Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROOM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Development and Testing of Functionally Operative and Visually Appealing Remote Firing Room Displays and Applications

This internship provided an opportunity for an intern to work with NASA's Ground Support Equipment (GSE) for the Spaceport Command and Control System (SCCS) at Kennedy Space Center as a remote display developer, under NASA technical mentor Kurt Leucht. The main focus was on creating remote displays and applications for the hypergolic and high pressure helium subsystem team to help control the filling of the respective tanks. As a remote display and application developer for the GSE hypergolic and high pressure helium subsystem team the intern was responsible for creating and testing graphical remote displays and applications to be used in the Launch Control Center (LCC) on the Firing Room's computers. To become more familiar with the subsystem, the individual attended multiple project meetings and acquired their specific requirements regarding what needed to be included in the software. After receiving the requirements for the displays, the next step was to create displays that had both visual appeal and logical order using the Display Editor, on the Virtual Machine (VM). In doing so, all Compact Unique Identifiers (CUI), which are associated with specific components within the subsystem, were need to be included in each respective display for the system to run properly. Then, once the display was created it was to be tested to ensure that the display runs as intended by using the Test Driver, also found on the VM. This Test Driver is a specific application that checks to make sure all the CUIs in the display are running properly and returning the correct form of information. After creating and locally testing the display it needed to go through further testing and evaluation before deemed suitable for actual use. For the remote applications the intern was responsible for creating a project that focused on channelizing each component included in each display. The core of the application code was created by setting up spreadsheets and having an auto test generator, generate the complete code structure. This application code was then loaded and ran on a testing environment set to ensure the code runs as anticipated. By the end of the semester-long experience at NASA's Kennedy Space Center, the individual should have gained great knowledge and experience in various areas of both display and application development and testing. They were able to demonstrate this new knowledge obtained by creating multiple successful remote displays that will one day be used by the hypergolic and high pressure helium subsystem team in the LCC's firing rooms to service the new Orion spacecraft. The completed display channelization application will be used to receive verification from NASA quality engineers.

Display Devices↗

Development of Space-Flight Compatible Room-Temperature Electronics for the Lynx X-Ray Microcalorimeter

We are studying the development of space-flight compatible room-temperature electronics for the Lynx x-ray microcalorimeter (LXM) of the Lynx mission. The baseline readout technique for the LXM is microwave SQUID multiplexing. The key modules at room temperature are the RF electronics module and the digital electronics and event processor (DEEP). The RF module functions as frequency converters and mainly consists of local oscillators and I/Q mixers. The DEEP performs demultiplexing and event processing, and mainly consists of field-programmable gate arrays, ADCs, and DACs. We designed the RF electronics and DEEP to be flight ready, and estimated the power, size, and mass of those modules. There are two boxes each for the RF electronics and DEEP for segmentation, and the sizes of the boxes are 13 in: × 13 in: × 9 in: for the RF electronics and 15.5 in: × 11.5 in: × 9.5 in: for the DEEP. The estimated masses are 25.1 kg∕box for the RF electronics box and 24.1 kg∕box for the DEEP box. The maximum operating power for the RF electronics is 141 W or 70.5 W∕box, and for the DEEP box is 615 W or 308 W∕box. The overall power for those modules is 756 W. We describe the detail of the designs as well as the approaches to the estimation of resources, sizes, masses, and powers.

Sakai, Kazuhiro↗

Recalibration of the NASA Exterior Effects Room

The Exterior Effects Room (EER) is a psychoacoustic testing facility at NASA Langley Research Center which primarily focuses on testing human response to aircraft noise. The 39-seat auditorium houses a real-time spatial audio system and flyover simulation environment. The audio server utilizes an implementation of three-dimensional vector base amplitude panning (VBAP), a perceptual spatial audio technique exploiting loudspeaker triplets to place a virtual sound source at an arbitrary spatial position. Due to the irregular room geometry and non-uniform loudspeaker setup, the audio server applies equalization filtering to compensate for spectral coloration attributed to loudspeaker installation, crossover filtering, and delay/gain offsets. These filters can incorporate measurements taken at multiple listening points, allowing a more extensive listening area than filters derived from measurements taken at a single listening point. This work endeavors to update the existing equalization filter generation process by producing a new set of filters for various human subject testing scenarios.

