Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Specifiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Data Validation Package - April and July 2015 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site

This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites. Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Domestic wells 0476 and 0477 were sampled in July because the homes were unoccupied in April, and the wells were not in use. Duplicate samples were collected from locations 0113, 0248, and 0477. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. No issues were identified during the data validation process that requires additional action or follow-up.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package: April 2016 Groundwater Sampling at the Falls City, Texas, Disposal Site

Nine groundwater samples were collected at the Falls City, Texas, Disposal Site as specified in the March 2008 Long-Term Surveillance Plan for the US Department of Energy Falls City Uranium Mill Tailings Disposal Site, Falls City, Texas (DOE-LM/1602-2008). Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). The wells sampled included the cell performance monitoring wells (0709, 0858, 0880, 0906, and 0921) and the groundwater monitoring wells (0862, 0886, 0891, 0924, and 0963). A duplicate sample was collected from location 0891. Water levels were measured at each sampled well. Historically, cell performance monitoring wells 0908 and 0916 have not produced water and were confirmed as dry during this sampling event. These wells are completed above the saturated interval in the formation. Notable observations for time-concentration graphs in this report include: (1) uranium concentrations in well 0891 continue to increase; (2) the uranium concentration in well 0880 is higher than the 2015 value and lower than the 2014 value, and it remains within the range of historical values; and (3) uranium concentrations in the other sampled wells are below 2 mg/L and consistent with previous results.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package - June 2016 Groundwater and Surface Water Sampling at the Green River, Utah, Disposal Site

This event included annual sampling of groundwater and surface water locations at the Green River, Utah, Disposal Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for US. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lrnldownloads/sampling-and- analysis-plan-us-department-energy-office-legacy-management-sites). Samples were collected from 15 monitoring wells and two surface locations at the disposal site as specified in the draft 2011 Ground Water Compliance Action Plan for the Green River, Utah, Disposal Site. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0179. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. See Attachment 2, Trip Reports for additional details. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that requires additional action or follow-up.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package - July 2016 Groundwater Sampling at the Gunnison, Colorado, Disposal Site

Groundwater sampling at the Gunnison, Colorado, Disposal Site is conducted every 5 years to monitor disposal cell performance. During this event, samples were collected from eight monitoring wells as specified in the 1997 Long-Term Surveillance Plan for the Gunnison, Colorado, Disposal Site. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for US Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and­ analysis-plan-us-department-energy-office-legacy-management-sites). Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. A duplicate sample was collected from location 0723. Water levels were measured at all monitoring wells that were sampled and seven additional wells. The analytical data and associated qualifiers can be viewed in environmental database reports and are also available for viewing with dynamic mapping via the GEMS (Geospatial Environmental Mapping System) website at http://gems.lm.doe.gov/#. No issues were identified during the data validation process that require additional action or follow-up.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package, December 2015, Groundwater and Surface Water Sampling at the Monument Valley, Arizona, Processing Site March 2016

Fifty-two groundwater samples and one surface water sample were collected at the Monument Valley, Arizona, Processing Site to monitor groundwater contaminants for evaluating the effectiveness of the proposed compliance strategy as specified in the 1999 Final Site Observational Work Plan for the UMTRA Project Site at Monument Valley, Arizona. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and-analysis-plan-us-department- energy-office-legacy-management-sites). Samples were collected for metals, anions, nitrate + nitrite as N, and ammonia as N analyses at all locations.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package October 2015 Groundwater and Surface Water Sampling at the Monticello, Utah, Processing Site January 2016

