Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STERILIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Microbial Characterization of Heat Melt Compaction for Treatment of Space Generated Solid Wastes

One treatment process in development for solid waste management in space has been the Trash Compaction Processing System (TCPS). Human space mission wastes typically contain large percentages of contaminated wet solid waste. The Heat Melt Compactor (HMC) is being developed to be a multi-function means of water recovery, volume reduction, and the making safe of contaminant-rich trash with the potential for waste stabilization and/or sterilization. To determine the efficacy of the HMC treatment to kill microorganisms in solid waste and remain biologically stable, testing was conducted on three tiles produced by HMC-Gen 2 at Ames Research Center. Samples were shipped to Kennedy Space Center to test for microbial viability after compaction, determine the bio-stability of the HMC disks during storage (43 days), and assess potential airborne contaminate microbial growth on surfaces at low and high humidity conditions. In addition to the products of solid waste processing technologies, there is a concern that the crew might come into contact with hardware surfaces that have been contaminated by microorganisms during waste processing. The extent of microbial surface contamination of waste processing hardware was determined by surface sample swabbing and analysis for total bacterial and yeast counts and cultivable counts of aerobic and anaerobic bacteria, spore-forming bacteria, and fungi. Results indicate that trash processing increased bacterial counts on the surfaces of the compacter. All but one biological indicator spore strip imbedded in the HMC produced tiles were negative for growth after incubation for five days indicating effective sterilization through the heat melt compaction process. Analysis of core samples as well as surface growth of tiles inoculated with Aspergillus niger fungal spores incubated at three levels of humidity indicate that HMC created tiles did not support the proliferation of bacterial and fungal growth.

Mary E Hummerick↗

ISS External Microorganisms: A Payload to Close Planetary Protection Knowledge Gaps for Crewed Missions

Before NASA or COSPAR is able to set planetary protection requirements for crewed missions to locations like Mars there are a number of critical knowledge gaps that must be addressed (1). One of the most important knowledge gaps is an understanding of microbial leakage from crewed habitats and space suits. Current ECLSS (Environmental Control and Life Support System) and PLSS (Portable Life Support System) requirements do not include any provisions to control microbes that may escape along with vented or leaked gasses. The current generation of NASA space suits can leak at rates as high as 100 cm2 /min. during nominal operation (2). ISS (International Space Station) intentionally vents atmospheric gases like CO2 to maintain habitable conditions for the crew. Furthermore, every time an airlock is used for EVA (extravehicular activity)there is an accompanying release of internal atmosphere. Since it is not possible to sterilize a crewed mission, it is important that we understand what if any microbes are entrained in these vented and leaked products. It is also important to understand if these microbes can survive on exterior surfaces. Recent sampling of the Russian segments of ISS suggest that bacteria and fungi from inside ISS may be capable of surviving on external surfaces(3). NASA is developing an aseptic sampling tool for use during EVA and plans to collect samples from vents on ISS to build on these results. The results of this work will be used to develop planetary protection requirements for vented and leaked gasses from crewed volumes. NASA has developed and tested a tool kit for collecting microbiological samples during EVA(4). This tool kit contains eight commercially available, 23 mm. diameter, foam swabs that can be used to aseptically collect samples while at vacuum. The swabs are individually housed in aluminum canisters that are equipped with 0.2 μm Teflon filters. These filters allow the canisters to equilibrate to pressure changes while preventing microbiological contamination. The canisters will be cleaned and sterilized before flight. Results from ground-based testing indicate that this tool kit is capable of aseptically collecting microbes while at vacuum without becoming contaminated during pressure changes(5). Based on the results of this ground testing we have modified the tool kit to meet NASA safety requirements and improve the ergonomics. We added additional mounting points to the tool kit to give astronauts more options for securing it during use. We also changed the opening mechanism to improve the precision with which swabs can be extracted from the tool kit. We plan to use this kit on an upcoming EVA to collect samples from non-propulsive vents and areas near the U.S. airlock on ISS. These samples will be frozen at -80 ̊C and stored on station until they can be returned to Earth. We will analyze these returned samples using next generation DNA sequencing to determine the community composition and function of external ISS environments. The results of this study will close planetary protection knowledge gaps for crewed missions and will help NASA determine appropriate planetary protection requirements for life support systems. The tool kit will also be useful for collecting aseptic samples on upcoming crewed or robotic missions and could easily be modified to collect samples with organic contamination control requirements as well.

