Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Time Averaged Pressure Measurement in Fundamentally Unsteady Pressure Gain Combustion Systems

Experimental results and analysis are presented on a technique for obtaining time averaged pressure in the harsh and highly unsteady environment of a pressure gain combustor. The technique utilizes a long, narrow, stand-off tube leading from the measurement point to a pressure transducer. The tube damps the fluctuations (which may result from strong shocks and/or detonations) and thermally isolates the transducer. The damping must be sufficient to ensure that net gasdynamic work exchange does not occur on the fluid in the stand-off tube, and it must be linear to insure that the time-averaged pressure at the transducer end is the same as that at the combustor end. The paper presents experimental and analytical results from two rigs which indicate that, using certain stand-off tube dimensions, these criteria are met. Physical rational for the tube dimensions (i.e., guidelines) are also presented.

detonation↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of scaled models in wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed Complementary Metal Oxide Superconductor (CMOS) cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed on the grid nodes of a user-defined patch. The effect of shot noise is reduced in the integrated pressure on the patch; however, the measurement of the aerodynamic pressure may also be attenuated by the decorrelation of the flow pressure field being measured. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF, a function of frequency, is defined as the ratio of the Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average PSD of the aerodynamic pressure on the grid nodes of the patch. In this paper, the JAAF is investigated for the integrated pressure on rectangular patches, whose edges are defined in the direction along the streamline or across the streamline. Based on the assumption that the surface pressure field can be described by the Corcos model, the closed-form formulas to compute the JAAFs of the integrated pressure on the discrete grid nodes of a rectangular patch and over the continuous area of a rectangular patch are derived respectively. It is shown that the JAAF of the integrated pressure over the continuous area of a rectangular patch is the limit of that on discrete nodes of the rectangular patch when the number of nodes in each row or column goes to infinity. The closed-form formulas of the JAAF derived in this paper, with estimated parameters of the model, are verified with the measurements of the uPSP and the conventional pressure transducer collected in the Space Launch System Ascent Unsteady Aerodynamics Test at NASA Ames Research Center in November 2017. The closed-form formulas of the JAAF of the integrated pressure on the rectangular patches, based on the Corcos model, provide an efficient method to estimate the attenuation of integration by the decorrelation of the flow pressure field and set references for the comparison of the spectrum of the integrated uPSP measurements and the conventional pressure transducer measurements. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities Portfolio Office.

acoustics↗

Joint Acceptance Attenuation Factor of Integrated Pressure with Unsteady Pressure-Sensitive Paint Measurements

The Unsteady Pressure-Sensitive Paint (uPSP) is widely used to measure the surface pressure of scaled models in wind tunnel tests. Compared to the conventional pressure transducers, uPSP has the advantage of high spatial resolution. With multiple high-speed Complementary Metal Oxide Superconductor (CMOS) cameras, the uPSP data collected with the camera pixels are mapped to the surface grid of the scaled model and converted to pressure. The shot noise is the dominant component of the noise in the uPSP measurement. The integrated pressure is usually computed on the grid nodes of a user-defined patch. The effect of shot noise is reduced in the integrated pressure on the patch; however, the measurement of the aerodynamic pressure may also be attenuated by the decorrelation of the flow pressure field being measured. This paper discusses the Joint Acceptance Attenuation Factor (JAAF) of the integrated pressure with uPSP measurements. The JAAF, a function of frequency, is defined as the ratio of the Power Spectral Density (PSD) of the integrated aerodynamic pressure on the patch to the average PSD of the aerodynamic pressure on the grid nodes of the patch. In this paper, the JAAF is investigated for the integrated pressure on rectangular patches, whose edges are defined in the direction along the streamline or across the streamline. Based on the assumption that the surface pressure field can be described by the Corcos model, the closed-form formulas to compute the JAAFs of the integrated pressure on the discrete grid nodes of a rectangular patch and over the continuous area of a rectangular patch are derived respectively. It is shown that the JAAF of the integrated pressure over the continuous area of a rectangular patch is the limit of that on discrete nodes of the rectangular patch when the number of nodes in each row or column goes to infinity. The closed-form formulas of the JAAF derived in this paper, with estimated parameters of the model, are verified with the measurements of the uPSP and the conventional pressure transducer collected in the Space Launch System Ascent Unsteady Aerodynamics Test at NASA Ames Research Center in November 2017. The closed-form formulas of the JAAF of the integrated pressure on the rectangular patches, based on the Corcos model, provide an efficient method to estimate the attenuation of integration by the decorrelation of the flow pressure field and set references for the comparison of the spectrum of the integrated uPSP measurements and the conventional pressure transducer measurements. The work described in this paper is a part of NASA’s development of a new state-of-the-art uPSP capability in production wind tunnels. Funding was provided by the NASA Aerosciences Evaluation and Test Capabilities Portfolio Office.

