Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Dosimetric properties of an amorphous-silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT

Dosimetric properties of an amorphous-silicon electronic portal imaging device (EPID) operated in a real-time acquisition mode were investigated. This mode will be essential for time-resolved dose verification of dynamic (sliding window) intensity modulated radiation therapy (IMRT) and intensity modulated arc radiation therapy (arc-IMRT). The EPID was used in continuous acquisition mode (i.e., ''cine'' mode) where individual sequential image frames are acquired in real time. The properties studied include dose linearity, reproducibility of response, and image stability. Results of using the continuous acquisition mode with several example treatments including dynamic IMRT, arc treatment, and single-arc-IMRT are compared to results using the well-studied integrated acquisition mode (i.e., ''frame averaging'' or ''IMRT'' mode). Real-time EPID response was also compared to real-time ion-chamber data for selected points in the deliveries. The example treatment deliveries in both continuous and integrated acquisition modes were converted to arbitrary EPID dose units via a calibration field. The summation of all acquired continuous mode images was compared using percentage dose difference to the single image acquired in the integrated mode using in-field pixels only (defined as those pixels >10% of maximum, in-field signal). Using the continuous acquisition mode, the EPID response was not linear with dose. It was found that the continuous mode dose response corresponded approximately to dropping one image per acquisition session. Reproducibility of EPID response to low monitor units (MUs) was found to be poor but greatly improved with increasing MU. Open field profiles were found to be stable in the cross-plane direction but required several frames to become stable in the in-plane direction. However, both of these issues are clinically insignificant due to arc-IMRT deliveries requiring relatively large monitor units (>100 MU). Analysis of the five IMRT, arc, and arc-IMRT tests revealed that all examples compared to within 2% of maximum dose for more than 95% of in-field pixels. The continuous acquisition mode is suited to time-resolved dosimetry applications including arc-IMRT and dynamic IMRT, giving comparable dose results to the well-studied integrated acquisition mode, although caution should be used in low MU applications. Time-resolved EPID dose information also compared well to time-resolved ion-chamber measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterizing core and edge turbulence regimes with fluctuation imaging diagnostics in Wendelstein 7-X

Two density fluctuation imaging systems, phase contrast imaging (PCI) and gas puff imaging (GPI) measure spatially resolved density fluctuations with high time resolution throughout the core plasma (PCI) and in the scrape-off layer (GPI) of the Wendelstein 7-X (W7-X) stellarator. Both systems combined give a comprehensive overview of overall fluctuation levels, spectral properties such as their distribution in frequency and wavenumber space as well as their spatial distribution. These tools are used to assess changes in density turbulence in three representative discharges that transition into stable divertor detachment by different strategies (impurity seeding, density ramping and power starvation). Several general trends are identified when the radiated power fraction is systematically increased: In the plasma edge, the line emission observed by GPI shifts radially inward with a drop in electron temperature, and normalized intensity fluctuation profiles follow this inward shift. Skewness and kurtosis of these edge fluctuations are reduced, indicating a reduction of large intermittent transport events, and poloidal phase velocities decrease in magnitude. These observations are consistent with a reduced power input into the plasma edge and a general reduction of turbulent activity. Core density fluctuation levels remain nearly constant in the impurity seeding scenario, indicating that detachment does not significantly impact turbulence there. However, a strong reduction in the dominant outboard fluctuation phase velocity is observed that deviates from the previous interpretation of neoclassical radial electric field changes, showing that the core plasma is not completely unaffected. In the density ramp and power starvation scenarios, undesirable and irregular large-scale events arise clearly in both diagnostic systems as the radiative fraction is increased. Impurity seeding therefore seems to be a promising strategy on W7-X to achieve detachment without significantly altering core turbulence, especially when targeting a specific operating point in core density and heating power.

