Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL CONDITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Geometric adjustments to account for eye eccentricity in processing horizontal and vertical eye and head movement data

Neglecting the eccentric position of the eyes in the head can lead to erroneous interpretation of ocular motor data, particularly for near targets. We discuss the geometric effects that eye eccentricity has on the processing of target-directed eye and head movement data, and we highlight two approaches to processing and interpreting such data. The first approach involves determining the true position of the target with respect to the location of the eyes in space for evaluating the efficacy of gaze, and it allows calculation of retinal error directly from measured eye, head, and target data. The second approach effectively eliminates eye eccentricity effects by adjusting measured eye movement data to yield equivalent responses relative to a specified reference location (such as the center of head rotation). This latter technique can be used to standardize measured eye movement signals, enabling waveforms collected under different experimental conditions to be directly compared, both with the measured target signals and with each other. Mathematical relationships describing these approaches are presented for horizontal and vertical rotations, for both tangential and circumferential display screens, and efforts are made to describe the sensitivity of parameter variations on the calculated results.

NASA Discipline Neuroscience↗

Revisiting the photodissociation dynamics of the phenyl radical

We have reinvestigated the photodissociation dynamics of the phenyl radical at 248 nm and 193 nm via photofragment translational spectroscopy under a variety of experimental conditions aimed at reducing the nascent internal energy of the phenyl radical and eliminating signal from contaminants. Under these optimized conditions, slower translational energy (P(E{sub T})) distributions for H-atom loss were seen at both wavelengths than in previously reported work. At 193 nm, the branching ratio for C{sub 2}H{sub 2} loss vs. H-atom loss was found to be 0.2 ± 0.1, a significantly lower value than was obtained previously in our laboratory. The new branching ratio agrees with calculated Rice-Ramsperger-Kassel-Marcus rate constants, suggesting that the photodissociation of the phenyl radical at 193 nm can be treated using statistical models. The effects of experimental conditions on the P(E{sub T}) distributions and product branching ratios are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Specific features of measuring the isotopic composition of hydrogen ions in ITER plasma by using neutral particle diagnostics under neutral beam injection conditions

Results of numerical simulation of signals from neutral particle analyzers under injection of the heating and diagnostic neutral beams in different operating modes of the ITER tokamak are presented. The distribution functions of fast ions in plasma are simulated, and the corresponding neutral particle fluxes escaping from the plasma along the line of sight of the analyzers are calculated. It is shown that the injection of heating deuterium (D{sup 0}) beams results in the appearance of an intense background signal hampering measurements of the ratio between the densities of deuterium and tritium fuel ions in plasma in the thermal energy range. The injection of a diagnostic hydrogen (H{sup 0}) beam does not affect measurements owing to the high mass resolution of the analyzers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Limiting Magnitude, τ, t eff , and Image Quality in DES Year 1

The Dark Energy Survey (DES) is an astronomical imaging survey being completed with the DECam imager on the Blanco telescope at CTIO. After each night of observing, the DES data management (DM) group performs an initial processing of that night's data, and uses the results to determine which exposures are of acceptable quality, and which need to be repeated. The primary measure by which we declare an image of acceptable quality is $\tau$, a scaling of the exposure time. This is the scale factor that needs to be applied to the open shutter time to reach the same photometric signal to noise ratio for faint point sources under a set of canonical good conditions. These conditions are defined to be seeing resulting in a PSF full width at half maximum (FWHM) of 0.9" and a pre-defined sky brightness which approximates the zenith sky brightness under fully dark conditions. Point source limiting magnitude and signal to noise should therefore vary with t in the same way they vary with exposure time. Measurements of point sources and $\tau$ in the first year of DES data confirm that they do. In the context of DES, the symbol $t_{eff}$ and the expression "effective exposure time" usually refer to the scaling factor, $\tau$, rather than the actual effective exposure time; the "effective exposure time" in this case refers to the effective duration of one second, rather than the effective duration of an exposure.

