Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Spectroscopic research of Lambda hypernuclei up to medium-heavy mass region with the (e,e'K + ) reaction

In 2009 (August-November), the E05-115 experiment was carried out at JLab to investigate L hypernuclei in the wide mass region up to A = 52 ($7\atop{Λ}$He, $10\atop{Λ}$Be, $12\atop{Λ}$B and $52\atop{Λ}$V) with the (e,e'K + ) reaction. This is the first attempt to investigate a medium heavy L hypernucleus with the (e,e'K + ) reaction. Experimentally, it is difficult to measure heavier L hypernuclei as background rates of particles which originate from electromagnetic processes are roughly in proportion to Z2 (Z: target proton number) in the (e,e'K + ) experiment. To perform the experiment, many experimental techniques have been developed and introduced such as optimization of the electron spectrometer configuration (tilt method), clean kaon identification, particle tracking under high multiplicity environment, precise energy scale calibration and so on. In the present thesis, experimental results of the elementary process of p(e,e'K + )L, L hypernuclei of $7\atop{Λ}$He, $10\atop{Λ}$Be, $12\atop{Λ}$B and $52\atop{Λ}$V are shown. Elementary processes of the electroproduction of L and Σ 0 , p(e,e'K + )L, Σ 0 were used for the absolute energy scale calibration of our spectrometer systems. A careful Monte Carlo simulation shows that the binding energy can be obtained with a systematic error of 0.11 MeV with our energy scale calibration method. A study of the elementary process of L is important to understand L hypernuclei as it is essential for theoretical calculations of L hypernuclei. The differential cross section of the p(e,e'K + )L reaction at the small K + scattering angle (theta-CM/gamma-K approx. 15.5°), the small Q 2 (approx 0.01 [GeV/c] 2 ) and the total energy of W = 1.92 GeV, where no experimental data exists was obtained to be 235 ± 13$+28\atop{-24}$ nb/sr. The ground state (1/2 + ) binding energy of $7\atop{Λ}$He was already measured in JLab E01-011 (2005). In the present work, the binding energy of 1/2 + state was determined to be B Λ = 5.55 ± 0.10 ±0.11 MeV with five times more statistic and smaller systematic errors than those of the previous experiment. The ground state binding energy is important to test the phe- nomenologically introduced CSB (Charge Symmetry Breaking) LN interaction for A = 7, T = 1 hypernuclear systems. In addition, a peak which is interpreted as 3/2 + and 5/2 + states was measured to be B Λ = 3.65 ± 0.20 ±0.11 MeV with sufficient statistic for the first time. Only three events of the ground state of $10\atop{Λ}$ Be had been observed in the emulsion experiments. The present experiment is the first spectroscopic measurement of 10/L-Be, and the detailed structures have been successfully measured for the first time. About three times better energy resolution was achieved in the present experiment (0.78 MeV in FWHM) than that of the mirror L hy- pernucleus, $10\atop{Λ}$B (2.2 MeV in FWHM) which was measured in the (π + ,K + ) experiment at KEK. The result of the ground state binding energy was obtained to be B Λ = 8.55 ± 0.07 ± 0.11 MeV which serves also to discuss about the CSB effect in the LN interaction. $12\atop{Λ}$B has been measured with the world best energy resolution of 0:5 MeV (FWHM) among the reaction spectroscopy of L hypernuclei. The results of $12\atop{Λ}$B are compared with the experimental results in the previous experiments to confirm the consistency. Furthermore, the obtained ground state binding energies of $12\atop{Λ}$B (B Λ = 11.38 ± 0.02 ± 0.11 MeV) and $52\atop{Λ}$V (B Λ = 21.88 ± 0.59 ± 0.11 MeV) indicate that the reported value of 12/L-C which has been used as a reference of binding energy measurements for the (π + ,K + ) experiments would be shallower by ~ 0.5 MeV. A pilot study for investigation in the medium-heavy mass region with the (e,e'K + ) experiment was performed by measuring $52\atop{Λ}$V. The ground state binding energy of $52\atop{Λ}$V has been measured, overcoming high multiplicity environment. The results are discussed with the ex- perimental results of 51/L-V measured at KEK. The present result is the first measurement of L's binding energy of the ground state without the emulsion reference in the medium-heavy mass region, which could be a substantial improvement in the information needed for understanding the single particle potential of L. In the present experiment, L hypernuclear measurement with a small systematic error of ~ 0.1 MeV by the (e,e'K + ) reaction has been established. Moreover, the present work opened a door to the heavier L hypernuclear measurement with the (e,e'K + ) reaction in the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement Error Variance Estimation in Gamma-Spectroscopy Data using FRAM

