Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Towards a unified model of neutrino-nucleus interactions

The achievement of the goals of the ongoing and future accelerator-based neutrino experiments – notably the determination of CP violating phase in the lepton sector – will require the development of advanced models of neutrino-nucleus interactions. In this review, we summarise the present status of experimental studies of neutrino-nucleus scattering, and discuss the developments and perspectives of the theoretical approach based on factorisation of the nuclear cross section, which has recently emerged as a promising framework for the description of the variety of processes contributing to the detected signals.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Method for more accurate transmittance measurements of low-angle scattering samples using an integrating sphere with an entry port beam diffuser

For most integrating sphere measurements, the difference in light distribution between a specular reference beam and a diffused sample beam can result in significant errors. The problem becomes especially pronounced in integrating spheres that include a port for reflectance or diffuse transmittance measurements. The port is included in many standard spectrophotometers to facilitate a multipurpose instrument, however, absorption around the port edge can result in a detected signal that is too low. The absorption effect is especially apparent for low-angle scattering samples, because a significant portion of the light is scattered directly onto that edge. In this paper, a method for more accurate transmittance measurements of low-angle light-scattering samples is presented. The method uses a standard integrating sphere spectrophotometer, and the problem with increased absorption around the port edge is addressed by introducing a diffuser between the sample and the integrating sphere during both reference and sample scan. This reduces the discrepancy between the two scans and spreads the scattered light over a greater portion of the sphere wall. The problem with multiple reflections between the sample and diffuser is successfully addressed using a correction factor. The method is tested for two patterned glass samples with low-angle scattering and in both cases the transmittance accuracy is significantly improved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pickless event detection and location: The waveform correlation event detection system (WCEDS) revisited

The standard paradigm for seismic event monitoring breaks the event detection problem down into a series of processing stages that can be categorized at the highest level into station-level processing and network-level processing algorithms (e.g., Le Bras and Wuster (2002)). At the station-level, waveforms are typically processed to detect signals and identify phases, which may subsequently be updated based on network processing. At the network-level, phase picks are associated to form events, which are subsequently located. Furthermore, waveforms are typically directly exploited only at the station-level, while network-level operations rely on earth models to associate and locate the events that generated the phase picks.

58 GEOSCIENCES↗

Denoising Seismic Waveforms Using a Wavelet-Transform-Based Machine-Learning Method

Seismic waveform data recorded at stations can be thought of as a superposition of the signal from a source of interest and noise from other sources. Frequency‐based filtering methods for waveform denoising do not result in desired outcomes when the targeted signal and noise occupy similar frequency bands. Recently, denoising techniques based on deep‐learning convolutional neural networks (CNNs), in which a recorded waveform is decomposed into signal and noise components, have led to improved results. These CNN methods, which use short‐time Fourier transform representations of the time series, provide signal and noise masks for the input waveform. These masks are used to create denoised signal and designaled noise waveforms, respectively. However, advancements in the field of image denoising have shown the benefits of incorporating discrete wavelet transforms (DWTs) into CNN architectures to create multilevel wavelet CNN (MWCNN) models. The MWCNN model preserves the details of the input due to the good time–frequency localization of the DWT. In this report we use a data set of over 382,000 constructed seismograms recorded by the University of Utah Seismograph Stations network to compare the performance of CNN and MWCNN‐based denoising models. Evaluation of both models on constructed test data shows that the MWCNN model outperforms the CNN model in the ability to recover the ground‐truth signal component in terms of both waveform similarity and preservation of amplitude information. Model evaluation of real‐world data shows that both the CNN and MWCNN models outperform standard band‐pass filtering (BPF; average improvement in signal‐to‐noise ratio of 9.6 and 19.7 dB, respectively, with respect to BPF). Evaluation of continuous data suggests the MWCNN denoiser can improve both signal detection capabilities and phase arrival time estimates.

58 GEOSCIENCES↗

Design of a non-invasive laser-based beam profile monitor system for the new Fermilab PIP-II superconducting H- linac

As part of the new Proton Improvement Plan (PIP-II), Fermilab is undertaking the development of a new 800 MeV, 2 mA H- superconducting RF linac to replace its present normal conducting 400 MeV linac. The PIP-II linac consists of a series of superconducting RF cryomodules from 2.1 MeV to 800 MeV. To limit the potential damage to the superconducting RF cavities, PIP-II will utilize non-invasive laser-based monitors (laserwires) to obtain beam profiles via photoionization. This paper will present the design of this PIP-II laserwire system including the picosecond pulsed laser, optical transport line, 13 individual laserwire stations, laser feedback and timing controls. The paper also describes the signal detection system and operation of the profile measurements.

