Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Containerless high temperature property measurements by atomic fluorescence

Laser induced fluorescence (LIF) techniques for containerless study of high temperature processes and material properties was studied. Gas jet and electromagnetic levitation and electromagnetic and laser heating techniques are used with LIF in earth-based containerless high temperature experiments. Included are the development of an apparatus and its use in the studies of (1) chemical reactions on Al2O3, molybdenum, tungsten and LaB6 specimens, (2) methods for noncontact specimen temperature measurement, (3) levitation jet properties and (4) radiative lifetime and collisional energy transfer rates for electronically excited atoms.

Schiffman, R. A.↗

Plasma Guns for Magnetized Fuel Targets for PJMIF

In plasma jet driven magneto-inertial fusion (PJMIF) an array of discrete supersonic plasma jets is used to form a spherically imploding plasma liner, which then compresses a magnetized plasma target to fusion conditions. With funding from ARPA-E’s ALPHA program and from Strong Atomics LLC, HyperJet Fusion Corp and HyperV Technologies Corp. previously developed the plasma guns required for an experimental demonstration of the plasma liner formation part of the concept. A 36-gun demonstration of an imploding spherical plasma liner is currently underway on the PLX facility at Los Alamos National Laboratory. This present project addresses the next step required for a complete PJMIF concept, i.e. developing the magnetized plasma target. We proposed to form the target by stagnating a number of magnetized plasma jets in the center of the target chamber. This is accomplished by adding a bias field coil to the plasma liner gun to form a magnetized plasma jet. This experimental development took place at HyperJet in a geometry replicating the bias field environment that will be seen on a PLX port so the results are directly transferrable to the PLX experiment. The objective of this effort was the technical development and characterization of a new magnetized plasma jet using a high-performance, high momentum flux, contoured-gap coaxial plasma gun appropriate for use on the next stage of the PLX experiment. Electromagnetic modeling of the coil indicated the coil was best placed around the aluminum tubes of the gun transmission line, rather than around the chamber port as originally proposed. This maximized field strength in the breech and yielded much better flux linkage between gun electrodes. A 30-turn coil was ultimately implemented, allowing long pulses that could diffuse through the metal walls on the timescale of interest. \machtwo modeling predicted that less capacitance in the main PFN could potentially improve plasma jet velocities due to better matching of the current to the smaller plasma mass and the existing electrode contour designed to suppress blowby. This proved true, as testing showed markedly improved performance when the original 600uF bank was reduced to 400uF. A number of diagnostics were built and/or upgraded in order to characterize the plasma jets, inluding laser interferomtery for density, photodiodes for velocity, Bdot probes for magnetic field measurements, a Triple probe for temperature measurements, and spectroscopy for impurity content. A plasma gun with the 30-turn magnet coil installed, a 70% reduction in gas valve plenum volume, and a 33% reduction in main PFN capacitance produced a dense, high velocity, well magnetized plasma jet. We met or exceeded virtually all of the plasma jet parameter goals. Peak velocity of 135 km/s exceeded the 100 km/s goal by 35%, while the peak density of over 1.0x10 15 cm -3 was 3.3 times the goal of >3.0x10 14 cm -3 . Shot-to-shot repeatability is excellent, with a jitter of less than 300ns observed on the arrival fronts of the photodiode signals from one shot to the next. Average plasma jet lengths of 33cm (at 120km/s) were slightly longer than the 20cm goal, but jets as short as 11.8cm were observed at 135km/s. Mass is much higher than the targeted goal, averaging 106ug per shot compared to 20ug. The magnetic field is still a bit lower than desired, with a maximum to date of ~811G, compared to the goal of 1000G. Average values, though, were typically in the 300-450G range, when measured further downstream after some expected in flight decay. Temperature measurements are still a work in progress. Increasing the B field and completing temperature measurements will be continued on into the ongoing BETHE project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of the inter-species power balance in JET plasmas