79 ASTRONOMY AND ASTROPHYSICS↗

Bacterial Tradeoffs in Growth Rate and Extracellular Enzymes

Like larger organisms, bacteria possess traits, or phenotypic characteristics, that influence growth and impact ecosystem processes. Still, it remains unclear how these traits are organized across bacterial lineages. Using 49 bacterial strains isolated from leaf litter in Southern California, we tested the hypothesis that bacterial growth rates trade off against extracellular enzyme investment. We also tested for phylogenetic conservation of these traits under high and low resource conditions represented, respectively, by Luria broth (LB) and a monomer-dominated medium extracted from plant litter. In support of our hypotheses, we found a negative correlation between the maximum growth rate and the total activity of carbon-, nitrogen-, and phosphorus-degrading extracellular enzymes. However, this tradeoff was only observed under high resource conditions. We also found significant phylogenetic signal in maximum growth rate and extracellular enzyme investment under high and low resource conditions. Driven by our bacterial trait data, we proposed three potential life history strategies. Resource acquisition strategists invest heavily in extracellular enzyme production. Growth strategists invest in high growth rates. Bacteria in a third category showed lower potential for enzyme production and growth, so we tentatively classified them as maintenance strategists that may perform better under conditions we did not measure. These strategies were related to bacterial phylogeny, with most growth strategists belonging to the phylum Proteobacteria and most maintenance and resource acquisition strategists belonging to the phylum Actinobacteria. By accounting for extracellular enzyme investment, our proposed life history strategies complement existing frameworks, such as the copiotroph-oligotroph continuum and Grime’s competitorstress tolerator-ruderal triangle. Our results have biogeochemical implications because allocation to extracellular enzymes versus growth or stress tolerance can determine the fate and form of organic matter cycling through surface soil.

59 BASIC BIOLOGICAL SCIENCES↗

Ionospheric Imaging From a Low Earth Orbiter Tracking GPS

Tomographic imaging of the ionosphere is examined using singular value decomposition analysis. The interdependency of the obtainable resolution, the accuracy of the solution and the noise data is explained. A simulation is illustrated where a true 2-D ionospheric structure is generated, and a tomographic inversion of the structure is carried out. Inclusion of data taken in an occultation geometry reveals the strength that is added by these data. The effect of the ionosphere on a GPS signal as viewed by a user in space is examined. Under somewhat strong solar conditions, the absolute bending of the signal is of the order of 0.01 degrees for the L1 signal; the phase advance can be as large as 90 meters.

ionosphere↗

Synchronizer circuits with failure-condition detection and correction

An input signal and a reset signal are provided to respective inputs of a resettable flip-flop. The resettable flip-flop generates an output signal. The output signal transitions from a first logic state to a second logic state in response to corresponding transitions of the input signal and transitions from the second logic state to the first logic state in response to assertion of the reset signal. A warning signal is asserted in response to transitions of the input signal from the second logic state to the first logic state. A logic gate forwards the output signal when the warning signal is de-asserted and provides a signal in the first logic state in response to assertion of the warning signal.

Buckler, Mark↗

Nonlinear photoacoustic spectroscopy of hemoglobin

As light intensity increases in photoacoustic imaging, the saturation of optical absorption and the temperature dependence of the thermal expansion coefficient result in a measurable nonlinear dependence of the photoacoustic (PA) signal on the excitation pulse fluence. Here, under controlled conditions, we investigate the intensity-dependent photoacoustic signals from oxygenated and deoxygenated hemoglobin at varied optical wavelengths and molecular concentrations. The wavelength and concentration dependencies of the nonlinear PA spectrum are found to be significantly greater in oxygenated hemoglobin than in deoxygenated hemoglobin. These effects are further influenced by the hemoglobin concentration. These nonlinear phenomena provide insights into applications of photoacoustics, such as measurements of average inter-molecular distances on a nm scale or with a tuned selection of wavelengths, a more accurate quantitative PA tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Amorphous In–Ga–Zn–O thin-film transistor active pixel sensor x-ray imager for digital breast tomosynthesis

