Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “The Pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Efficient 15 N hyperpolarization of [ 15 N 3 ]metronidazole antibiotic via spin-relayed pulsed SABRE-SHEATH

Signal Amplification by Reversible Exchange in SHield Enables Alignment Transfer to Heteronuclei (SABRE-SHEATH) is an NMR hyperpolarization technique that relies of the simultaneous exchange of parahydrogen and a to-be-hyperpolarized molecule on the metal center of a polarization-transfer catalyst in a microtesla magnetic field. Until recently, this method has been understood to perform hyperpolarization by establishing level anti-crossings between the nuclear spins of the parahydrogen derived hydrides (acting as a source of hyperpolarization) and those of the substrate. Recently, the application of highly non-intuitive pulse sequences (comprising pulses of microtesla DC fields) was predicted to hyperpolarize nuclear spins more efficiently than the canonical (static-field) SABRE-SHEATH approach. Here we show that by employing a basic “on-off” pulse sequence of rectangular microtesla pulses, it is possible to improve the hyperpolarization efficiency for SABRE-SHEATH of [ 15 N 3 ]metronidazole, an FDA-approved antibiotic (in non-enriched and non-hyperpolarized form) and potential hypoxia sensing molecule. Specifically, we demonstrate that 15N polarization of 18.5 % can be obtained in 80 s of parahydrogen bubbling parahydrogen through a solution containing 20 mM [ 15 N 3 ]metronidazole. In practice, (1.32 ± 0.14)-fold improvements in P 15N was obtained with the pulsed method described here compared to static field technique variant. These results show that pulsed SABRE-SHEATH was successfully applied to 15 N-labeled biologically relevant molecule. Moreover, we also demonstrate that although the pulsed SABRE-SHEATH sequence was designed for polarization transfer from parahydrogen derived hydrides to the metronidazole’s 15 N catalyst-binding site, all three 15 N sites of [ 15 N 3 ]metronidazole attained the hyperpolarized state. This spin-relayed polarization transfer becomes possible due to the 15 N relay network established by their spin-spin J-couplings. The feasibility of the spin-relayed polarization transfer is demonstrated here for the first time for pulsed SABRE-SHEATH (as opposed to the static-field SABRE-SHEATH reported previously) and it paves the way to broad applicability of the technique.

Hyperpolarization↗

Mitigating Damage to Hybrid Perovskites Using Pulsed-Beam TEM

Using a pulsed-beam transmission electron microscope, we discover a reduction in damage to methylammonium lead iodide (MAPbI3) as compared to conventional beams delivered at the same dose rates. For rates as low as 0.001 e·Å –2 ·s –1 , we find up to a 17% reduction in damage at a total dose of 10 e·Å –2 . We systematically study the effects of number of electrons in each pulse and the duration between pulse arrival. Damage increases for both, though the number of electrons per pulse has a larger effect. A crossover is identified, where a pulsed beam causes more damage than a conventional one. Although qualitatively similar to previous findings, the degree to which damage is reduced in MAPbI3 is less than that observed for other materials (e.g., C36H74), supporting the hypothesis that the effects are material- and damage-mechanism-dependent. Despite this, the observation here of damage reduction for relatively large electron packets (up to 200 electrons per pulse) suggests that MAPbI3 is in fact less susceptible to irradiation than C36H74, which may be related to reported self-healing effects. This work provides insights into damage processes and durability in hybrid perovskites and also illustrates the viability of using pulsed-beam TEM to explore the associated molecular-level routes to degradation, analogous to laser-accelerated energetic pulsed electron beams and the study of damage to biomolecules, cells, and tissues in radiobiology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Statistical Analysis of Trans‐Ionospheric Pulse Pairs and Inferences on Their Characteristics