The FRAM gamma-ray isotopic analysis code has recently been applied to four Pu data sets and four U data sets, each with relatively well-characterized standard items, in order to estimate the variances of random errors and of item-specific systematic errors. Assay results are available for Pu238, Pu239, Pu240, Pu241, Pu242 (operator entered, not independently measured), Am241, Specific Power, and Pu240eff. For the four U data sets, results are available for the measurands U234, U235, U236 (operator entered, not independently measured), and U238. For example, in Pu data set 1, there are 33 standard reference Pu items, which have well-known nominal/true values (except for a few items). FRAM was used to make approximately 15 repeat measurements for each of the 33 items, so empirical standard deviations can be calculated. In addition, FRAM internally estimates its random error variance using propagation of variance. This paper applies analysis of variance (ANOVA) to separately estimate the repeatability standard deviation and the standard deviation of the item-specific biases δ s in each of the 8 data sets.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DUK - A Fast and Efficient Kmer Based Sequence Matching Tool

A new tool, DUK, is developed to perform matching task. Matching is to find whether a query sequence partially or totally matches given reference sequences or not. Matching is similar to alignment. Indeed many traditional analysis tasks like contaminant removal use alignment tools. But for matching, there is no need to know which bases of a query sequence matches which position of a reference sequence, it only need know whether there exists a match or not. This subtle difference can make matching task much faster than alignment. DUK is accurate, versatile, fast, and has efficient memory usage. It uses Kmer hashing method to index reference sequences and Poisson model to calculate p-value. DUK is carefully implemented in C++ in object oriented design. The resulted classes can also be used to develop other tools quickly. DUK have been widely used in JGI for a wide range of applications such as contaminant removal, organelle genome separation, and assembly refinement. Many real applications and simulated dataset demonstrate its power.

59 BASIC BIOLOGICAL SCIENCES↗

Rayleigh wave numerical dispersion in a 3D finite-difference algorithm.

A Rayleigh wave propagates laterally without dispersion in the vicinity of the plane stress-free surface of a homogeneous and isotropic elastic halfspace. The phase speed is independent of frequency and depends only on the Poisson ratio of the medium. However, after temporal and spatial discretization, a Rayleigh wave simulated by a 3D staggered-grid finite-difference (FD) seismic wave propagation algorithm suffers from frequency- and direction-dependent numerical dispersion. The magnitude of this dispersion depends critically on FD algorithm implementation details. Nevertheless, proper gridding can control numerical dispersion to within an acceptable level, leading to accurate Rayleigh wave simulations. Many investigators have derived dispersion relations appropriate for body wave propagation by various FD algorithms. However, the situation for surface waves is less well-studied. We have devised a numerical search procedure to estimate Rayleigh phase speed and group speed curves for 3D O(2,2) and O(2,4) staggered-grid FD algorithms. In contrast with the continuous time-space situation (where phase speed is obtained by extracting the appropriate root of the Rayleigh cubic), we cannot develop a closed-form mathematical formula governing the phase speed. Rather, we numerically seek the particular phase speed that leads to a solution of the discrete wave propagation equations, while holding medium properties, frequency, horizontal propagation direction, and gridding intervals fixed. Group speed is then obtained by numerically differentiating the phase speed with respect to frequency. The problem is formulated for an explicit stress-free surface positioned at two different levels within the staggered spatial grid. Additionally, an interesting variant involving zero-valued medium properties above the surface is addressed. We refer to the latter as an implicit free surface. Our preliminary conclusion is that an explicit free surface, implemented with O(4) spatial FD operators and positioned at the level of the compressional stress components, leads to superior numerical dispersion performance. Phase speeds measured from fixed-frequency synthetic seismograms agree very well with the numerical predictions.

