Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Detectors for high energy cosmic rays on Spacelab

Two instruments designed to determine the spectra of the individual cosmic-ray components at very high energies are described. One of these (CRNE) uses a combination of gas Cerenkov counters and transition radiation detectors for the cosmic-ray nuclei lithium to nickel; the other (TRIC) is optimized for the light cosmic rays (electrons, protons, helium) and uses a transition-radiation/ionization-calorimeter combination. The CRNE instrument, constructed at the University of Chicago, was delivered to NASA for a first Shuttle flight on Spacelab-2 in summer 1985. Some of the technical and programmatic requirements encountered during the hardware construction and integration are discussed, and the expected scientific return and the prospects of using such instrumentation on the Space Station are considered.

Lheureux, J.↗

First results from Spacelab 2

Preliminary results of physical experiments carried out during the Spacelab 2 Shuttle mission are summarized. Attention is given to experiments in the fields of plasma dynamics; solar physics; high-energy astrophysics; and astronomy. Plasma experiments included an ejectable plasma diagnosics package and measurements of the passive charging of the Shuttle vehicle in the surrounding space plasma. The solar physics instrument package consisted of a solar spectral irradiance monitor; a solar optical universal polarimeter (SOUP); and a solar helium abundance high-resolution telescope and spectrograph (HRTS). Astronomical observations were performed using a scanning infrared telescope (IRT) which consisted of a highly baffled herschelian telescope and 10 detectors covering wavelengths from 2 to 120 microns. Cosmic-ray nuclei were detected and analyzed using gas Cerenkov counters and a transition radiation detector. Addition experiments included a thin film fluid dynamics payload and analysis of blood samples taken from the mission specialists. Complete data records from the experiments have now been distributed for an analysis period which will take at least a year. A table listing the Spacelab 2 experiments and their principal investigators is provided.

Urban, E. W.↗

Designs and Modeling of Architect Multi-material Scintillator System

We present a new conceptual radiation detector, the Architected Multimaterial Scintillator System, that utilizes a scintillator composed of multiple materials arranged in architected structures to enable new capabilities. By structuring differently-dyed materials, the wavelength of the scintillation light encodes additional information in radiation measurements. These structures can be realized through additive manufacture (3D-printing). Two classes of this concept are described and modelled using Monte Carlo simulations to evaluate their performance. The first detector design uses dye microstructures to encode particle tracking information, allowing for directional neutron detection and gamma/neutron discrimination. The second design uses a dye gradient to indicate the position of radiation along the gradient. The simulation results indicate this new concept in radiation detection can achieve strong performance in a variety of capabilities including particle identification, directionality and spectroscopy measurements, and particle position reconstruction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Design of an Ultra-Low Background Thermosyphon for the Majorana Demonstrator

The MAJORANA DEMONSTRATOR (MJD) is an ultra-low background neutrinoless double-beta decay (0νββ) experiment that will deploy up to 40 kg of high purity germanium detectors (HPGe). The goal of this experiment is to demonstrate the feasibility of building a detector array with less than 1 event/ton-year in a 4 keV region of interest around the 0νββ signal. HPGe diodes, when used as ionizing radiation detectors, need to be maintained at a temperature close to that of liquid nitrogen (77 K). This work describes the R&D results of a cryogenic system capable of meeting the requirements of low background and the cooling capacity required to successfully operate such a detector system. The MJD germanium detector modules will operate at liquid nitrogen temperature to provide adequate cooling for a full range of HPGe impurity concentrations. This paper shows the experimental results obtained using a two-phase horizontal thermosyphon using liquid nitrogen as the MJD’s cooling system. The cold test shows that the proposed thermosyphon has sufficient cooling power to handle the heat load of an MJD module. Results for the temperature gradient across the thermosyphon, cooling capacity, and design considerations demonstrate that the thermosyphon can effectively remove the calculated heat load of each module of the experiment. The thermosyphon will be bolted to a cold plate from which detector strings will hang. The thermal conductivity of a mockup of the MJD bolted thermal joint is experimentally determined to be below 0.1 K/W.

