Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

The Sensitivity of Future Gamma-Ray Telescopes to Primordial Black Holes

The strongest existing constraints on primordial black holes with masses in the range of $m_{\rm BH} \sim 10^{15}-10^{17} \, {\rm g}$ have been derived from measurements of the local cosmic-ray electron-positron flux by Voyager 1, and MeV-scale gamma-ray observations of the Inner Galaxy by COMPTEL and INTEGRAL. In this paper, we evaluate the sensitivity of future MeV-scale gamma-ray telescopes such as e-ASTROGAM or AMEGO to Hawking radiation. We show that such an instrument would be able to provide the strongest constraints on black holes in the mass range of $m_{\rm BH} \sim (0.6-20) \times 10^{16} \, {\rm g}$, typically exceeding current constraints by approximately two orders of magnitude. In scenarios in which the observed 511 keV excess is the result of Hawking radiation, we find that e-ASTROGAM or AMEGO would not only be able to detect the Hawking radiation from the Inner Galaxy, but could precisely measure the abundance and mass distribution of the black holes responsible for this signal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of new celestial objects at far-infrared wavelengths

During a high-altitude balloon flight, sources of far-infrared radiation have been detected with apparent fluxes greater than or about equal to 3 pW/sq cm in the spectral band from 50 to 500 microns. While the sources are not uniquely identifiable with any well-known class of celestial objects, two associations should be noted. Many of the objects lie close to local stars; there is also a tendency to cluster around the ecliptic plane. Alternatively, a new class of celestial objects may have been observed.

Friedlander, M. W.↗

The application of an ultraviolet sensitive fire detector in a manned space vehicle.

Description of a detector which is sensitive to the ultraviolet molecular emissions of flames and has been selected as the basic element of the NASA Skylab fire-detection system. This detector is sensitive to approximately 10 to the minus 12th watts of ultraviolet radiation and will detect small flames at distances in excess of three meters. Its response to a variety of burning spacecraft materials has been investigated both in one-gravity and zero-gravity. The results of experiments conducted in an aircraft flying zero-gravity parabolas in an attempt to simulate the characteristics of a fire which the detector must sense are cited.

Linford, R. M. F.↗

Recent progress in the transition radiation detector techniques

A list of some of the major experimental achievements involving charged particles in the relativistic region are presented. With the emphasis mainly directed to the X-ray region, certain modes of application of the transition radiation for the identification and separation of relativistic charged particles are discussed. Some recent developments in detection techniques and improvements in detector performances are presented. Experiments were also carried out to detect the dynamic radiation, but no evidence of such an effect was observed.

Yuan, L. C. L.↗

Ultraviolet Source For Testing Hydrogen-Fire Detectors

Hand-held portable unit emits ultraviolet light similar to that emitted by hydrogen burning in air. Developed for use in testing optoelectronic hydrogen-fire detectors, which respond to ultraviolet light at wavelengths from 180 to 240 nanometers. Wavelength range unique in that within it, hydrogen fires emit small but detectable amounts of radiation, light from incandescent lamps and Sun almost completely absent, and air sufficiently transmissive to enable detection of hydrogen fire from distance. Consequently, this spectral region favorable for detecting hydrogen fires while minimizing false alarms.

Hall, Gregory A.↗

Growth and photomorphogenesis of pepper plants under red light-emitting diodes with supplemental blue or far-red lighting

Light-emitting diodes (LEDs) are a potential irradiation source for intensive plant culture systems and photobiological research. They have small size, low mass, a long functional life, and narrow spectral output. In this study, we measured the growth and dry matter partitioning of 'Hungarian Wax' pepper (Capsicum annuum L.) plants grown under red LEDs compared with similar plants grown under red LEDs with supplemental blue or far-red radiation or under broad spectrum metal halide (MH) lamps. Additionally, we describe the thermal and spectral characteristics of these sources. The LEDs used in this study had a narrow bandwidth at half peak height (25 nm) and a focused maximum spectral output at 660 nm for the red and 735 nm for the far-red. Near infrared radiation (800 to 3000 nm) was below detection and thermal infrared radiation (3000 to 50,000 nm) was lower in the LEDs compared to the MH source. Although the red to far-red ratio varied considerably, the calculated phytochrome photostationary state (phi) was only slightly different between the radiation sources. Plant biomass was reduced when peppers were grown under red LEDs in the absence of blue wavelengths compared to plants grown under supplemental blue fluorescent lamps or MH lamps. The addition of far-red radiation resulted in taller plants with greater stem mass than red LEDs alone. There were fewer leaves under red or red plus far-red radiation than with lamps producing blue wavelengths. These results indicate that red LEDs may be suitable, in proper combination with other wavelengths of light, for the culture of plants in tightly controlled environments such as space-based plant culture systems.