58 GEOSCIENCES↗

Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology

Purpose: Many centers aim to plan liver transarterial radioembolization (TARE) with dosimetry, even without CT-based attenuation correction (AC), or with unoptimized scatter correction (SC) methods. This work investigates the impact of presence vs absence of such corrections, and limited spatial resolution, on 3D dosimetry for TARE. Methods: Three voxelized phantoms were derived from CT images of real patients with different body sizes. Simulations of {sup 99m}Tc-SPECT projections were performed with the SIMIND code, assuming three activity distributions in the liver: uniform, inside a “liver’s segment,” or distributing multiple uptaking nodules (“nonuniform liver”), with a tumoral liver/healthy parenchyma ratio of 5:1. Projection data were reconstructed by a commercial workstation, with OSEM protocol not specifically optimized for dosimetry (spatial resolution of 12.6 mm), with/without SC (optimized, or with parameters predefined by the manufacturer; dual energy window), and with/without AC. Activity in voxels was calculated by a relative calibration, assuming identical microspheres and {sup 99m}Tc-SPECT counts spatial distribution. 3D dose distributions were calculated by convolution with {sup 90}Y voxel S-values, assuming permanent trapping of microspheres. Cumulative dose-volume histograms in lesions and healthy parenchyma from different reconstructions were compared with those obtained from the reference biodistribution (the “gold standard,” GS), assessing differences for D95%, D70%, and D50% (i.e., minimum value of the absorbed dose to a percentage of the irradiated volume). γ tool analysis with tolerance of 3%/13 mm was used to evaluate the agreement between GS and simulated cases. The influence of deep-breathing was studied, blurring the reference biodistributions with a 3D anisotropic gaussian kernel, and performing the simulations once again. Results: Differences of the dosimetric indicators were noticeable in some cases, always negative for lesions and distributed around zero for parenchyma. Application of AC and SC reduced systematically the differences for lesions by 5%–14% for a liver segment, and by 7%–12% for a nonuniform liver. For parenchyma, the data trend was less clear, but the overall range of variability passed from −10%/40% for a liver segment, and −10%/20% for a nonuniform liver, to −13%/6% in both cases. Applying AC, SC with preset parameters gave similar results to optimized SC, as confirmed by γ tool analysis. Moreover, γ analysis confirmed that solely AC and SC are not sufficient to obtain accurate 3D dose distribution. With breathing, the accuracy worsened severely for all dosimetric indicators, above all for lesions: with AC and optimized SC, −38%/−13% in liver’s segment, −61%/−40% in the nonuniform liver. For parenchyma, D50% resulted always less sensitive to breathing and sub-optimal correction methods (difference overall range: −7%/13%). Conclusions: Reconstruction protocol optimization, AC, SC, PVE and respiratory motion corrections should be implemented to obtain the best possible dosimetric accuracy. On the other side, thanks to the relative calibration, D50% inaccuracy for the healthy parenchyma from absence of AC was less than expected, while the optimization of SC was scarcely influent. The relative calibration therefore allows to perform TARE planning, basing on D50% for the healthy parenchyma, even without AC or with suboptimal corrections, rather than rely on nondosimetric methods.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-03: Accurate Tissue Characterization for Monte Carlo Dose Calculation Using Dual-and Multi-Energy CT Data