acoustics↗

Quantifying energy and mass transfer in crop canopies: sensors for measurement of temperature and air velocity

Here we report on the in situ performance of inexpensive, miniature sensors that have increased our ability to measure mass and energy fluxes from plant canopies in controlled environments: 1. Surface temperature. Canopy temperature measurements indicate changes in stomatal aperture and thus latent and sensible heat fluxes. Infrared transducers from two manufacturers (Exergen Corporation, Newton, MA; and Everest Interscience, Tucson, AZ, USA) have recently become available. Transducer accuracy matched that of a more expensive hand-held infrared thermometer. 2. Air velocity varies above and within plant canopies and is an important component in mass and energy transfer models. We tested commercially-available needle, heat-transfer anemometers (1 x 50 mm cylinder) that consist of a fine-wire thermocouple and a heater inside a hypodermic needle. The needle is heated and wind speed determined from the temperature rise above ambient. These sensors are particularly useful in measuring the low wind speeds found within plant canopies. 3. Accurate measurements of air temperature adjacent to plant leaves facilitates transport phenomena modeling. We quantified the effect of radiation and air velocity on temperature rise in thermocouples from 10 to 500 micrometers. At high radiation loads and low wind speeds, temperature errors were as large as 7 degrees C above air temperature.

NASA Program CELSS↗

Apparatus measures thermal conductivity of honeycomb-core panels

Overall thermal conductivity of honeycomb-core panels at elevated temperatures is measured by an apparatus with a heater assembly and a calibrated heat-rate transducer. The apparatus has space between the heater and transducer for insertion of a test panel and insulation.

Source record↗

Miniature telemetry system accurately measures pressure

Miniature, low power, telemetry system that can be used with commercially available strain gage pressure transducers accurately measures pressure with a small implantable pressure cell and transmitter. The system has been used to date only with pressure transducers, but the circuit is equally applicable to any measurement using a strain gage sensor.

Fryer, T. B.↗

Gas pressure in sealed electrochemical cells measured externally

Piezoresistive transducer measures gas pressure inside sealed secondary electrochemical cells without breaking the seal. This method is based on the observed fact that the force exerted by the cell faces on the clamp tightening them against the transducer is a function of the gas pressure inside the cell.

Sherfey, J. M.↗

Ultraminiature manometer-tipped cardiac catheter

Miniature diaphragm-type capacitance transducer capable of being mounted on the end of a cardiac catheter has been developed for measurement of intravascular pressures. The transducer can be inserted in small ducts /arteries and veins/ without disturbing the flow characteristics. It is very useful for making measurements in babies.

Coon, G. W.↗

Nonsteady flow-direction measurement

Nonsteady flow probe uses miniature pressure transducers mounted within probe support very close to tube inlets. Response speed depends on internal volume between tube inlet and pressure transducer location.

Krause, L. N.↗

Study to develop improved methods to detect leakage in fluid systems, phase 2

An ultrasonic contact sensor engineering prototype leak detection system was developed and its capabilities under cryogenic operations demonstrated. The results from tests indicate that the transducer performed well on liquid hydrogen plumbing, that flow and valve actuation could be monitored, and that the phase change from gaseous to liquid hydrogen could be detected by the externally mounted transducers. Tests also demonstrate the ability of the system to detect internal leaks past valve seats and to function as a flow meter. Such a system demonstrates that it is not necessary to break into welded systems to locate internal leaks.