Most auxiliary heating methods provide heating to more than one particle species (electrons, ions, impurities) in a fusion plasma. This can lead to substantial temperature differences between species, depending on conditions such as heating power to the different species and collisionality, with temperature differences between species limited by inter-species thermal equipartition and transport. The analysis of the steady-state electron-ion and impurity-ion power balances presented in this paper are used for consistency-checking experimental ion and electron temperature measurements and for inferring the main ion temperature from measured impurity temperatures. As ion temperature measurements by charge exchange spectroscopy (CXS) based on impurity ions have become more difficult and time-consuming since the installation of the ITER-like wall (ILW) with Be and W PFC's, knowing the maximum sustainable temperature difference between ions and electrons, |T i -T e | allows rejecting erroneous measurements. It also obviates the need for an ion temperature measurement, if an electron temperature measurement is available and |T i - T e | cannot be larger than the combined errors of the underlying measurements. A power balance analysis is also required for estimating the errors of the ion and electron heat fluxes prior to any species-resolved transport analysis. The ion-impurity temperature differences are usually found to be small due to strong thermal equipartition between ion species. However, they can approach 10% in JET-ILW low density, high power discharges, such the ones under development for a future JET deuterium–tritium campaign (Joffrin et al 2019 Nucl. Fusion). This has a generally small, but not always negligible effect on the calculation of fusion reaction rates, which depend on main ion temperatures. An important outcome of this analysis is that temperature differences between impurity species are always much smaller than between the impurities and hydrogenic species and can usually be neglected. The article presents two methods for calculating the impurity-to-main ion temperature ratio. Finally, this analysis leads to a method for the reconstruction ion temperature profiles from ion temperature data available at only one or a small number of spatial locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Depth-Selective Diagnostics of Thermal Barrier Coatings Incorporating Thermographic Phosphors

Thermographic phosphors have been previously demonstrated to provide effective non- contact, emissivity-independent surface temperature measurements. Because of the translucent nature of thermal barrier coatings (TBCs), thermographic-phosphor-based temperature measurements can be extended beyond the surface to provide depth-selective temperature measurements by incorporating the thermographic phosphor layer at the depth where the temperature measurement is desired. In this paper, the use of thermographic phosphor (Y2O3:Eu) luminescence decay time measurements is demonstrated for the first time for through-the-thickness temperature readings up to 1000 C with the phosphor placed beneath a 100-micron-thick TBC (plasma-sprayed 8wt% yttria-stabilized zirconia). With an appropriately chosen excitation wavelength and detection configuration, it is shown that sufficient phosphor emission is generated to provide effective temperature measurements, despite the attenuation of both the excitation and emission intensities by the overlying TBC. This depth-selective temperature measurement capability should prove particularly useful for TBC diagnostics, where a large thermal gradient is typically present across the TBC thickness.

Eldridge, J. I.↗

Depth-Selective Diagnostics of Thermal Barrier Coatings Incorporating Thermographic Phosphors

Thermographic phosphors have been previously demonstrated to provide effective non-contact, emissivity-independent surface temperature measurements. Because of the translucent nature of thermal barrier coatings (TBCs), thermographic-phosphor-based temperature measurements can be extended beyond the surface to provide depth-selective temperature measurements by incorporating the thermographic phosphor layer at the depth where the temperature measurement is desired. In this paper, thermographic phosphor (Y2O3:Eu) fluorescence decay time measurements are demonstrated for the first time to provide through-the-coating-thickness temperature readings up to 1000 C with the phosphor layer residing beneath a 100-Fm-thick TBC (plasma-sprayed 8wt% yttria-stabilized zirconia). With an appropriately chosen excitation wavelength and detection configuration, it is shown that sufficient phosphor emission is generated to provide effective temperature measurements, despite the attenuation of both the excitation and emission intensities by the overlying TBC. This depth-selective temperature measurement capability should prove particularly useful for TBC diagnostics, where a large thermal gradient is typically present across the TBC thickness.

Eldridge, Jeffrey I.↗

Evaluation of a novel mid-infrared pyrometer for dynamic material experiments

Temperature is a complicated thermodynamic parameter to measure in dynamic compression experiments. Optical pyrometry is a general-purpose “work-horse” technique for measuring temperature from a radiant surface on these experimental platforms. The optical pyrometry channels are commonly held to the visible or Near-Infrared spectrum, which provides high fidelity temperature measurement for shock temperature above ∼1200–1500 K. However, low temperature (T < 1200 K) dynamic material experiments, including low pressure or quasi-isentropic studies, as well as experiments with complex thermodynamic paths, require Mid-Infrared (Mid-IR) for high fidelity measurements. This article outlines the design, testing, and characterization of a novel Mid-IR pyrometer system that can be configured between 2.5 and 5.0 µm, suitable for lower temperature measurements and for increasing the fidelity and precision of higher temperature measurements. Experimental validation was done on two separate gas gun platforms, with two separate impact velocities, achieving temperatures between 450 and 1100 K.