Sampling Period: October 12–14, 2015. This semiannual event includes sampling groundwater and surface water at the Monticello Mill Tailings Site. Sampling and analyses were conducted as specified in the 2004 Monticello Mill Tailings Site Operable Unit III Post-Record of Decision Monitoring Plan, Draft Final and Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). Samples were collected from 52 of 61 planned locations (15 of 17 former mill site wells, 17 of 18 downgradient wells, 9 of 9 downgradient permeable reactive barrier wells, 2 of 7 seeps and wetlands, and 9 of 10 surface water locations). Locations MW00-07, Seep 1, Seep 2, Seep 3, Seep 5, Seep 6, SW00-01, T01-13, and T01-19 were not sampled because of insufficient water availability. All samples were filtered as specified in the monitoring plan. Duplicate samples were collected from surface water location W3-04 and from monitoring wells 82-08, 92-09, and 92-10. Water levels were measured at all but one sampled well and an additional set of wells. The contaminants of concern (COCs) for the Monticello Mill Tailings Site are arsenic, manganese, molybdenum, nitrate + nitrite as nitrogen (nitrate + nitrite as N), selenium, uranium, and vanadium. Time-concentration graphs of the COCs for all groundwater and surface water locations are included in this report. Locations with COCs that exceeded remediation goals are listed.

2015 Monticello↗

NESHAP Area-Specific Dose-Release Factors for Potential Onsite Member-of-the-Public Locations at SRS using CAP88-PC Version 4.0

The Environmental Protection Agency (EPA) requires the use of the computer model CAP88-PC to estimate the total effective doses (TED) for demonstrating compliance with 40 CFR 61, Subpart H (EPA 2006), the National Emission Standards for Hazardous Air Pollutants (NESHAP) regulations. As such, CAP88 Version 4.0 was used to calculate the receptor dose due to routine atmospheric releases at the Savannah River Site (SRS). For estimation, NESHAP dose-release factors (DRFs) have been supplied to Environmental Compliance and Area Closure Projects (EC&ACP) for many years. DRFs represent the dose to a maximum receptor exposed to 1 Ci of a specified radionuclide being released into the atmosphere. They are periodically updated to include changes in the CAP88 version, input parameter values, site meteorology, and location of the maximally exposed individual (MEI). In this report, the DRFs were calculated for potential radionuclide atmospheric releases from 13 SRS release points. The three potential onsite MEI locations to be evaluated are B-Area, Three Rivers Landfill (TRL), and Savannah River Ecology Lab Conference Center (SRELCC) with TRL’s onsite workers considered as members-of-the-public, and the potential future constructions of dormitories at SRELCC and Barracks at B-Area. Each MEI location was evaluated at a specified compass sector with different area to receptor distances and was conducted for both ground-level and elevated release points. The analysis makes use of area-specific meteorological data (Viner 2014). The resulting DRFs are compared to the 2014 NESHAP offsite MEI DRFs for three operational areas; A-Area, H-Area, and COS for a release rate of 1 Ci of tritium oxide at 0 ft. elevation. CAP88 was executed again using the 2016 NESHAP MEI release rates for 0 and 61 m stack heights to determine the radionuclide dose at TRL from the center-of-site (COS).

54 ENVIRONMENTAL SCIENCES↗

Simulant Basis for the Standard High Solids Vessel Design

The Waste Treatment and Immobilization Plant (WTP) is working to develop a Standard High Solids Vessel Design (SHSVD) process vessel. To support testing of this new design, WTP engineering staff requested that a Newtonian simulant and a non-Newtonian simulant be developed that would represent the Most Adverse Design Conditions (in development) with respect to mixing performance as specified by WTP. The majority of the simulant requirements are specified in 24590-PTF-RPT-PE-16-001, Rev. 0. The first step in this process is to develop the basis for these simulants. This document describes the basis for the properties of these two simulant types. The simulant recipes that meet this basis will be provided in a subsequent document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Reload and Startup Plan for and #8233;Conversion of the NIST Research Reactor