A B Regberg↗

Developing a Tool to Collect Microbiological Samples in Space

We developed and tested a tool to collect aseptic samples during extravehicular activity or space walks. This tool can withstand the extreme temperature (-92 – 90 ˚C) and pressure variations without compromising the sterility of the collection device or the integrity of the sample. Results from ground testing the tool demonstrate that external surfaces of space suits are not sterile and that a wide variety of human associated bacteria and some fungi can survive at least seven hours of exposure to vacuum. These bacteria include non-spore forming organisms like Staphylococcus that are not normally considered extremophiles We plan to use this tool to characterize the exterior of the International Space Station. We expect the results of this work to guide the planetary protection requirements and contamination control strategy for crewed missions to Mars. This tool could also be used to monitor contamination associated with the Artemis missions to the moon or collect aseptic samples robotically in environments that are not suitable for human exploration.

A B Regberg↗

Does the International Space Station Leak DNA? Preliminary Results from the ISS External Microorganisms Payload

Existing crewed spacecraft like the ISS (International Space Station) leak by design. The ISS routinely releases gas to maintain life support systems and when astronauts exit the station to perform space walks. The chemical component of this leakage is well characterized, but the biological components are not. The ISS is not subject to planetary protection requirements, but planned missions to Mars will use similar systems and will be subject to planetary protection requirements. If detectable microorganisms are escaping through vents and or airlocks we may need to redesign our crewed habitats to minimize this type of contamination. To test the hypothesis that microorganisms from inside ISS are detectable on exterior surfaces an astronaut used the ISS External Microorganisms sampling kit (Rucker et al. 2018) to sample exterior surfaces of the ISS during an EVA (Extra Vehicular Activity) in January of 2025. These samples were returned to Earth for DNA extraction and sequencing. We successfully, extracted and sequenced bacterial, fungal and viral DNA from these samples that was not present in the negative controls. These results should help NASA refine the planetary protection requirements for crewed missions. Methods: The samples were collected using sterile, DNA free, buccal swabs (23 mm. diameter) housed in custom canisters. Each canister uses a 0.2 μm Teflon filter to maintain sterility as the caddy, holding 8 swabs moves in and out of vacuum. The astronaut sampled the: 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the Carbon Dioxide Removal Assembly vent, and 6) the Vacuum Exhaust System vent. The seventh swab was exposed to vacuum during the EVA without touching it to a surface. The eighth swab, a negative control, was not opened until the caddy returned to Earth. DNA was extracted from the swabs using a QIamp UCP Pathogen kit and prepared for sequencing on an Aviti (Element Biosciences) sequencer (Arslan et al. 2024). The resulting sequences were analyzed using the EDGE Bioinformatics platform (Li et al. 2017). The sequences were analyzed individually using tools like BLAST, GOTTCHA2, Kraken2, and PanGIA. The data were also assembled into metagenome assembled genomes) using tools like CONCOCT, MaxBin2 and MetaBAT2. Results: We successfully extracted and sequenced bacterial, archaeal, fungal and viral DNA from all seven samples. The handrail swab had the lowest number of reads (768,651) and the airlock thermal cover had the highest number of reads (8,819,230). These samples contain DNA from human associated bacteria (e.g. Crynebacterium riegelii ), fungi (.e.g. Penicillium rubens ), and viruses (e.g Alphapapillomavirus ). Conclusion: Preliminary interpretation suggest that the airlock and the space suits themselves are the largest sources of contaminant DNA. Most if not all of the DNA is from organisms known to be present inside the ISS. Vents attached to life support systems may be a lesser source of biological contamination. Further analysis should help NASA address planetary protection knowledge gaps for crewed missions.

Aaron B Regberg↗

Ozone generator system

An ozone generator system utilizes an electrochemical cell to produce and control ozone concentrations within an enclosure or to supply ozone to a flow conduit. The enclosure may he coupled with a flow conduit that carries the produced ozone to a desired location. An enclosure may be a sterilization chamber and the concentration of ozone produced by the ozone generating system may be sufficient to sterilize articles within the enclosure. An oxygen control electrolyzer cell and/or humidity control electrolyzer cell may be coupled with the enclosure to further control the environment of the enclosure. A humidity control electrolyzer cell may be fluidly coupled with the ozone generator to supply humidity for reaction on the anode of the ozone generator.