Wendelstein 7-X↗

THE RADIO CONTINUUM STRUCTURE OF CENTAURUS A AT 1.4 GHz

A 45 deg{sup 2} radio continuum imaging campaign of the nearest radio galaxy, Centaurus A, is reported. Using the Australia Telescope Compact Array and the Parkes 64 m radio telescope at 1.4 GHz, the spatial resolution of the resultant image is {approx}600 pc ({approx}50''), resolving the {approx}>500 kpc giant radio lobes with approximately five times better physical resolution compared to any previous image, and making this the most detailed radio continuum image of any radio galaxy to date. In this paper, we present these new data and discuss briefly some of the most interesting morphological features that we have discovered in the images. The two giant outer lobes are highly structured and considerably distinct. The southern part of the giant northern lobe naturally extends out from the northern middle lobe with uniformly north-streaming emission. The well known northern loop is resolved into a series of semi-regular shells with a spacing of approximately 25 kpc. The northern part of the giant northern lobe also contains identifiable filaments and partial ring structures. As seen in previous single-dish images at lower angular resolution, the giant southern lobe is not physically connected to the core at radio wavelengths. Almost the entirety of the giant southern lobe is resolved into a largely chaotic and mottled structure which appears considerably different (morphologically) to the diffuse regularity of the northern lobe. We report the discovery of a vertex and a vortex near the western boundary of the southern lobe, two striking, high surface brightness features that are named based on their morphology and not their dynamics (which are presently unknown). The vortex and vertex are modeled as reaccelerated lobe emission due to shocks from the active galactic nucleus itself or from the passage of a dwarf elliptical galaxy through the lobe. Preliminary polarimetric and spectral index studies support a plasma reacceleration model and could explain the origin of the Faraday rotation structure detected in the southern lobe. In addition, there are a series of low surface brightness wisps detected around the edges of both the giant lobes.

79 ASTRONOMY AND ASTROPHYSICS↗

Tomographic Femtosecond X-Ray Diffractive Imaging

A method is proposed for obtaining three simultaneous projections of a target from a single radiation pulse, which also allows the relative orientation of successive targets to be determined. The method has application to femtosecond x-ray diffraction, and does not require solution of the phase problem. We show that the principal axes of a compact charge-density distribution can be obtained from projections of its autocorrelation function, which is directly accessible in diffraction experiments. The results may have more general application to time resolved tomographic pump-probe experiments and time-series imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Megahertz-rate shock-wave distortion cancellation via phase conjugate digital in-line holography

Abstract Holography is a powerful tool for three-dimensional imaging. However, in explosive, supersonic, hypersonic, cavitating, or ionizing environments, shock-waves and density gradients impart phase distortions that obscure objects in the field-of-view. Capturing time-resolved information in these environments also requires ultra-high-speed acquisition. To reduce phase distortions and increase imaging rates, we introduce an ultra-high-speed phase conjugate digital in-line holography (PCDIH) technique. In this concept, a coherent beam passes through the shock-wave distortion, reflects off a phase conjugate mirror, and propagates back through the shock-wave, thereby minimizing imaging distortions from phase delays. By implementing the method using a pulse-burst laser setup at up to 5 million-frames-per-second, time-resolved holograms of ultra-fast events are now possible. This technique is applied for holographic imaging through laser-spark plasma-generated shock-waves and to enable three-dimensional tracking of explosively generated hypersonic fragments. Simulations further advance our understanding of physical processes and experiments demonstrate ultra-high-speed PCDIH techniques for capturing dynamics.