Dutra, E. C. (ORCID:0000000167649195)↗

One-Dimensional Spontaneous Raman Measurements of Temperature Made in a Gas Turbine Combustor

The NASA Glenn Research Center is working with the aeronautics industry to develop highly fuel-efficient and environmentally friendly gas turbine combustor technology. This effort includes testing new hardware designs at conditions that simulate the high-temperature, high-pressure environment expected in the next-generation of high-performance engines. Glenn has the only facilities in which such tests can be performed. One aspect of these tests is the use of nonintrusive optical and laser diagnostics to measure combustion species concentration, fuel/air ratio, fuel drop size, and velocity, and to visualize the fuel injector spray pattern and some combustion species distributions. These data not only help designers to determine the efficacy of specific designs, but provide a database for computer modelers and enhance our understanding of the many processes that take place within a combustor. Until recently, we lacked one critical capability, the ability to measure temperature. This article summarizes our latest developments in that area. Recently, we demonstrated the first-ever use of spontaneous Raman scattering to measure combustion temperatures within the Advanced Subsonics Combustion Rig (ASCR) sector rig. We also established the highest rig pressure ever achieved for a continuous-flow combustor facility, 54.4 bar. The ASCR facility can provide operating pressures from 1 to 60 bar (60 atm). This photograph shows the Raman system setup next to the ASCR rig. The test was performed using a NASA-concept fuel injector and Jet-A fuel over a range of air inlet temperatures, pressures, and fuel/air ratios.

Hicks, Yolanda R.↗

Power Plant Testing of Ultrasonic Measurements of Temperature Distributions and Heat Fluxes to Heat Exchange Surfaces

Extreme environmental conditions are common in energy conversion applications, in which the most hardened insertion sensors often do not perform reliably for long. On the other hand, ultrasonic measurements can be acquired noninvasively, with sensitive components kept away from the damaging environment. We have previously developed the ultrasonic method for measuring the spatial distribution of temperatures in solid materials applicable when large thermal gradients are present. In the developed approach, we use the echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features, to produce a train of echoes in response to an external pulse of ultrasonic excitation. This paper outlines the testing results of this approach applied to the temperature distribution measurements to a waterwall of a 500 MW power-plant utility boiler. The validation results obtained over the prolonged power plant test show that the estimated temperature profile is correctly captured, and the measurement accuracy can be comparable with traditional insertion sensors, such as thermocouples. Overall, the testing has confirmed that the developed approach has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term temperature measurements in extreme environments. Heat fluxes and thermal stresses in the structure can then be characterized noninvasively using the measured temperature distribution as the basis.

Walton, Kenneth↗

Application of a radiometric method to the measurement of temperature in self-absorbing gases

A radiometric method for the measurement of gas temperature in self-absorbing gases has been applied in the study of shock-tube-generated flows. This method involves making two absolute-intensity measurements at the same wavelength in a specified gas sample, but using two different path lengths. Experimental results are presented for reflected shock waves in air and in xenon at conditions corresponding to shock velocities from 4 to 10 km/sec and an initial driven tube pressure of 1 torr. These results indicate that, with the technique, temperature measurements with an accuracy of 5% can be carried out. The measurements in air suggest certain facility-related problems, and results obtained in the application of this measurement technique to the investigation of these problems and to the study of radiative cooling phenomena in both air and xenon are presented.

Nerem, R. M.↗

Containerless high temperature property measurements by atomic fluorescence

The use of laser induced fluorescence (LIF) techniques for containerless study of high temperature processes and material properties is studied. Gas jet and electromagnetic levitation and electromagnetic and laser heating techniques are used with LIF in Earth-based containerless high temperature experiments. The work to date includes development of an apparatus and its use in studies of chemical reactions on Al2O3, molybdenum, and tungsten specimens, novel methods for noncontact specimen temperature measurement, and levitation jet properties. Brief summaries of these studies are given. The apparatus is described and detailed results for the current reporting period are presented.

Source record↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the non-liquid-level-sensing temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode . a known function of the current and temperature . is measured as an indication of its temperature. For the purpose of this measurement, "small electric current" signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired locations along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode a known function of the current and temperature is measured as an indication of its temperature. For the purpose of this measurement, small electric current signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when the diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired location along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone on TEXUS36