Purpose: The breast cancer detection rate for digital breast tomosynthesis (DBT) is limited by the x-ray image quality. The limiting Nyquist frequency for current DBT systems is around 5 lp/mm, while the fine image details contained in the high spatial frequency region (>5 lp/mm) are lost. Also today the tomosynthesis patient dose is high (0.67–3.52 mGy). To address current issues, in this paper, for the first time, a high-resolution low-dose organic photodetector/amorphous In–Ga–Zn–O thin-film transistor (a-IGZO TFT) active pixel sensor (APS) x-ray imager is proposed for next generation DBT systems. Methods: The indirect x-ray detector is based on a combination of a novel low-cost organic photodiode (OPD) and a cesium iodide-based (CsI:Tl) scintillator. The proposed APS x-ray imager overcomes the difficulty of weak signal detection, when small pixel size and low exposure conditions are used, by an on-pixel signal amplification with a significant charge gain. The electrical performance of a-IGZO TFT APS pixel circuit is investigated by SPICE simulation using modified Rensselaer Polytechnic Institute amorphous silicon (a-Si:H) TFT model. Finally, the noise, detective quantum efficiency (DQE), and resolvability of the complete system are modeled using the cascaded system formalism. Results: The result demonstrates that a large charge gain of 31–122 is achieved for the proposed high-mobility (5–20 cm{sup 2}/V s) amorphous metal-oxide TFT APS. The charge gain is sufficient to eliminate the TFT thermal noise, flicker noise as well as the external readout circuit noise. Moreover, the low TFT (<10{sup −13} A) and OPD (<10{sup −8} A/cm{sup 2}) leakage currents can further reduce the APS noise. Cascaded system analysis shows that the proposed APS imager with a 75 μm pixel pitch can effectively resolve the Nyquist frequency of 6.67 lp/mm, which can be further improved to ∼10 lp/mm if the pixel pitch is reduced to 50 μm. Moreover, the detector entrance exposure per projection can be reduced from 1 to 0.3 mR without a significant reduction of DQE. The signal-to-noise ratio of the a-IGZO APS imager under 0.3 mR x-ray exposure is comparable to that of a-Si:H passive pixel sensor imager under 1 mR, indicating good image quality under low dose. A threefold reduction of current tomosynthesis dose is expected if proposed technology is combined with an advanced DBT image reconstruction method. Conclusions: The proposed a-IGZO APS x-ray imager with a pixel pitch <75 μm is capable to achieve a high spatial frequency (>6.67 lp/mm) and a low dose (<0.4 mGy) in next generation DBT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A very high sensitivity RF pulse profile measurement system.

A technique for characterizing the pulse profile of a radio-frequency (RF) amplifier over a very wide power range under fast-pulsing conditions is presented. A pulse-modulated transmitter is used to drive a device under test (DUT) with a phase-coded signal that allows for an increased measurement range beyond standard techniques. A measurement receiver that samples points on the output pulse power profile and performs the necessary signal processing and coherent pulse integration, improving the detectability of low-power signals, is described. The measurement technique is applied to two sample amplifiers under fast-pulsing conditions with a pulsewidth of 250 ns at 3-GHz carrier frequency. A full measurement range of greater than 160 dB is achieved, extending the current state of the art in pulse-profiling techniques.

42 ENGINEERING↗

In-plane visibility of lesions using breast tomosynthesis and digital mammography

Purpose: The purpose of this work was to evaluate the visibility of simulated lesions in 2D digital mammography (DM) and breast tomosynthesis (BT) images of patients. Methods: Images of the same women were acquired on both a DM system (Mammomat Novation, Siemens Healthcare, Erlangen, Germany) and a BT prototype system adapted from the same type of DM system. Using the geometrical properties of the two systems, simulated lesions were projected and added to each DM image as well as to each BT projection image prior to 3D reconstruction. The same beam quality and approximately the same total absorbed dose to the glandular tissue were used for each breast image acquisition on the two systems. A series of four-alternative forced choice human observer experiments was conducted for each of five simulated lesion diameters: 0.2, 1, 3, 8, and 25 mm. An additional experiment was conducted for the 0.2 mm lesion in BT only at twice the dose level (BT{sub 2x}). Threshold signal was defined as the lesion signal intensity required for a detectability index (d{sup '}) of 2.5. Four medical physicists participated in all experiments. One experiment, consisting of 60 cases, was conducted per test condition (i.e., lesion size and signal combination). Results: For the smallest lesions (0.2 mm), the threshold signal for DM was 21% lower than for BT at equivalent dose levels, and BT{sub 2x} was 26% lower than DM. For the lesions larger than 1 mm, the threshold signal increased linearly (in log space) with the lesion diameter for both DM and BT, with DM requiring around twice the signal as BT. The difference in the threshold signal between BT and DM at each lesion size was statistically significant, except for the 0.2 mm lesion between BT{sub 2x} and DM. Conclusions: The results of this study indicate that low-signal lesions larger than 1.0 mm may be more visible in BT compared to DM, whereas 0.2 mm lesions may be better visualized with DM compared to BT, when compared at equal dose.

