Microstructures and mechanical properties of electron beam-rapid manufactured Ti-6Al-4V biomedical prototypes compared to wrought Ti-6Al-4V

This study represents an exploratory characterization and comparison of electron-beam melted (EBM) or rapid manufacturing (RM) of Ti-6Al-4V components (from nominal 30 {mu}m diameter powder) with wrought products. Acicular {alpha} and associated {beta} microstructures observed by optical metallography and electron microscopy (SEM and TEM) are compared along with corresponding tensile test and hardness data; including the initial powder particles where the Vickers microindentation hardness averaged 5.0 GPa in comparison with the fully dense, EB manufactured product with an average microindentation hardness ranging from 3.6 to 3.9 GPa. This compared with wrought products where the Vickers microindentation hardness averaged 4.0 GPa. Values of UTS for the EBM samples averaged 1.18 GPa for elongations ranging from 16 to 25%. Biomaterials/biomedical applications of EBM prototypes in direct prosthesis or implant manufacturing from CT or MRI data are discussed in the context of this work, especially prospects for tailoring physical properties through EB control to achieve customized and optimized implant and prosthetic products direct from CT-scans.

36 MATERIALS SCIENCE↗

Signaling snapshots of a serotonin receptor activated by the prototypical psychedelic LSD

Serotonin (5-hydroxytryptamine [5-HT]) 5-HT2-family receptors represent essential targets for lysergic acid diethylamide (LSD) and all other psychedelic drugs. Although the primary psychedelic drug effects are mediated by the 5-HT 2A serotonin receptor (HTR2A), the 5-HT 2B serotonin receptor (HTR2B) has been used as a model receptor to study the activation mechanisms of psychedelic drugs due to its high expression and similarity to HTR2A. Here, in this study, we determined the cryo-EM structures of LSD-bound HTR2B in the transducer-free, Gq-protein-coupled, and β-arrestin-1-coupled states. These structures provide distinct signaling snapshots of LSD’s action, ranging from the transducer-free, partially active state to the transducer-coupled, fully active states. Insights from this study will both provide comprehensive molecular insights into the signaling mechanisms of the prototypical psychedelic LSD and accelerate the discovery of novel psychedelic drugs.

60 APPLIED LIFE SCIENCES↗

Performance of the prototype module of the GlueX electromagnetic barrel calorimeter

A photon beam test of the 4 m long prototype lead/scintillating-fibre module for the GlueX electromagnetic barrel calorimeter was carried out in Hall B at the Thomas Jefferson National Accelerator Facility with the objective of measuring the energy and timing resolutions of the module as well as the number of photoelectrons generated. Data were collected over an energy range of 150 - â 650 MeV at multiple positions and angles along the module. Details of the analysis at the centre of and perpendicular to the module are shown herein; the results are View the MathML source, View the MathML source ps, and 660 photoelectrons for 1 GeV at each end of the module.

Leverington, Blake↗

Beam Test of a Time-of-Flight Detector Prototype

We report on results of a Time-of-Flight, TOF, counter prototype in beam tests at SLAC and Fermilab. Using two identical 64-pixel Photonis Microchannel Plate Photomultipliers, MCP-PMTs, to provide start and stop signals, each having a 1 cm-long quartz Cherenkov radiator, we have achieved a timing resolution of {sigma}{sub Single{_}detector} {approx} 14 ps.

43 PARTICLE ACCELERATORS↗

Performance of Prototypes for the ALICE Electromagnetic Calorimeter

The performance of prototypes for the ALICE electromagnetic sampling calorimeter has been studied in test beam measurements at FNAL and CERN. A 4 x 4 array of final design modules showed an energy resolution of about 11%/{radical}E(GeV) {circle_plus} 1.7% with a uniformity of the response to electrons of 1% and a good linearity in the energy range from 10 to 100 GeV. The electromagnetic shower position resolution was found to be described by 1.5 mm {circle_plus} 5.3 mm/{radical}E(GeV). For an electron identification efficiency of 90% a hadron rejection factor of >600 was obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A prototype station for ARIANNA: a detector for cosmic neutrinos

