Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pressure effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thin film growth effects on electrical conductivity in entropy stabilized oxides

Entropy stabilization has garnered significant attention as a new approach to designing novel materials. Much of the work in this area has focused on bulk ceramic processing, leaving entropy-stabilized thin films relatively under-explored. Following an extensive multi-variable investigation of polycrystalline (Mg 0.2 Co 0.2 Ni 0.2 Cu 0.2 Zn 0.2 )O thin films deposited via pulsed laser deposition (PLD), it is shown here that substrate temperature and deposition pressure have strong and repeatable effects on film texture and lattice parameter. Further analysis shows that films deposited at lower temperatures and under lower oxygen chamber pressure are 40x less electrically resistive than otherwise identical films grown at higher temperature and pressure. Annealing these films in an oxygen-rich environment increases their electrical resistivity to match that of the films grown at higher temperatures and pressures. Because of this, the electric conductivity is hypothesized to be the result of polaron hopping mediated by transition metal valence changes which compensate for oxygen off-stoichiometry.

36 MATERIALS SCIENCE↗

Scale effects on core design, fuel costs, and spent fuel volume of pressurized water reactors

The desire to improve the economic competitiveness and deployment pace of nuclear energy through modularization, manufacturing, and series production had led to the development of smaller size reactors. As the standard 17x17 fuel technology is mainly maintained in the pressurized water reactors (PWRs) category, this translates into a lower number of fuel assemblies in the core and sometimes a reduced fuel height. To assess the impact of such scale change in core design on fuel cycle cost and spent fuel volume, a scoping analysis tool is developed based on infinite lattice calculations, leakage, fuel management reduced models, and levelized unit cost of electricity (LCOE) estimate. As such, cost dynamics driven by fuel specific power, burnup, core leakage, feed, cycle length, fuel assembly height as well as uranium market data are captured with consistent set of assumptions and analysis methods. A selection of 5 reactor designs representative of leading PWR developers is assessed and compared. Pursuing higher specific powers and optimal burnups are highlighted as the main fuel cost reduction drivers, nevertheless, practical limitations and opportunities must be evaluated to establish the feasibility of such enhanced fuel operation. In consequence, a detailed core design is performed using SIMULATE3 code for 5 PWR variations including natural and forced coolant circulation modes, two reactor scales, power densities of 73, 112, and 123 kW/l and higher discharge burnups. Design and optimization are performed at the lattice level, for the reflector, and at the core loading level. Satisfactory steady-state operation including power distribution, coolant operating limits, and reactivity requirements are analyzed and reported in this paper. The fuel economics of the detailed core designs confirm the scoping analysis findings. Despite the unlocked power uprates in small PWRs, the achievable burnup for a given fuel specific power requires more enrichment and shorter fuel height results in higher fabrication costs per mass of fuel, which makes scaling down core size a more expensive endeavor on the fuel cycle front. Spent fuel volumes are reported for the PWRs designed in this paper. Furthermore, these volumes are driven by the core average discharge burnup regardless of the scale in consideration. Additional cost and core performance aspects related to heavy reflector gains, fuel-reflector substitution, and disposal cost policy in the U.S. are examined.

42 ENGINEERING↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

CFD Evaluation of Pressure Change Along Coolant Passages in Sodium-Cooled Fast Reactor with Nek5000