60 APPLIED LIFE SCIENCES↗

Resveratrol augments the canonical Wnt signaling pathway in promoting osteoblastic differentiation of multipotent mesenchymal cells

Resveratrol has been shown to possess many health-benefiting effects, including the promotion of bone formation. In this report we investigated the mechanism by which resveratrol promotes osteoblastic differentiation from pluripotent mesenchymal cells. Since Wnt signaling is well documented to induce osteoblastogenesis and bone formation, we characterized the factors involved in Wnt signaling in response to resveratrol treatment. Resveratrol treatment of mesenchymal cells led to an increase in stabilization and nuclear accumulation of {beta}-catenin dose-dependently and time-dependently. As a consequence of the increased nuclear accumulation of {beta}-catenin, the ability to activate transcription of {beta}-catenin-TCF/LEF target genes that are required for osteoblastic differentiation was upregulated. However, resveratrol did not affect the initial step of the Wnt signaling pathway, as resveratrol was as effective in upregulating the activity of {beta}-catenin in cells in which Lrp5 was knocked down as in control cells. In addition, while conditioned medium enriched in Wnt signaling antagonist Dkk1 was able to inhibit Wnt3a-induced {beta}-catenin upregulation, this inhibitory effect can be abolished in resveratrol-treated cells. Furthermore, we showed that the level of glycogen synthase kinase 3{beta} (GSK-3{beta}), which phosphorylates and destabilizes {beta}-catenin, was reduced in response to resveratrol treatment. The phosphorylation of GSK-3{beta} requires extracellular signal-regulated kinase (ERK)1/2. Together, our data indicate that resveratrol promotes osteoblastogenesis and bone formation by augmenting Wnt signaling.

60 APPLIED LIFE SCIENCES↗

Virtual Machine Language 2.1

VML (Virtual Machine Language) is an advanced computing environment that allows spacecraft to operate using mechanisms ranging from simple, time-oriented sequencing to advanced, multicomponent reactive systems. VML has developed in four evolutionary stages. VML 0 is a core execution capability providing multi-threaded command execution, integer data types, and rudimentary branching. VML 1 added named parameterized procedures, extensive polymorphism, data typing, branching, looping issuance of commands using run-time parameters, and named global variables. VML 2 added for loops, data verification, telemetry reaction, and an open flight adaptation architecture. VML 2.1 contains major advances in control flow capabilities for executable state machines. On the resource requirements front, VML 2.1 features a reduced memory footprint in order to fit more capability into modestly sized flight processors, and endian-neutral data access for compatibility with Intel little-endian processors. Sequence packaging has been improved with object-oriented programming constructs and the use of implicit (rather than explicit) time tags on statements. Sequence event detection has been significantly enhanced with multi-variable waiting, which allows a sequence to detect and react to conditions defined by complex expressions with multiple global variables. This multi-variable waiting serves as the basis for implementing parallel rule checking, which in turn, makes possible executable state machines. The new state machine feature in VML 2.1 allows the creation of sophisticated autonomous reactive systems without the need to develop expensive flight software. Users specify named states and transitions, along with the truth conditions required, before taking transitions. Transitions with the same signal name allow separate state machines to coordinate actions: the conditions distributed across all state machines necessary to arm a particular signal are evaluated, and once found true, that signal is raised. The selected signal then causes all identically named transitions in all present state machines to be taken simultaneously. VML 2.1 has relevance to all potential space missions, both manned and unmanned. It was under consideration for use on Orion.

Riedel, Joseph E.↗

Method and system for monitoring and displaying engine performance parameters

The invention is a method and system for monitoring and directly displaying the actual thrust produced by a jet aircraft engine under determined operating conditions and the available thrust and predicted (commanded) thrust of a functional model of an ideal engine under the same determined operating conditions. A first set of actual value output signals representative of a plurality of actual performance parameters of the engine under the determined operating conditions is generated and compared with a second set of predicted value output signals representative of the predicted value of corresponding performance parameters of a functional model of the engine under the determined operating conditions to produce a third set of difference value output signals within a range of normal, caution, or warning limit values. A thrust indicator displays when any one of the actual value output signals is in the warning range while shaping function means shape each of the respective difference output signals as each approaches the limit of the respective normal, caution, and warning range limits.