The National Institute of Standards and Technology operates a 20 MW research reactor for neutron-based research. The heavy-water moderated and cooled reactor is fueled with high-enriched uranium (HEU) but a program to convert the reactor to low-enriched uranium (LEU) fuel is underway. Among other requirements, a reload and startup test plan must be submitted to the U.S. Nuclear Regulatory Commission (NRC) for their approval. The NRC provides guidance for what should be in the plan to ensure that the licensee has sufficient information to operate the reactor safely. Hence, a plan has been generated consisting of two parts.The reload portion of the plan specifies the fuel management whereby initially only two LEU fuel elements are in the core for eight fuel cycles. This is repeated until a point when the optimum approach is to place four fresh LEU elements into the reactor each cycle. This final transition is repeated and after eight cycles the reactor is completely fueled with LEU. By only adding two LEU fuel elements initially, the plan allows for the consumption of HEU fuel elements that are expected to be in storage at the time of conversion and provides additional qualification of production LEU fuel under actual operating conditions. Because the reload is to take place over many fuel cycles, startup tests will be done at different stages of the conversion. The tests, to be compared with calculations to show that the reactor will operate as planned, are the measurement of critical shim arm position and shim arm and regulating rod reactivity worths. An acceptance criterion for each test is specified based on technical specifications that relate to safe operation. Additional tests are being considered that have less safety significance but may be of interest to bolster the validation of analysis tools.

42 ENGINEERING↗

MESH2D Grid generator design and use

Mesh2d is a Fortran90 program originally designed to generate two-dimensional structured grids of the form [x(i),y(i,j)] where [x,y] are grid coordinates identified by indices (i,j). x-coordinates depending only on index i implies strictly vertical x-grid lines, whereas the y-grid lines can undulate. Mesh2d also assigns an integer material type to each grid cell, mtyp(i,j), in a user-specified manner. The complete grid is specified through three separate input files defining the x(i), y(i,j), and mtyp(i,j) variations. Since the original development effort, Mesh2d has been extended to more general two-dimensional structured grids of the form [x(i,j),(i,j)].

24 POWER TRANSMISSION AND DISTRIBUTION↗

MC 2 -3: Multigroup Cross Section Generation Code for Fast Reactor Analysis

The MC 2 -3 code is a Multigroup Cross section generation Code for fast reactor analysis, developed by improving the resonance self-shielding and spectrum calculation methods of MC 2 -2 and integrating the one-dimensional cell calculation capabilities of SDX. The code solves the consistent P1 multigroup transport equation using basic neutron data from ENDF/B data files to determine the fundamental mode spectra for use in generating multigroup neutron cross sections. A homogeneous medium or a heterogeneous slab or cylindrical unit cell problem is solved in ultrafine (~2000) or hyperfine (~400,000) group levels. In the resolved resonance range, pointwise cross sections are reconstructed with Doppler broadening at specified isotopic temperatures. The pointwise cross sections are directly used in the hyperfine group calculation whereas for the ultrafine group calculation, self-shielded cross sections are prepared by numerical integration of the pointwise cross sections based upon the narrow resonance approximation. For both the hyperfine and ultrafine group calculations, unresolved resonances are self-shielded using the analytic resonance integral method. The ultrafine group calculation can also be performed for two-dimensional whole-core problems to generate region-dependent broad-group cross sections. Multigroup cross sections are written in the ISOTXS format for a user-specified group structure. The code is executable on UNIX, Linux, and PC Windows systems, and its library includes all isotopes of the ENDF/BVII. 0 data.

20 FOSSIL-FUELED POWER PLANTS↗

Technical Project Plan for Meteorological Monitoring

This Technical Project Plan (TPP) specifies how the Los Alamos National Laboratory (LANL) Meteorology Monitoring Project implements the quality and technical activities defined by Department of Energy (DOE) orders and State and Federal regulations. The quality and technical requirements for meteorological monitoring are specified by DOE Order 414.1d Quality Assurance, Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans (EPA 2002), and ANSI Standard 3.11 Determining Meteorological Information at Nuclear Facilities. The TPP will be reviewed annually and revised as necessary.