Trans-ionospheric pulse pairs (TIPPs), first observed in 1993, are signatures of in-cloud lightning discharges observed by satellite-based broadband very high frequency (VHF) receivers. It has been definitively shown that TIPPs are the space-based signatures of compact intracloud discharges (CIDs), and that the associated pair of pulses that comprise a TIPP result from the direct VHF pulse from the discharge, followed by a pulse reflected from the Earth's surface. However, the ratio of the peak amplitudes of these two pulses can vary widely, with the second pulse often having considerably higher peak amplitude than the first. This observation has not been satisfactorily explained. Using data collected from geostationary orbit by the Radio Frequency Sensor (RFS) and matched to locations reported by the Global Lightning Dataset (GLD360), we assemble the largest database to date of 76,348 TIPPs with associated location, altitude, and amplitude ratio of the two pulses in the TIPP. We show that the amplitude ratio of TIPPs is strongly correlated to the altitude of the associated discharges and the geometry of the source location with respect to the Earth's surface and the receiver. These observations strongly suggest that the difference in amplitude of the two pulses is driven by a nondipole radiated beam pattern that is dependent on the polarity of the CID, velocity of the current wavefront, and viewing angle.

58 GEOSCIENCES↗

Control of Early Flame Kernel Growth by Multi-Wavelength Laser Pulses for Enhanced Ignition

The present contribution examines the impact of plasma dynamics and plasma-driven fluid dynamics on the flame growth of laser ignited mixtures and shows that a new dual-pulse scheme can be used to control the kernel formation process in ways that extend the lean ignition limit. We do this by performing a comparative study between (conventional) single-pulse laser ignition (λ = 1064 nm) and a novel dual-pulse method based on combining an ultraviolet (UV) pre-ionization pulse (λ = 266 nm) with an overlapped near-infrared (NIR) energy addition pulse (λ = 1064 nm). We employ OH* chemiluminescence to visualize the evolution of the early flame kernel. For single-pulse laser ignition at lean conditions, the flame kernel separates through third lobe detachment, corresponding to high strain rates that extinguish the flame. In this work, we investigate the capabilities of the dual-pulse to control the plasma-driven fluid dynamics by adjusting the axial offset of the two focal points. In particular, we find there exists a beam waist offset whereby the resulting vorticity suppresses formation of the third lobe, consequently reducing flame stretch. With this approach, we demonstrate that the dual-pulse method enables reduced flame speeds (at early times), an extended lean limit, increased combustion efficiency, and decreased laser energy requirements.

42 ENGINEERING↗

Monte Carlo Simulations of Microchannel Plate Detectors II: Pulsed Voltage Results

This paper is part of a continuing study of straight-channel microchannel plate (MCP)–based x-ray detectors. Such detectors are a useful diagnostic tool for two-dimensional, time-resolved imaging and time-resolved x-ray spectroscopy. To interpret the data from such detectors, it is critical to develop a better understanding of the behavior of MCPs biased with subnanosecond voltage pulses. The subject of this paper is a Monte Carlo computer code that simulates the electron cascade in a MCP channel under an arbitrary pulsed voltage, particularly those pulses with widths comparable to the transit time of the electron cascade in the MCP under DC voltage bias. We use this code to study the gain as a function of time (also called the gate profile or optical gate) for various voltage pulse shapes, including pulses measured along the MCP. In addition, experimental data of MCP behavior in pulsed mode are obtained with a short-pulse UV laser. Comparisons between the simulations and experimental data show excellent agreement for both the gate profile and the peak relative sensitivity along the MCP strips. We report that the dependence of relative gain on peak voltage increases in sensitivity in pulsed mode when the width of the high-voltage waveform is smaller than the transit time of cascading electrons in the MCP.