Detector arrays↗

Radioactive source localization in urban environments with sensor networks and the Internet of Things

The use of radiation detectors as an element in the so-called “Internet of Things” has recently become viable with the available of low-cost, mobile radiation sensors capable of streaming geo-referenced data. New methods for fusing the data from multiple sensors on such a network is presented. The traditional simple and ordinary Kriging methods present a challenge for such a network since the assumption of a constant mean is not valid in this application. In conclusion, a variety of Kalman filters are introduced in an attempt to solve the problem associated with this variable and unknown mean. Results are presented on a deployed sensor network.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Resolved Phonon Spectroscopy, Version 1.0

TRPS code was developed for the project "Time Resolved Phonon Spectroscopy". Routines contained in this piece of software were specially created to model phonon generation and tracking within materials that interact with ionizing radiation, particularly applicable to the modeling of cryogenic radiation detectors for dark matter and neutrino research. These routines were created to link seamlessly with the open source Geant4 framework for the modeling of radiation transport in matter, with the explicit intent of open sourcing them for eventual integration into that code base.

Goett, Johnny↗

Time Resolved Phonon Spectroscopy, Version 1.0

TRPS code was developed for the project "Time Resolved Phonon Spectroscopy". Routines contained in this piece of software were specially created to model phonon generation and tracking within materials that interact with ionizing radiation, particularly applicable to the modeling of cryogenic radiation detectors for dark matter and neutrino research. These routines were created to link seamlessly with the open source Geant4 framework for the modeling of radiation transport in matter, with the explicit intent of open sourcing them for eventual integration into that code base.

Goett, Johnny↗

Solid State Radiation Dosimeters for Space and Medical Applications

This report describes the development of two radiation monitors (RADMON's) for use in detecting total radiation dose and high-energy particles. These radiation detectors are chip-size devices fabricated in 1.2 micrometer CMOS and have flown in space on both experimental and commercial spacecraft. They have been used to characterize protons and electrons in the Earth's radiation belts, particles from the Sun, and protons used for medical therapy. Having proven useful in a variety of applications, the detector is now being readied for commercialization.

Buehler, Martin G.↗

Vintage electronics for trusted radiation measurements and verified dismantlement of nuclear weapons

Information barriers are trusted measurement systems to confirm the authenticity of nuclear warheads based on their radiation signatures. Traditional inspection systems rely on complex electronics both for data acquisition and processing. Several research efforts have produced prototype systems, but it has proven difficult to demonstrate that hidden switches and side channels do not exist. After almost thirty years of research and development, no viable and widely accepted system has emerged. We pursue a fundamentally different approach: Our prototype of an inspection system uses vintage hardware built around a 6502 processor. The processor uses 8-micron technology and has only about 4,200 transistors. Vintage electronics may have a number of important advantages for applications where two parties need to simultaneously establish trust in the hardware used. CPUs designed in the distant past, at a time when their use for sensitive measurements was never envisioned, drastically reduce concerns that the other party implemented backdoors or hidden switches on the hardware level. We demonstrate the performance of a prototype system using an Apple IIe and a custom-made open-source data-processing board connected to a standard sodiumiodide radiation detector for low-resolution gamma spectroscopy. Data processing and analysis is exclusively done on the Apple IIe hardware. We show that subtle differences in radiation signatures can be detected in 2–3 minutes based on the result of a simple chi-squared test. Vintage electronics may therefore offer a new path toward fieldable, trusted information barriers.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Low Profile Detector for Breast Specific Gamma Imaging

Jefferson Lab (JLab), Dilon Technologies (Dilon) and Hampton University (HU) entered into a research CRADA project titled: “Low Profile Detector for Breast Specific Gamma Imaging.” Dr. Benjamin Welch, Director of Research and Development/Engineering was the Principal Investigator for the detector project for Dilon. Dr. Nicholas Kenny was the Principal Investigator for the project for HU. The Jefferson Lab partner on this project was the Radiation Detector and Imaging Group in the Physics Division, led by Dr. Drew Weisenberger who was the coordinator of the project execution and acted as the chief contact with Dilon and HU. The responsibility of Jefferson Lab was the development and construction of detector instrumentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluorescent radiation converter

Fluorescent radiation converter used optically transparent substrate. One side of substrate is coated with plastic film containing fluorescent organic dyes that absorb optical radiation at one wavelength and emit it at longer one. Coating is formulated to respond to specific wavelengths. Emitted radiation is reflected internally inside substrate, amplifying intensity that reaches radiation detector. Converter can be made in several shapes and size; round and square bars coated all round their lengths are useful in converting relatively intense radiation and transmitting it through substrate over lengthy distances.

