Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

A high temperature superconductivity communications flight experiment

The proposed high temperature superconductivity (HTSC) millimeter-wave communications flight experiment from the payload bay of the Space Shuttle Orbiter to the Advanced Communications Technology Satellite (ACTS) in geosynchronous orbit is described. The experiment will use a Ka-band HTSC phased array antenna and front-end electronics to receive a downlink communications signal from the ACTS. The discussion covers the system configuration, a description of the ground equipment, the spacecraft receiver, link performance, thermal loading, and the superconducting antenna array.

Ngo, P.↗

Preliminary design of a radiator shading device for a lunar outpost

The National Aeronautics and Space Administration is designing a thermal control system for an outpost to be placed permanently on the Moon. One of the functions of the thermal control system is to reject waste heat, which can be accomplished through a radiator. At the lunar equator and during the lunar midday, an unshaded radiator absorbs more heat than it rejects. This problem can be solved by using a shading device to reduce radiation incident on the radiator. The design team was asked to develop concepts for reducing the radiation incident on the radiator and for deploying the radiator and shade system for a 10 kW and a 25 kW heat rejection system. The design team was also asked to develop the best concepts into preliminary design. From the several alternatives developed by the design team, the best one was selected using a decision matrix. Preliminary design of the best concept include support structure, stress analyses, and thermal performance. In addition, the team developed ideas for removing lunar dust from the shading device. The final design solution consisted of a winged radiator shading system with a rail support structure and a scissors mechanism for deployment. The total radiator area required was calculated to be 389 sq m for the 10 kW heat rejection system and 973 sq m for the 25 kW heat rejection system.

Barron, Carlos↗

Contamination on LDEF: Sources, distribution, and history

An introduction to contamination effects observed on the Long Duration Exposure Facility (LDEF) is presented. The activities reported are part of Boeing's obligation to the LDEF Materials Special Investigation Group. The contamination films and particles had minimal influence on the thermal performance of the LDEF. Some specific areas did have large changes in optical properties. Films also interfered with recession rate determination by reacting with the oxygen or physically shielding underlying material. Generally, contaminant films lessen the measured recession rate relative to 'clean' surfaces. On orbit generation of particles may be an issue for sensitive optics. Deposition on lenses may lead to artifacts on photographic images or cause sensors to respond inappropriately. Particles in the line of sight of sensors can cause stray light to be scattered into sensors. Particles also represent a hazard for mechanisms in that they can physically block and/or increase friction or wear on moving surfaces. LDEF carried a rather complex mixture of samples and support hardware into orbit. The experiments were assembled under a variety of conditions and time constraints and stored for up to five years before launch. The structure itself was so large that it could not be baked after the interior was painted with chemglaze Z-306 polyurethane based black paint. Any analysis of the effects of molecular and particulate contamination must account for a complex array of sources, wide variation in processes over time, and extreme variation in environment from ground to launch to flight. Surface conditions at certain locations on LDEF were established by outgassing of molecular species from particular materials onto adjacent surfaces, followed by alteration of those species due to exposure to atomic oxygen and/or solar radiation.

Pippin, Gary↗

Radiative cryogenic cooler for the pressure modulator IR radiometer

An existing operational low-earth-orbit radiative cooler is being upgraded for use on the Mars Observer polar-orbiting mission, using the Landsat Thematic Mapper cooler as a basis for upgrading. Significant improvements were achieved in the design of the thermal performance and vibration endurance, and in the mass minimization design. The cooler provides about 18 mW of useful refrigeration power in Mars orbit at its equilibrium operating temperature. The detector operating temperature for the worst-case orbital environment is about 73 K.

Kuyper, Donald J.↗

Thermal design optimization of a segmented GFRP primary reflector for a submillimeter telescope

Results are presented of a thermal design optimization study of the segmented GFRP primary reflector of the earth-orbiting Submillimeter Imager and Line Survey telescope. The paper examines the thermal requirements of the primary reflector and the thermal environment of the telescope and describes the thermal design of the primary reflector. Particular attention is given to the geometric math model and the thermal math model of the telescope. A summary for the steady-state thermal performance of the optimized design is presented, showing that the optimized design has reduced, by an order of magnitude, structural spatial temperature gradients, which were earlier shown to be the most significant obstacle in maintaining the required telescope figure accuracy.

Tsuyuki, Glenn T.↗

A liquid-helium-cooled absolute reference cold load for long-wavelength radiometric calibration

Design, radiometric and thermal performance, and operation of a large diameter (78 cm) liquid-helium-cooled blackbody absolute reference cold load (CL) for the calibration of microwave radiometers is described. CL provides an absolute calibration near the liquid-helium (LHe) boiling point, with total uncertainty in the radiometric temperature of less than 30 mK over the 2.5-23 cm wavelength operating range. CL was used at several wavelengths at the South Pole, Antarctica and the White Mountain Research Center, California. Results show that, for the instruments operated at 20-, 12-, 7.9-, and 4.0 cm wavelength at the South Pole, the total corrections to the LHe boiling-point temperature (about 3.8 K) were 48 +/-23, 18 +/-10, 10 +/-18, and 15 +/-mK.