Kruschwitz, Craig A.↗

Extraction of negative ions from pulsed electronegative capacitively coupled plasmas

Charge buildup during plasma etching of dielectric features can lead to undesirable effects, such as notching, bowing, and twisting. Pulsed plasmas have been suggested as a method to achieve charge-free plasma etching. In particular, electronegative plasmas are attractive as the collapse of the plasma potential during the after-glow period of pulsed capacitively coupled plasmas (CCPs) can allow for extraction of negative ions into the feature. The extraction of negative ions in the after-glow of pulsed CCPs sustained in CF{sub 4} containing gas mixtures is computationally investigated. In this paper, the consequences of pulse frequency and gas chemistry on negative ion flux to the wafer are discussed. A low negative ion flux to the wafer was observed only in the late after-glow period of low pulse frequencies. The negative ion flux was found to significantly increase with the addition of highly electronegative gases (such as thermally attaching Cl{sub 2}) even at a high pulse frequency of 10 kHz. As the production of negative ions during the after-glow diminishes, alternative strategies to enhance the flux were also pursued. The flux of negative ions was found to increase by the addition of a pulsed dc voltage on the top electrode that is 180 Degree-Sign out-of-phase with the rf pulse.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A long-pulse repetitive operation magnetically insulated transmission line oscillator

The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of silicon and indium gallium arsenide photodiodes as direct timing detectors for pulsed x-ray systems

Benchtop pulsed x-ray systems are commonly used to record dynamic material data on the order of nanoseconds, but pulse timing is often difficult to accurately determine. This study demonstrates that commercially available photodiodes can be used effectively for direct x-ray pulse detection without the need for visible light scintillators. X-ray pulses from four commercially available flash x-ray systems were quantified using one silicon and two indium gallium arsenide (InGaAs) photodiodes. The measured InGaAs pulse durations were strongly dependent on radiation dose in the non-linear operating regime, so the photodiodes were shielded to operate below the 2.5 V non-linear regime threshold. The average pulse duration and pulse arrival time jitter of the photodiodes for each x-ray source were within several nanoseconds with the exception of two sets of measurements that were affected by low instrument sensitivity and electrical noise. These results show that InGaAs photodiodes can be used as effective and repeatable stand-alone timing diagnostics for x-ray pulses as short as 20 ns or less.

47 OTHER INSTRUMENTATION↗

Field ionization of Rydberg atoms in a single-cycle pulse

Here, we study the ionization of Rydberg atoms in a single-cycle-pulse electric field based on both classical and quantum calculations. The ionization-probability curve exhibits a “ripple” structure as a function of the pulse duration and the field amplitude. These ripple structures are found to be dependent on the angular distribution of the initial state. A large electron-emission asymmetry is observed, and the ionized electron is almost completely emitted to one side of the atom except when the pulse length is roughly one Rydberg period. In both the long-pulse and the short-pulse regimes, larger electron energy can be expected from the ionization of lower-lying Rydberg states, matching the observation in a recent experiment [S. Li and R. R. Jones, Phys. Rev. Lett. 112, 143006 (2014)]. This trend is closely related to the electron-emission asymmetry associated with the field-direction change in a single-cycle pulse. The possible implications of the different energy transfer in a single-cycle pulse from that in a multicycle pulse are also discussed briefly for the strong-field ionization of the ground atomic state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Schemes for generation of isolated attosecond pulses of pure circular polarization

Here, we propose and analyze two schemes capable of generating isolated attosecond pulses of pure circular polarization, based on results of numerical simulations. Both schemes utilize the generation of circularly polarized high-order-harmonics by crossing two circularly polarized counter-rotating pulses in a noncollinear geometry. Our results show that in this setup isolation of a single attosecond pulse can be achieved either by restricting the driver pulse duration to a few cycles or by temporally delaying the two crossed driver pulses. We further propose to compensate the temporal walk-off between the pulses across the focal spot and increasing the conversion efficiency by using angular spatial chirp to provide perfectly matched pulse fronts. The isolation of pure circularly polarized attosecond pulses, along with the opportunity to select their central energy and helicity in the noncollinear technique, opens new perspectives from which to study ultrafast dynamics in chiral systems and magnetic materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Unifying femtosecond and picosecond single-pulse magnetic switching in Gd-Fe-Co