The Antarctic Ross Iceshelf Antenna Neutrino Array (ARIANNA) is a proposed detector for ultra-high energy astrophysical neutrinos. It will detect coherent radio Cherenkov emission from the particle showers produced by neutrinos with energies above about 1017 eV. ARIANNA will be built on the Ross Ice Shelf just off the coast of Antarctica, where it will eventually cover about 900 km2 in surface area. There, the ice-water interface below the shelf reflects radio waves, giving ARIANNA sensitivity to downward going neutrinos and improving its sensitivity to horizontally incident neutrinos. ARIANNA detector stations will each contain 4-8 antennas which search for brief pulses of 50 MHz to 1 GHz radio emission from neutrino interactions. We describe a prototype station for ARIANNA which was deployed in Moore's Bay on the Ross Ice Shelf in December 2009, discuss the design and deployment, and present some initial figures on performance. The ice shelf thickness was measured to be 572 +- 6 m at the deployment site.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy and time resolution of a LYSO matrix prototype for the Mu2e experiment

We have measured the performances of a LYSO crystal matrix prototype tested with electron and photon beams in the energy range 60–450 MeV. Furthermore, this study has been carried out to determine the achievable energy and time resolutions for the calorimeter of the Mu2e experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of low-cost, large-area prototype Si(Li) detectors for the GAPS experiment

A Si(Li) detector fabrication procedure has been developed with the aim of satisfying the unique requirements of the GAPS (General Antiparticle Spectrometer) experiment. Si(Li) detectors are particularly well-suited to the GAPS detection scheme, in which several planes of detectors act as the target to slow and capture an incoming antiparticle into an exotic atom, as well as the spectrometer and tracker to measure the resulting decay X-rays and annihilation products. These detectors must provide the absorption depth, energy resolution, tracking efficiency, and active area necessary for this technique, all within the significant temperature, power, and cost constraints of an Antarctic long-duration balloon flight. We report here on the fabrication and performance of prototype 2"-diameter, 1–1.25 mm-thick, single-strip Si(Li) detectors that provide the necessary X-ray energy resolution of ~4 keV for a cost per unit area that is far below that of previously-acquired commercial detectors. Lastly, this fabrication procedure is currently being optimized for the 4"-diameter, 2.5 mm-thick, multi-strip geometry that will be used for the GAPS flight detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RD53A: A large-scale prototype chip for the phase II upgrade in the serially powered HL-LHC pixel detectors

The phase II upgrade of the HL-LHC experiments within the LHC intends to deepen the studies of the Higgs boson and to allow the discovery of further particles by adding an integrated luminosity of about 4000 fb -1 over 10 years of operation. This upgrade would overwhelm the installed pixel detector readout chips with higher hit rates and radiation levels than ever before. To match these extreme requirements the RD53 collaboration, a joint effort between ATLAS and CMS, developed RD53A, a new generation pixel detector readout chip prototype manufactured in a 65 nm CMOS technology. It is half the size of the final pixel chips and designed to meet requirements in the face of 3 GHz/cm 2 hit rate after irradiation to 500 Mrad. The detector is able to use 50×50 μm 2 or 25×100 μm 2 pixels with high readout speed of up to 4 links per chip with 1.28 Gbit/s each. Shunt–LDO regulators integrated on the bottom of the chip provide the required voltages to the two power domains, analog and digital. These regulators enable serial powering of the pixel modules, which is the only feasible, radiation hard scheme to ensure acceptable power cable losses and to stay within the material budget for the future pixel detectors. Finally, an overview of the status and challenges of serial powering and the Shunt–LDO regulator development will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A prototype system for dynamically polarized neutron protein crystallography

The sensitivity of Neutron Macromolecular Crystallography to the presence of hydrogen makes it a powerful tool to complement X-ray crystallographic studies using protein crystals. The power of this technique is currently limited by the relative low neutron flux provided by even the most powerful neutron sources. The strong polarization dependence of the neutron scattering cross section of hydrogen will allow us to use Dynamic Nuclear Polarization to dramatically improve the signal to noise ratio of neutron diffraction data, delivering order of magnitude gains in performance, and enabling measurements of radically smaller crystals of larger protein systems than are possible today. Here, we present a prototype frozen spin system, built at Oak Ridge National Laboratory to polarize single protein crystals on the IMAGINE beamline at the High Flux Isotope Reactor (HFIR). Details of the design and construction will be described, as will the performance of the system offline and during preliminary tests at HFIR.