To support the design efforts of advanced sodium-cooled fast reactors (SFRs), a series of computational fluid dynamics (CFD) simulations are performed to investigate the pressure change along various flow passages in the proposed SFR system. The simulations are carried out with the state-of-the-art spectral element flow solver, Nek5000. Two specific case studies are presented in this paper: the flow exiting the axial neutron reflector channels and the flow entering the fuel pin bundle. Due to the high Reynolds numbers expected, a Reynolds-averaged Navier-Stokes (RANS) approach is necessary to model the turbulence. A newly developed regularized k-omega RANS model is adopted in the related CFD calculations. The first case study explores the effect of Reynolds number on the pressure change when flow exits the reflector channels. The pressure change in this case has two major contributors: the change due to wall friction and the Bernoulli effect. It is noted that the nondimensional pressure loss follows a log-linear trend up to Re = 10 5 , and then the trend is flattened. In the second case study, the advanced NekNek coupling capability is tested where an integral domain can be divided into multiple subdomains with coupling interfaces, which would greatly ease the meshing process of complex engineering geometries and potentially save computational resources. The preliminary results obtained so far confirm the consistency between the NekNek results and those produced by regular Nek5000 simulation. The presented work demonstrates the readiness and flexibility of the related CFD techniques, which is part of the broader effort to leverage cutting-edge CFD to inform the advanced nuclear reactor designs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pressure–strain interaction. III. Particle-in-cell simulations of magnetic reconnection

How energy is converted into thermal energy in weakly collisional and collisionless plasma processes, such as magnetic reconnection and plasma turbulence, has recently been the subject of intense scrutiny. The pressure–strain interaction has emerged as an important piece, as it describes the rate of conversion between bulk flow and thermal energy density. In two companion studies, we presented an alternate decomposition of the pressure–strain interaction to isolate the effects of converging/diverging flow and flow shear instead of compressible and incompressible flow, and we derived the pressure–strain interaction in magnetic field-aligned coordinates. Here, we use these results to study pressure–strain interaction during two-dimensional anti-parallel magnetic reconnection. We perform particle-in-cell simulations and plot the decompositions in both Cartesian and magnetic field-aligned coordinates. We identify the mechanisms contributing to positive and negative pressure–strain interaction during reconnection. Furthermore, this study provides a roadmap for interpreting numerical and observational data of the pressure–strain interaction, which should be important for studies of reconnection, turbulence, and collisionless shocks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oxygen Limit for Flammability of a Gas Mixture of Helium – Hydrogen – Oxygen in the U.S. Department of Energy Standard Canister

The radiolytic breakdown of residual free, physisorbed, and chemisorbed waters is anticipated in the sealed dry storage of spent nuclear fuel (SNF), releasing H 2 gas into the initial cover gas of helium. For aluminum-clad SNF (ASNF) in particular, the expected total hydrogen in the canister is enough to dominate the cover gas mixture if fully released, and based on experimental rates of H 2 generation, H 2 percentages exceeding the lower flammability limit appear likely. However, no evidence of radiolytic generation of O 2 has been observed to date, so the potential for flammability is averted due to the lack O 2 . Lack of oxygen has been credited for avoiding flammability in some existing storage and transportation approaches for SNF and other waste. This report reviews literature on flammability limits with a focus on the limiting oxygen concentration to provide technical underpinnings to refine a flammability criterion for gas mixtures of helium, hydrogen, and oxygen where the oxygen is expected to be the limiting species. While there is general consensus on H 2 flammability limits at standard temperature and pressure, the decay heat and gas generation within ASNF sealed dry storage canisters could push them to elevated temperatures and pressures, so the goal is to identify an oxygen threshold that will bound the behavior over the temperature and pressure range of the U.S. Department of Energy (DOE) Standard Canister. The information reviewed in this document supports the criterion that the oxygen concentration in a He-H 2 -O 2 mixture should be less than 1.5% to avoid flammability at temperatures and pressures relevant to sealed dry storage of ASNF in the DOE Standard Canister, i.e., up to 343°C (650°F) and 500 psig, respectively. Note that while data covering the full range of temperature at atmospheric pressure and nearly the full range of pressure at room temperature were available, data for the combined effects was available only at moderate temperatures and pressures; the recommended 1.5% O 2 threshold is based on the breadth of available data reported here and apparent trends therein.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal conductivity tensor of β -1,3,5,7-tetranitro-1,3,5,7-tetrazoctane ( β -HMX) as a function of pressure and temperature