Science & Technology - Other Topics↗

Phase transitions in freeze-dried systems - quantification using in situ synchrotron X-ray diffractometry

The purpose is: (1) To develop a synchrotron X-ray diffraction (SXRD) method to monitor phase transitions during the entire freeze-drying cycle. Aqueous sodium phosphate buffered glycine solutions with initial glycine to buffer molar ratios of 1:3 (17:50 mM), 1:1 (50 mM) and 3:1 were utilized as model systems. (2) To investigate the effect of initial solute concentration on the crystallization of glycine and phosphate buffer salt during lyophilization. Phosphate buffered glycine solutions were placed in a custom-designed sample cell for freeze-drying. The sample cell, covered with a stainless steel dome with a beryllium window, was placed on a stage capable of controlled cooling and vacuum drying. The samples were cooled to -50 C and annealed at -20 C. They underwent primary drying at -25 C under vacuum until ice sublimation was complete and secondary drying from 0 to 25 C. At different stages of the freeze-drying cycle, the samples were periodically exposed to synchrotron X-ray radiation. An image plate detector was used to obtain time-resolved two-dimensional SXRD patterns. The ice, {beta}-glycine and DHPD phases were identified based on their unique X-ray peaks. When the solutions were cooled and annealed, ice formation was followed by crystallization of disodium hydrogen phosphate dodecahydrate (DHPD). In the primary drying stage, a significant increase in DHPD crystallization followed by incomplete dehydration to amorphous disodium hydrogen phosphate was evident. Complete dehydration of DHPD occurred during secondary drying. Glycine crystallization was inhibited throughout freeze-drying when the initial buffer concentration (1:3 glycine to buffer) was higher than that of glycine. A high-intensity X-ray diffraction method was developed to monitor the phase transitions during the entire freeze-drying cycle. The high sensitivity of SXRD allowed us to monitor all the crystalline phases simultaneously. While DHPD crystallizes in frozen solution, it dehydrates incompletely during primary drying and completely during secondary drying. The impact of initial solute concentration on the phase composition during the entire freeze-drying cycle was quantified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase correlation imaging of unlabeled cell dynamics

We present phase correlation imaging (PCI) as a novel approach to study cell dynamics in a spatially-resolved manner. PCI relies on quantitative phase imaging time-lapse data and, as such, functions in label-free mode, without the limitations associated with exogenous markers. The correlation time map outputted in PCI informs on the dynamics of the intracellular mass transport. Specifically, we show that PCI can extract quantitatively the diffusion coefficient map associated with live cells, as well as standard Brownian particles. Due to its high sensitivity to mass transport, PCI can be applied to studying the integrity of actin polymerization dynamics. Our results indicate that the cyto-D treatment blocking the actin polymerization has a dominant effect at the large spatial scales, in the region surrounding the cell. We found that PCI can distinguish between senescent and quiescent cells, which is extremely difficult without using specific markers currently. We anticipate that PCI will be used alongside established, fluorescence-based techniques to enable valuable new studies of cell function.

42 ENGINEERING↗

Radiative Properties of Implosions of Stainless Steel Wire Arrays with Application to Astrophysics

Experiments with different stainless steel (SS) wire loads were performed on the 1 MA Zebra Z-pinch generator at University of Nevada, Reno. The wire array loads consisted of 7.6 {mu}m SS wires and had 10 wires for the planar wire array with an interwire gap of 1 mm and 8 wires for the cylindrical wire array of a 16 mm diameter. In addition, a single-wire experiment with a 25 {mu}m SS wire was carried out. The different wire loads were used to provide a broader spectrum of plasma conditions. Time-integrated and time-gated x-ray images, as well as time-integrated, spatially-resolved and spatially-integrated x-ray spectra, were collected and analyzed. Both K-shell and L-shell radiation were recorded using LiF and KAP crystal spectrometers, respectively. Non-LTE kinetic models of Fe and Ni are employed to derive plasma parameters. For axially resolved L-shell spectra, the resulting electron temperatures are between 230 and 300 eV (higher near the cathode) and electron densities vary from 10{sup 19} to 10{sup 20} cm{sup -3} dependent on the load. The advantage of using Z-pinch plasmas for astrophysical applications is highlighted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DIFFRACTION-LIMITED VISIBLE LIGHT IMAGES OF ORION TRAPEZIUM CLUSTER WITH THE MAGELLAN ADAPTIVE SECONDARY ADAPTIVE OPTICS SYSTEM (MagAO)