Purpose: To develop a general method for human tissue characterization with dual-and multi-energy CT and evaluate its performance in determining elemental compositions and the associated proton stopping power relative to water (SPR) and photon mass absorption coefficients (EAC). Methods: Principal component analysis is used to extract an optimal basis of virtual materials from a reference dataset of tissues. These principal components (PC) are used to perform two-material decomposition using simulated DECT data. The elemental mass fraction and the electron density in each tissue is retrieved by measuring the fraction of each PC. A stoichiometric calibration method is adapted to the technique to make it suitable for clinical use. The present approach is compared with two others: parametrization and three-material decomposition using the water-lipid-protein (WLP) triplet. Results: Monte Carlo simulations using TOPAS for four reference tissues shows that characterizing them with only two PC is enough to get a submillimetric precision on proton range prediction. Based on the simulated DECT data of 43 references tissues, the proposed method is in agreement with theoretical values of protons SPR and low-kV EAC with a RMS error of 0.11% and 0.35%, respectively. In comparison, parametrization and WLP respectively yield RMS errors of 0.13% and 0.29% on SPR, and 2.72% and 2.19% on EAC. Furthermore, the proposed approach shows potential applications for spectral CT. Using five PC and five energy bins reduces the SPR RMS error to 0.03%. Conclusion: The proposed method shows good performance in determining elemental compositions from DECT data and physical quantities relevant to radiotherapy dose calculation and generally shows better accuracy and unbiased results compared to reference methods. The proposed method is particularly suitable for Monte Carlo calculations and shows promise in using more than two energies to characterize human tissue with CT.

60 APPLIED LIFE SCIENCES↗

Geochemical Data Package for Performance Assessment Calculations Related to the Savannah River Site

The Savannah River Site (SRS) disposes of low-level radioactive waste (LLW) and stabilizes high-level radioactive waste (HLW) tanks in the subsurface environment. Calculations used to establish the radiological limits of these facilities are referred to as Performance Assessments (PA), Special Analyses (SA), and Composite Analyses (CA). The objective of this document is to revise existing geochemical input values used for these calculations. This work builds on earlier compilations of geochemical data (2007, 2010), referred to a geochemical data packages. This work is being conducted as part of the on-going maintenance program of the SRS PA programs that periodically updates calculations and data packages when new information becomes available. Because application of values without full understanding of their original purpose may lead to misuse, this document also provides the geochemical conceptual model, the approach used for selecting the values, the justification for selecting data, and the assumptions made to assure that the conceptual and numerical geochemical models are reasonably conservative (i.e., bias the recommended input values to reflect conditions that will tend to predict the maximum risk to the hypothetical recipient). This document provides 1088 input parameters for geochemical parameters describing transport processes for 64 elements (>740 radioisotopes) potentially occurring within eight subsurface disposal or tank closure areas: Slit Trenches (ST), Engineered Trenches (ET), Low Activity Waste Vault (LAWV), Intermediate Level (ILV) Vaults, Naval Reactor Component Disposal Areas (NRCDA), Components-in-Grout (CIG) Trenches, Saltstone Facility, and Closed Liquid Waste Tanks. The geochemical parameters described here are the distribution coefficient, Kd value, apparent solubility concentration, k s value, and the cementitious leachate impact factor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Short-Term Frequency Response of a DFIG-Based Wind Turbine Generator for Rapid Frequency Stabilization

This paper proposes a short-term frequency-response scheme of a doubly-fed induction generator (DFIG)-based wind turbine generator (WTG) for improving rotor speed recovery and frequency nadir. In the energy-releasing period, to improve the frequency nadir and rotor speed convergence by releasing a large amount of kinetic energy stored in the rotating masses in a DFIG-based WTG, the power reference is increased up to the torque limit referred to the power and reduces along with it for a predefined period which is determined based on the occurrence time of the frequency nadir in a power grid. Then, the reference decreases so that the rotor speed is forced to be converged to the preset value in the stable operating region of the rotor speed. In the energy-absorbing period, to quickly recover the rotor speed, the reference smoothly decreases with the rotor speed and time during a predefined period until it intersects with the maximum power point tracking curve. The simulation results demonstrate that the proposed scheme successfully achieves rapid frequency stabilization with the improved frequency nadir under various wind conditions based on the IEEE 14-bus system.