Abbott, Terence S.↗

Improving the Molecular Ion Signal Intensity for In Situ Liquid SIMS Analysis

In situ liquid secondary ion mass spectrometry (SIMS) enabled by system for analysis at the liquid vacuum interface (SALVI) has proven to be a promising new tool to provide molecular information at solid–liquid and liquid–vacuum interfaces. However, the initial data showed that useful signals in positive ion spectra are too weak to be meaningful in most cases. In addition, it is difficult to obtain strong negative molecular ion signals when m/z>200. These two drawbacks have been the biggest obstacle towards practical use of this new analytical approach. In this study, we report that strong and reliable positive and negative molecular signals are achievable after optimizing the SIMS experimental conditions. Four model systems, including a 1,8-diazabicycloundec-7-ene (DBU)-base switchable ionic liquid, a live Shewanella oneidensis biofilm, a hydrated mammalian epithelia cell, and an electrolyte popularly used in Li ion batteries were studied. A signal enhancement of about two orders of magnitude was obtained in comparison with non-optimized conditions. Therefore, molecular ion signal intensity has become very acceptable to use for in situ liquid SIMS to study solid–liquid and liquid–vacuum interfaces.

36 MATERIALS SCIENCE↗

Modification of the collective Thomson scattering radiometer in the search for parametric decay on TEXTOR

Strong scattering of high-power millimeter waves at 140 GHz has been shown to take place in heating and current-drive experiments at TEXTOR when a tearing mode is present in the plasma. The scattering signal is at present supposed to be generated by the parametric decay instability. Here we describe the heterodyne detection system used to characterize the newly discovered signal measured at TEXTOR, and we present spectral shapes in which the signal can appear under different conditions. The radiation is collected by the receiver through a quasi-optical transmission line that is independent of the electron cyclotron resonance heating transmission line, and so the scattering geometry is variable. The signal is detected with 42 frequency channels ranging from 136 to 142 GHz. We demonstrate that the large signal does not originate from gyrotron spurious radiation. The measured signal agrees well with independent backscattering radiometer data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of multichannel intermediate frequency system for electron cyclotron emission radiometer on KSTAR Tokamak

Plasma experiments on KSTAR are scheduled to start up this year (2008). We have developed an electron cyclotron emission (ECE) radiometer to measure the radial electron temperature profiles in KSTAR experiments. The radiometer system consists, briefly, of two downconversion stages, amplifiers, bandpass filter banks, and video detectors. These components are made commercially or developed in house. The system detects ECE power in the frequency range from 110 to 196 GHz, the detected signal being resolved by means of 48 frequency windows. Before installation of this system on KSTAR, we installed a part of this system on large helical device (LHD) to study the system under similar plasma conditions. In this experiment, the signal amplitude, considered to be proportional to the electron temperature, is measured. The time-dependent traces of the electron temperature measured by this radiometer are in good agreement with those provided by the LHD Michelson spectrometer. The system noise level which limits the minimum measurable temperature (converted to the electron temperature) is about 30 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Tuning of Seismic Signal Detector Trigger Levels for Local Networks

The quality of automatic signal detections from sensor networks depends on individual detector trigger levels (TLs) from each sensor. The largely manual process of identifying effective TLs is painstaking and does not guarantee optimal configuration settings, yet achieving superior automatic detection of signals and ultimately, events, is closely related to these parameters. In this paper, we present a Dynamic Detector Tuning (DDT) system that automatically adjusts effective TL settings for signal detectors to the current state of the environment by leveraging cooperation within a local neighborhood of network sensors. After a stabilization period, the DDT algorithm can adapt in near-real time to changing conditions and automatically tune a signal detector to identify (detect) signals from only events of interest. Our current work focuses on reducing false signal detections early in the seismic signal processing pipeline, which leads to fewer false events and has a significant impact on reducing analyst time and effort. This system provides an important new method to automatically tune detector TLs for a network of sensors and is applicable to both existing sensor performance boosting and new sensor deployment. Finally, with ground truth on detections from a local neighborhood of seismic sensors within a network monitoring the Mount Erebus volcano in Antarctica, we show that DDT reduces the number of false detections by 18% and the number of missed detections by 11% when compared with optimal fixed TLs for all sensors.

58 GEOSCIENCES↗