Here, we have used reverse non-equilibrium molecular dynamics (RNEMD) simulations to determine the full thermal conductivity tensor for the monoclinic high explosive crystal β-1,3,5,7-tetranitro-1,3,5,7-tetrazoctane (β-HMX). In order to do so for the monoclinic crystal, four directions for heat propagation are used. Effects of the temperature and pressure are investigated between 200 and 500 K and 0 and 5 GPa, respectively, which approximately covers the range where the β polymorph is stable. Simulations are carried out with the Smith–Bharadwaj non-reactive empirical potential [Smith and Bharadwaj, J. Phys. Chem. B 103, 3570 (1999)], which is known to reproduce well the thermo-elastic properties of HMX. Our results indicate that the thermal conductivity, κ, is highly anisotropic, with 36% difference between the two extreme values at 300 K and 0 GPa. A simple function is used to interpolate κ in the pressure-temperature regime considered in this study, which can be used in continuum models. The results from RNEMD simulations compare well with available experimental results from the literature and allow the determination of κ for any direction and temperature and pressure within or around the fitting interval.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Topological features in the ferromagnetic Weyl semimetal CeAlSi: Role of domain walls

In the ferromagnetic (FM) Weyl semimetal CeAlSi both space-inversion and time-reversal symmetries are broken. Our quantum oscillation (QO) data indicate that the FM ordering modifies the Fermi-surface topology and also leads to an unusual drop in the QO amplitude. In the FM phase, we find a pressure-induced suppression of the anomalous and the loop Hall effects. This cannot be explained based on the electronic band structure or magnetic structure, both of which are nearly pressure independent. Instead, we show that a simplified model describing the scattering of Weyl fermions off FM domain walls can potentially explain the observed topological features. Our study highlights the importance of domain walls for understanding transport in FM Weyl semimetals.

36 MATERIALS SCIENCE↗

Predictive Large-Eddy Simulation of Supercritical-Pressure Reactive Flows in the Cold Ignition Regime

This report describes a one-year study performed under DOE sponsorship, continuing the investigation of high-pressure turbulent reactive flows. The interest is in the effect of the chemical species distribution in high-pressure turbulent flows in the presence of strong temperature gradients as would occur during reactions in realistic flows. The prime example of such flows are boundary layers in which the wall is at a lower temperature than that of the fluid, as would be the case in Diesel engines. Previous DOE BES work in the program further highlighted the importance of the boundary layer as a configuration for fundamental studies: soot formation in boundary layers is still a problem poorly understood and depends on the availability of particular chemical species at that location, and when boundary layer Large Eddy Simulations results were compared with measurements, the agreement was unfavorable, showing that this important ‘unit’ problem is not well understood. To understand this unit problem, modeling and Direct Numerical Simulations of this unit problem were conducted for the simplest possible multispecies system, that is a binary-species system. The results discovered a new phenomenon, that is, Soret effect induced uphill diffusion. The far-reaching implication is that through an imposed wall/fluid temperature difference it is possible to control the distribution of the species in the boundary layer. Because the results have been documented in one paper published in the refereed literature, and also in conference papers, this final report is in the form of an Executive Summary succinctly describing the results and putting them in perspective with respect to existing information. The refereed and conference papers published are individually listed as Appendices and attached to this report. One manuscript is still in progress and is thus not listed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Structure-Spin-Transport Anomaly in Quasi-One-Dimensional Ba9Fe3Te15 under High Pressure

Recently, a series of novel compounds Ba3MX5 (M= Fe, Ti, V; X=Se, Te) with hexagonal crystal structures composed of quasi-1-dimensional (1D) magnetic chains has been synthesized by our research team using high-pressure and high-temperature methods. The initial hexagonal phases persist to the maximum achievable pressure, while spin configurations and magnetic interactions may change dramatically as a result of considerable reductions in interchain separations upon pressurization. These compounds therefore offer unique possibilities for studying the evolution of intrinsic electronic structures in quasi-1D magnetic systems. Here we present a systematic investigation of Ba9Fe3Te15, in which the interchain separations between trimerized 1D chains (~10.2 Å) can be effectively modulated by external high pressure. The crystal structure especially along the 1D chains exhibits an abnormal expansion at ~5GPa, which accompanies trimerization entangled anomalous mixed-high-low spin transition. An insulator-metal transition has been observed under high pressure as a result of charge-transfer gap closing. Pressure-induced superconductivity emerges at 26GPa, where the charge-transfer gap fully closes, 3D electronic configuration forms and local spin fully collapses.

