Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Revised calibration of the Sm:SrB{sub 4}O{sub 7} pressure sensor using the Sm-doped yttrium-aluminum garnet primary pressure scale

The pressure-induced shift of Sm:SrB{sub 4}O{sub 7} fluorescence was calibrated in a quasi-hydrostatic helium medium up to 60 GPa using the recent Sm-doped yttrium-aluminum garnet primary pressure scale as a reference. The resulting calibration can be written as P = −2836/14.3 [(1 + Δλ/685.51){sup −14.3 }− 1]. Previous calibrations based on the internally inconsistent primary scales are revised, and, after appropriate correction, found to agree with the proposed one. The calibration extended to 120 GPa was also performed using corrected previous data and can be written as P = 4.20 Δλ (1 + 0.020 Δλ)/(1 + 0.036 Δλ)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diamond synthesis at atmospheric pressure by microwave capillary plasma chemical vapor deposition

Polycrystalline diamond has been synthesized on silicon substrates at atmospheric pressure, using a microwave capillary plasma chemical vapor deposition technique. The CH{sub 4}/Ar plasma was generated inside of quartz capillary tubes using 2.45 GHz microwave excitation without adding H{sub 2} into the deposition gas chemistry. Electronically excited species of CN, C{sub 2}, Ar, N{sub 2}, CH, H{sub β}, and H{sub α} were observed in the emission spectra. Raman measurements of deposited material indicate the formation of well-crystallized diamond, as evidenced by the sharp T{sub 2g} phonon at 1333 cm{sup −1} peak relative to the Raman features of graphitic carbon. Field emission scanning electron microscopy images reveal that, depending on the growth conditions, the carbon microstructures of grown films exhibit “coral” and “cauliflower-like” morphologies or well-facetted diamond crystals with grain sizes ranging from 100 nm to 10 μm.

36 MATERIALS SCIENCE↗

Stable high-pressure phases in the H-S system determined by chemically reacting hydrogen and sulfur

Synchrotron x-ray diffraction and Raman spectroscopy have been used to study the chemical reactions of molecular hydrogen (H 2 ) with sulfur (S) at high pressures. We find theoretically predicted Cccm and Im3¯m H 3 S to be the reaction products at 50 and 140 GPa, respectively. Im3¯m H 3 S is a stable crystalline phase above 140 GPa and it transforms to R 3 m H 3 S on pressure release below 140 GPa. Here, the latter phase is (meta)stable down to at least 70 GPa where it transforms to Cccm H 3 S upon annealing (T < 1300 K) to overcome the kinetic hindrance. Cccm H 3 S has an extended structure with symmetric hydrogen bonds at 50 GPa, and upon decompression it experiences a transformation to a molecular mixed H 2 S – H 2 structure below 40 GPa without any apparent change in the crystal symmetry.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Treatment of Transient Pressure Events in Space Flight Pressurized Systems

A multi-disciplinary team from the NASA Engineering and Safety Center (NESC) and The Aerospace Corporation developed a roadmap on how to treat transients in spaceflight pressurized systems. This document presents a focused discussion on the topic of pressure transients for consideration within the aerospace community.

NASA Engineering and Safety Center↗

High pressure raman spectroscopy and X-ray diffraction of K2Ca(CO3)2 bütschliite: multiple pressure-induced phase transitions in a double carbonate

Abstract The crystal structure and bonding environment of K 2 Ca(CO 3 ) 2 bütschliite were probed under isothermal compression via Raman spectroscopy to 95 GPa and single crystal and powder X-ray diffraction to 12 and 68 GPa, respectively. A second order Birch-Murnaghan equation of state fit to the X-ray data yields a bulk modulus, $${K}_{0}=46.9$$ K 0 = 46.9 GPa with an imposed value of $${K}_{0}^{\prime}= 4$$ K 0 ′ = 4 for the ambient pressure phase. Compression of bütschliite is highly anisotropic, with contraction along the c -axis accounting for most of the volume change. Bütschliite undergoes a phase transition to a monoclinic C 2/ m structure at around 6 GPa, mirroring polymorphism within isostructural borates. A fit to the compression data of the monoclinic phase yields $${V}_{0}=322.2$$ V 0 = 322.2 Å 3 $$,$$ , $${K}_{0}=24.8$$ K 0 = 24.8 GPa and $${K}_{0}^{\prime}=4.0$$ K 0 ′ = 4.0 using a third order fit; the ability to access different compression mechanisms gives rise to a more compressible material than the low-pressure phase. In particular, compression of the C 2/ m phase involves interlayer displacement and twisting of the [CO 3 ] units, and an increase in coordination number of the K + ion. Three more phase transitions, at ~ 28, 34, and 37 GPa occur based on the Raman spectra and powder diffraction data: these give rise to new [CO 3 ] bonding environments within the structure.