We utilized the new high-order (250-378 mode) Magellan Adaptive Optics system (MagAO) to obtain very high spatial resolution observations in ''visible light'' with MagAO's VisAO CCD camera. In the good-median seeing conditions of Magellan (0.''5-0.''7), we find MagAO delivers individual short exposure images as good as 19 mas optical resolution. Due to telescope vibrations, long exposure (60 s) r' (0.63 {mu}m) images are slightly coarser at FWHM = 23-29 mas (Strehl {approx}28%) with bright (R < 9 mag) guide stars. These are the highest resolution filled-aperture images published to date. Images of the young ({approx}1 Myr) Orion Trapezium {theta}{sup 1} Ori A, B, and C cluster members were obtained with VisAO. In particular, the 32 mas binary {theta}{sup 1} Ori C{sub 1} C{sub 2} was easily resolved in non-interferometric images for the first time. The relative positions of the bright trapezium binary stars were measured with {approx}0.6-5 mas accuracy. We are now sensitive to relative proper motions of just {approx}0.2 mas yr{sup -1} ({approx}0.4 km s{sup -1} at 414 pc)-this is a {approx}2-10 Multiplication-Sign improvement in orbital velocity accuracy compared to previous efforts. For the first time, we see clear motion of the barycenter of {theta}{sup 1} Ori B{sub 2} B{sub 3} about {theta}{sup 1} Ori B{sub 1}. All five members of the {theta}{sup 1} Ori B system appear likely to be a gravitationally bound ''mini cluster'', but we find that not all the orbits can be both circular and co-planar. The lowest mass member of the {theta}{sup 1} Ori B system (B{sub 4}; mass {approx}0.2 M{sub Sun }) has a very clearly detected motion (at 4.1 {+-} 1.3 km s{sup -1}; correlation = 99.9%) w.r.t. B{sub 1}. Previous work has suggested that B{sub 4} and B{sub 3} are on long-term unstable orbits and will be ejected from this ''mini cluster''. However, our new ''baseline'' model of the {theta}{sup 1} Ori B system suggests a more hierarchical system than previously thought, and so the ejection of B{sub 4} may not occur for many orbits, and B{sub 3} may be stable against ejection in the long-term. This ''ejection'' process of the lowest mass member of a ''mini cluster'' could play a major role in the formation of low-mass stars and brown dwarfs.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature distributions and gradients in laser-heated plasmas relevant to magnetized liner inertial fusion

We present two-dimensional temperature measurements of magnetized and unmagnetized plasma experiments performed at Z relevant to the preheat stage in magnetized liner inertial fusion. The deuterium gas fill was doped with a trace amount of argon for spectroscopy purposes, and time-integrated spatially resolved spectra and narrow-band images were collected in both experiments. The spectrum and image data were included in two separate multiobjective analysis methods to extract the electron temperature spatial distribution T e ( r , z ) . The results indicate that the magnetic field increases T e , the axial extent of the laser heating, and the magnitude of the radial temperature gradients. Comparisons with simulations reveal that the simulations overpredict the extent of the laser heating and underpredict the temperature. Temperature gradient scale lengths extracted from the measurements also permit an assessment of the importance of nonlocal heat transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-Resolved Thomson Scattering on Laboratory Plasma Jets

In this study, Thomson scattering measurements were performed on plasma jets created from a 15-μm-thick radial Al foil load on a 1-MA pulsed power machine. The laser used for these measurements has a maximum energy of 10 J at 526.5 nm. Using the full energy, however, significantly heats the 5x10¹⁸ cm⁻³ jet by inverse bremsstrahlung, creating a density bubble in the jet. To measure the evolving plasma parameters of this laser-heated jet, a streak camera was used to record the scattered spectrum, resulting in the sub-ns time-resolved Thomson scattering. Analysis of the streak camera image showed that the electron temperature of the jet was about 25 eV prior to the laser pulse. The laser then heated the plasma to 80-100 eV within about 2 ns. The electron temperature then stabilized for about 0.5 ns prior to falling at the end of the laser pulse. Jets made from a radial Ti foil showed more heating by the laser than the Al jets, going from 50 to over 150 eV, and heating was detected even when only 1 J of laser energy was used. Also, the ion-acoustic peaks in the scattered spectrum from the Ti jets were significantly narrower than those from Al jets, a result of several possible differences in the plasma created from these two materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and Theoretical Needs for the JWST Early Release Science Program on Radiative Feedback from Massive Stars (PDRs4ALL): III. A Quantum Chemistry Perspective