54 ENVIRONMENTAL SCIENCES↗

Advanced Energy System Design (AESD): Technical Manual for the Records API

The Records API (application program interface) for Advanced Energy System Design (AESD) enables software that serves multidimensional record-oriented data to interoperate with software than uses such data. In the context of the Records API, multidimensional data records are simply tuples of real numbers, integers, and character strings, where each data value is tagged by a variable name, according to a pre-defined schema, and each record is assigned a unique integer identifier. Conceptually, these records are isomorphic to rows in a relational database, JSON objects, or key-value maps. Records servers might supply static datasets, sensor measurements that periodically update as new telemetry become available, or the results of simulations as the simulations generate new output. Records client software might display or analyze the data, but in the case of simulations the client request the creation of new ensembles for specified input parameters. It is also possible to chain records clients and servers together so that a client consuming data from a server might transform that data and serve it to further clients. This minimalist API avoids imposing burdensome metadata, structural, or implementation requirements on developers by relying on open-source technologies that is readily available for common programming languages. In particular, the API has been designed to place the smallest possible burden on services that provide data. This document defines the message format for the Records API, a transport mechanism for communicating the data, and semantics for interpreting it. The message format is specified as Google Protocol Buffers and the transport mechanism uses WebSockets. We discuss three major use cases for serving and consuming records data: (i) static data, (ii) dynamically augmented data, (iii) on-demand simulations, (iv) with filters, and (v) with bookmarks. Separate implementations of the API exist in C++, Haskell, JavaScript, Python, and R.

97 MATHEMATICS AND COMPUTING↗

Assessment of the Idaho National Laboratory Remote Handled Low Level Waste Disposal Facility Hydraulic Performance

This document provides a summary of the expected hydraulic performance of the vault drainage system installed at Idaho National Laboratory’s Remote Handled Low-Level Waste disposal facility. Hydraulic performance was assessed through analysis of the mechanical properties of the drainage system and backfill materials, including material gradation and proctor data; laboratory data, including bulk density, porosity, unsaturated hydraulic conductivity, moisture-retention data, and van Genuchten parameters; and field-data collected using in-situ instrumentation with data collected during a vault-scale infiltration characterization test. Hydraulic performance of the vault drainage system was designed to promote a greater than 500-year vault concrete longevity. The predicted hydraulic performance is, in part, a function of the materials used in construction, sequencing of the hydraulic drainage materials, and the as-built condition of the materials following compaction necessary to ensure vault stability. Specifying specific as-built hydraulic properties is exceedingly difficult at the facility specification/design phase. Instead, material mechanical properties were specified and confirmed early during the construction process. As the drainage materials were installed, samples were sent to a laboratory for hydraulic property testing and, after drainage system installation was complete around the performance assessment vaults, a field-scale infiltration test was conducted with data collection to verify the as-built hydraulic performance. This report provides summary data for the measured mechanical properties, laboratory data, and field infiltration characterization test data. Mechanical data have relatively little variability because of the sieve system used when the materials were crushed onsite. Laboratory data were obtained for a relatively small number of material samples, but the data obtained for each sample are extensive. However, laboratory data provide the moisture retention relationships and relative hydraulic conductivity-moisture content relationships for uninstalled materials. Conducting field-scale infiltration tests with collection of moisture retention data and wetting front propagation data allows extension of laboratory data to the as-installed conditions of the vault drainage system. These combined data types are integrated using a numerical simulation of the infiltration characterization test to refine model parameters. The infiltration characterization model will be used to support the hydraulic and concrete performance of the vault system provided in the facility performance assessment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiological Engineering Design Analysis of the NDA Table Shielding Configuration

This document provides an evaluation of the radiological design of the NDA table shielding configuration, which to date has not been analyzed by Radiological Engineering. The purpose of this analysis is to determine compliance with the Department of Energy radiation protection requirements specified in 10 CFR §835 [1] and the LANL specific requirements specified in Chapter 12 of P121 [2] and Chapter 11 of the Engineering Standards Manual (ESM) [3]. An evaluation was required due to the potential for dose rates to exceed 0.5 mrem h -1 during routine operations prior to applying engineered controls [2].