Scarpine, Victor [Fermilab]↗

Indirect searches for dark matter bound state formation and level transitions

Indirect searches for dark matter (DM) have conventionally been applied to the products of DM annihilation or decay. If DM couples to light force carriers, however, it can be captured into bound states via dissipation of energy that may yield detectable signals. We extend the indirect searches to DM bound state formation and transitions between bound levels, and constrain the emission of unstable dark photons. Our results significantly refine the predicted signal flux that could be observed in experiments. As a concrete example, we use Fermi-LAT dwarf spheroidal observations to obtain constraints in terms of the dark photon mass and energy which we use to search for the formation of stable or unstable bound states.

Baldes, Iason↗

Pair production of charged IDM scalars at high energy CLIC

The Compact Linear Collider (CLIC) was proposed as the next energy-frontier infrastructure at CERN, to study e ^+ + e ^- − collisions at three centre-of-mass energy stages: 380,GeV, 1.5,TeV and 3,TeV. The main goal of its high-energy stages is to search for the new physics beyond the Standard Model (SM). The Inert Doublet Model (IDM) is one of the simplest SM extensions and introduces four new scalar particles: H ^\pm ± , A and H; the lightest, H, is stable and hence a natural dark matter (DM) candidate. A set of benchmark points is considered, which are consistent with current theoretical and experimental constraints and promise detectable signals at future colliders. Prospects for observing pair-production of the IDM scalars at CLIC were previously studied using signatures with two leptons in the final state. In the current study, discovery reach for the IDM charged scalar pair-production is considered for the semi-leptonic final state at the two high-energy CLIC stages. Full simulation analysis, based on the current CLIC detector model, is presented for five selected IDM scenarios. Results are then extended to the larger set of benchmarks using the Delphes fast simulation framework. The CLIC detector model for Delphes has been modified to take pile-up contribution from the beam-induced \gamma\gamma γ γ interactions into account, which is crucial for the presented analysis. Results of the study indicate that heavy, charged IDM scalars can be discovered at CLIC for most of the proposed benchmark scenarios, with very high statistical significance.

Klamka, Jan↗

Intelligent Integrated Machining: Handheld XRF for Mapping Zr Coating and Al-6061 Cladding Thickness in RERTR Fuel Elements

An inexpensive commercially available handheld energy dispersive x‐ray fluorescence spectrometer is used to provide a rapid non‐destructive estimate of coating and/or cladding thickness in situ . The portable XRF instrument contains a battery‐operated low‐power polychromatic source coupled with a Peltier‐cooled silicon drift detector; built‐in analysis software based upon the Method of Fundamental Parameters converts measured spectral intensities to elemental concentrations, reported as normalized weight percentages. Using detected signals from elements unique to the base material and coating or cladding materials, calibration curves and associated empirical algorithms for determining the thickness of the high‐purity zirconium coating on an RERTR fuel element prior to cladding with aluminum, and for determining the thickness of the Al‐6061 cladding after HIP for a known zirconium layer thickness, are constructed. For Zr over bare DU‐10Mo, agreement between the measured and the calculated thickness is ± 5% or better. For the multilayer system consisting of Al‐6061 over Zr over Du‐10Mo, agreement between calculated and measured thickness is ± 10‐15% over the thickness range of interest. Simultaneous estimates for the Al cladding and underlying Zr coating can be made using the elemental composition output only when the Mo signal is in the quasi‐static range (corresponding to Al thicknesses of ~15 mils (0.381 mm) and greater) and not so low that measurement error is greater than the signal itself; under these conditions, accuracy is on the order of ±15 – 20%. More accurate determination of both Zr and Al thickness simultaneously may be possible if the count‐rates associated with individual fluorescent lines in the multilayer sample are available rather than just the weight percent composition currently output by the XRF analyzer software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NetMOD Version 2.0 Mathematical Framework

NetMOD ( Net work M onitoring for O ptimal D etection) is a Java-based software package for conducting simulation of seismic, hydroacoustic and infrasonic networks. Network simulations have long been used to study network resilience to station outages and to determine where additional stations are needed to reduce monitoring thresholds. NetMOD makes use of geophysical models to determine the source characteristics, signal attenuation along the path between the source and station, and the performance and noise properties of the station. These geophysical models are combined to simulate the relative amplitudes of signal and noise that are observed at each of the stations. From these signal-to-noise ratios (SNR), the probabilities of signal detection at each station and event detection across the network of stations can be computed given a detection threshold. The purpose of this document is to clearly and comprehensively present the mathematical framework used by NetMOD, the software package developed by Sandia National Laboratories to assess the monitoring capability of ground-based sensor networks. Many of the NetMOD equations used for simulations are inherited from the NetSim network capability assessment package developed in the late 1980s by SAIC (Sereno et al., 1990).