Zhang, Jun↗

Counterintuitive Trend of Intrusion Pressure with Temperature in the Hydrophobic Cu 2 (tebpz) MOF

Liquid porosimetry experiments reveal a peculiar trend of the intrusion pressure of water in hydrophobic Cu 2 (3,3',5,5'-tetraethyl-4,4'-bipyrazolate) MOF. At lower temperature (T) range, the intrusion pressure (P i ) increases with T. For higher T values, P i first reaches a maximum and then decreases. This is at odds with the Young–Laplace law, which for systems showing a continuous decrease of contact angle with T predicts a corresponding reduction of the intrusion pressure. Though the Young–Laplace law is not expected to provide quantitative predictions at the subnanoscale of Cu 2 (tebpz) pores, the physical intuition suggests that to a reduction of their hydrophobicity corresponds a reduction of the P i . Molecular dynamics simulations and sychrothron experiments allowed to clarify the mechanism of the peculiar trend of P i with T. At increasing temperatures the vapor density within the MOF’ pores grows significantly, bringing the corresponding partial pressure to ≈5 MPa. This pressure, which is consistent with the shift of P i observed in liquid porosimetry, represents a threshold to be overcame before intrusion takes place. Beyond some value of temperature, the phenomenon of reduction of hydrophobicity (and water surface tension) dominated over the opposite effect of increase of vapor pressure and P i inverts its trend with T.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas Bubble Evolution in Polycrystalline UMo Fuels Under Elastic-Plastic Deformation: A Phase-Field Model With Crystal-Plasticity

In monolithic UMo fuels, the interaction between the Al cladding and large gas bubble volumetric swelling causes both elastic-plastic and creep deformation. In this work, a phase-field model of gas bubble evolution in polycrystalline UMo under elastic-plastic deformation was developed for studying the dynamic interaction between evolving gas bubble/voids and deformation. A crystal plasticity model, which assumes that the plastic strain rate is proportional to resolved shear stresses of dislocation slip systems on their slip planes, was used to describe plastic deformation in polycrystalline UMo. Xe diffusion and gas bubble evolution are driven by the minimization of chemical and deformation energies in the phase-field model, while evolving gas bubble structure was used to update the mechanical properties in the crystal plasticity model. With the developed model, we simulated the effect of gas bubble structures (different volume fractions and internal gas pressures) on stress-strain curves and the effect of local stresses on gas bubble evolution. The results show that 1) the effective Young’s modulus and yield stress decrease with the increase of gas bubble volume fraction; 2) the hardening coefficient increases with the increase of gas bubble volume fraction, especially for gas bubbles with higher internal pressure; and 3) the pressure dependence of Xe thermodynamic and kinetic properties in addition to the local stress state determine gas bubble growth or shrinkage. The simulated results can serve as a guide to improve material property models for macroscale fuel performance modeling.

36 MATERIALS SCIENCE↗

In situ friction and wear behavior of rubber materials incorporating various fillers and/or a plasticizer in high-pressure hydrogen

Polymers are used routinely for equipment and infrastructure in hydrogen vehicle refueling stations, but significant gaps remain in understanding their hydrogen compatibility. The tribological properties of these materials in a high-pressure hydrogen environment is important in preventing component failure and the need for frequent replacement. We present in situ tribological studies on model rubbers, which include common fillers and plasticizer, using an in situ tribometer developed previously. Results suggest a clear, yet complicated, combined effect of the high-pressure hydrogen and the additives on the tribological performance of the chosen materials, as compared to matching experiments performed in ambient air. We find that the additives improved wear resistance in EPDM but deteriorated that in NBR due to disparate additive-polymer interactions.

Kuang, Wenbin↗