Several pg experiments on sounding rockets and the Space Shuttle have shown that time-dependent thermocapillary (Marangoni) convection is the major cause for the formation of dopant striations in floating-zone grown semiconductor crystals, at least in small-scale systems not employing RF heating. To quantify this correlation, a silicon floating-zone experiment was performed during the TEXUS36 flight (February 7, 1 998) in the monoellipsoid mirror furnace TEM02-ELLI. During the experiment, temperature fluctuations in the silicon melt zone and the microscopic growth rate were simultaneously measured. Temperature fluctuations of 0.5 C - 0.7 C with main frequencies between 0.1 Hz and 0.3Hz were detectable. The microscopic growth rate fluctuated considerably around the average growth rate of 1 mm/min: rates from 4mm/min to negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. They were characterized by Spreading Resistance measurements and Differential Interference Contrast microscopy. The frequencies associated with the dopant inhomogeneities correspond quite well with those of the temperature fluctuations and microscopic growth rates. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, to evaluate characteristic temperature amplitudes and frequencies, and to give insight into the instability mechanisms of Marangoni convection in this configuration. The simulations were in good agreement with the experimental values, showing temperature fluctuations with frequencies? 0.25 Hz and amplitudes up to 1.8 C at a position equivalent to that of the sensor tip in the experiment.

Croell, Arne↗

Measurement of Temperature Fluctuations and Microscopic Growth Rates in a Silicon Floating Zone Under Microgravity

USA Several microgravity experiments on sounding rockets and the Space Shuttle have shown that time-dependent thermocapillary (Marangoni) convection is the major cause for the formation of dopant striations in floating-zone grown semiconductor crystals, at least in small-scale systems not employing RF heating. To quantify this correlation, a silicon floating-zone experiment was performed during the TEXUS36 flight (February 7, 1998) in the monoellipsoid mirror furnace TEM02-ELLI. During the experiment, temperature fluctuations in the silicon melt zone and the microscopic growth rate were simultaneously measured. Temperature fluctuations of 0.5 C - 0.7 C with main frequencies between 0.1 Hz and 0.3 Hz were detectable. The microscopic growth rate fluctuated considerably around the average growth rate of 1 mm/min: rates from 4 mm/min to negative values (backmelting) were observed. Dopant striations are clearly visible in the Sb-doped crystal. They were characterized by Spreading Resistance measurements and Differential Interference Contrast microscopy. The frequencies associated with the dopant inhomogeneities correspond quite well with those of the temperature fluctuations and microscopic growth rates. 3D numerical simulations were performed to predict the optimum position of the temperature sensor, to evaluate characteristic temperature amplitudes and frequencies, and to give insight into the instability mechanisms of Marangoni convection in this configuration. The simulations were in good agreement with the experimental values, showing temperature fluctuations with frequencies ? 0.25 Hz and amplitudes up to 1.8 C at a position equivalent to that of the sensor tip in the experiment.

Croell, Arne↗

In Situ Measurement of Temperature Distributions in a Li-ion Cell during Internal Short Circuit and Thermal Runaway

Here we report in situ measurement of temperature distributions in a 2.5-Ah pouch format Li-ion cell during internal short circuit (ISC) and thermal runaway. The ISC and thermal runaway were triggered by nail penetration. The local temperatures were measured by embedded K type micro thermocouples in the middle layer of the experimental Li-ion cell. Highly non-uniform temperature distributions were observed during ISC and thermal runaway as compared with those during constant current discharging and external short circuit. The in situ measurement also captured details of how thermal runaway started from the ISC location and spread to the entire cell in a few seconds. Moreover, the comparison between ISC without thermal runaway and ISC with thermal runaway suggests that internal short circuit resistance plays a critical role in the risk of thermal runaway.

Huang, Shan↗

Calibration of Distributed Temperature Sensors Using Commercially Available SMF-28 Optical Fiber From 22 °C to 1000 °C

Optical frequency domain reflectometry (OFDR) is a family of optical techniques which can be used to produce distributed temperature measurements from the spectral shift of an interference pattern based on the Rayleigh backscatter signature of an optical fiber. Adaptive signal processing techniques have recently been used with OFDR to record meaningful spectral shift data from commercially available SMF-28 optical fibers heated beyond 950 °C. Furthermore, a correlation between the measured spectral shift and temperature has not yet been developed at these high temperatures. To extend the measurable temperature range of OFDR in SMF-28, this work describes the development of such a correlation from room temperature (22 °C) to 1000 °C. The relationship between spectral shift and temperature change over this range was found to be best characterized by the fourth-order polynomial ΔT=(-4.241 * 10 -11 )S 4 + (-2.017 * 10 -7 )S 3 + (-3.677 * 10 -4 )S 2 + (-0.8057)S, where ΔT represents the temperature difference compared to the reference temperature, and S represents the spectral shift measured by the fibers. The calibration developed in this work assumes that the fiber has been fully annealed by heating the fiber to 1000 °C for a few hours. This paper is the first to demonstrate the calibration and use of SMF-28 distributed optical fiber sensors up to 1000 °C, enabled using adaptive OFDR-based signal processing.

47 OTHER INSTRUMENTATION↗