Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Vapor-modulated heat pipe report. Flight data analysis and further development of variable-conductance heat pipes

The design and testing of a heat pipe for spacecraft application is presented. The application in mind calls for heat loads up to 20 watts, a set-point temperature of 294K, and a sink that varies from -220K to nearly as high as the set-point. The overall heat pipe length is 137 cm. Two basically different mechanisms of achieving variable conductance in the pipe by vapor-flow throttling were studied. In one, the thermal resistance between the heat source and sink is due to a saturation-temperature drop corresponding to the vapor-pressure drop developed across the valve. In the other, the pressure difference across the valve induces capillary groove and wick dry out in an evaporation region, and thus results in an increased thermal resistance. This mechanism was selected for fabrication and testing. The pipe is a stainless-steel/methanol two-heat-pipe system. Results are presented and discussed. Engineering drawings and specifications of the pipe are shown.

Eninger, J. E.↗

Distribution and observed associations of orthostatic blood pressure changes in elderly general medicine outpatients

Factors associated with orthostatic blood pressure change in elderly outpatients were determined by surveying 398 medical clinical outpatients aged 65 years and older. Blood pressure was measured with random-zero sphygmomanometers after patients were 5 minutes in a supine and 5 minutes in a standing position. Orthostatic blood pressure changes were at normally distributed levels with systolic and diastolic pressures dropping an average of 4 mm Hg (standard deviation [SD]=15 mm Hg) and 2 mm Hg (SD=11 mm Hg), respectively. Orthostatic blood pressure changes were unassociated with age, race, sex, body mass, time since eating, symptoms, or other factors. According to multiple linear regression analysis, supine systolic pressure, chronic obstructive pulmonary disease (COPD), and diabetes mellitus were associated with a decrease in systolic pressure on standing. Hypertension, antiarthritic drugs, and abnormal heartbeat were associated with an increase in systolic pressure on standing. For orthostatic diastolic pressure changes, supine diastolic pressure and COPD were associated with a decrease in diastolic pressure on standing. Congestive heart failure was associated with an increase in standing diastolic pressure. Using logistic regression analysis, only supine systolic pressure was associated with a greater than 20-mm Hg drop in systolic pressure (n=53, prevalence=13%). Supine diastolic pressure and COPD were the only variables associated with a greater than 20-mm Hg drop in diastolic pressure (n=16, prevalence=4%). These factors may help physicians in identifying older persons at risk for having orthostatic hypotension.

Non-NASA Center↗

Remotely operated high pressure valve protects test personnel

High pressure valve used in testing certain spacecraft systems is safely opened and closed by a remotely stationed operator. The valve is self-regulating in that if the incoming pressure drops below a desired value the valve will automatically close, warning the operator that the testing pressure has dropped to an undesired level.

Howland, B. T.↗

System and Component Transport Considerations of Micro-Pin Based Solar Receivers With High Temperature Gaseous Working Fluids

This paper explores the interactions between micro-pin concentrated receiver designs with overall solar thermal energy system performance, with different operating conditions, working fluid, and required materials of construction. A 320 MW thermal plant coupled to a 160 MW electric sCO2 Brayton cycle is considered as the baseline. The circulating fluid enters the receiver at 550°C, and leaves at 720°C. The thermal storage/power block are located 150 m from the receiver at the base of the receiver tower. A resistance network based thermal and hydraulic model is used to predict heat transfer and pressure drop performance of the micro-pin receiver. This output of this model is coupled to a system level model of the pressure loss and compressor power required in the remainder of the high temperature gas loop. Overall performance is investigated for supercritical carbon dioxide and helium as working fluids, at pressures from 7.5 to 25 MPa, and at delivery temperatures of 720°C. The results show that by modifying pin depth and flow lengths, there are design spaces for micro-pin devices that can provide high thermal performance without significantly reducing the overall solar thermal system output at lower operating pressures. Use of lower pressure fluids enables lower cost materials of construction in the piping and distribution system, reducing the cost of electricity.

14 SOLAR ENERGY↗

Fast production of ultracold sodium gases using light-induced desorption and optical trapping

In this article we report on the production of a Bose-Einstein condensate (BEC) of {sup 23}Na using light-induced desorption as an atomic source. We load about 2x10{sup 7} atoms in a magneto-optical trap (MOT) from this source with a {approx}6 s loading time constant. The MOT lifetime can be kept around 27 s by turning off the desorbing light after loading. We show that the pressure drops down by a factor of 40 in less than 100 ms after the extinction of the desorbing light, restoring the low background pressure for evaporation. Using this technique, a BEC with 10{sup 4} atoms is produced after a 6 s evaporation in an optical dipole trap.