42 ENGINEERING↗

Delayed Gamma-ray Assay for Nuclear Materials Safeguards. Comprehensive Technology Readiness Assessment

Spectroscopic analysis of beta-delayed gamma-rays emitted from fission products following active interrogation was investigated as a non-destructive assay technique for detection and characterization of nuclear materials in shielded and complex configurations. This measurement technique is expected to be applicable to a variety of applications within the nuclear material safeguards, arms control, and emergency response areas, where active neutron interrogation is acceptable. Potential applications of the delayed gamma-ray assay in the nuclear material safeguards area include characterization of U and Pu isotopic content in spent and unirradiated nuclear fuel, enrichment measurements, verification of bulk material in containers, and the characterization of nuclear wastes. In the arms control area, this method can be used as a part of warhead dismantlement measurements to confirm separation of components, and may be applicable in warhead confirmation. In the context of emergency response, it can be used for detailed diagnostics of an unknown item. At present, the delayed gamma-ray assay technology reliably qualifies for the Technical Readiness Level 3 (TRL 3). The R&D work completed under this project has successfully demonstrated the empirical proof-of-concept for this active interrogation technology for a variety of measurement configurations, neutron sources, and nuclear material samples. A robust first-principles analytical signature modeling methodology was developed, experimentally validated, and can be easily extrapolated to a range of realistic measurement scenarios. Several response analysis methodologies have been implemented and deemed reliable for a variety of active interrogation applications in the areas of nuclear material safeguards, arms control, and emergency response. The initial readiness level before the start of this project was assessed at TRL 0, since only fragmentary records of the signature observations and speculative statements of the relevant non-destructive assay applications existed at that time. The delayed gamma-ray technology readiness can be easily advanced to TRL 4 in a short period, if a certain measurement application is specified and set for a demonstration in a laboratory environment. The critical hardware components of the delayed gamma-ray measurement technology (neutron generators, gamma-ray spectrometers) are readily available as COTS and can be configured for a specific deployment configuration. The primary risk of the delayed gamma-ray assay methodology is defined by the applicationspecific uncertainties. Evaluation of the system performance can be effectively completed once the expected measurement purpose, nuclear material characteristics, dimensions, and radiation exposure constraints are specified. A minor risk can be associated with the delayed gamma-ray response analysis techniques. Several approaches were proposed and demonstrated primarily using the modeled signatures. The observed performance may not be easily transferrable to the conditions of a real measurement setup, and some additional R&D may be required. Overall, the delayed gamma-ray assay technology can be recommended for follow-up demonstrations addressing relevant measurement applications in the areas of nuclear material safeguards, arms control, and emergency response.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiological Considerations of Top-off Operation at NSLS-II

High current (500 mA) and low emittance (~1 nm) have been specified for NSLS-II to achieve ultra high brightness in a medium energy (3 GeV) storage ring (1) . This leads to the expectation that the lifetime in NSLS-II will be limited by Touschek scattering, and after commissioning will settle in at ~3 hours. It may well be less in the early days of operation. At the same time, the intensity stability specified by the user community is 1% or better.

36 MATERIALS SCIENCE↗

High Fidelity Forward Model Development for Nuclear Reactor Spent Fuel Technical Nuclear Forensics

The fidelity of the forward model within a spent fuel forensic analysis system was improved by using two unique methodologies. The first consisted of developing a system to create accurate one-group neutron cross-section libraries for any user specified reactor system. In such, a detailed model is developed using the depletion code MONTEBURNS. During MONTEBURNS execution, cross-section libraries are generated at every user specified burnup step in time. These libraries could be developed for many reactor systems, then housed in a database and used for analyzing unknown fuel samples. The forensic analysis system for spent fuel resulted in higher accuracy at predicting the initial uranium isotopic compositions and burnup from spent fuel samples. Using this method, the error in results was reduced from the order of 1-6% down to less than 1% when recovering a fuel sample's burnup and initial uranium isotopic composition. The second method consisted of implementing 2D/3D reactor depletion codes as the forward model within the system's framework. This method would allow the usage of potentially recoverable geometric information from an unknown sample. No predetermined cross-section library is required for the system using this method, therefore potentially reducing model error associated with the neutron flux spectrum. The accuracy of the recovered initial uranium isotopic compositions and burnup from spent fuel samples was also improved using this method, even more so than the first. For MTR reactors, the error using this method was significantly reduced and was driven to below 0.5%. However, additional research may be required to determine the ideal fission yield and recoverable energy per fission for cases where significant amounts of 239 PU are bred and burned throughout the life of the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