17 WIND ENERGY↗

Analytical Examination of the Relationship between Fuel Properties, Engine Efficiency, and R Factor Values

The variability in gasoline energy content, though most frequently not a consumer concern, is an issue of concern for vehicle manufacturers in demonstrating compliance with regulatory requirements. Advancements in both vehicle technology, test methodology, and fuel formulations have increased the level of visibility and concern with regard to the energy content of fuels used for regulatory testing. The R factor was introduced into fuel economy calculations for vehicle certification in the late 1980s as a means of addressing batch-to-batch variations in the heating value of certification fuels and the resulting variations in fuel economy results. While previous studies have investigated values of the R factor for modern vehicles through experimentation, subsequent engine studies have made clear that it is difficult to distinguish between the confounding factors that influence engine efficiency when R is being studied experimentally. The proposed study focuses on an analytical approach to examining the heating value effects so that R values can be studied without the influence of confounding effects of other fuel properties. Data previously published for a 1.6-liter naturally-aspirated engine are used as a case study to explore the relationship between fuel properties, engine efficiency, and R factor values. The results demonstrate that engine efficiency does vary as a result of differences in heating value among fuels, although other factors that are variant among fuels also impact efficiency. R factor values depend not only on the difference in heating value between two fuels, but also on the directionality of the change and on engine operating loads. The latter is integral because the reference engine efficiency point is itself a function of the engine operating condition. R factor values asymptotically approach unity as engine operating load increases. Increasing engine efficiency causes R values for a given test fuel to increase. A method is presented for which the test data from only one fuel is required to establish R factor values for individual vehicles and test cycles. An alternative method of establishing Indolene fuel economy equivalency for certification tests is also discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Using Photon Activation Analysis To Determine Concentrations Of Unknown Components In Reference Materials

Using certified multi-element reference materials for instrumental analyses one frequently is confronted with the embarrassing fact that the concentration of some desired elements are not given in the respective certificate, nonetheless are detectable, e.g. by photon activation analysis (PAA). However, these elements might be determinable with sufficient quality of the results using scaling parameters and the well-known quantities of a reference element within the reference material itself. Scaling parameters include: activation threshold energy, Giant Dipole Resonance (GDR) peak and endpoint energy of the bremsstrahlung continuum; integrated photo-nuclear cross sections for the isotopes of the reference element; bremsstrahlung continuum integral; target thickness; photon flux density. Photo-nuclear cross sections from the unreferenced elements must be known, too. With these quantities, the integral was obtained for both the known and unknown elements resulting in an inference of the concentration of the unreported element based upon the reported value, thus also the concentration of the unreferenced element in the reference material. A similar method to determine elements using the basic nuclear and experimental data has been developed for thermal neutron activation analysis some time ago (k{sub 0} Method).

07 ISOTOPE AND RADIATION SOURCES↗

Model for Deriving the Direct Normal and Diffuse Horizontal Irradiance from the Global Tilted Irradiance

We developed a separation model for deriving the direct normal irradiance (DNI) and the diffuse horizontal irradiance (DHI) from the global tilted irradiance (GTI). The model is based on the DIRINT model, but substitutes the use of the GTI in place of the global horizontal irradiance (GHI) for determining the global clearness index (Kt). Additionally, an iterative method is used to adjust Kt to improve the derived values of the DNI and the DHI. The model is referred to as the GTI-DIRINT model. When using for model input the GTI measured with a pyranometer tilted at a small angle from the horizontal (10°), the deviations between the measured DNI and DHI and the GTI-DIRINT-modeled DNI and DHI were essentially the same as those for the DIRINT model when using the GHI for model input. Increasing the tilt angle from horizontal (as great as 44° for Eugene, Oregon) increased the deviations between the modeled and measured DNI and DHI, but our results were still reasonable. The GTI-DIRINT model provides reasonable values of DNI and DHI from the GTI, and if they are subsequently used with the Perez tilted surface model to model the GTI for orientations within 30° of the azimuth and tilt of the GTI used for model input, the result is as good or better than may be obtained when using a measured DNI and DHI, and without their significant instrumentation cost.