47 OTHER INSTRUMENTATION↗

Advancement of LANSCE accelerator facility as a 1-MW Fusion Prototypic Neutron Source

The Fusion Prototypic Neutron Source (FPNS) is considered to be a testbed for scientific understanding of material degradation in future nuclear fusion reactors (Zinkle and Moeslang, 2013; Summary Report on the FPNS Workshop, 2018; Pitcher et al., 2019). The primary mission of FPNS is to provide a damage rate in iron samples of 8-11 dpa/calendar year with He/dpa ratio of 10 appm in irradiation volume of 50 cm 3 or larger with irradiation temperature 300–1000 °C and flux gradient less than 20%/cm in the plane of the sample. The Los Alamos Neutron Science Center (LANSCE) is an attractive candidate for the FPNS project. The Accelerator Facility was designed and operated for an extended period as a 0.8-MW Meson Factory. The existing setup of the LANSCE accelerator complex can nearly fulfill requirements of the fusion neutron source station. The primary function of the upgraded accelerator systems is the safe and reliable delivery of a 1.25-mA continuous proton beam current at 800-MeV beam energy from the switchyard to the target assembly to create 1 MW power of proton beam interacting with a solid tungsten target. The present study describes existing accelerator setup and further development required to meet the needs of FPNS project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Layout and performance of HPK prototype LGAD sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology, will cover the pseudo-rapidity region of 2.4 < |n| < 4.0 with two end caps on each side and a total area of 6.4 m 2 . The timing performance can be improved by implanting an internal gain layer that can produce signals with a fast rising edge. It significantly improves the signal-to-noise ratio. The required average timing resolution per track for a minimum ionizing particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1MeV neutron-equivalent fluence up to 2.5 10 15 n eq /cm 2 including a safety factor of 1.5 before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-ups at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

47 OTHER INSTRUMENTATION↗

Radiation campaign of HPK prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)

In this work, we report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of were irradiated in steps of roughly 2 up to a fluence of 3. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at °C.

47 OTHER INSTRUMENTATION↗

Strip sensor performance in prototype modules built for ATLAS ITk

ATLAS experiment is preparing an upgrade of its detector for High-Luminosity LHC (HL-LHC) operation. The upgrade involves installation of the new all-silicon Inner Tracker (ITk). In the context of the ITk preparations, more than 80 strip modules were built with prototype barrel sensors. They were tested with electrical readout on a per-channel basis. In general, an excellent performance was observed, consistent with previous ASIC-level and sensor-level tests. However, the lessons learned included two phenomena important for the future phases of the project. First was the need to store and test the modules in a dry environment due to humidity sensitivity of the sensors. The second was an observation of high noise regions for 2 modules. The high noise regions were tested further in several ways, including monitoring the performance as a function of time and bias voltage. Additionally, direct sensor-level tests were performed on the affected channels. The inter-strip resistance and bias resistance tests showed low values, indicating a temporary loss of the inter-strip isolation. A subsequent recovery of the noise performance was observed. Here we present the test details, an analysis of how the inter-strip isolation affects the module noise, and the relationship with sensor-level quality control tests.

47 OTHER INSTRUMENTATION↗

A novel active veto prototype detector with an inner target for improved rare event searches

Here, we report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A germanium veto detector of mass ~500g with an outer diameter of 76 mm and an inner diameter of 28 mm was produced inside of which was mounted a 25 mm diameter germanium inner target detector of mass ~10g. The detector was designed using inputs from a GEANT4 based simulation, where it was modeled to be sandwiched between two germanium detectors. The simulation showed that the background rates (dominated by gamma interactions) could be reduced by >90%, and that such an arrangement is sufficient for aggressive background reduction needed for neutrino and dark matter search experiments. Operating at mK temperatures at the experimental site, the veto detector prototype achieved a baseline resolution of 1.24±0.02 keV while hosting a functional inner target detector. The baseline resolution of the inner target detector was 147±2 eV. The experimental results of an identical detector arrangement are in excellent agreement with the simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron resonance transmission analysis prototype system for thorium fuel cycle safeguards