calibration↗

Recalibration of the NASA Exterior Effects Room

The Exterior Effects Room (EER) is a psychoacoustic testing facility at NASA Langley Research Center which primarily focuses on testing human response to aircraft noise. The 39-seat auditorium houses a real-time spatial audio system and flyover simulation environment. The audio server utilizes an implementation of three-dimensional vector base amplitude panning (VBAP), a perceptual spatial audio technique exploiting loudspeaker triplets to place a virtual sound source at an arbitrary spatial position. Due to the irregular room geometry and nonuniform loudspeaker setup, the audio server applies equalization filtering to compensate for spectral coloration attributed to loudspeaker installation, crossover filtering, and delay/gain offsets. These filters can incorporate measurements taken at multiple listening points, allowing a more extensive listening area than filters derived from measurements taken at a single listening point. This work endeavors to update the existing equalization filter generation process by producing a new set of filters for various human subject testing scenarios.

Signal Processing↗

The role of hydrogen in room-temperature ferromagnetism at graphite surfaces

We present a x-ray dichroism study of graphite surfaces that addresses the origin and magnitude of ferromagnetism in metal-free carbon. We find that, in addition to carbon {pi} states, also hydrogen-mediated electronic states exhibit a net spin polarization with significant magnetic remanence at room temperature. The observed magnetism is restricted to the top {approx}10 nm of the irradiated sample where the actual magnetization reaches {approx_equal} 15 emu/g at room temperature. We prove that the ferromagnetism found in metal-free untreated graphite is intrinsic and has a similar origin as the one found in proton bombarded graphite.

08 HYDROGEN↗

Fast diffusion in a room-temperature ionic liquid confined in mesoporous carbon

We report a quasielastic neutron scattering study in the temperature range of 290 to 350 K of a room temperature ionic liquid, [bmim+][Tf2N-], in the bulk form and confined in the 8.8 2.1 nm diameter pores of a mesoporous carbon matrix. In both bulk and confined liquids, our measurements, which are sensitive to the dynamics of the hydrogen-bearing cations, detect two distinct relaxation processes related to the diffusion of the cations. We have found that the cations that do not become immobilized near the pore walls exhibit an enhanced rather than suppressed diffusivity compared to the cation diffusivity in bulk liquid. Our results provide first experimental observation of molecular diffusion in a room temperature ionic liquid in confinement which is faster than diffusion in the bulk liquid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Room-temperature magnetoelectric multiferroic thin films and applications thereof

The invention provides a novel class of room-temperature, single-phase, magnetoelectric multiferroic (PbFe.sub.0.67W.sub.0.33O.sub.3).sub.x (PbZr.sub.0.53Ti.sub.0.47O.sub.3).sub.1-x (0.2.ltoreq.x.ltoreq.0.8) (PFW.sub.x-PZT.sub.1-x) thin films that exhibit high dielectric constants, high polarization, weak saturation magnetization, broad dielectric temperature peak, high-frequency dispersion, low dielectric loss and low leakage current. These properties render them to be suitable candidates for room-temperature multiferroic devices. Methods of preparation are also provided.

36 MATERIALS SCIENCE↗

Low GWP Refrigerants Modelling Study for a Room Air Conditioner Having Microchannel Heat Exchangers

Microchannel heat exchangers (MHX) have found great successes in residential and commercial air conditioning applications, being compact heat exchangers, to reduce refrigerant charge and material cost. This investigation aims to extend the application of MHXs in split, room air conditioners (RAC), per fundamental heat exchanger and system modelling. For this paper, microchannel condenser and evaporator models were developed, using a segment-to-segment modelling approach. The microchannel heat exchanger models were integrated to a system design model. The system model is able to predict the performance indices, such as cooling capacity, efficiency, sensible heat ratio, etc. Using the calibrated system and heat exchanger models, we evaluated numerous low GWP (global warming potential) refrigerants. The predicted system performance indices, e.g. cooling efficiency, compressor discharge temperature, and required compressor displacement volume etc., are compared. Suitable replacements for R22 and R-410A for the room air conditioner application are recommended.

Low GWP↗

Room temperature electrodeposition of actinides from ionic solutions

Uranic and transuranic metals and metal oxides are first dissolved in ozone compositions. The resulting solution in ozone can be further dissolved in ionic liquids to form a second solution. The metals in the second solution are then electrochemically deposited from the second solutions as room temperature ionic liquid (RTIL), tri-methyl-n-butyl ammonium n-bis(trifluoromethansulfonylimide) [Me.sub.3N.sup.nBu][TFSI] providing an alternative non-aqueous system for the extraction and reclamation of actinides from reprocessed fuel materials. Deposition of U metal is achieved using TFSI complexes of U(III) and U(IV) containing the anion common to the RTIL. TFSI complexes of uranium were produced to ensure solubility of the species in the ionic liquid. The methods provide a first measure of the thermodynamic properties of U metal deposition using Uranium complexes with different oxidation states from RTIL solution at room temperature.