Bahar, Bamdad↗

Disinfection system with high throughput and low power requirements

Devices, methods and techniques are disclosed to perform high confidence sterilization of indoor air with low power requirements. In one example aspect, a sterilization device includes a power source, an energy storage coupled to the power source and configured to store electric charges, a set of electrodes arranged in a specified geometry to have a fixed characteristic impedance, and a switch positioned between the energy storage and the set of electrodes. The switch is configured to operate to establish a pulsed electric field on the set of electrodes.

Sampayan, Stephen↗

Latest Results from the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment based at Fermilab, IL, USA, that observes $\nu_\mu(\bar{\nu}_\mu) \to \nu_\mu(\bar{\nu}_\mu)$ disappearance and $\nu_\mu(\bar{\nu}_\mu) \to \nu_e(\bar{\nu}_e)$ appearance oscillations from a beam of neutrninos provided by the NuMI beamline at Fermilab. The experiment is made up of two functionally identical liquid scintillation detectors, both situated 14.6 mrad off-axis to the beam direction and made out of PVC extrusion cells arranged in alternating horizontal and vertical planes. The experiment is sensitive not only to standard three-flavor neutrino oscillations, but also to beyond standard model (BSM) searches such as sterile neutrino and non-standard interaction (NSI) of neutrinos with matter searches. The latest results from 3-flavor neutrino oscillation analysis, the NOvA-T2K joint analysis, searches for sterile neutrinos and non-standard interactions of neutrinos with matter, will be discussed here.

Choudhary, Brajesh [Delhi Tech. U.] (ORCID:0000000↗

KATRIN: status and prospects for the neutrino mass and beyond

Abstract The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T 2 β decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN’s design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.

beyond standard model↗

Long-lived heavy neutral leptons with a displaced shower signature at $\mathrm{CMS}$

We study the LHC discovery potential in the search for heavy neutral leptons (HNL) with a new signature: a displaced shower in the CMS muon detector, giving rise to a large cluster of hits forming a displaced shower. A new Delphes module is used to model the CMS detector response for such displaced decays. We reinterpret a dedicated CMS search for neutral long-lived particles decaying in the CMS muon endcap detectors for the minimal HNL scenario. We demonstrate that this new strategy is particularly sensitive to active-sterile mixings with τ leptons, due to hadronic τ decays. HNL masses between ~ 1–6 GeV can be accessed for mixings as low as |V τN | 2 ~10 -7 , probing unique regions of parameter space in the τ sector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

How to identify different new neutrino oscillation physics scenarios at DUNE

Next generation neutrino oscillation experiments are expected to measure the remaining oscillation parameters with very good precision. They will have unprecedented capabilities to search for new physics that modify oscillations. DUNE, with its broad band beam, good particle identification, and relatively high energies will provide an excellent environment to search for new physics. If deviations from the standard three-flavor oscillation picture are seen however, it is crucial to know which new physics scenario is found so that it can be verified elsewhere and theoretically understood. We investigate several benchmark new physics scenarios by looking at existing long-baseline accelerator neutrino data from NOvA and T2K and determine at what sensitivity DUNE can differentiate among them. We consider sterile neutrinos and both vector and scalar non-standard neutrino interactions, all with new complex phases, the latter of which could conceivably provide absolute neutrino mass scale information. We find that, in many interesting cases, DUNE will have good model discrimination. We also perform a new fit to NOvA and T2K data with scalar NSI.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New physics at the Muon (Synchrotron) Ion Collider: MuSIC for several scales

A Muon (Synchrotron) Ion Collider (MuSIC) can be the successor to the Electron-Ion Collider at Brookhaven National Laboratory, as well as the ideal demonstrator facility for a future multi-TeV Muon Collider. Besides its rich nuclear physics and Standard Model particle physics programs, in this work we show that the MuSIC with a TeV-scale muon beam offers also a unique opportunity to probe New Physics. In particular, the relevant searches have the potential to surpass current experimental limits and explore new regimes of the parameter space for a variety of Beyond the Standard Model scenarios including: lepton-flavor violating leptoquarks, muonphilic vector boson interactions, axion-like particles coupling to photons, and heavy sterile neutrinos. Depending on the particular case, the sensitivity of the searches in the MuSIC may span a wide range of energy scales, namely from sub-GeV particles to the few TeV New Physics mediators. Our analysis demonstrates that the MuSIC can strike a powerful chord in the search for New Physics, thanks to unique combination of features that amplify its capabilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of the performance of event reconstruction algorithms in the JSNS 2 experiment using a 252 Cf calibration source