Many questions are still open regarding the physical mechanisms behind the magnetic switching in Gd-Fe-Co alloys by single optical pulses. Phenomenological models suggest a femtosecond scale exchange relaxation between sublattice magnetization as the driving mechanism for switching. The recent observation of thermally induced switching in Gd-Fe-Co by using both several picosecond optical laser pulse as well as electric current pulses has questioned this previous understanding. This has raised the question of whether or not the same switching mechanics are acting at the femtosecond and picosecond scales. In this work, we aim at filling this gap in the understanding of the switching mechanisms behind thermal single-pulse switching. To that end, we have studied experimentally thermal single-pulse switching in Gd-Fe-Co alloys, for a wide range of system parameters, such as composition, laser power, and pulse duration. We provide a quantitative description of the switching dynamics using atomistic spin dynamics methods with excellent agreement between the model and our experiments across a wide range of parameters and timescales, ranging from femtoseconds to picoseconds. Furthermore, we find distinct element-specific damping parameters as a key ingredient for switching with long picosecond pulses and argue that switching with pulse durations as long as 15 ps is possible due to a low damping constant of Gd. Our findings can be easily extended to speed up dynamics in other contexts where ferrimagnetic Gd-Fe-Co alloys have been already demonstrated to show fast and energy-efficient processes, e.g., domain-wall motion in a track and spin-orbit torque switching in spintronics devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical design of the Short Pulse Soft X-ray Spectroscopy beamline at the Advanced Photon Source

The Short Pulse X-ray facility planned for the Advanced Photon Source (APS) upgrade will provide two sectors with photon beams having picosecond pulse duration. The Short Pulse Soft X-ray Spectroscopy (SPSXS) beamline will cover the 150–2000 eV energy range using an APS bending magnet. SPSXS is designed to take full advantage of this new timing capability in addition to providing circular polarized radiation. Since the correlation between time and electron momentum is in the vertical plane, the monochromator disperses in the horizontal plane. The beamline is designed to maximize flux and preserve the time resolution by minimizing the number of optical components. The optical design allows the pulse duration to be varied from 1.5 to 100 ps full width at half-maximum (FWHM) without affecting the energy resolution, and the resolution to be changed with minimal effect on the pulse duration. More than 10 9 photons s -1 will reach the sample with a resolving power of 2000 and a pulse duration of ~2 ps for photon energies between 150 and 1750 eV. The spot size expected at the sample position will vary with pulse duration and exit slit opening. At 900 eV and at a resolving power of 2000 the spot will be ~10 µm × 10 µm with a pulse duration of 2.3 ps FWHM.

47 OTHER INSTRUMENTATION↗

Spatiotemporal optical pulse transformation by a resonant diffraction grating

The diffraction of a spatiotemporal optical pulse by a resonant diffraction grating is considered. The pulse diffraction is described in terms of the signal (the spatiotemporal incident pulse envelope) passage through a linear system. An analytic approximation in the form of a rational function of two variables corresponding to the angular and spatial frequencies has been obtained for the transfer function of the system. A hyperbolic partial differential equation describing the general form of the incident pulse envelope transformation upon diffraction by a resonant diffraction grating has been derived from the transfer function. A solution of this equation has been obtained for the case of normal incidence of a pulse with a central frequency lying near the guided-mode resonance of a diffraction structure. The presented results of numerical simulations of pulse diffraction by a resonant grating show profound changes in the pulse envelope shape that closely correspond to the proposed theoretical description. The results of the paper can be applied in creating new devices for optical pulse shape transformation, in optical information processing problems, and analog optical computations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Encoding the complete electric field of an ultraviolet ultrashort laser pulse in a near-infrared nonlinear-optical signal

We introduce a variation on the cross-correlation frequency-resolved optical gating (XFROG) technique that uses a near-infrared (NIR) nonlinear-optical signal to characterize pulses in the ultraviolet (UV). Using a transient-grating XFROG beam geometry, we create a grating using two copies of the unknown UV pulse and diffract a NIR reference pulse from it. We show that, by varying the delay between the UV pulses creating the grating, the UV pulse intensity-and-phase information can be encoded into a NIR signal. We also implemented a modified generalized-projections phase-retrieval algorithm for retrieving the UV pulses from these spectrograms. We performed proof-of-principle measurements of chirped pulses and double pulses, all at 400 nm. This approach should be extendable deeper into the UV and potentially even into the extreme UV or x-ray range.

