Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Comparison of laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) at the beginning and end of the first flight season

Spectral and radiometric calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) were performed in the laboratory in June and November, 1987, at the beginning and end of the first flight season. Those calibrations are described along with changes in instrument characteristics that occurred during the flight season as a result of factors such as detachment of the optical fibers to two of the four AVIRIS spectrometers, degradation in the optical alignment of the spectrometers due to thermally-induced and mechanical warpage, and breakage of a thermal blocking filter in one of the spectrometers. These factors caused loss of signal in three spectrometers, loss of spectral resolution in two spectrometers, and added uncertainty in the radiometry of AVIRIS. Results from in-flight assessment of the laboratory calibrations are presented. A discussion is presented of improvements made to the instrument since the end of the first flight season and plans for the future. Improvements include: (1) a new thermal control system for stabilizing spectrometer temperatures, (2) kinematic mounting of the spectrometers to the instrument rack, and (3) new epoxy for attaching the optical fibers inside their mounting tubes.

Vane, Gregg↗

Measurements of the vertical profile of water vapor abundance in the Martian atmosphere from Mars Observer

An analysis is presented of the Pressure Modulator Infrared Radiometer (PMIRR) capabilities along with how the vertical profiles of water vapor will be obtained. The PMIRR will employ filter and pressure modulation radiometry using nine spectral channels, in both limb scanning and nadir sounding modes, to obtain daily, global maps of temperature, dust extinction, condensate extinction, and water vapor mixing ratio profiles as a function of pressure to half scale height or 5 km vertical resolution. Surface thermal properties will also be mapped, and the polar radiactive balance will be monitored.

Schofield, J. T.↗

Spectral and radiometric calibration of the Airborne Visible/Infrared Imaging Spectrometer

The laboratory spectral and radiometric calibration of the AVIRIS science data collected since 1987 is described. The instrumentation and procedures used in the calibration are discussed and the accuracy achieved in the laboratory as determined by measurement and calculation is compared with the requirements. Instrument performance factors affecting radiometry are described. The paper concludes with a discussion of future plans.

Vane, Gregg↗

Windshear detection and avoidance - Airborne systems perspective

The generalized windshear hazard index presently defined is derived from aircraft-position wind data and remotely sensed data obtained along the extended flight path by such candidate sensor technologies as microwave Doppler radar, Doppler lidar, and IR radiometry. Attention is given here to the results of a comparative evaluation of CO2 and Ho:YAG lidar sensor-employing windshear-detection systems, over a range 1-3 km ahead of the aircraft (corresponding to 15-45 sec of warning time). While the technology for a 10.6-micron CO2 lidar system is available, an optimum 2-micron REE laser crystal-based system remains to be developed.

Bowles, Roland L.↗

An airborne laser polarimeter system (ALPS) for terrestrial physics research

The design of a multispectral polarized laser system for characterizing the depolarization properties of the earth's surface is described. Using a laser as the light source, this airborne system measures the Stokes parameters of the surface to simultaneously arrive at the polarization degree, azimuthal angle, and ellipticity for each wavelength. The technology will be studied for the feasibility of expansion of the sensor to do surface polarization imaging. The data will be used in support of solar polarization studies and to develop laser radiometry as a tool in environmental remote sensing.

Kalshoven, James E., Jr.↗

Optical measurements of soot and temperature profiles in premixed propane-oxygen flames

Two laser diagnostic techniques were used to measure soot volume fractions, number densities and soot particle radii in premixed propane/oxygen flat flames. The two techniques used were two wavelength extinction, using 514.5 nm to 632.8 nm and 457.9 nm to 632.8 nm wavelength combinations, and extinction/scattering using 514.5 nm light. The flames were fuel-rich (equivalence ratios from 2.1 to 2.8) and had cold gas velocities varying from 3.4 to 5.5 cm/s. Measurements were made at various heights above the sintered-bronze, water-cooled flat flame burner with the equivalence ratio and cold gas velocity fixed. Also, measurements were made at a fixed height above the burner and fixed cold gas velocity while varying the equivalence ratio. Both laser techniques are based on the same underlying assumptions of particle size distribution and soot optical properties. Full Mie theory was used to determine the extinction coefficients K sub ext, and the scattering efficiencies, Q sub vv. Temperature measurements in the flames were made using infrared radiometry. Good agreement between the two techniques in terms of soot particle radii, number density and volume fraction was found for intensity ratios (I/I sub o) between 0.1 and 0.8. For intensity ratios higher or lower than this range, the differences in extinction coefficients at the wavelengths chosen for the two-wavelength method are too small to give accurate results for comparing particle radii and number densities. However, when comparing only soot volume fractions, the agreement between the two techniques continued to be good for intensity ratios up to 0.95.