Massive stars disrupt their natal molecular cloud material by dissociating molecules, ionizing atoms and molecules, and heating the gas and dust. These processes drive the evolution of interstellar matter in our Galaxy and throughout the Universe from the era of vigorous star formation at z=1-3 to the present day. Much of this interaction occurs in Photo- Dissociation Regions (PDRs) where far-ultraviolet photons of these stars create a largely neutral, but warm region of gas and dust. PDR emission dominates the IR spectra of starforming galaxies and provides a unique tool to study the physical and chemical processes that are relevant for inter- and circumstellar media including diffuse clouds, molecular cloud and protoplanetary disk surfaces, and starburst galaxies. The ERS program ID1288 is dedicated to provide template data as well as data processing and analysis tools for PDRs. To this end, it will observe the Orion Bar, the proto-typical PDR situated in the nearby Orion Nebula, using NIRSpec IFU, MIRI IFU, and NIRCAM and MIRI imaging. These observations will, for the first time, spatially resolve and perform a tomography of the PDR, revealing the individual IR spectral signatures from the key zones and sub-regions within the ionized gas, the PDR, and the molecular cloud. Quantum chemistry can be used to determine molecular data such as ionization potentials, chemical reaction rates, electronic spectra, dissociation energies, channels, and branching ratios, etc. These are often used in synergy with experiment to take advantage of the strengths of each approach. An area of active research is modeling the infrared (IR) emission spectra produced by PAH molecules, including the effects of anharmonicity. This will be important in the interpretation of JWST data which will yield higher-resolution spectral data compared to Spitzer or ISO. Quantum chemistry methods can compute accurate anharmonic IR absorption spectra of PAH molecules up to about 25 C atoms, and the results have been benchmarked against high-resolution experimental spectra. These feed into a quantum Monte Carlo (QMC) approach to generate temperature-dependent anharmonic IR emission spectra and then used to generate fully anharmonic cascade emission IR spectra of PAH molecules -- the very type of spectra that JWST will observe. Work continues to extend these methods to larger PAH molecules. We will discuss the current state of this work, as well as

Timothy Lee↗

Standoff Infrared Measurements of Chemical Plume Dynamics in Complex Terrain Using a Combination of Active Swept-ECQCL Laser Spectroscopy with Passive Hyperspectral Imaging

Chemical plume detection and modeling in complex terrain present numerous challenges. We present experimental results from outdoor releases of two chemical tracers (sulfur hexafluoride and Freon-152a) from different locations in mountainous terrain. Chemical plumes were detected using two standoff instruments collocated at a distance of 1.5 km from the plume releases. A passive long-wave infrared hyperspectral imaging system was used to show time- and space-resolved plume transport in regions near the source. An active infrared swept-wavelength external cavity quantum cascade laser system was used in a standoff configuration to measure quantitative chemical column densities with high time resolution and high sensitivity along a single measurement path. Both instruments provided chemical-specific detection of the plumes and provided complementary information over different temporal and spatial scales. The results show highly variable plume propagation dynamics near the release points, strongly dependent on the local topography and winds. Effects of plume stagnation, plume splitting, and plume mixing were all observed and are explained based on local topographic and wind conditions. Measured plume column densities at distances ~100 m from the release point show temporal fluctuations over ~1 s time scales and spatial variations over ~1 m length scales. The results highlight the need for high-speed and spatially resolved measurement techniques to provide validation data at the relevant spatial and temporal scales required for high-fidelity terrain-aware microscale plume propagation models.