14 SOLAR ENERGY↗

Towards a theory of economic value for modeling and simulation: incremental cost of parallel simulation (wip)

A useful perspective on the economic value of simulation in engineering comes from considering the role simulation plays in constructing a system. We propose a conceptual model that combines an embryonic concept of the value of an information bit with cost estimation tools used in software engineering. The model provides an economic justification for the common conception that models should be built to address specific questions rather than to comprehensively represent a referent system. Extending these ideas, we offer a model for the incremental value of parallel execution to explain why simulation applications that take advantage of sophisticated parallel discrete event simulation tools form a relatively narrow niche despite the ubiquity of parallel computing hardware. The proposed model enables us to bring value of information criteria into model development and to make predictions about the future of parallel simulation applications.

Nutaro, James J↗

Correlation of 3T multiparametric prostate MRI using prostate imaging reporting and data system (PIRADS) version 2 with biopsy as reference standard

Objective: To correlate the findings on 3T multiparametric prostate MRI using PIRADS version 2 with prostate biopsy results as the standard of reference. Materials and methods: 134 consecutive treatment naive patients (mean age 64 years, range 41–82 years) underwent MRI-directed prostate biopsy. MRI–TRUS fusion biopsy was used for 77 (77/134 = 57.5%) patients, cognitive fusion for 51 (51/134 = 38.0%) patients, and 6 patients (6/134 = 4.5%) without a target nodule had systematic biopsy only. Out of the 1676 biopsy sites, 237 (237/1676 = 14.1%) were positive on MRI for a PIRADS 3, 4, or 5 nodule. Fifty-eight (58/134, 43.3%) patients had clinically significant prostate cancer (csPCa). The findings on MRI using PIRADS version 2 were correlated with the biopsy results. Results: The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of PIRADS ≥ 3 for csPCa were 89%, 76.5%, 89.7%, 31.7%, and 98.4%, respectively. The detection rates of csPCa for PIRADS 3, 4, and 5 nodules were 6.1% (4/66), 33.3% (42/126), and 64.4% (29/45), respectively. MRI did not identify a nodule in 23/1676 (1.4%) biopsy sites that contained csPCa. The MRI reader, biopsy operator, method of fusion biopsy, and zonal location of prostate nodule did not significantly affect the odds of having a biopsy result positive for csPCa. Conclusion: PIRADS ≥ 3 had high specificity and high negative predictive value for csPCa using biopsy results as the standard of reference. The presence of csPCa from a biopsy site was highly unlikely in the absence of a corresponding PIRADS ≥ 3 nodule.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elemental ratio measurements of organic compounds using aerosol mass spectrometry: characterization, improved calibration, and implications

Elemental compositions of organic aerosol (OA) particles provide useful constraints on OA sources, chemical evolution, and effects. The Aerodyne high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS) is widely used to measure OA elemental composition. This study evaluates AMS measurements of atomic oxygen-to-carbon (O : C), hydrogen-to-carbon (H : C), and organic mass-to-organic carbon (OM : OC) ratios, and of carbon oxidation state ( OS C ) for a vastly expanded laboratory data set of multifunctional oxidized OA standards. For the expanded standard data set, the method introduced by Aiken et al. (2008), which uses experimentally measured ion intensities at all ions to determine elemental ratios (referred to here as "Aiken-Explicit"), reproduces known O : C and H : C ratio values within 20% (average absolute value of relative errors) and 12%, respectively. The more commonly used method, which uses empirically estimated H 2 O + and CO + ion intensities to avoid gas phase air interferences at these ions (referred to here as "Aiken-Ambient"), reproduces O : C and H : C of multifunctional oxidized species within 28 and 14% of known values. The values from the latter method are systematically biased low, however, with larger biases observed for alcohols and simple diacids. A detailed examination of the H 2 O + , CO + , and CO 2 + fragments in the high-resolution mass spectra of the standard compounds indicates that the Aiken-Ambient method underestimates the CO + and especially H 2 O + produced from many oxidized species. Combined AMS–vacuum ultraviolet (VUV) ionization measurements indicate that these ions are produced by dehydration and decarboxylation on the AMS vaporizer (usually operated at 600 °C). Thermal decomposition is observed to be efficient at vaporizer temperatures down to 200 °C. These results are used together to develop an "Improved-Ambient" elemental analysis method for AMS spectra measured in air. The Improved-Ambient method uses specific ion fragments as markers to correct for molecular functionality-dependent systematic biases and reproduces known O : C (H : C) ratios of individual oxidized standards within 28% (13%) of the known molecular values. The error in Improved-Ambient O : C (H : C) values is smaller for theoretical standard mixtures of the oxidized organic standards, which are more representative of the complex mix of species present in ambient OA. For ambient OA, the Improved-Ambient method produces O : C (H : C) values that are 27% (11%) larger than previously published Aiken-Ambient values; a corresponding increase of 9% is observed for OM : OC values. These results imply that ambient OA has a higher relative oxygen content than previously estimated. The OS C values calculated for ambient OA by the two methods agree well, however (average relative difference of 0.06 OS C units). This indicates that OS C is a more robust metric of oxidation than O : C, likely since OS C is not affected by hydration or dehydration, either in the atmosphere or during analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TeMPI Shim

