Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System Security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Multichannel Deconvolution of Vibrational Shock Signals: An Inverse Filtering Approach

When transporting critical systems of national security interest, out-of-the ordinary, impulsive events that can potentially be undetected and affect overall system performance are of great concern. Impulsive events that can occur are essentially pulse-like, transient signals of short duration that evolve from various phenomena. Here the event can be created by either the dropping of a test object, the system, subjecting it to a compact high-energy blow or being struck unintentionally during transit resulting in potential damage. The intensity and location of the strike can cause an inoperability condition that is unacceptable in a national security environment. Therefore, it is essential to detect, classify and localize damage of any test object subjected to an impulsive-event. This effort was targeted to evaluate the vibrational response of test objects that are subjected to “transport” shocks and roadway vibrations during shipping and handling. Any potential damage that could be inflicted during transportation must not only be detected, but also be evaluated to determine the operational readiness of a test object before and after transport. This event is a critical task that must be addressed as part of the Lawrence Livermore National Laboratory (LLNL) national security mission. The estimation of excitation signals from noisy data is termed the deconvolution problem in the signal processing literature. The deconvolution problem is based on recovering the input excitation signal from a system characterized by its impulse response sequence. Using this model of the system, an “inverse” representation or filter is developed to remove the system from the measured data and recover the input. Deconvolution techniques have existed for a long-time; however, transient deconvolution presents a few uncommon problems, since the signal has a finite-length time duration resulting in a limited amount of data containing information about the excitation process. The transient is wideband in the frequency domain relative to any measurement sensor implying that the smaller bandwidth sensor system “filters” the excitation eliminating some of its essential information for recovery. This fact, coupled with the filtering effect of the test object itself makes this excitation recovery (deconvolution) problem a challenge for signal processing.

42 ENGINEERING↗

Chemical Security Principles of Material Control and Accountability (MC&A) using a Chemical Inventory Management System.

Chemical Risk Management is a system or process to control safety and security risks associated with hazardous or toxic chemicals. Chemical Risk Management includes the management of both chemical safety and chemical security. There are five pillars that make up chemical security management10 (Figure 1). Each of the five pillars are key components to the implementation of a chemical security risk management system. In this paper, we will review the "Material Control and Accountability" pillar and how an academic institution can implement this principle using a chemical inventory management system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Increasing the Security and Resilience of the Electric Power System

Through its Laboratory Directed Research and Development (LDRD) program, NREL is investigating how the resilience of the electric power system can be measured, evaluated, and visualized - ultimately to provide utilities, government agencies, and communities with tools that can help them prepare for a variety of unpredictable scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrating AEAD Ciphers into Software-Defined-Storage Systems

The use of software-defined storage (SDS) systems to store sensitive data is becoming increasingly prevalent. However, these systems primarily implement security measures to ensure the confidentiality and availability of stored data, with limited consideration for the protection of its integrity. This paper outlines why this is a harmful development, as well as how integrity-protecting measures can be included into SDS systems. To demonstrate the practical challenges and opportunities of such measures, we integrated "authenticated encryption with associated data" (AEAD) ciphers into the widely used SDS system Ceph, specifically, into its block storage interface, to secure the integrity of stored data and metadata. Ultimately, we identify the characteristics that an SDS system should possess to adopt our methodology.

Mohren, David [University of New Brunswick, Canada↗

Verification of Triple Modular Redundancy (TMR) Insertion for Reliable and Trusted Systems

We propose a method for TMR insertion verification that satisfies the process for reliable and trusted systems. If a system is expected to be protected using TMR, improper insertion can jeopardize the reliability and security of the system. Due to the complexity of the verification process, there are currently no available techniques that can provide complete and reliable confirmation of TMR insertion. This manuscript addresses the challenge of confirming that TMR has been inserted without corruption of functionality and with correct application of the expected TMR topology. The proposed verification method combines the usage of existing formal analysis tools with a novel search-detect-and-verify tool. Field programmable gate array (FPGA),Triple Modular Redundancy (TMR),Verification, Trust, Reliability,

Trust↗

Towards generic memory forensic framework for programmable logic controllers

A Programmable Logic Controller (PLC) is a microprocessor-based controller that is used to automate physical processes in critical infrastructure and various other industries and manufacturing sectors. Initially, PLCs were completely isolated from the Internet, and cyber security was not incorporated at the time of development. The introduction of industry 4.0 and the evolution of ICS systems to communicate over public IP addresses from the Internet enhanced productivity and efficiency, but Internet connectivity exposed the systems and their vulnerabilities, which led to an increase in cyber attacks. When a system is sabotaged/compromised, security analysts need to get to the root cause of the attack as quickly as possible to recover the system. To do so, memory forensic analysis is critical to provide a unique insight into the run-time memory activities and extract a reliable source of evidence. In this paper, we analyze the memory structure of the Schneider Electric Modicon M221 PLC. To build a memory profile, we reverse engineer the communication protocol and conduct differential analysis to gain knowledge about the structure of the memory and the low-level representation of control logic instructions. We then identify dynamic and static memory regions by modifying different project fields and conducting differential analysis, which allows us to identify boundaries of critical memory structures and extract important forensic artifacts that can be found in the memory. The Python implementation of the memory profile can help reduce the time and effort required for manual analysis in case of cyber incident or system failure.