36 MATERIALS SCIENCE↗

A HUMAN AUTOMATION INTERACTION CONCEPT FOR A SMALL MODULAR REACTOR CONTROL ROOM

Many advanced nuclear power plant (NPP) designs incorporate higher degrees of automation than the existing fleet of NPPs. Automation is being introduced or proposed in NPPs through a wide variety of systems and technologies, such as advanced displays, computer-based procedures, advanced alarm systems, and computerized operator support systems. Additionally, many new reactor concepts, both full scale and small modular reactors, are proposing increased automation and reduced staffing as part of their concept of operations. However, research consistently finds that there is a fundamental tradeoff between system performance with increased automation and reduced human performance. There is a need to address the question of how to achieve high performance and efficiency of high levels of automation without degrading human performance. One example of a new NPP concept that will utilize greater degrees of automation is the SMR concept from NuScale Power. The NuScale Power design requires 12 modular units to be operated in one single control room, which leads to a need for higher degrees of automation in the control room. Idaho National Laboratory (INL) researchers and NuScale Power human factors and operations staff are working on a collaborative project to address the human performance challenges of increased automation and to determine the principles that lead to optimal performance in highly automated systems. This paper will describe this concept in detail and will describe an experimental test of the concept. The benefits and challenges of the approach will be discussed.

99 GENERAL AND MISCELLANEOUS↗

TECHNICAL CONSTRAINTS TO CONDUCTING OPERATOR STUDIES IN A RECONFIGURABLE CONTROL ROOM SIMULATOR

The Human Systems Simulation Laboratory (HSSL) at Idaho National Laboratory (INL) is a full scope, full scale, and reconfigurable digital representation of an analog nuclear power plant control room. The HSSL is used to conduct human factors research studies on digital technologies being introduced into legacy nuclear power plant control rooms. With the aging nuclear fleet approaching an average of 35 years, utilities are beginning to replace their analog systems with more modern technologies, and utilizing the HSSL to accomplish these tasks. This document will describe some of the constraints identified when conducting operator studies in the HSSL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stabilized sulfur as cathodes for room temperature sodium-ion batteries.

Sodium-sulfur batteries, offering high capacity and low cost, are promising alternative to lithium-ion batteries for large-scale energy storage applications. The conventional sodium-sulfur batteries, operating at a high temperature of 300–350°C in a molten state, could lead to severe safety problems. However, the room temperature sodium-sulfur batteries using common organic liuid electrolytes still face a significant challenge due to the dissolution of intermediate sodium polysulfides. For this study, we developed room temperatue sodium-sulfur batteries using a unique porous carbon/sulfur (C/S) composite cathode, which was synthesized by infusing sulfur vapor into porous carbon sphere particles at a high temperatrure of 600°C. The porous C/S composites delivered a reversible capacity of ~860 mAh/g and retained 83% after 300 cycles. The Coulombic efficiency of as high as 97% was observed over 300 cycles. The superior electrochemical performance is attrbuted to the super sulfur stability as evidenced by its lower sensitivity to probe beam irradiation in TEM, XPS and Raman charaterization and high evaperation temperature in TGA. The results make it promising for large-scale grid energy storage and electric vehicles.

25 ENERGY STORAGE↗

Self-Assembled Layered Supercell Structure of Bi2AlMnO6 with Strong Room-Temperature Multiferroic Properties.

Room-temperature (RT) multiferroics, possessing ferroelectricity and ferromagnetism simultaneously at RT, hold great promise in miniaturized devices including sensors, actuators, transducers, and multi-state memories. In this work, we report a novel 2D layered RT multiferroic system with self-assembled layered supercell structure consisting of two mismatch-layered sub-lattices of [Bi 3 O 3+δ ] and [MO 2 ] 1.84 (M=Al/Mn, simply named as BAMO), i.e., alternative layered stacking of two mutually incommensurate sublattices made of a three-layer-thick Bi-O slab and a one-layer-thick Al/Mn-O octahedra slab along the out-of-plane direction. Strong room-temperature multiferroic responses, e.g., ferromagnetic and ferroelectric properties, have been demonstrated and attributed to the highly anisotropic 2D nature of the non-ferromagnetic and ferromagnetic sublattices which are highly mismatched. The work demonstrates an alternative design approach for new 2D layered oxide materials that hold promises as single-phase multiferroics, 2D oxides with tunable bandgaps, and beyond.