JSNS 2 investigates short-baseline neutrino oscillations using a 24-meter baseline and a 17-tonne Gd-loaded liquid scintillator target. Accurate event-reconstruction algorithms are crucial for analyzing experimental data. The algorithms undergo meticulous validation through calibration with a 252 Cf source. This paper outlines the methodology and evaluates the reconstruction performance, focusing on neutrino interactions up to approximately 50 MeV for sterile neutrino searches. Both 252 Cf and Michel electron events are studied to evaluate reconstruction accuracy. The analysis concludes that the uncertainty of the fiducial volume, with an appropriate correction, is much less than the requirement of JSNS 2 requirement (10%). Furthermore, the energy resolution is measured to be 3.3 ± 0.1% for the Michel electron endpoint and 4.3 ± 0.1% for the n-Gd peak in the central region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

Reactor antineutrino flux and anomaly

Reactor antineutrinos have played a significant role in establishing the standard model of particle physics and the theory of neutrino oscillations. In this article, we review the reactor antineutrino flux and in particular the reactor antineutrino anomaly (RAA) coined over a decade ago. RAA refers to a deficit of the measured antineutrino inverse beta decay rates at very short-baseline reactor experiments compared to the theoretically improved predictions (i.e. the Huber–Mueller model). Since the resolution of several previous experimental anomalies have led to the discovery of non-zero neutrino mass and mixing, many efforts have been invested to study the origin of RAA both experimentally and theoretically. The progress includes the observation of discrepancies in antineutrino energy spectrum between data and the Huber–Mueller model, the re-evaluation of the Huber–Mueller model uncertainties, the potential isotope-dependent rate deficits, and the better agreement between data and new model predictions using the improved summation method. Importantly, these developments disfavor the hypothesis of a light sterile neutrino as the explanation of RAA and supports the deficiencies of Huber–Mueller model as the origin. Looking forward, more effort from both the theoretical and experimental sides is needed to fully understand the root of RAA and to make accurate predictions of reactor antineutrino flux and energy spectrum for future discoveries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PUFFIn – A user friendly fast interface for calculating and visualizing the dose distribution in materials

This article describes a new graphical user interface that uses the PENELOPE Monte Carlo code to calculate dose distributions in materials. It is named PUFFIn, for the Penelope User-Friendly Fast Interface and was developed as an educational and scoping analysis tool for non-experts in radiation modeling. PUFFIn enables the user to visualize and compare the dose distributions in objects (e.g., sterilized healthcare products) irradiated with cobalt-60 gamma-rays, electron beam (E-beam) or X-rays. From such comparisons, the user can determine the most efficient product and/or packaging designs for any given radiation field – whether for conceptual or existing products and packaging. PUFFIn is distributed in a complete, self-contained package of software, including the PENELOPE radiation transport code, a standard graphics package, and a set of simple exercises. The package is available to any user at no cost and requires a minimal amount of training compared to other similar software. PUFFIn's capabilities are described, as well as validation measurements performed at Texas A&M University E-beam facility and the Aerial E-beam Facility in France.

97 MATHEMATICS AND COMPUTING↗

The HIBEAM instrument at the European spallation source

The European spallation source (ESS) will be the world’s brightest neutron source and will open a new intensity frontier in particle physics. The HIBEAM collaboration aims to exploit the unique potential of the ESS with a dedicated ESS instrument for particle physics which offers world-leading capability in a number of areas. The HIBEAM program includes the first search in thirty years for free neutrons converting to antineutrons and searches for sterile neutrons, ultralight axion dark matter and nonzero neutron electric charge. This paper outlines the capabilities, design, infrastructure, and scientific potential of the HIBEAM program, including its dedicated beamline, neutron optical system, magnetic shielding and control, and detectors for neutrons and antineutrons. Additionally, we discuss the long-term scientific exploitation of HIBEAM, which may include measurements of the neutron electric dipole moment and precision studies of neutron decays.

47 OTHER INSTRUMENTATION↗