97 MATHEMATICS AND COMPUTING↗

Developing a Standard Method for Link-Layer Security of CCSDS Space Communications

Communications security for space systems has been a specialized field generally far removed from considerations of mission interoperability and cross-support in fact, these considerations often have been viewed as intrinsically opposed to security objectives. The space communications protocols defined by the Consultative Committee for Space Data Systems (CCSDS) have a twenty-five year history of successful use in over 400 missions. While the CCSDS Telemetry, Telecommand, and Advancing Orbiting Systems protocols for use at OSI Layer 2 are operationally mature, there has been no direct support within these protocols for communications security techniques. Link-layer communications security has been successfully implemented in the past using mission-unique methods, but never before with an objective of facilitating cross-support and interoperability. This paper discusses the design of a standard method for cryptographic authentication, encryption, and replay protection at the data link layer that can be integrated into existing CCSDS protocols without disruption to legacy communications services. Integrating cryptographic operations into existing data structures and processing sequences requires a careful assessment of the potential impediments within spacecraft, ground stations, and operations centers. The objective of this work is to provide a sound method for cryptographic encapsulation of frame data that also facilitates Layer 2 virtual channel switching, such that a mission may procure data transport services as needed without involving third parties in the cryptographic processing, or split independent data streams for separate cryptographic processing.

Biggerstaff, Craig↗

Automating security monitoring and analysis for Space Station Freedom's electric power system

Operating a large, space power system requires classifying the system's status and analyzing its security. Conventional algorithms are used by terrestrial electric utilities to provide such information to their dispatchers, but their application aboard Space Station Freedom will consume too much processing time. A new approach for monitoring and analysis using adaptive pattern techniques is presented. This approach yields an on-line security monitoring and analysis algorithm that is accurate and fast; and thus, it can free the Space Station Freedom's power control computers for other tasks.

Dolce, James L.↗

Automating security monitoring and analysis for Space Station Freedom's electric power system

Operating a large, space power system requires classifying the system's status and analyzing its security. Conventional algorithms are used by terrestrial electric utilities to provide such information to their dispatchers, but their application aboard Space Station Freedom will consume too much processing time. A novel approach for monitoring and analysis using adaptive pattern techniques is presented. This approach yields an on-line security monitoring and analysis algorithm that is accurate and fast; and thus, it can free the Space Station Freedom's power control computers for other tasks.

Dolce, James L.↗

A Robust Method to Secure Multi-Inverter Grid Tied PV and Battery Energy Storage Systems Against Cyber Intrusions

This paper details a robust method to secure a multi-inverter grid tied system that interfaces photovoltaic (PV) and battery energy storage against potential cyber-attacks. The method can be applied to any third-party inverter systems without a need to modify their internal controls. A small random private excitation signal termed "watermark" is injected into the DC input voltage terminals (via a series transformer) connected to the PV/battery inverter system. An external robust cyber intrusion detector (CID) hardware consisting of a digital signal processor (DSP) generates the "watermark" and also receives the sensor signals that control the setpoints of the PV/battery grid tied system. The CID algorithm is shown to detect all possible cyber intrusions (such as false data injection(FDI)) on external sensor signals such as P and Q measured by a smart meter that control the overall system operation. The proposed CID computes online system ID and two variance tests in real time on each sensor signal and is able pinpoint intrusion location in a multi-inverter system. Results on a hardware in the loop (HIL) of a two-inverter grid connected system demonstrate effectiveness of the proposed CID system for FDI and unobservable FDI. Test results on a laboratory prototype will be discussed in the conference presentation.

Ibrahim, Hasan↗

A Review of Machine Learning Applications in Power System Resilience

The integration of power electronics enabled devices and the high penetration of renewable energy drastically increase the complexity of power system operation and control. Power systems are still vulnerable to large-scale blackouts caused by extreme natural events or man-made attacks. With the recent development in artificial intelligence technique, machine learning has shown a processing ability in computational, perceptual and cognitive intelligence. It is an urgent challenge to integrate the advanced machine learning technology and large amount of real-time data from wide area measurement systems and intelligent electronic devices, in order to effectively enhance power system resilience and ensure the reliable and secure operation of power systems. Therefore, this paper aims to systematically review the existing application of machine learning methods on power system resilience enhancement, to expand the interest of researchers and scholars in this topic, and to jointly promote the application of artificial intelligence in the field of power systems.

