Thermal and radiation stability of thin-film cermet resistive elements
Thin film cermet resistive elements physical controls electrical properties, physical controls, thermal and radiation stability
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Thin film cermet resistive elements physical controls electrical properties, physical controls, thermal and radiation stability
An original method is proposed to calculate the formation of specified far-field intensity distributions by a bimorph mirror in the case of initial transverse-multimode beams. The method is based on the Gerchberg-Saxton algorithm with replacement of the phase function in the plane of the control element by a function that takes into account both the intensity and phase distributions of each mode. The numerical results on the formation of a beam with the third-order super-Gaussian intensity distribution from beams composed of two or four lowest transverse modes are discussed. The experimental results on using the conventional Gerchberg-Saxton algorithm to form a desired intensity distribution from single-mode laser beams using a liquid-crystal modulator are presented. (control of laser radiation parameters)
Purpose: Report of clinical cancer control outcomes on Radiation Therapy Oncology Group (RTOG) 9406, a three-dimensional conformal radiation therapy (3D-CRT) dose escalation trial for localized adenocarcinoma of the prostate. Methods and Materials: RTOG 9406 is a Phase I/II multi-institutional dose escalation study of 3D-CRT for men with localized prostate cancer. Patients were registered on five sequential dose levels: 68.4 Gy, 73.8 Gy, 79.2 Gy, 74 Gy, and 78 Gy with 1.8 Gy/day (levels I-III) or 2.0 Gy/day (levels IV and V). Neoadjuvant hormone therapy (NHT) from 2 to 6 months was allowed. Protocol-specific, American Society for Therapeutic Radiation Oncology (ASTRO), and Phoenix biochemical failure definitions are reported. Results: Thirty-four institutions enrolled 1,084 patients and 1,051 patients are analyzable. Median follow-up for levels I, II, III, IV, and V was 11.7, 10.4, 11.8, 10.4, and 9.2 years, respectively. Thirty-six percent of patients received NHT. The 5-year overall survival was 90%, 87%, 88%, 89%, and 88% for dose levels I-V, respectively. The 5-year clinical disease-free survival (excluding protocol prostate-specific antigen definition) for levels I-V is 84%, 78%, 81%, 82%, and 82%, respectively. By ASTRO definition, the 5-year disease-free survivals were 57%, 59%, 52%, 64% and 75% (low risk); 46%, 52%, 54%, 56%, and 63% (intermediate risk); and 50%, 34%, 46%, 34%, and 61% (high risk) for levels I-V, respectively. By the Phoenix definition, the 5-year disease-free survivals were 68%, 73%, 67%, 84%, and 80% (low risk); 70%, 62%, 70%, 74%, and 69% (intermediate risk); and 42%, 62%, 68%, 54%, and 67% (high risk) for levels I-V, respectively. Conclusion: Dose-escalated 3D-CRT yields favorable outcomes for localized prostate cancer. This multi-institutional experience allows comparison to other experiences with modern radiation therapy.
A new method for frequency control of an external cavity diode laser without direct modulation of the injection current is proposed. The Pound - Drever optical heterodyne technique or the method of frequency control by frequency-modulated sidebands, in which an acousto-optic modulator operating in the Raman - Nath diffraction mode is used as an external phase modulator, can be employed to obtain error signals upon automatic frequency locking of the diode laser to the saturated absorption resonances within the D{sub 2} line of cesium atoms or to the optical cavity resonances. (control of laser radiation parameters)
The possibility of reconstructing a singular wave front of laser beams by the local tilts of the wave front measured with a Hartmann sensor is considered. The accuracy of the reconstruction algorithm described by Fried is estimated and its modification is proposed, which allows one to improve the reliability of the phase reconstruction. Based on the Fried algorithm and its modification, a combined algorithm is constructed whose advantages are demonstrated in numerical experiments. (control of laser radiation parameters)
A two-part overview of progress in space radiator technologies is presented. The first part reviews and compares the innovative heat-rejection system concepts proposed during the past decade, some of which have been developed to the breadboard demonstration stage. Included are space-constructable radiators with heat pipes, variable-surface-area radiators, rotating solid radiators, moving-belt radiators, rotating film radiators, liquid droplet radiators, Curie point radiators, and rotating bubble-membrane radiators. The second part summarizes a multielement project including focused hardware development under the Civil Space Technology Initiative (CSTI) High Capacity Power program carried out by the NASA Lewis Research Center and its contractors to develop lightweight space radiators in support of Space Exploration Initiative (SEI) power systems technology.