Emerging thorium-based reactor designs and fuel cycles present challenges to traditional non-destructive assay techniques used in international safeguards. Specifically, assaying the masses of 233 U and 235 U when they are present together in samples with high gamma ray backgrounds is difficult because of similar passive neutron signatures and relatively weak gamma-ray emissions of 233 U. The Pacific Northwest National Laboratory (PNNL) and the Massachusetts Institute of Technology (MIT) are developing a compact neutron resonance transmission analysis (NRTA) system as one potential solution to these challenges. The NRTA technique provides isotopic information for a sample via neutron time-of-flight (TOF) measurements that exploit a sample’s epithermal neutron resonance cross-sections. A recently developed portable NRTA system uses a commercially available, pulsed deuterium-tritium neutron generator with a ~2 m flight path and a GS20 lithium glass scintillator detector. Finally, this paper describes the prototype NRTA system design, a refined radiation transport model of the system, preliminary measurements with thorium and uranium sources, and demonstration of a quantitative isotopic estimation algorithm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation and measurement of the dynamic strain response in a prototypical spallation target

The Second Target Station (STS) at the Spallation Neutron Source (SNS) will address emerging scientific challenges by providing a source of intense cold neutrons to instruments optimized for this source. The STS target will use rotating tungsten blocks and will receive 1.3 GeV proton beam pulses from the SNS accelerator at a repetition rate of 15 Hz. The facility life is planned for 40 years, and each target assembly life is expected to be approximately 10 years. An accurate strain prediction is then critical for fatigue life assessment of STS target blocks because they will be subject to approximately 10 8 beam pulses per lifetime. As an R&D activity, the Los Alamos Neutron Science Center (LANSCE) Weapons Neutron Research (WNR) Target 2 (Blue Room) facility was used to test the strain response of prototypical target blocks to the thermal shock of a proton pulse. The blue room was well suited for a pulsed proton beam impact test of subscale STS target blocks; the 800 MeV proton energy is approximately 60 % of the 1.3 GeV proton energy expected from the SNS accelerator to the STS. The LANSCE Proton Storage Ring (PSR) and SNS are both short-pulse proton beam sources with nominal pulse widths of 250 ns and 661 ns, respectively, so the energy deposition in the target occurs in <1 μs pulse duration. Strain measurements on the outer surface of three target blocks (bare tungsten, tantalum-clad tungsten, niobium-clad tungsten) were recorded for comparison against neutronics and structural simulations. In conclusion, this experiment and the supporting simulations satisfied the following primary research goals for the STS target.

Dynamic strain response↗

Residues R{sup 199}H{sup 200} of prototype foamy virus transactivator Bel1 contribute to its binding with LTR and IP promoters but not its nuclear localization

Prototype foamy virus encodes a transactivator called Bel1 that enhances viral gene transcription and is essential for PFV replication. Nuclear localization of Bel1 has been reported to rely on two proximal basic motifs R{sup 199}H{sup 200} and R{sup 221}R{sup 222}R{sup 223} that likely function together as a bipartite nuclear localization signal. In this study, we report that mutating R{sup 221}R{sup 222}R{sup 223}, but not R{sup 199}H{sup 200}, relocates Bel1 from the nucleus to the cytoplasm, suggesting an essential role for R{sup 221}R{sup 222}R{sup 223} in the nuclear localization of Bel1. Although not affecting the nuclear localization of Bel1, mutating R{sup 199}H{sup 200} disables Bel1 from transactivating PFV promoters. Results of EMSA reveal that the R{sup 199}H{sup 200} residues are vital for the binding of Bel1 to viral promoter DNA. Moreover, mutating R{sup 199}H{sup 200} in Bel1 impairs PFV replication to a much greater extent than mutating R{sup 221}R{sup 222}R{sup 223}. Collectively, our findings suggest that R{sup 199}H{sup 200} directly participate in Bel1 binding to viral promoter DNA and are indispensible for Bel1 transactivation activity. - Highlights: • The R{sup 221}R{sup 222}R{sup 223} residues are essential for the nuclear localization of Bel1. • Although not affecting the nuclear localization of Bel1, mutating R{sup 199}H{sup 200} disables Bel1 from transactivating PFV promoters. • The R{sup 199}H{sup 200} residues directly participate in Bel1 binding to viral promoter DNA. • Mutating R{sup 199}H{sup 200} in Bel1 impairs PFV replication to a much greater extent than mutating R{sup 221}R{sup 222}R{sup 223}.

60 APPLIED LIFE SCIENCES↗