Viehmann, W.↗

Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy

Purpose: Plastic scintillation detectors are promising candidates for the dosimetry of low- to medium-energy photons but quantitative knowledge of their energy response is a prerequisite for their correct use. The purpose of this study was to characterize the energy dependent response of small scintillation detectors (active volume <1 mm{sup 3}) made from the commonly used plastic scintillator BC400. Methods: Different detectors made from BC400 were calibrated at a number of radiation qualities ranging from 10 to 280 kV and at a {sup 60}Co beam. All calibrations were performed at the Physikalisch-Technische Bundesanstalt, the National Metrology Institute of Germany. The energy response in terms of air kerma, dose to water, and dose to the scintillator was determined. Conversion factors from air kerma to dose to water and to dose to the scintillator were derived from Monte Carlo simulations. In order to quantitatively describe the energy dependence, a semiempirical model known as unimolecular quenching or Birks’ formula was fitted to the data and from this the response to secondary electrons generated within the scintillator material BC400 was derived. Results: The detector energy response in terms of air kerma differs for different scintillator sizes and different detector casings. It is therefore necessary to take attenuation within the scintillator and in the casing into account when deriving the response in terms of dose to water from a calibration in terms of air kerma. The measured energy response in terms of dose to water for BC400 cannot be reproduced by the ratio of mean mass energy-absorption coefficients for polyvinyl toluene to water but shows evidence of quenching. The quenching parameter kB in Birks’ formula was determined to be kB = (12.3 ± 0.9) mg MeV{sup −1} cm{sup −2}. Conclusions: The energy response was quantified relative to the response to {sup 60}Co which is the common radiation quality for the calibration of therapy dosemeters. The observed energy dependence could be well explained with the assumption of ionization quenching as described by Birks’ formula. Plastic scintillation detectors should be calibrated at the same radiation quality that they will be used at and changes of the spectrum within the application need to be considered. The authors results can be used to evaluate the range of validity of a given calibration.

60 APPLIED LIFE SCIENCES↗

SU-E-T-249: Neutron Model Upgrade for Radiotherapy Patients Monitoring Using a New Online Detector

Purpose: The purpose of this work is to improve the existing methodology to estimate neutron equivalent dose in organs during radiotherapy treatments, based on a Static Random Access Memory neutron detector (SRAMnd) [1]. This is possible thanks to the introduction of a new digital detector with improved characteristics, which is able to measure online the neutron fluence rate in the presence of an intense photon background [2]. Its reduced size, allows the direct estimation of doses in specific points inside an anthropomorphic phantom (NORMA) without using passive detectors as TLD or CR-39. This versatility will allow not only to improve the existing models (generic abdomen and H and N [1]) but to generate more specific ones for any technique. Methods: The new Thermal Neutron Rate Detector (TNRD), based on a diode device sensitized to thermal neutrons, have been inserted in 16 points of the phantom. These points are distributed to infer doses to specific organs. Simultaneous measurements of these devices and a reference one, located in front of the gantry, have been performed for the mentioned generic treatments, in order to improve the existing model. Results: These new devices have shown more precise since they agree better with Monte Carlo simulations. The comparison of the thermal neutron fluence, measured with TNRD, and the existing models, converted from events to fluence, shows an average improvement of (3.90±3.37) % for H and N and (12.61±9.43) % for abdomen, normalized to the maximum value. Conclusion: This work indicates the potential of these new devices for more precise neutron equivalent dose estimation in organs, as a consequence of radiotherapy treatments. The simplicity of the process makes possible to establish more specific models that will provide a better dose estimation. References[1] Phys Med Biol 2012; 57:6167–6191.[2] A new active thermal neutron detector. Radiat. Prot. Dosim. (in press)

60 APPLIED LIFE SCIENCES↗

RadLab: Graphical and Programming Interfaces for Interrogation of Space Telemetry Data