Radiation effects of electrons and protons on reflectance and degradation properties of specular and diffuse thermal control materials
Purpose: AAPM TG-76 report advises lung patients experiencing tumor motion >5mm to use some form of motion management with even smaller limit for complex/special procedures like SBRT. Generally, either respiratory gating or abdominal compression is used for motion management. In this retrospective study, we are using an innovative index, Volumetric Indices (VI) = (GTVnn AND GTV{sub 50+}Xmm)/(GTVnn) to quantify how much of the tumor remains within 1, 2, and 3mm margins throughout the breathing cycle using GTV{sub 50+}Xmm margin on GTV{sub 50}[nn=0,10,20,…90]. Using appropriate limits, VI can provide tumor motion information and to check if RPM gates could have been used in conjunction with abdominal compression to better manage tumor motion. Methods: 64 SBRT patients with a total of 67 lung tumors were studied. 4DCT scans were taken, fully capturing tumor motion throughout the 10 phases of the breathing cycle. For each phase, Gross Tumor Volume (GTV) was segmented and appropriates structures were defined to determine VI values. For the 2mm margin, VI values less than 0.95 for peripheral lesions and 0.97 for central lesions indicate tumor movement greater than 4mm. VI values for 1mm and 3mm margins were also analyzed signifying tumor motion of 2mm & 6mm, respectively. Results: Of the 64 patients, 35 (55%) had motion greater than 4mm & could have benefited from respiratory gating. For 5/8 (63%) middle lobe lesions, 21/27 (78%) lower lobe lesions, and 10/32 (31%) upper lobe lesions, gating could have resulted in smaller ITV. 32/55 (58%) peripheral lesions and 4/12 (33%) central lesions could have had gating. Average ITV decreased by 1.25cc (11.43%) and average VI increased by 0.11. Conclusion: Out of 64 patients, 55% exhibited motion greater than 4mm even with abdominal compression. Even with abdominalcompression, lung tumors can move >4mm as the degree of pressure which a patient can tolerate, is patient specific.
Mammography is the best tool for early detection of Breast Cancer. In this diagnostic radiology modality it is necessary to establish the criteria to ensure the proper use and operation of the equipment used to obtain mammographic images in order to contribute to the safe use of ionizing radiation. The aim of the work was to implement at FUCAM-AC the radiation protection program which must be established for patients and radiation workers according to Mexican standards [1–4]. To achieve this goal, radiation protection and quality control manuals were elaborated [5]. Furthermore, a quality control program (QCP) in the mammography systems (analog/digital), darkroom included, has been implemented. Daily sensitometry, non-variability of the image quality, visualizing artifacts, revision of the equipment mechanical stability, compression force and analysis of repetition studies are some of the QCP routine tests that must be performed by radiological technicians of this institution as a set of actions to ensure the protection of patients. Image quality and patients dose assessment were performed on 4 analog equipment installed in 2 mobile units. In relation to dose assessment, all equipment passed the acceptance criteria (<3 mGy per projection). The image quality test showed that most images (70%)– presented artifacts. A brief summary of the results of quality control tests applied to the equipment and film processor are presented. To maintain an adequate level of quality and safety at FUCAM-AC is necessary that the proposed radiation protection program in this work is applied.
We have studied the possibility of above bandgap light induced depolarization of CdZnTe planar radiation detector operating under high flux of X-rays by Pockels effect measurements. In this contribution, we show a similar influence of X-rays at 80 kVp and LED with a wavelength of 910 nm irradiating the cathode on polarization of the detector due to an accumulation of a positive space charge of trapped photo-generated holes. We have observed the depolarization of the detector under simultaneous cathode-site illumination with excitation LED at 910 nm and depolarization above bandgap LED at 640 nm caused by trapping of drifting photo-generated electrons. Although the detector current is quite high during this depolarization, we have observed that it decreases relatively fast to its initial value after switching off the depolarizing light. In order to get detailed information about physical processes present during polarization and depolarization and, moreover, about associated deep levels, we have performed the Pockels effect infrared spectral scanning measurements of the detector without illumination and under illumination in polarized and optically depolarized states.
Nature’s most powerful high-energy sources are capable of accelerating particles to high energy and radiating it away on extremely short timescales, even shorter than the light crossing time of the system. It is yet unclear what physical processes can produce such an efficient acceleration, despite the copious radiative losses. By means of radiative particle-in-cell simulations, we show that magnetically dominated turbulence in pair plasmas subject to strong synchrotron cooling generates a nonthermal particle spectrum with a hard power-law range (slope p~1) within a few eddy turnover times. Low pitch-angle particles can significantly exceed the nominal radiation-reaction limit, before abruptly cooling down. The particle spectrum becomes even harder (p<1) over time owing to particle cooling with an energy-dependent pitch-angle anisotropy. The resulting synchrotron spectrum is hard (νF ν ∝ ν s with s~1). Our findings have important implications for understanding the nonthermal emission from high-energy astrophysical sources, most notably the prompt phase of gamma-ray bursts and gamma-ray flares from the Crab nebula.
Effect of solar ultraviolet radiation on spacecraft thermal control surfaces with low absorptance/emittance ratio
Explore the source record for details and available documents.
Electron spin resonance measurements on variously treated zinc oxide powders reveal that the resonance signal at g = 1.956 is due to one electron trapped oxygen ion vacancy level, at a depth of (0.31 plus or minus 0.02) eV below the conduction band. The electrons at this level are delocalized. Schottky barrier influences nearly the entire bulk of the powder sample, and the bending of the bands caused by chemisorbed oxygen puts the vacancy level above the Fermi level almost through the entire bulk.
In this paper, we address the needs of the FIR space-flight community, providing an introductory-level treatment of the common heterodyne receiver configurations and the state of technology for various front-end components.
The paper presents the attitude reorientation taking the advantage of solar radiation pressure without use of any fuel aboard. The strategy had been adopted to make Hayabusa spacecraft keep pointed toward the Sun for several months, while spinning. The paper adds the above mentioned results reported in Sedona this February showing another challenge of combining ion engines propulsion tactically balanced with the solar radiation torque with no spin motion. The operation has been performed since this March for a half year successfully. The flight results are presented with the estimated solar array panel diffusion coefficient and the ion engine's swirl torque.
Explore the source record for details and available documents.
Explore the source record for details and available documents.