Lyons, V. J.↗

Remote sensing of the earth's surface; Proceedings of the Symposium 2, Topical Meeting, and Workshop I of the 27th COSPAR Plenary Meeting, Espoo, Finland, July 18-29, 1988

The present conference discusses topics in the spaceborne study of the earth's surface, crust, and lithosphere, recent results from SPOT and Landsat TM investigations, and microwave observations of snowpack and soil properties. Attention is given to airborne and satellite-borne gravimetry, stereoviewing from space, TM studies of volcanism and tectonism in central Mexico, remote sensing of volcanoes, the uses of SPOT in forest management, the tectonics of the central Andes, and the application of VLBI to crustal movement studies. Also discussed are Landsat TM band ratios for soil investigations, snow dielectric measurements, the microwave radiometry of snow, microwave signatures of bare soil, the estimation of Alpine snow properties from Landsat TM data, and an experimental study of vegetable canopy microwave emissions.

Salomonson, V. V.↗

Observations of the 8 December 1987 occultation of AG +40 deg 0783 by 324 Bamberga

The occultation of AG+40 deg 0783 by 324 Bamberga on 8 December 1987 was observed at 13 sites in the United States, Japan, and China. At four sites the event was observed photoelectrically; the other observations were visual. A least-squares fit of a circular limb profile to the data gives a diameter of 227.6 + or - 1.9 km. However, this solution is inconsistent with a negative visual observation near the northern edge of the ground track. The inconsistency cannot be removed by assuming an elliptical profile. The data suggest that Bamberga, despite its low-amplitude lightcurve, may depart significantly from a spherical or ellipsoidal shape. The asteroid also appears to be at least 10 percent smaller than indicated by infrared radiometry.

Millis, R. L.↗

On the relationship between water vapor over the oceans and sea surface temperature

Monthly mean precipitable water data obtained from passive microwave radiometry were correlated with the National Meteorological Center (NMC) blended sea surface temperature data. It is shown that the monthly mean water vapor content of the atmosphere above the oceans can generally be prescribed from the sea surface temperature with a standard deviation of 0.36 g/sq cm. The form of the relationship between precipitable water and sea surface temperature in the range T(sub s) greater than 18 C also resembles that predicted from simple arguments based on the Clausius-Clapeyron relationship. The annual cycle of the globally integrated mass of Scanning Multichannel Microwave Radiometer (SMMR) water vapor is shown to differ from analyses of other water vapor data in both phase and amplitude and these differences point to a significant influence of the continents on water vapor. Regional scale analyses of water vapor demonstrate that monthly averaged water vapor data, when contrasted with the bulk sea surface temperature relationship developed in this study, reflect various known characteristics of the time mean large-scale circulation over the oceans. A water vapor parameter is introduced to highlight the effects of large-scale motion on atmospheric water vapor. Based on the magnitude of this parameter, it is shown that the effects of large-scale flow on precipitable water vapor are regionally dependent, but for the most part, the influence of circulation is generally less than about + or - 20 percent of the seasonal mean.

Stephens, Graeme L.↗

Structures for remotely deployable precision antennas

Future space missions such as the Earth Science Geostationary Platform (ESGP) will require highly accurate antennas with apertures that cannot be launched fully formed. The operational orbits are often inaccessible to manned flight and will involve expendable launch vehicles such as the Delta or Titan. There is therefore a need for completely deployable antenna reflectors of large size capable of efficiently handling millimeter wave electromagnetic radiation. The parameters for the type of mission are illustrated. The logarithmic plot of frequency versus aperture diameter shows the regions of interest for a large variety of space antenna applications, ranging from a 1500-meter-diameter radio telescope for low frequencies to a 20-meter-diameter infrared telescope. For the ESGP, a major application is the microwave radiometry at high frequencies for atmospheric sounding. Almost all existing large antenna reflectors for space employ a mesh-type reflecting surface. Examples are shown and discussed which deal with the various structural concepts for mesh antennas. Fortunately, those concepts are appropriate for creating the very large apertures required at the lower frequencies for good resolution. The emphasis is on the structural concepts and technologies that are appropriate to fully automated deployment of dish-type antennas with solid reflector surfaces. First the structural requirements are discussed. Existing concepts for fully deployable antennas are then described and assessed relative to the requirements. Finally, several analyses are presented that evaluate the effects of beam steering and segmented reflector design on the accuracy of the antenna.