47 OTHER INSTRUMENTATION↗

Progress of Mechanical Design of Nanopositioning Stages at the Advanced Photon Source

Here, we present the upgraded Advanced Photon Source (APS) will be optimized to produce hard X-rays with a high degree of spatial coherence, and will exceed the capabilities of today's synchrotrons by two to three orders of magnitude in brightness and coherent flux in the hard X-ray range [1]. It will particularly benefit techniques such as advanced X-ray nanoprobes for nanoscale imaging, nanospectroscopy, and nanodiffraction. It will also benefit coherent diffractive imaging and ptychography with spatial resolution approaching atomic length scales and permitting time-resolved studies [2]. Meanwhile, many beamlines will be upgraded to take advantage of the smaller emittance for nanofocusing and nano-scale imaging. All of these methodologies will need novel precision X-ray instruments, including nanopositioning stages, to make full use of the new diffraction-limited storage ring capabilities. Although commercial companies produce a wide variety of state-of-the-art nanopositioning stages, there are specific scientific research goals that cannot be addressed adequately with commercial products. In these cases, it is necessary to push the engineering limits and develop in-house, customized nanopositioning stages to meet the scientific research goals. In this technical report, we outline the progress of mechanical designs of APS-developed nanopositioning instrumentation for synchrotron radiation instrumentation (SRI) applications. First, we describe flexure stages that use both overconstrained weak-link mechanisms and commercial flexure pivots. Finally, we describe a new, highly stable stage system for hard X-ray microscopy applications, called the Velociprobe.

47 OTHER INSTRUMENTATION↗

Spatially resolved polarization swings in the supermassive binary black hole candidate OJ 287 with first Event Horizon Telescope observations

We present the first Event Horizon Telescope 1.3 mm observations of the supermassive binary black hole candidate OJ 287. The observations achieved an unprecedented angular resolution of 18 μas and reveal significant structural and polarization variability over just five days, marking the shortest timescale on which such changes have been directly imaged in this source. The inner jet exhibits a twisted ridgeline structure, with features displaying apparent superluminal motions up to about 22 c. The linear polarization maps reveal three main polarized features whose electric-vector position angles (EVPAs) change substantially over the time span of our observations, including a component with a radial polarization consistent with being produced by a recollimation shock. Most notably, we directly resolved two innermost jet components whose EVPAs rotate in opposite directions. The faster component, moving at 2.4 ± 0.9 μas/day (17.4 ± 6.5 c), exhibits counterclockwise EVPA swings of roughly 3.7° per day, while the slower component, with a proper motion of 1.4 ± 0.3 μas/day (10.2 ± 2.2 c), rotates clockwise at approximately 2.5° per day. Previous studies inferred helical magnetic fields in AGN jets from time-resolved or integrated polarization variability but lacked the angular resolution to directly image this effect. Our results provide spatially resolved evidence that a helical magnetic field threads the jet’s collimation and acceleration zone, ruling out models based on the superposition of unresolved components. Our analysis suggests that propagating shocks interact with a Kelvin–Helmholtz plasma instability, illuminating different phases of the helical magnetic field and producing the observed polarization spatial and temporal variability. Moreover, our model naturally accounts for the more rapid polarization rotation observed in the faster moving component. Our model predicts even more rapid swings in polarization, which could be tested with future observations featuring a more densely sampled time coverage.