58 GEOSCIENCES↗

Directed assembly of hybrid nanostructures using optically resonant nanotweezers

This represents the final report for this project. Over the course of the project we have made significant progress in photonically driven nano-assembly including: (1) demonstrating the first direct optical tweezer based manipulation of proteins, (2) the ability to apply optical angular torques to microtubuals and other rod-shaped microparticles, (3) direct assembly of hybrid nanostructures comprising of polymeric nanoparticles and carbon nanotubes and, (4) the ability to drive biological reactions (specifically protein aggregation) that are thermodynamically unfavorable by applying localized optical work. These advancements are described in the list of papers provided in section 2.0 of the below. Summary details are provided in prior year annual reports. We have two additional papers which will be submitted shortly based on the work done under this award. An updated publication list will be provided to the program manager when those are accepted. In this report, we report on a new advancement made in the final project year, which uses the nanotweezer technology to perform direct measurements of particle-surface interactions. Briefly, these measurements are important for characterizing the stability and behavior of colloidal and nanoparticle suspensions and current techniques are limited in their ability to measure piconewton scale interaction forces on sub-micrometer particles due to signal detection limits and thermal noise. In this project year we developed a new technique called “Nanophotonic Force Microscopy” which uses the localized region of exponentially decaying, near-field, light to confine small particles close to a surface. From the statistical distribution of the light intensity scattered by the particle the technique maps out the potential well of the trap and directly quantify the repulsive force between the nanoparticle and the surface. The major advantage of the technique is that it can measure forces and energy wells below the thermal noise limit, resolving interaction forces smaller than 1 pN on dielectric particles as small as 100 nm in diameter.

36 MATERIALS SCIENCE↗

Development of a MEMS dual-axis differential capacitance floating element shear stress sensor

A single-axis MEMS wall shear stress sensor with differential capacitive transduction method is produced. Using a synchronous modulation and demodulation interface circuit, the system is capable of making real time measurements of both mean and fluctuating wall shear stress. A sensitivity of 3.44 mV/Pa is achieved, with linearity in response demonstrated up to testing limit of 2 Pa. Minimum detectable signals of 340 μPa at 100 Hz and 120 μPa at 1 kHz are indicated, with a resonance of 3.5 kHz. Multiple full scale wind tunnel tests are performed, producing spectral measurements of turbulent boundary layers in wind speeds ranging up to 0.5 Ma (18 Pa of mean wall shear stress). The compact packaging allows for minimally invasive installation, and has proven relatively robust over multiple testing events. Temperature sensitivity, likely due to poor CTE matching of packaged materials, is an ongoing concern being addressed. These successes are being directly leveraged into a development plan for a dual-axis wall shear stress sensor, capable of producing true vector estimates at the wall.

47 OTHER INSTRUMENTATION↗

IDC Re-Engineering Phase 2 Iteration E2 Use Case Realizations

This architecturally significant use case describes how the System acquires meteorological data to build atmospheric models used in automatic and interactive processing of infrasound data. The System requests the latest available high-resolution global meteorological data from external data centers and puts it into the correct formats for generation of infrasound propagation models. The system moves the meteorological data from Data Acquisition Partition to the Data Processing Partition and stores the meteorological data. The System builds a new atmospheric model based on the meteorological data. This use case is architecturally significant because it describes acquiring meteorological data from various sources and creating dynamic atmospheric transmission model to support the prediction of infrasonic signal detection

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

IdentiFINDER Laboratory Exercise

The identiFINDER2 is an easily portable handheld NaI gamma detector. The IAEA uses the safeguards version of the identiFINDER2 and calls it the HM-5. The HM-5 has built in software to analyze the detection signal specifically for IAEA verification applications.

97 MATHEMATICS AND COMPUTING↗

Evaluation and Uncertainty of a New Method to Detect Suspected Nuclear and WMD Activity: Project Report

The Atmospheric Technology Group at SRNL developed a new method to detect signals from Weapons of Mass Destruction (WMD) activities in a time series of chemical measurements at a downwind location. This method was tested with radioxenon measured in Russia and Japan after the 2013 underground test in North Korea. This LDRD calculated the uncertainty in the method with the measured data and also for a case with the signal reduced to 1/10 its measured value. The research showed that the uncertainty in the calculated probability of origin from the NK test site was small enough to confirm the test. The method was also wellbehaved for small signal strengths.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