Sensors on multiple spacecraft in and beyond low Earth orbit continuously monitor and collect space radiation data and transmit it back to Earth. These data are of vast importance to space biology research, as ionizing radiation affects living organisms—astronauts and non-human experiment subjects alike—placing them at higher risk of carcinogenesis, degenerative diseases, and radiation sickness. Therefore, knowledge of the biological effects of space radiation is essential for planning future crewed missions beyond low Earth orbit. The RadLab project, initiated by GeneLab and ALSDA (the Open Science Data Repository; OSDR) and sponsored by the NASA Human Research Program, is a new effort aimed at connecting dosimetry data from radiation detectors located on the International Space Station (ISS), as well as other spacecraft. To date, access to these data has been fragmented across space agencies and databases; to address this issue, we have developed an application programming interface (API) and an associated graphical user interface (GUI) designed to provide a single point of access to the data. As of now, OSDR has focused on the detectors located on the ISS, with the long-term goal to establish a self-sustained portal receiving continuous updates through APIs connecting to multiple radiation databases of varying scope, as well as individual investigator contributions. The RadLab API implements a request syntax enabling users to query data by craft, sensor type, timespan, etc, allowing for arbitrary combinations of original source data, thus providing programmatic access for use in computational pipelines, while the GUI facilitates data visualization and exploration, making these data FAIR (Findable, Accessible, Interoperable, and Reusable), complementing the biological data contained in OSDR, and providing the space science community with a valuable resource for scientific analyses.

radiation↗

SiC-based neutron detector in quasi-realistic working conditions: efficiency and stability at room and high temperature under fast neutron irradiations

In the framework of the European I SMART project, we have designed and made new SiC-based nuclear radiation detectors able to operate in harsh environments and to detect both fast and thermal neutrons. In this paper, we report experimental results of fast neutron irradiation campaign at high temperature (106 deg. C) in quasi-realistic working conditions. Our device does not suffer from high temperature, and spectra do show strong stability, preserving features. These experiments, as well as others in progress, show the I SMART SiC-based device skills to operate in harsh environments, whereas other materials would strongly suffer from degradation. Work is still demanded to test our device at higher temperatures and to enhance efficiency in order to make our device fully exploitable from an industrial point of view. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Graphene oxide/carbon nanoparticle thin film based IR detector: Surface properties and device characterization

This work deals with the synthesis, characterization, and application of carbon nanoparticles (CNP) adorned graphene oxide (GO) nanocomposite materials. Here we mainly focus on an emerging topic in modern research field presenting GO-CNP nanocomposite as a infrared (IR) radiation detector device. GO-CNP thin film devices were fabricated from liquid phase at ambient condition where no modifying treatments were necessary. It works with no cooling treatment and also for stationary objects. A sharp response of human body IR radiation was detected with time constants of 3 and 36 sec and radiation responsivity was 3 mAW{sup −1}. The current also rises for quite a long time before saturation. This work discusses state-of-the-art material developing technique based on near-infrared photon absorption and their use in field deployable instrument for real-world applications. GO-CNP-based thin solid composite films also offer its potentiality to be utilized as p-type absorber material in thin film solar cell, as well.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Diamond Beam Monitor for Medical Dosimetry (Final Report)

In this technical report we will discuss the efforts to develop diamond radiation detectors as dosimeters for therapeutic proton beam diagnostics, measuring the proton fluence as well as the beam profiles in high energy proton beams. The detector performance was recorded as the ion beam induced current (IBIC) from the 800MeV proton beam using different beam conditions. The lifetime of the detectors was also measured by monitoring the real-time detector response changes during the extensive proton irradiation. All irradiated diamond detectors were then characterized using synchrotron X-rays, by measuring the detector performance including I-V curves, response maps, flux scan and timing. The device performance decay was further studied with several simulation packages (SRIM\TRIM and FLUKA), and radiation damage mechanism was investigated by using experimental data and simulation models. Several impact factors (fluence rate, total dose, contact materials and cooling time) were discussed and the radiation effect on carrier transport was studied.

36 MATERIALS SCIENCE↗

Support of research in X-ray astronomy

Activities described include: (1) the evaluation of CCD detectors for X-ray astronomy applications; (2) contributions to the development of an imaging gas scintillation proportional counter; (3) the evaluation of certain metal oxide crystals as potential radiation detectors; (4) optical observations and searches for X-ray sources discovered by the HEAO-1 A2 experiment; and (5) theoretical modeling of nonequilibrium ionization structure of supernova remnants.

Garmire, G.↗