITR) and the TREAT. The integrated team brought together collaborating members from three universities including Oregon State University (OSU), the University of Michigan (UM), and Massachusetts Institute of Technology (MIT); three national laboratories, Idaho National Laboratory, Argonne National Laboratory (ANL), and Oak Ridge National Laboratory (ORNL); and two industry partners, TerraPower (TP) and Harris Thermal Transfer Products (HTTP). A brief summary of accomplishments resulting from this IRP includes two filed patents, more than 40 conference papers, two published benchmark reports through IRPhEP, a new representative thermal hydraulic test facility alike the in-pile PWR water flow loop for TREAT and the first advanced instruments tested within the TREAT core upon its restart. The papers presented herein were developed and provide a summary of the significant technical accomplishments which align with the four project’s objectives. The collaborators has significant support from countless parties including the operational and technical staff at TREAT to ensure that their outcomes most impactfully aligned with program needs. Lastly the collaborators would like to acknowledge the fiscal support of the DoE’s Office of Nuclear Energy under work package identification number NU-15-OR-OSU- 0701-01. This report contains selected papers from the Computational and Experimental Benchmarking for Transient Fuel Testing Integrated Research Project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantification of Residual Water in Spent Fuel Dry Storage Canisters Using Mass Spectrometry

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal, such as fuel degradation; cladding corrosion, embrittlement, or breaching; and the creation of a flammable environment via radiolysis of water. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents details on the quantification of residual water in the Advanced Drying Cycle Simulator (ADCS), an apparatus built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. The ADCS is outfitted with thermocouples to measure the thermal response of the ADCS to simulated decay heats and internal helium fill pressures relevant to commercial drying procedures. The ADCS is also instrumented with pressure transducers to measure the pressures and vacuum levels observed during simulated commercial drying. The most unique instrumentation used for quantifying residual water in the ADCS is a Hiden Analytical HPR-30 mass spectrometer (MS), which measures gas compositions of the ADCS internal free volume, based on partial pressures calculated from relative proportions of gas molecules detected by the MS. This report details the methodology used to implement MS measurements in quantifying residual water in the ADCS. This methodology includes the calibration of the HPR-30 MS to a Buck Research Instruments CR-4 chilled mirror hygrometer, which itself is calibrated to a NIST-traceable standard. Data collected by both the MS and the chilled mirror hygrometer from water/helium mixtures ranging from 150 to 500,000 ppmv water in helium were used to generate calibration curves, establishing a source of verification of MS measured water contents. Details regarding water content measurement uncertainties are included in this report, defining the accuracy and verifiability of the HPR-30 MS in measuring residual water content in simulated dry storage canister environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