NASA Discipline Life Support Systems↗

Monolithic Isolated Single-Mode Ring Laser

MISER uses four-sided ring to lase nonreciprocally. Laser concept provides very-compact, efficient, and stable source of coherent radiation. Lasers of single, very-stable frequency desirable for number of purposes. Frequency stability makes possible coherent detection of laser radiation with low-bandwidth detector, useful for communications. Allows very-high-resolution spectroscopy. Any application where desired to use laser in way microwaves used traditionally enhanced if frequency very stable.

Kane, T. J.↗

Interpreting The Unresolved Intensity Of Cosmologically Redshifted Line Radiation

Intensity mapping experiments survey the spectrum of diffuse line radiation rather than detect individual objects at high signal-to-noise ratio. Spectral maps of unresolved atomic and molecular line radiation contain three-dimensional information about the density and environments of emitting gas and efficiently probe cosmological volumes out to high redshift. Intensity mapping survey volumes also contain all other sources of radiation at the frequencies of interest. Continuum foregrounds are typically approximately 10(sup 2)-10(Sup 3) times brighter than the cosmological signal. The instrumental response to bright foregrounds will produce new spectral degrees of freedom that are not known in advance, nor necessarily spectrally smooth. The intrinsic spectra of fore-grounds may also not be well known in advance. We describe a general class of quadratic estimators to analyze data from single-dish intensity mapping experiments and determine contaminated spectral modes from the data themselves. The key attribute of foregrounds is not that they are spectrally smooth, but instead that they have fewer bright spectral degrees of freedom than the cosmological signal. Spurious correlations between the signal and foregrounds produce additional bias. Compensation for signal attenuation must estimate and correct this bias. A successful intensity mapping experiment will control instrumental systematics that spread variance into new modes, and it must observe a large enough volume that contaminant modes can be determined independently from the signal on scales of interest.

INTERPRETING↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

Coaxial anode wire for gas radiation counters

The design and characteristics of a gas radiation counter are discussed. The coaxial anode consists of an elongated central wire covered with an electrically insulating sleeve. Several longitudinally discontinuous segments of an electrically conductive coating are disposed about the insulating sleeve in a coaxial pattern along the length of the central wire. The conductive coating segments form a veto or rejection anode at each end of the central wire and a main or primary charge detecting anode between the ends. The segments are coupled together so that the primary charge detecting anode is connected to detection circuitry in anti-coincidence with the veto anodes. Background radiation detected by either of the veto anodes and the primary charge detecting anode is rejected and the sensitivity of the radiation counter device is increased.

Kraushaar, W. L.↗

Cold Spray Cobalt Magnetostrictive Electromagnetic Acoustic Transducers for High Temperature Structure Monitoring

The Department of Energy’s Advanced Sensors and Instrumentation program seeks to develop and qualify advanced sensors for the nuclear industry. Reliable high temperature and high radiation sensors for detection and characterization of structural flaws in pipes, vessels, and structurally critical components is a weakness for both conventional light water reactors with coolant T-hot approaching 350oC, and for advanced reactors with T-hot temperatures in excess of 500 to 800oC. Magnetostrictive Electromagnetic Acoustic Transducers using a cold spray cobalt coating have been proposed as a sensor design that can withstand these kinds of temperatures and radiation levels to serve as online sensors to detect flaws before cracks, pits, or erosion/corrosion flaws progress to through-wall failures. This report tests cold spray cobalt as part of a magnetostrictive EMAT for high temperature service. Cobalt is known to have strong magnetostrictive properties however the effect of cold spray application is not well studied. This program was surprised to discover that cold sprayed cobalt exhibited little or no magnetostrictive behavior until it was thermally annealed. Following annealing to 650oC however, cold spray cobalt did exhibit a magnetostrictive response. Work to date prior to this milestone report publication showed that magnetostrictive EMAT was successfully tested to 400oC with an alnico permanent magnet. The program plans to extend testing with an electromagnet to higher temperatures. This follow-on work will be reported under subsequent publications or as a revision to this report.

Glass, Samuel W.↗

Pseudomaster equation for the no-count process in a continuous photodetection

The detection of cavity radiation with the detector placed outside the cavity is studied. Each leaked photon has a certain probability of propagating away without being detected. It is viewed as a continuous quantum measurement in which the density matrix is continuously revised according to the readout of the detector. The concept of pseudomaster equation for the no-count process is introduced; its solution leads to the discovery of the superoperator for the same process. It has the potential to become the key equation for continuous measurement process.