74 ATOMIC AND MOLECULAR PHYSICS↗

Differential retention and release of CO 2 and CH 4 in kerogen nanopores: Implications for gas extraction and carbon sequestration

Methane (CH 4 ) and carbon dioxide (CO 2 ), the two major components generated from kerogen maturation, are stored dominantly in nanometer-sized pores in shale matrix as (1) a compressed gas, (2) an adsorbed surface species and/or (3) a species dissolved in pore water (H 2 O). In addition, supercritical CO 2 has been proposed as a fracturing fluid for simultaneous enhanced oil/gas recovery (EOR) and carbon sequestration. A mechanistic understanding of CH 4 -CO 2 -H 2 O interactions in shale nanopores is critical for designing effective operational processes. Using molecular simulations, we show that kerogen preferentially retains CO 2 over CH 4 and that the majority of CO 2 either generated during kerogen maturation or injected in EOR will remain trapped in the kerogen matrix. The trapped CO 2 may be released only if the reservoir pressure drops below the supercritical CO 2 pressure. When water is present in the kerogen matrix, it may block CH 4 release. Furthermore, the addition of CO 2 may enhance CH 4 release because CO 2 can diffuse through water and exchange for adsorbed methane in the kerogen nanopores.

03 NATURAL GAS↗

Research and Education of CO{sub 2} Separation from Coal Combustion Flue Gases with Regenerable Magnesium Solutions

A novel method using environment-friendly chemical magnesium hydroxide (Mg(OH) 2 ) solution to capture carbon dioxide from coal-fired power plants flue gas has been studied under this project in the post-combustion control area. The project utilizes the chemistry underlying the CO 2 -Mg(OH) 2 system and proven and well-studied mass transfer devices for high levels of CO 2 removal. The major goals of this research were to select and design an appropriate absorber which can absorb greater than 90% CO 2 gas with low energy costs, and to find and optimize the operating conditions for the regeneration step. During the project period, we studied the physical and chemical characteristics of the scrubbing agent, the reaction taking place in the system, development and evaluation of CO 2 gas absorber, desorption mechanism, and operation and optimization of continuous operation. Both batch and continuous operations were performed to examine the effects of various parameters including liquid-to-gas ratio, residence time, lean solvent concentration, pressure drop, bed height, CO 2 partial pressure, bubble size, pH, and temperature on the absorption.

20 FOSSIL-FUELED POWER PLANTS↗

Project: Enabling Technologies for Oxy-fired Pressurized Fluidized Bed Combustor Systems (Final Project)

GTI and team members CanmetENERGY and Linde worked on developing technologies at the pilot-scale to significantly improve the performance and economics of current oxy-fired pressurized fluidized bed combustor systems and reduce scale up risk. The technologies include: an In-bed Supercritical CO 2 (SCO 2 ) Heat Exchanger, the objective being to quantify SCO 2 heat transfer coefficients and pressure drop in an Oxygen-fired pressurized fluidized bed combustor (Oxy-PFBC) environment to anchor design rules for scale up; Staged Coal Combustion, the objective being to develop design rules for placement of staged coal combustion injectors to appropriately distribute heat throughout the bed to maintain an oxidizing environment and avoid slagging; and an Isothermal Deoxidation Reactor, the objective being to define operational limits on flue gas O 2 concentration for an isothermal catalyst bed and demonstrate heat recovery from this deoxidation unit. In-bed SCO 2 heat exchanger manifolds were successfully manufactured and installed in the combustor at CanmetENERGY. Staged fuel injectors were designed and fabricated. A task to test an oxygen carrier in the fluidized bed was also planned. A Quasi-Isothermal Deoxidation Reactor (Q-IDR) concept was developed and fabricated, consisting of two adiabatic catalytic reactors with a single inter-stage cooler with SCO 2 as the coolant. The project was stopped prior to testing these technologies due to damage to the hardware on the related Oxy-PFBC Phase II project (DE-FE0009448).

20 FOSSIL-FUELED POWER PLANTS↗

Thermal structure of the atmosphere of Venus from Pioneer Venus radio occultations

The processing and analysis results from 87 radio occultation experiments performed with the Pioneer Venus Orbiter are detailed. Atmospheric structure data were obtained with S-band (2293 MHz) and X-band (8407 MHz) signals transmitted through the 40 and 85 km levels of the Venus atmosphere. Latitudes of -68 to 88 deg at solar zenith angles of 8-166 deg were explored. The conversion of the data into acceptable form for the barometric equation to use the perfect gas law to obtain the temperature profiles is described. The temperature structures were more dependent on latitude than solar illumination conditions, with the greatest changes occurring in the circumpolar region. The polar tropopause altitude was about 4.8 km above its value at lower altitudes, with a temperature drop of 60 K and a pressure drop of 240 mb.