Deep Learning↗

eProject Builder (ePB) v3.1

eProject Builder (ePB) is a secure, web-based system that enables agencies and ESCOs to securely: (1) preserve, track, and access energy project information for the life of the contract (2) quickly generate data and reports for their portfolio of projects (3) develop project scenarios using standardized amortization calculations (4) benchmark new projects against historical project data

Larsen, Peter↗

Secure Policy-Based Configuration Framework (PBCONF)

In 2013, EPRI and a project team comprised of the University of Illinois at Urbana-Champaign, Ameren, and Schweitzer Engineering Laboratories began a multi-year effort under an award from the U.S. Department of Energy Office of Electricity Delivery and Energy Reliability Cyber Security or Energy Delivery Systems (CEDS) to develop a framework for secure remote configuration of modern and legacy devices. A goal of this Secure Policy-Based Configuration Framework (PBCONF) is to develop an extensible, open source, policy-based configuration framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Cybersecurity with System Operations and Restoration

This presentation covers the interaction of the discipline of system operations with the discipline of cybersecurity. First, a common mental model for risk - both cybersecurity and all-hazards - is presented, followed by a discussion of high-level management strategies for different kinds of cyber harm facing system operators, based on the consequences and frequencies of the harm. The next section covers the importance of cybersecurity for a system operator organization and explains some general concepts to understand the relationships. Finally the role of system operators in the security of the grid as a larger system of systems is discussed over the framework of a resilience event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Securing against errors in an error correcting code (ECC) implemented in an automotive system

In general, data is susceptible to errors caused by faults in hardware (i.e. permanent faults), such as faults in the functioning of memory and/or communication channels. To detect errors in data caused by hardware faults, the error correcting code (ECC) was introduced, which essentially provides a sort of redundancy to the data that can be used to validate that the data is free from errors caused by hardware faults. In some cases, the ECC can also be used to correct errors in the data caused by hardware faults. However, the ECC itself is also susceptible to errors, including specifically errors caused by faults in the ECC logic. A method, computer readable medium, and system are thus provided for securing against errors in an ECC.

Saxena, Nirmal Raj↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

U.S. Domestic Molten Salt Reactor: Security-by-Design

U.S. nuclear power facilities face increasing challenges in meeting dynamic security requirements caused by evolving and expanding threats while keeping costs reasonable to make nuclear energy competitive. The past approach has often included implementing security features after a facility has been designed and without attention to optimization, which can lead to cost overruns. Incorporating security in the design process can provide robust, economical, and effective physical protection systems (PPS). The purpose of this work is both to develop a framework for the integration of security into the design phase of a molten salt reactor (MSR) and show how to effectively design a PPS with a reduced staffing headcount. Specifically, this work focuses on integrating PPS design features into a developed facility layout by making minor modifications to building structures. A suite of tools, including Scribe3D©, PathTrace©, and Blender©, were used to model a hypothetical, generic domestic MSR facility. Physical protection elements such as sensors, cameras, barriers, and responders were added into the model based on defending the hypothetical MSR facility against a hypothetical design basis threat (DBT). Multiple outsider sabotage scenarios were examined, with adversary team sizes ranging from 4–8 to determine security system effectiveness. The results of this work will influence PPS designs and facility designs for U.S. domestic MSRs. This work will also demonstrate how a series of experimental and modeling capabilities across the Department of Energy (DOE) complex can impact the design and completion of security-by-design (SeBD) for small modular reactors (SMRs). The conclusions and recommendations in this document may be applicable to all SMR designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Small Modular Reactor and Microreactor Security-by-Design Lessons Learned: Integrated PPS Designs

U.S. nuclear power facilities face increasing challenges in meeting dynamic security requirements caused by evolving and expanding threats while keeping costs reasonable to make nuclear energy competitive. The past approach has often included implementing security features after a facility has been designed and without attention to optimization, which can lead to cost overruns. Incorporating security into the design process can provide robust, cost-effective, and sufficient physical protection systems. The purpose of this report is to capture lessons learned by the Advanced Reactor Safeguards and Security (ARSS) program that may be beneficial for other advanced and small modular reactor (SMR) vendors to use when developing security systems and postures. This report will capture relevant information that can be used in the security-by-design (SeBD) process for SMR and microreactor vendors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