This is the manual for the TeMPI Shim library, whose goal is to facilitate scientific apps being loosely coupled through MPI. TeMPI Shim can be used to create and manage Message Passing Interface (MPI, see [MPI]) Communicators for Single Program, Multiple Data (SPMD, see [SPMD]) and Multiple Programs, Multiple Data (MPMD, see [MPMD]) workflows. MPI provides the MPI_APPNUM command number to each of the processes within its context. This number, starting at 0, is the application number being executed. In a case where 3 applications are being run in MPMD mode, there would be MPI_APPNUM values of 0, 1, and 2. TeMPI Shim creates intra- and inter-communicators between each pair of MPI_APPNUM values. In the aforementioned case, application 0 would have intra- and inter-communicators to speak to itself, application 1, and application 2. This is replicated for each of the applications. Additionally, TeMPI Shim creates intra- and inter-communicators for the first MPI rank of each application to directly communicate only with each other. Finally, TeMPI Shim creates its own copy of the default world communicator, i.e., MPI_COMM_WORLD. In the case where there is only a single application, it will have the communicators to only speak with itself. TeMPI Shim is useful in this case since it is considered good practice for MPI applications to copy the default world communicator and reference this copy (see [Duplicate World]_) anyways. Ultimately, it provides value independent of the number of applications present.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

New NBL Pu Isotopic Standards C137A and C136A as Working Reference Materials for Radiochronometry in Nuclear Forensics

Lawrence Livermore National Laboratory (LLNL) and the NBL Program Office (NBL PO) are collaborating on production of purified sub-units of the former NBS 936, 937 and 938 plutonium isotopic reference materials, which will be certified for plutonium isotopic composition and sold as certified reference materials (CRMs) C136A, C137A, and C138A, respectively. These reference materials are used throughout the United States and international community as standards for isotopic measurement method calibration and quality control and were first produced over 50 years ago. To reduce quantities of in-grown daughter products and potentially enable their use as Pu radiochronometry reference materials, the materials undergo a two-stage anion exchange purification to significantly reduce the quantities of U, Am, and Np in the source material. The purified Pu is aliquoted into ~1 mg units in the nitrate form, which will facilitate easier shipping and use compared to the 0.25 g parent units. The production process has been completed for the high- and medium- burnup isotopic standards C137A and C136A and will soon be performed for the weapons-grade Pu standard C138A. This report describes the measurement of trace actinide progeny of the Pu isotopes ( 234 U, 235 U, 236U, 241 Am and 237 Np) in purified C137A and 136A isotopic standards to provide informational values and assess the possibility of their use as working reference materials for radiochronometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Polarization analysis by off-axis digital holography with an improved optical system and an evaluation of its performance by simulation

An optical system of off-axis digital holography for imaging the Jones vector of an object wave is improved, and a Faraday rotator for the reference wave is also newly constructed. To evaluate the accuracy of the polarization analysis, quarter- and half-wave plates are used as the object, and the distribution of the polarization state of the transmitted light is analyzed for various orientations of the wave plates. The polarization analysis is also simulated, and the effect of a finite value of the extinction ratio and the modulation error for the reference wave is investigated numerically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