Bensadoun, Marc↗

Design of the cryogenic system for the SAFIRE instrument

One of the primary goals of the NASA Mission to Planet Earth is to improve understanding of the ozone chemistry of the atmosphere over an extended period of time. The Spectroscopy of the Atmosphere using Far Infrared Emission (SAFIRE) instrument is being developed to conduct, for the first time, global measurements of the key ozone chemistry constituents in both the mid- and far-infrared spectral regions. Such remote, long-term observations are made possible by the recent development of compact long-life hybrid cryogenic dewars which are necessary to cool the sensitive detectors to the 3-4 K range. The success of this hybrid concept is based on the use of long-life Stirling cycle cryocoolers to intercept parasitic heat from the internal radiation shields of the superfluid helium dewar. Extensive system trade studies are required to optimize the mass, power, and lifetime of these space-borne cryogenic systems. The SAFIRE Cryogenic Subsystem is described, including the thermal performance trades leading to the chosen system configuration and the important dewar/cryocooler interface issues.

Lee, J. H.↗

Subscale hot-fire testing of a formed platelet liner

To investigate low-cost options for fabricating main combustion chambers, formed platelet liners are being developed. The savings in manufacturing time and cost associated with platelet liners are accompanied by promising thermal advantages, such as lower-wall temperatures and increased cycle life. A subscale liner was tested by NASA at Marshall Space Flight Center (MSFC) to demonstrate its thermal performance. Testing to date has provided chamber pressures up to 2524 psia, while a maximum chamber pressure of 2700 psia is planned. In general, the liner has remained in good condition and performed well, with only minor areas of localized roughening. Data from this subscale test program is being used to develop a full size chamber for testing on a Space Shuttle Main Engine at MSFC in 1994.

Elam, Sandra K.↗

SRB thermal curtain design support

The objective of the program during this time period was to evaluate candidate materials that could be used to design an improved Solid Rocket Motor (SRM) Aft Skirt Thermal Curtain (ASTC). The ASTC is a flexible, high temperature, cloth and insulation composite that is used to protect the hardware located inside the aft skirt of the shuttle solid rocket booster. The current ASTC consists of nine layers of insulating materials and is 2.58 inches thick. The ASTC is made up of twenty four segments. The segments are hand sewn together during installation on the aft skirt. The weight of the current ASTC is approximated at about six hundred pounds. This weight does not include the weight of the mounting hardware and ties required to install the twenty four ASTC segments (which is significant). The current effort entailed measuring the thermophysical properties of six candidate materials (quartz, S glass, and Kevlar woven into nominal 0.25 inch thick layers by angle interlock and polar-weave) and then using these properties in a computer program to predict the thermal performance of various curtain configurations subjected to an SRM heat flux.

Dixon, Carl A.↗

A comparison of TSS and TRASYS in form factor calculation

As the workstation and personal computer become more popular than a centralized mainframe to perform thermal analysis, the methods for space vehicle thermal analysis will change. Already, many thermal analysis codes are now available for workstations, which were not in existence just five years ago. As these changes occur, some organizations will adopt the new codes and analysis techniques, while others will not. This might lead to misunderstandings between thermal shops in different organizations. If thermal analysts make an effort to understand the major differences between the new and old methods, a smoother transition to a more efficient and more versatile thermal analysis environment will be realized.

Golliher, Eric↗

Hypersonic engine seal development at NASA Lewis Research Center

NASA Lewis Research Center is developing advanced seal concepts and sealing technology for advanced combined cycle ramjet/scramjet engines being designed for the National Aerospace Plane (NASP). Technologies are being developed for both the dynamic seals that seal the sliding interfaces between articulating engine panels and sidewalls, and for the static seals that seal the heat exchanger to back-up structure interfaces. This viewgraph presentation provides an overview of the candidate engine seal concepts, seal material assessments, and unique test facilities used to assess the leakage and thermal performance of the seal concepts.

Steinetz, Bruce M.↗

Outgassing of solid material into vacuum thermal insulation spaces

Many cryogenic storage tanks use vacuum between inner and outer tank for thermal insulation. These cryogenic tanks also use a radiation shield barrier in the vacuum space to prevent radiation heat transfer. This shield is usually constructed by using multiple wraps of aluminized mylar and glass paper as inserts. For obtaining maximum thermal performance, a good vacuum level must be maintained with the insulation system. It has been found that over a period of time solid insulation materials will vaporize into the vacuum space and the vacuum will degrade. In order to determine the degradation of vacuum, the rate of outgassing of the insulation materials must be determined. Outgassing rate of several insulation materials obtained from literature search were listed in tabular form.

Wang, Pao-Lien↗

Calorimetric evaluation of commercial Ni-MH cells and charges

The test objectives are to evaluate the electrical and thermal performance of commercial Ni-MH cells and to evaluate the effectiveness of commercial charge control circuits. The ultimate design objectives are to determine which cell designs are most suitable for scale-up and to guide the design of future Shuttle and Station based battery chargers.