Hedgepeth, J. M.↗

The Magellan Venus explorer's guide

The Magellan radar-mapping mission to the planet Venus is described. Scientific highlights include the history of U.S. and Soviet missions, as well as ground-based radar observations, that have provided the current knowledge about the surface of Venus. Descriptions of the major Venusian surface features include controversial theories about the origin of some of the features. The organization of the Magellan science investigators into discipline-related task groups for data-analysis purposes is presented. The design of the Magellan spacecraft and the ability of its radar sensor to conduct radar imaging, altimetry, and radiometry measurements are discussed. Other topics report on the May 1989 launch, the interplanetary cruise, the Venus orbit-insertion maneuver, and the in-orbit mapping strategy. The objectives of a possible extended mission emphasize the gravity experiment and explain why high-resolution gravity data cannot be acquired during the primary mission. A focus on the people of Magellan reveals how they fly the spacecraft and prepare for major mission events. Special items of interest associated with the Magellan mission are contained in windows interspersed throughout the text. Finally, short summaries describe the major objectives and schedules for several exciting space missions planned to take us into the 21st century.

Young, Carolynn↗

The nucleus of Comet P/Tempel 2

Simultaneous optical photometry and IR radiometry of Comet P/Tempel 2 are presented. Periodic variations of brightness are present and in phase at all wavelengths. Because the optical and thermal rotational light curves are in phase, it is concluded that the variations are caused by the changing apparent cross section of an elongated nucleus rotating with a period near 8.9 h. The variation of flux with aperture makes it possible to separate the contributions of the nucleus and the coma. The contribution by the coma is about 25 percent at maximum light in the optical and undetectable at the level of 10 percent at all times in the thermal IR.

A'Hearn, Michael F.↗

Speckle interferometry of asteroids

Steward Observatory's two-dimensional power spectrum signature analysis of speckle interferometry observations is summarized. Results for six asteroids are presented. The poles and triaxial ellipsoid dimensions of 4 Vesta, 433 Eros, 511 Davida, and 532 Herculina have been previously reported. New results for 2 Pallas and 29 Amphitrite are given, as well as further results for Vesta. Image reconstruction is ultimately required to minimize biasing effects of asteroid surface features on the simpler power spectrum analysis. Preliminary imaging results have been achieved for Vesta and Eros, and images for these two are displayed. Speckle interferometry and radiometry diameters are compared, and diameters from the two occultations of Pallas are addressed.

Drummond, Jack D.↗

Precise monitoring of global temperature trends from satellites

Passive microwave radiometry from satellites provides more precise atmospheric temperature information than that obtained from the relatively sparse distribution of thermometers over the earth's surface. Accurate global atmospheric temperature estimates are needed for detection of possible greenhouse warming, evaluation of computer models of climate change, and for understanding important factors in the climate system. Analysis of the first 10 years (1979 to 1988) of satellite measurements of lower atmospheric temperature changes reveals a monthly precision of 0.01 C, large temperature variability on time scales from weeks to several years, but no obvious trend for the 10-year period. The warmest years, in descending order, were 1987, 1988, 1983, and 1980. The years 1984, 1985, and 1986 were the coolest.

Spencer, Roy W.↗

Passive microwave retrievals of rainfall and rain system structure

Consideration is given to the development of algorithms for the Tropical Rainfall Measuring Mission to retrieve rain and rain vertical structure from passive microwave radiometry. The self-consistency approach for surface rain rate retrieval of Kummerow et al. (1989) is applied to microwave brightness temperature data from the Cooperative Huntsville Meteorological Experiment (Dodge et al., 1986). Because the algorithm simultaneously retrieves rainfall rate and rain system structure, it is suggested that the algorithm can be used to overcome the problem of the dependence of brightness temperatures on the vertical profile of hydrometeors.