47 OTHER INSTRUMENTATION↗

Using double pulse laser ablation in air to enhance the strength of laser-driven shocks

In the process of multi-pulse laser ablation, inter-pulse delay time, Δ t , is known to be an important parameter for maximizing ablation efficiency as well as impulse imparted to the target. In this work, using photon Doppler velocimetry, we show that for single pairs of colinear pulses (1064 nm, 8 ns, ∼ 60 J cm -2 per pulse) in air, the peak free surface velocity of the back surface of an aluminum target (125 µm thick) is increased, by a factor of nearly 3, when Δ t = 10 microseconds, compared with both pulses arriving simultaneously (Δ t = 0). Fast imaging of the ablation process suggests this enhancement is due to rarefaction of the contiguous air in the passage of the leading shock produced by ablation, which then in turn allows a larger fraction of the energy of the second pulse to reach the target surface. This interpretation is strengthened by additional experiments in which the two pulses do not overlap on the target surface, but the shock strength is nevertheless enhanced. Given a fixed energy budget this work suggests a prescription for maximizing laser-driven shock strength by judicious choice of inter-pulse delay.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

In situ characterization of two unknown ultrashort laser pulses using four-wave mixing in gas

Accurate characterization of two ultrashort laser pulses is of great interest in many ultrafast pump-probe experiments. We demonstrate a method based on four-wave mixing (FWM) in a gas which could be easily implemented into many existing pump-probe setups with minimal modifications for accurate, in situ characterization of both unknown pulses. This technique is tested on pairs of unknown pulses at wavelengths of 400/800 nm, and 266/400 nm. We measured the spectrogram of the pulse generated through FWM of the two unknown pulses by scanning the delay between two unknown pulses. The retrieval algorithm converges to accurately predict the intensity and the phase profiles of both unknown pulses with a trace error of < 1% and the accuracy is verified using an independent pulse characterization device.

Nambu, Noa (ORCID:0000000197303400)↗

femto-PIXAR: a self-supervised neural network method for reconstructing femtosecond X-ray free electron laser pulses

X-ray Free Electron Lasers (X-FELs) operate in a wide range of lasing configurations for a broad variety of scientific applications at ultrafast time-scales such as structural biology, materials science, and atomic and molecular physics. Shot-by-shot characterization of the X-FEL pulses is crucial for analysis of many experiments as well as tuning the X-FEL performance. However, for the weak pulses found in advanced configurations, e.g. those needed for coherent, two-pulse studies of quantum materials, there is no current method for reliably resolving pulse profiles. Here we show that a physics-based U-net model can reconstruct the individual pulse power profiles for sub-picosecond pulse separation without the need for simulations. Using experimental data from weak X-FEL pulse pairs, we demonstrate we can learn the pulse characteristics on a shot-by-shot basis when conventional methods fail.

43 PARTICLE ACCELERATORS↗

Energy scaling beyond the gas ionization threshold with divided-pulse nonlinear compression

Here, we demonstrate how pulse energy in hollow-core fiber can be scaled beyond gas-ionization limitations using divided-pulse nonlinear compression. With one pulse, ionization limits our fiber’s pulse energy to 2.7-mJ output at an input of 4 mJ. By dividing to four low-energy pulses before the fiber, we eliminated the ionization and scaled the pulse energy 2.5× to 6.6 mJ at an input energy of 10 mJ. Larger energy scaling is possible, as our maximum pulse energy has not reached the new gas ionization threshold. Our results motivate applying the method to state-of-the-art systems for large pulse energy scaling without prohibitive system size increases.

47 OTHER INSTRUMENTATION↗