Lee, Ching-Tsung↗

New Neural Network Cloud Mask Algorithm Based on Radiative Transfer Simulations

Cloud detection and screening constitute critically important first steps required to derive many satellite data products. Traditional threshold-based cloud mask algorithms require a complicated design process and fine tuning for each sensor, and they have difficulties over areas partially covered with snow/ice. Exploiting advances in machine learning techniques and radiative transfer modeling of coupled environmental systems, we have developed a new, threshold-free cloud mask algorithm based on a neural network classifier driven by extensive radiative transfer simulations. Statistical validation results obtained by using collocated CALIOP and MODIS data show that its performance is consistent over different ecosystems and significantly better than the MODIS Cloud Mask (MOD35 C6) during the winter seasons over snow-covered areas in the mid-latitudes. Simulations using a reduced number of satellite channels also show satisfactory results, indicating its flexibility to be configured for different sensors. Comparedto threshold-based methods and previous machine-learning approaches, this new cloud mask (i) does not rely on thresholds, (ii) needs fewer satellite channels, (iii) has superior performance during winter seasons in mid-latitude areas, and (iv) can easily be applied to different sensors.

cloud mask algorithms↗

Atomistic‐Level Effects of Noncovalent Interactions and Crystalline Packing for Organic Material Structural Integrity upon Exposure to Gamma Radiation

Developing an atomistic understanding of ionizing radiation induced changes to organic materials is necessary for intentional design of greener and more sustainable materials for radiation shielding and detection. Cocrystals are promising for these purposes, but a detailed understanding of how the specific intermolecular interactions within the lattice upon exposure to radiation affect the structural stability of the organic crystalline material is unknown. This study evaluates atomistic-level effects of γ radiation on both single- and multicomponent organic crystalline materials and how specific noncovalent interactions and packing within the crystalline lattice enhance structural stability. Dose studies were performed on all crystalline systems and evaluated via experimental and computational methods. Changes in crystallinity were evaluated by p-XRD and free radical formation was analyzed via EPR spectroscopy. Type of intermolecular interactions and packing within the crystal lattice was delineated and related to the specific free radical species formed and the structural integrity of each material. Periodic DFT and HOMO-LUMO surface mapping calculations provided atomistic-level identifications of the most probable sites for the radicals formed upon exposure to γ radiation and relate intermolecular interactions and molecular packing within the crystalline lattice to experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instrumental uncertainties in radiative corrections for the MUSE experiment

The MUSE experiment at the Paul Scherrer Institute is measuring elastic lepton-proton scattering cross sections in a four-momentum transfer range from Q 2 of approximately 0.002–0.08 GeV 2 using positively and negatively charged electrons and muons. The extraction of the Born cross sections from the experimental data requires radiative corrections. Estimates of the instrumental uncertainties in those corrections have been made using the ESEPP event generator. The results depend in particular on the minimum lepton momentum that contributes to the experimental cross section and the fraction of events with hard initial-state radiation that is detected in the MUSE calorimeter and is excluded from the data. Furthermore, these results show that the angular-dependent instrumental uncertainties in radiative corrections to the electron cross section are less than 0.4% and are negligible for the muon cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Method and Apparatus for Polaradiometric Pyrometer

A radiation pyrometer for measuring the true temperature of a body is provided by detecting and measuring thermal radiation from the body based on the principle that the effects of angular emission I(sub 1) and reflection I(sub 2) on the polarization states p and s of radiation are complementary such that upon detecting the combined partial polarization state components I(sub p) = I(sub 1p) + I(sub 2p) and I(sub s) = I(sub 1s) + I(sub 2s) and adjusting the intensity of the variable radiation source of the reflected radiation I(sub 2) until the combined partial radiation components I(sub p) and I(sub s) are equal, the effects of emissivity as well as diffusivity of the surface of the body are eliminated, thus obviating the need for any post processing of brightness temperature data.

Abtahi, Ali A.↗

Polaradiometric pyrometer in which the parallel and perpendicular components of radiation reflected from an unpolarized light source are equalized with the thermal radiation emitted from a measured object to determine its true temperature

A radiation pyrometer for measuring the true temperature of a body is provided by detecting and measuring thermal radiation from the body based on the principle that the effects of angular emission I(sub 1) and reflection I(sub 2) on the polarization states p and s of radiation are complementary such that upon detecting the combined partial polarization state components I(sub p) =I(sub 1p) + I(sub 2p) and I(sub s)=I(sub 1s) + I(sub 2s) and adjusting the intensity of the variable radiation source of the reflected radiation I(sub 2) until the combined partial radiation components I(sub p) and I(sub s) are equal, the effects of emissivity as well as diffusivity of the surface of the body are eliminated, thus obviating the need for any post processing of brightness temperature data.

Abtahi, Ali A.↗

Harmonic auroral kilometric radiation of natural origin

When the ISIS 1 satellite passes through the auroral kilometric radiation (AKR) source region the sounder receiver often detects harmonic bands of radiation associated with the fundamental AKR band. These harmonic components were earlier attributed to a nonlinear instrumental response to the strong wide-band bursty AKR fundamental signal. Evidence is here presented that indicates that these harmonics are of natural origin, namely: (1) all the harmonic signals are sometimes observed to have nearly the same bandwidth, (2) when the fundamental signal has two components the harmonic signal sometimes corresponds to the weaker rather than the stronger component, (3) a weak harmonic can be observed to be associated with a weak fundamental, and (4) a 'harmonic' signal can be observed when there is no fundamental.

Benson, R. F.↗