36 MATERIALS SCIENCE↗

Ultra-High Resolution Elemental/Isotopic Mass Spectrometry (m/?m> 1,000,000): Coupling of the Liquid Sampling-Atmospheric Pressure Glow Discharge with an Orbitrap Mass Spectrometer for Applications in Biological Chemistry and Environmental Analysis

Many fundamental questions of astrophysics, biochemistry, and geology rely on the ability to accurately and precisely measure the mass and abundance of isotopes. Taken a step further, the capacity to perform such measurements on intact molecules provides insights into processes in diverse biological systems. Described here is the coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma, with a commercially available ThermoScientific Fusion Lumos mass spectrometer. Demonstrated for the first time is the ionization and isotopically-resolved fingerprinting of a long-postulated, but never mass-spectrometrically observed, bi-metallic complex Hg:Se-cysteine. Such a complex has been implicated as having a role in observations of Hg detoxification by selenoproteins/amino acids. Demonstrated as well is the ability to mass spectrometrically-resolve the geochronologically important isobaric 87Sr and 87Rb species (?m ~ 0.3 mDa, mass resolution m/?m ? 1,700,000). The mass difference in this case reflects the beta-decay of the 87Rb to the stable Sr isotope. These two demonstrations highlight what may be a significant change in bioinorganic and atomic mass spectrometry, with impact expected across a broad spectrum of the physical, biological and geological sciences.

Hoegg, Edward D.↗

High-resolution ultrahigh-pressure long column reversed-phase liquid chromatography for top-down proteomics

We report development of an approach providing high-resolution RPLC of proteins and its utility for mass spectrometry-based top-down proteomics. A chromatographic peak capacity of ~450 was achieved for proteins and large polypeptides having MWs up to 43 kDa in the context of proteomics applications. RPLC column lengths from 20 to 200 cm, particle sizes from 1.5 to 5 m, bonding alkyl chains from C1 to C2, C4, C8, and C18, and particle surface structures that spanned porous, superficially porous (porous shell, core-shell), and nonporous were investigated at pressures up to14K psi. Column length was found as the most important factor for >20 kDa proteins in gradient RPLC, and shortening column length degraded RPLC resolution and sensitivity regardless of the size and surface structure of the packing particles used. The alkyl chains bonded to the silica particle surface significantly affected the RPLC recovery and efficiency, and short alkyl C1-C4 phases provided higher sensitivity and resolution than C8 and C18 phases. Long gradient separations (e.g., >10 hours) with long columns (e.g., 100 cm) were particularly effective in conjunction with use of high accuracy mass spectrometers (e.g., the Orbitrap Elite) for top-down proteomics with improved proteoform coverage by allowing multiple HCD, CID, and ETD dissociation modes. It was also found that HCD produced small fragments useful for proteoform identification, while low energy CID and ETD often complemented HCD by providing large fragments.

columns and stationary phases↗

Comparison of vapour pressure osmometry, freezing point osmometry and direct membrane osmometry for determining the osmotic pressure of concentrated solutions

Osmometry is the analytical method of measuring osmotic pressure ($π$) and related colligative properties. Accurately measuring $π$ is essential for applications that use osmosis, including drug delivery systems and water filtration methods such as forward osmosis. The three most common forms of directly or indirectly measuring $π$ are vapour pressure osmometry (VPO), freezing point osmometry (FPO), and direct membrane osmometry (DMO). In this report, the performance of VPO, FPO, and DMO are compared for various aqueous solutions, including small molecule and polymer solutes, and potentially more difficult samples such as concentrated, carbonated, or viscous solutions. Furthermore, potential problems with each of the three methods are examined. Good practices can avoid inaccuracies in DMO due to external concentration polarization and solute diffusion through the membrane. Similarly, it is important to be aware of and avoid weaknesses in VPO and FPO in order to obtain reliable results. Even with care, however, the three methods still give different values of $π$ for concentrated aqueous solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