Kliore, A. J.↗

History of water on Mars - A biological perspective

A general scenario is developed for the history of liquid water on the surface of Mars, according to which the history of water on Mars can be divided into four epochs based on the fundamental temperature and pressure characteristics. In Epoch I, the mean annual temperature is assumed to have been above freezing and the pressure to have been above 1 atm; liquid water was widespread and life could have arisen and become abundant. In Epoch II, the mean annual temperature fell below freezing, but peak temperatures were above freezing; In Epoch II ice-covered lakes could have provided a habitat for life. In Epoch III, both the mean and the peak temperatures were below freezing, and only transient liquid water would be possible; under these conditions, microbial ecosystems living in endolithic rock 'greenhouses' could have continued to survive. Finally, in Epoch IV, the pressure dropped to near the triple point pressure of water; at this stage, life on the surface of Mars would have become extinct.

Mckay, Christopher P.↗

Shear coaxial injector instability mechanisms

Although stable operating regimes for cryogenic coaxial injectors have been empirically determined, there is no knowledge of the spray characteristics corresponding to stable operation, or the physical processes which produce the atomization patterns that result in stable or unstable operation. The current engineering method for determining the stable operating regime of a cryogenic coaxial injector is the 'hydrogen temperature ramping' method, however there is no definitive knowledge of whether the hydrogen temperature influences the chamber stability by decreasing the injected gas velocity, by affecting a recirculation region at the base of the LOX Post, or by changing the pressure drop across the injector, allowing chamber pressure oscillations to couple to the fuel feed system. Results for the injector response from a linearized lumped-element model are presented as a function of temperature and frequency. LDV measurements in the recess region at the base of the LOX post show reverse flow indicative of a recirculation region. Finally, Phase Doppler Particle Analyzer (PDPA) measurements of droplet size and velocity distributions are discussed for a coaxial injector element similar to the SSME preburner element operating with water and air at atmospheric pressure and liquid and gaseous nitrogen at 20 bars.

Kaltz, T.↗

Bubble confinement in flow boiling of FC-72 in a ''rectangular'' microchannel of high aspect ratio

Boiling in microchannels remains elusive due to the lack of full understanding of the mechanisms involved. A powerful tool in achieving better comprehension of the mechanisms is detailed imaging and analysis of the two-phase flow at a fundamental level. Boiling is induced in a single microchannel geometry (hydraulic diameter 727 {mu}m), using a refrigerant FC-72, to investigate the effect of channel confinement on bubble growth. A transparent, metallic, conductive deposit has been developed on the exterior of the rectangular microchannel, allowing simultaneous uniform heating and visualisation to be achieved. The data presented in this paper is for a particular case with a uniform heat flux applied to the microchannel and inlet liquid mass flowrate held constant. In conjunction with obtaining high-speed images and videos, sensitive pressure sensors are used to record the pressure drop across the microchannel over time. Bubble nucleation and growth, as well as periodic slug flow, are observed in the microchannel test section. The periodic pressure fluctuations evidenced across the microchannel are caused by the bubble dynamics and instances of vapour blockage during confined bubble growth in the channel. The variation of the aspect ratio and the interface velocities of the growing vapour slug over time, are all observed and analysed. We follow visually the nucleation and subsequent both 'free' and 'confined' growth of a vapour bubble during flow boiling of FC-72 in a microchannel, from analysis of our results, images and video sequences with the corresponding pressure data obtained. (author)

42 ENGINEERING↗

A merger shock in A2034

We present a 250 ks Chandra observation of the cluster merger A2034 with the aim of understanding the nature of a sharp edge previously characterized as a cold front. The new data reveal that the edge is coherent over a larger opening angle and is significantly more bow-shock-shaped than previously thought. Within ∼27° about the axis of symmetry of the edge, the density, temperature, and pressure drop abruptly by factors of 1.83{sub −0.08}{sup +0.09}, 1.85{sub −0.41}{sup +0.41}, and 3.4{sub −0.7}{sup +0.8}, respectively. This is inconsistent with the pressure equilibrium expected of a cold front and we conclude that the edge is a shock front. We measure a Mach number M=1.59{sub −0.07}{sup +0.06} and corresponding shock velocity v {sub shock} ≅ 2057 km s{sup –1}. Using spectra collected at the MMT with the Hectospec multi-object spectrograph, we identify 328 spectroscopically confirmed cluster members. Significantly, we find a local peak in the projected galaxy density associated with a bright cluster galaxy that is located just ahead of the nose of the shock. The data are consistent with a merger viewed within ∼23° of the plane of the sky. The merging subclusters are now moving apart along a north-south axis approximately 0.3 Gyr after a small impact parameter core passage. The gas core of the secondary subcluster, which was driving the shock, appears to have been disrupted by the merger. Without a driving 'piston,' we speculate that the shock is dying. Finally, we propose that the diffuse radio emission near the shock is due to the revival of pre-existing radio plasma that has been overrun by the shock.

79 ASTRONOMY AND ASTROPHYSICS↗