Kummerow, Christian↗

On the relationship between water vapor over the oceans and sea surface temperature

Monthly mean precipitable water data obtained from passive microwave radiometry were correlated with the National Meteorological Center (NMC) blended sea surface temperature data. It is shown that the monthly mean water vapor content of the atmosphere above the oceans can generally be prescribed from the sea surface temperature with a standard deviation of 0.36 g/sq cm. The form of the relationship between precipitable water and sea surface temperature in the range T (sub s) greater than 18 C also resembles that predicted from simple arguments based on the Clausius-Clapeyron relationship. The annual cycle of the globally integrated mass of Scanning Multichannel Microwave Radiometer (SMMR) water vapor is shown to differ from analyses of other water vapor data in both phase and amplitude and these differences point to a significant influence of the continents on water vapor. Regional scale analyses of water vapor demonstrate that monthly averaged water vapor data, when contrasted with the bulk sea surface temperature relationship developed in this study, reflect various known characteristics of the time mean large-scale circulation over the oceans. A water vapor parameter is introduced to highlight the effects of large-scale motion on atmospheric water vapor. Based on the magnitude of this parameter, it is shown that the effects of large-scale flow on precipitable water vapor are regionally dependent, but for the most part, the influence of circulation is generally less than about + or - 20 percent of the seasonal mean.

Stephens, Graeme L.↗

Multiparameter radar and microwave radiative transfer modeling of nonspherical atmospheric ice particles

Multiparameter radar and polarized microwave radiative transfer models for arbitrarily shaped particles are developed. The ice crystals modeled are horizontally oriented hexagonal plates, columns, and needles. The ice water content is fixed at 0.1 g/cu m, and a realistic size distribution is used. The radar modeling is done for S through K-band, and the passive microwave calculations are at 37, 85, and 157 GHz. The modeling results show that particle shape is important for both multiparameter radar and passive microwave radiometry. Radar reflectivity and upwelling microwave brightness temperatures depend strongly on the individual particle volume, which in turn depends on the ice crystal shape. Radar differential reflectivity is high for the plates and lower for needles and columns. Linear depolarization calculations indicate that oblate ice crystals such as plates can be distinguished from prolate crystals such as columns. At 85 and 157 GHz, significant polarization brightness temperature differences are calculated for plates and columns. The particle bulk density strongly affects the radar and radiometer observables. Recent measurements of ice crystals are discussed to show that the model results have practical applicability.

Evans, K. Franklin↗

Estimated accuracy of ground-based liquid water measurements during FIRE

Since on goal of the First ISCCP Regional Experiment (FIRE) project is to improve our understanding of the relationships between cloud microphysics and cloud reflectivity, it is important that the accuracy of remote liquid measurements by microwave radiometry be thoroughly understood. The question is particularly relevant since the uncertainty in the absolute value of the radiometric liquid measurement is greatest at low liquid water contents (less than 0.1 mm). However it should be stressed that although uncertainty exists in the absolute value of liquid, it is well known that the observed radiometric signal is proportional to the amount of liquid in the antenna beam. As a result, changes in amounts of liquid are known to greater accuracy than the absolute value, which may contain a bias. Here, an assessment of the liquid measurement accuracy attained at San Nicolas Island (SNI) is presented. The vapor and liquid water data shown were computed from the radiometric brightness temperatures using statistical retrieval algorithms. The retrieval coefficients were derived from the 69 soundings made by Colorado State University during the SNI observations. Sources of error in the vapor and liquid measurements include cross-talk in the retrieval algorithms (not a factor at low liquid contents), uncertainties in the brightness temperature measurement, and uncertainties in the vapor and liquid attenuation coefficients. The relative importance of these errors is discussed. For the retrieval of path-integrated liquid water, the greatest uncertainty is caused by the temperature dependence of the absorption at microwave frequencies. As a result, the accuracy of statistical retrieval of liquid depends to large measure upon how representative the a priori radiosonde data are of the conditions prevailing during the measurements. The microwave radiometer measurements at SNI were supplemented by an infrared (IR) radiometer modified for measurement of cloud-base temperature. Thus, the IR system provides the means to incorporate continuous measurements of the liquid temperature into the retrieval process.

Snider, Jack B.↗