Darcy, Eric C.↗

Supplemental multilayer insulation research facility

The Supplemental Multilayer Insulation Research Facility (SMIRF) provides a small scale test bed for conducting cryogenic experiments in a vacuum environment. The facility vacuum system is capable of simulating a Space Shuttle launch pressure profile as well as providing a steady space vacuum environment of 1.3 x 10(exp -4) Newton/sq meter (1 x 10(exp -6) torr). Warm side boundary temperatures can be maintained constant between 111 K (200 R) and 361 K (650 R) using a temperature controlled shroud. The shroud can also simulate a typical lunar day-night temperature profile. The test hardware consists of a cryogenic calorimeter supported by the lid of the vacuum chamber. A 0.45 cu meter (120 gallon) vacuum jacketed storage/supply tank is available for conditioning the cryogen prior to use in the calorimeter. The facility was initially designed to evaluate the thermal performance of insulation systems for long-term storage in space. The facility has recently been used to evaluate the performance of various new insulation systems for LH2 and LN2 ground storage dewars.

Dempsey, P. J.↗

Computing Operating Characteristics Of Bearing/Shaft Systems

SHABERTH computer program predicts operating characteristics of bearings in multibearing load-support system. Lubricated and nonlubricated bearings modeled. Calculates loads, torques, temperatures, and fatigue lives of ball and/or roller bearings on single shaft. Provides for analysis of reaction of system to termination of supply of lubricant to bearings and other lubricated mechanical elements. Valuable in design and analysis of shaft/bearing systems. Two versions of SHABERTH available. Cray version (LEW-14860), "Computing Thermal Performances Of Shafts and Bearings". IBM PC version (MFS-28818), written for IBM PC-series and compatible computers running MS-DOS.

Moore, James D.↗

Flight Test Results for the HST Orbital Systems Test (HOST) Capillary Pump Loop Cooling System

The Near Infrared Camera and Multi Object Spectrometer (NICMOS) was installed in the Hubble Space Telescope (MST) in February 1997. Shortly thereafter, the instrument experienced a thermal short in its solid nitrogen dewar system which will significantly shorten the instrument's useful life. A reverse Brayton cycle mechanical refrigerator will be installed during the Third Servicing Mission (SM3) to provide cooling for the instrument, and thereby extend its operations. A Capillary Pump Loop (CPL) and radiator system was designed, built and tested to remove up to 500 watts of heat from the mechanical cryocooler and its associated electronics. The HST Orbital Systems Test (HOST) platform was flown on the Space Shuttle Discovery (STS-95) as a flight demonstration of the cryocooler system, CPL control electronics, and the CPL/Radiator. This paper will present the flight test results and thermal performance of the CPL system in detail.

Buchko, M.↗

Large Scale Testing of a Foam/Multilayer Insulation Thermal Control System (TCS) for Cryogenic Upper Stages

The development of high energy cryogenic upper stages is essential for the efficient delivery of large payloads to various destinations envisioned in future programs. A key element in such upper stages is cryogenic fluid management (CFM) advanced development/technology. Due to the cost of and limited opportunities for orbital experiments, ground testing must be employed to the fullest extent possible. Therefore, a system level test bed termed the Multipurpose Hydrogen Test Bed (MHTB), which is representative in size and shape (3 meter diameter by 3 meter long with a volume of 18 cubic meters) of a fully integrated space transportation vehicle liquid hydrogen propellant tank has been established. To date, upper stage studies have often baselined the foam/multilayer insulation (FMLI) combination concept; however, hardware experience with the concept is minimal and was therefore selected for the MHTB. The foam element (isofoam SS-1 171 with an average thickness of 3.5 centimeters) is designed to protect against ground hold/ascent flight environments, and allows for the use of a dry nitrogen purge as opposed to the more complex/heavy helium purge subsystem normally required with MLI in cryogenic applications. The MLI (45 layers of Double Aluminized Mylar with Dacron spacers) provides protection in the vacuum environment of space and is designed for an on-orbit storage period of 45 days. Several unique features were incorporated in the MLI concept and included: variable density MLI (reduces weight and radiation losses by changing the layer density), larger but fewer DAM perforations for venting during ascent to orbit (reduces radiation losses), and roll wrap installation of the MLI with a commercially established process to lower assembly man-hours and reduce seam heat leak. Thermal performance testing of the MHTB TCS was conducted during three test series conducted between September 1995 and May 1996. Results for the ground hold portion of the tests were as expected producing an average heat leak of 63 WattS/M2 at an average foam surface temperature of 170 K. The results of the simulated orbit hold test interval produced heat leaks ranging from 0.085 to 0.22 Watts/squareM at warm boundary temperatures of 164K and 305K, respectively. When compared to the performance for a traditional MLI system, a 60% reduction in orbital heat leak or boiloff was measured. Overall, the MHTB TCS demonstrated satisfactory performance for all mission phases required of a cryogenic upper stage.

Hastings, Leon↗