PVT Degradation Studies: NMR Analysis

Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. Nuclear magnetic resonance spectroscopy has been used to elucidate the state of water inside the PVT. The deuterium NMR results show that water absorbed by PVT under warm, humid conditions enters several distinct environments, and when the PVT is transferred from incubation to ambient temperature and humidity the water is lost on a time scale of a few hours from these samples. Most of the deuterium NMR peaks can be assigned to bulk liquid water, but almost 35% of the detected signal intensity is contained in a resonance that resembles spectra of water contained in nanometer-scale pores in mesoporous carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final report of a scalable, automated, semipermanent seismic array (SASSA) method for detecting CO 2 extent during geologic CO 2 injection

The scalable, automated, semipermanent seismic array (SASSA) project led and managed by the Energy & Environmental Research Center (EERC) was designed as a 3-year proof-of-concept study to evaluate and demonstrate an innovative application of the seismic method. The concept was to use a sparse surface array of 96 nodal seismic sensors paired with a single, remotely operated active seismic source at a fixed location to monitor for CO 2 saturation changes in a subsurface reservoir by processing the data for time-lapse changes at individual, strategically chosen reservoir reflection points. The combination of autonomous equipment and modern processing algorithms was used to apply the seismic method in a manner different from the normal paradigm of collecting a spatially dense data set to produce an image. It was used instead to monitor individual, strategically chosen reservoir reflection points for detectable signal character changes that could be attributed to the passing of a CO 2 saturation front or, possibly, changes in reservoir pressure. Data collection occurred over the course of 1 year at an oil field undergoing CO 2 injection for enhanced oil recovery (EOR) and focused on four overlapping “five-spot” EOR injector–producer patterns. Selection, procurement, configuration, installation, and testing of project equipment and collection of five baseline data sets were completed in advance of CO 2 injection within the study area. Weekly remote data collection produced 41 incremental time-lapse records for each of the 96 nodes. Validation was provided by two methods: 1) a conventional 2-D seismic line acquired through the center of the study area before injection started and again after the project ended and processed in a time-lapse manner and 2) by CO 2 saturation maps created from reservoir simulations based on injection and production history matching. Interpreted results were encouraging but mixed, with indications of changes likely due to the presence of CO 2 on some node reflection points where and when effects would be expected and noneffects where no CO 2 was expected, while results at some locations where simulation outputs suggested CO 2 should be present were ambiguous. Acquisition noise impacted interpretation of data at several locations. Many lessons learned were generated by the study to inform and improve results on a follow-up study. The ultimate aim of the project was to evaluate whether deployment of a SASSA technology can provide a useful and cost-effective monitoring solution for future CO 2 injection projects. The answer appears to be affirmative, with the expectation that lessons learned applied to future iterations, together with technology advances, will likely result in significant improvements.

58 GEOSCIENCES↗

Reduced graphene oxide as a filament material for thermal ionization mass spectrometry

Isotopic information can be informative as to the intended use and/or production history of special nuclear material. For uranium and plutonium samples, thermal ionization mass spectrometry (TIMS) is the benchmark technique for determining isotope ratio data. Sample utilization in thermal ionization, however, is low with typical ionization efficiencies between 0.1% and 0.5% - i.e., only 0.1% to 0.5% of the sample contributes to the detected signal. One barrier to improving the ionization efficiency is thermodynamic limits related to the work function of the ionization filament. Graphene oxide, having a tunable work function, has the potential to greatly improve ionization efficiencies over Re or W-based filaments. The bulk work function of graphene can be tuned through doping or incorporating metal particulates in the graphene oxide matrix. In the first year of this LDRD project reduced graphene oxide (RGO) filaments were constructed using 3D printing techniques and mated to commercial filament posts. The second year of this LDRD produced ultra-low U background RGO filaments and RGO-composite filaments that are more robust than Re filaments at high temperatures and high vacuum conditions. Preliminary results using a commercial TIMS instrument demonstrate a 500 % ionization enhancement for Uranium when using Re-RGO composite-based filaments over traditional Re filaments when direct loading sample solutions onto filaments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IDC Re-Engineering Phase 2 Iteration E2 Use Case Realizations

This architecturally significant use case describes how the System acquires meteorological data to build atmospheric models used in automatic and interactive processing of infrasound data. The System requests the latest available high-resolution global meteorological data from external data centers and puts it into the correct formats for generation of infrasound propagation models. The system moves the meteorological data from Data Acquisition Partition to the Data Processing Partition and stores the meteorological data. The System builds a new atmospheric model based on the meteorological data. This use case is architecturally significant because it describes acquiring meteorological data from various sources and creating dynamic atmospheric transmission model to support the prediction of infrasonic signal detections.

97 MATHEMATICS AND COMPUTING↗