36 MATERIALS SCIENCE↗

Patient rooms transition: Contemporary makes way for the future

Recent advances in lighting research, technology and control systems are creating new opportunities to use lighting in healthcare facilities, particularly patient rooms, to improve everyday experiences for patients, visitors and staff. Healthcare facilities design has undergone shifts in thinking over the past 50 years, including the incorporation of more technology, and moving from an institutional appearance to a residential appearance, with biophilic elements. The Facilities Guidelines Institute defines the term environment of care as “those physical environment features in a health care facility that are created, structured, and maintained to support and enhance the delivery of health care”. Many attributes of the environment of care in existing hospital patient rooms, especially those built prior to 1990, reflect a focus on maximizing the efficiency of delivering medical care, sometimes without much attention to the impact of design on the experience of patients and guests.

Davis, Robert G.↗

A Guide for Selecting Appropriate Human Factors Methods and Measures in Control Room Modernization Efforts in Nuclear Power Plants

Abstract. Many of the U.S. nuclear power plants are approaching the end of their 60-year licensing period. The U.S. Department of Energy Light Water Reactor Sustainability Program is conducting targeted research to extend the lives and ensure long-term reliability, productivity, safety, and security of these plants through targeted research, such as with integrating advanced digital instrumentation and control technologies in the main control room. There are many challenges to this, one being the integration of human factors engineering in the design and evaluation of these upgrades. This paper builds upon recent efforts in developing utility-specific guidance for integrating human factors engineering in the control room modernization process by providing commonly used data collection methods that are applicable at various phases of the upgrade process. Advantages and disadvantages of each method is provided for consideration of an optimal human factors evaluation plan to be used throughout the lifespan of the upgrade process.

99 GENERAL AND MISCELLANEOUS↗

Using Qualified On-Site Nuclear Power Plant Simulators in Human Factors Validations of Control Room Upgrades

Existing commercial nuclear power plants (NPPs) are valuable assets in the infrastructure portfolio of the United States (U.S.) because they safely and reliably generate about 1/5th of all the electricity used. The instrumentation and control (I&C) systems in commercial NPPs are the ‘eyes and ears' of the operator, allowing operators to maintain situation awareness, thereby allowing the plant to operate safely and efficiently for all phases of operation. Because the I&C systems in NPPs are still mostly based on analog technologies, which are reliable but not especially cost-effective, upgrading the existing I&C in com-mercial NPPs to new digital I&C is very important. Furthermore, simulators and simulation are critical human factors engineering tools for this I&C modernization work. NPP control room simulators are essential test beds to simulate normal, abnormal, and emergency operations that allow human factors researchers to safely and realistically evaluate early design phase prototypes of the upgraded digital I&C, and validate final as-built digital I&C systems that have been modernized deployed in NPPs. This paper describes research performed using qualified on-site NPP simulators to perform human factors validations of digital I&C control room upgrades.

99 GENERAL AND MISCELLANEOUS↗

Implementation of Software Tools for Hybrid Control Rooms in the Human Systems Simulation Laboratory

The Institute for Energy Technology (IFE) and Idaho National Laboratory have designed, implemented, tested and installed a functioning prototype of a set of large screen overview and procedure support displays for the Generic Pressurized Water Reactor (GPWR) simulator in the U.S. Department of Energy’s Human Systems Simulation Laboratory. The overview display is based on IFE’s extensive experiences with large screen overview displays in the Halden Man-Machine Laboratory (HAMMLAB), and presents the main control room indicators on a combined three-screen display. The procedure support displays are designed and implemented to provide a compact but still comprehensive overview of the relevant process measurements and indicators to support operators' good situational awareness during the performance of various types of procedures and plant conditions.

97 MATHEMATICS AND COMPUTING↗

Report for Task 8.4: Development of Control Room Layout Recommendations

Idaho National Laboratory (INL) has contracted Institutt for Energiteknikk (IFE) to support in the development of an end state vision for the US Nuclear industry and in particular for a utility that is currently moving forward with a control room modernization project. This support includes the development of an Overview display and technical support in conducting an operational study. Development of operational scenarios to be conducted using a full scope simulator at the INL HSSL. Additionally IFE will use the CREATE modelling tool to provide 3-D views of the potential and possible end state view after the completion of digital upgrade project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