Janus, J. C.↗

Hydrogen slush density reference system

A hydrogen slush density reference system was designed for calibration of field-type instruments and/or transfer standards. The device is based on the buoyancy principle of Archimedes. The solids are weighed in a low-mass container so arranged that solids and container are buoyed by triple-point liquid hydrogen during the weighing process. Several types of hydrogen slush density transducers were developed and tested for possible use as transfer standards. The most successful transducers found were those which depend on change in dielectric constant, after which the Clausius-Mossotti function is used to relate dielectric constant and density.

Weitzel, D. H.↗

State of the art: A review

Electronic devices and instruments currently used to track animals in order to determine their migratory and navigational behavior are discussed. Passive and active transducers in use for this purpose are described. The characteristics of the data received by the transducers and the equipment used to process the data are explained.

Busser, J. H.↗

A capacitive accelerometer suitable for telemetry

The design and development of a miniature 0.635 cm (0.25 in.) diameter capacitive accelerometer for use in free flight wind tunnel telemetry are presented. Instruments with full scale ranges from + or - 1 to + or - 200 g were constructed, calibrated, and used in several wind tunnel telemetry projects. Flat, high frequency response from 0 to 1000 Hz or more was obtained by employing the inherent damping and stiffness in the air film surrounding the diaphragm-type spring that supports the inertial mass of the accelerometer. Design features to achieve minimum off-axis sensitivity and temperature stability are discussed, and the design requirements for use of the transducer with telemetry systems are derived. A transducer capacitance change of 0.16 pF full scale gave excellent resolution and provided a frequency deviation of 0.75 MHz for a 100 MHz FM oscillator. Although the present design of the capacitive accelerometer was optimized by using units of 0.635 cm diameter, construction of experimental accelerometers as small as 0.36 cm (0.14 in.) diameter has demonstrated the feasibility of further miniaturization.

Coon, G. W.↗

Acoustic-emission signal-processing analog unit for locating flaws in large tanks

Technique monitors structural flaws in 105-in. diameter tanks. Tank surface is divided into many areas and each area is sectioned into 20 equilateral triangles that form icosahedron. Twelve transducers are equally positioned on tank surface at vertex of each triangle. Transducers monitor area for flaws by detecting any increase in acoustical activity.

Moskal, F. J.↗

Optical Production and Detection of Ultrasonic Waves in Metals for Nondestructive Testing

Ultrasonic waves were produced by striking the surface of a metal with the focused one-joule pulse of a Q-switched ruby laser. Rayleigh (surface) waves and longitudinal waves were detected with conventional transducers. Optical methods of detection were tested and developed. Rayleigh waves were produced with an oscillator and transducer. They were optically detected on curved polished surfaces, and on unpolished surfaces. The technique uses a knife edge to detect small angle changes of the surface as the wave pulse passes the illuminated spot. Optical flaw detection using pulse echo and attenuation is demonstrated.

Morrison, R. A.↗

Electro-optical processing of phased array data

An on-line spatial light modulator for application as the input transducer for a real-time optical data processing system is described. The use of such a device in the analysis and processing of radar data in real time is reported. An interface from the optical processor to a control digital computer was designed, constructed, and tested. The input transducer, optical system, and computer interface have been operated in real time with real time radar data with the input data returns recorded on the input crystal, processed by the optical system, and the output plane pattern digitized, thresholded, and outputted to a display and storage in the computer memory. The correlation of theoretical and experimental results is discussed.

Casasent, D.↗

A study of the local pressure field in turbulent shear flow and its relation to aerodynamic noise generation

Work during the period of this report has been in three areas: (1) pressure transducer error analysis, (2) fluctuating velocity and pressure measurements in the NASA Lewis 6-inch diameter quiet jet facility, and (3) measurement analysis. A theory was developed and experimentally verified to quantify the pressure transducer velocity interference error. The theory and supporting experimental evidence show that the errors are a function of the velocity field's turbulent structure. It is shown that near the mixing layer center the errors are negligible. Turbulent velocity and pressure measurements were made in the NASA Lewis quiet jet facility. Some preliminary results are included.

Jones, B. G.↗