OJ 287↗

A Qualitative Investigation of Selected Infrared Flow Visualization Image Processing Techniques

The deployment and integration of high-sensitivity infrared cameras in a transonic wind tunnel testenvironment has resulted in a unique capability to image aerodynamic phenomena in real-time. Multi-camera infrared flow visualization data systems are now routinely utilized at the NASA Ames Unitary Plan Wind Tunnel. The small flow-induced temperature gradients on the surface of the wind tunnel test article coupled with the high bit-depth of the infrared camera sensor makes the processing of the image data critically important. An image processing routine must enhance features of interest with minimal artifacts. Additionally, the production wind tunnel test environment demands that these processed images are made available in a real-time, automatic fashion. Therefore, any image processing routine must be computationally economical and enhance the image data with minimal input from a human operator. The following seeks to qualitatively explore selected image processing techniques by assessing their effectiveness to resolve flow features on a wind tunnel test article. A multi-scale contrast enhancement technique is discussed as well as a new implementation of a multi-scale, non-interpolated adaptive histogram equalization. Finally, a novel method is introduced that demonstrates the ability to resolve flow features imaged on bare-steel test articles possessing low emissivity.This method makes use of dynamic mode decomposition and discrete-time filtering to separate the background reflections that dominate low emissivity surfaces from the aerodynamic driven surface temperature gradients.This process will be shown to resolve the onset of boundary layer transition on a bare metal wing as well as identify and resolve hidden features in the image data. While the implementation of this technique is very preliminary it demonstrates the potential to extend the application of infrared flow-visualization within the wind tunnel test environment.

Image Processeing↗

Highly Resolved Mapping of NO 2 Vertical Column Densities From GeoTASO Measurements Over a Megacity and Industrial Area During the KORUS-AQ Campaign

The Korea–United States Air Quality (KORUS-AQ) campaign is a joint study between the United States National Aeronautics and Space Administration (NASA) and the South Korea National Institute of Environmental Research (NIER) to monitor megacity and transboundary air pollution around the Korean Peninsula using airborne and ground-based measurements. Here, tropospheric nitrogen dioxide (NO 2 ) slant column density (SCD) measurements were retrieved from Geostationary Trace and Aerosol Sensor Optimization (GeoTASO) L1B data during the KORUS-AQ campaign (2 May to 10 June 2016). The retrieved SCDs were converted to tropospheric vertical column densities using the air mass factor (AMF) obtained from a radiative transfer calculation with trace gas profiles and aerosol property inputs simulated with the Community Multiscale Air Quality (CMAQ) model and surface reflectance data obtained from the Moderate Resolution Imaging Spectroradiometer (MODIS). For the first time, we examine highly resolved (250 m × 250 m resolution) tropospheric NO 2 over the Seoul and Busan metropolitan regions and the industrial region of Anmyeon. We reveal that the maximum NO 2 vertical column densities (VCDs) were 4.94×10 16 and 1.46×10 17 molec. cm −2 at 09:00 and 15:00 LT over Seoul, respectively, 6.86×10 16 and 4.89×10 16 molec. cm −2 in the morning and afternoon over Busan, respectively, and 1.64×10 16 molec. cm −2 over Anmyeon. The VCDs retrieved from the GeoTASO airborne instrument were correlated with those obtained from the Ozone Monitoring Instrument (OMI) (r=0.48), NASA's Pandora Spectrometer System (r=0.91), and NO 2 mixing ratios obtained from in situ measurements (r=0.07 in the morning, r=0.26 in the afternoon over the Seoul, and r>0.56 over Busan). Based on our results, GeoTASO is useful for identifying NO 2 hotspots and their spatial distribution in highly populated cities and industrial areas.

Gyo-Hwang Choo↗

Electron Ghost Imaging

Here in this paper, we report a demonstration of electron ghost imaging. A digital micromirror device directly modulates the photocathode drive laser to control the transverse distribution of a relativistic electron beam incident on a sample. Correlating the structured illumination pattern to the total sample transmission then retrieves the target image, avoiding the need for a pixelated detector. In our example, we use a compressed sensing framework to improve the reconstruction quality and reduce the number of shots compared to raster scanning a small beam across the target. Finally, compressed electron ghost imaging can reduce both acquisition time and sample damage in experiments for which spatially resolved detectors are unavailable (e.g., spectroscopy) or in which the experimental architecture precludes full frame direct imaging.

43 PARTICLE ACCELERATORS↗