Preparing for the Plug-In Surge
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
NREL presentation about a study estimating the tangible value of public electric vehicle charging infrastructure to the consumer during a panel discussion at the University of Michigan Conference on Transportation, Economics, Energy and the Environment on October 18, 2019.
This is a Spanish-language handbook designed to answer a consumer's basic questions, as well as point them to additional information they need, to make the best decision about whether an electric-drive vehicle is right for them.
The U.S. Department of Energy’s Alternative Fuels Data Center (AFDC) has tracked alternative fueling and electric vehicle charging infrastructure in the United States since 1991. This paper explores the history of the AFDC Station Locator, which was launched in 1999, and discusses the growth of electric vehicle supply equipment. It also looks at how electric vehicle drivers access public charging, and evaluates challenges, gaps, and opportunities facing both electric vehicle drivers and the industry as a whole.
Photovoltaic connectors are designed to be quick and easy to install. Current connector qualification standards, such as UL 6703 and IEC 62852, are only intended to evaluate connectors from the same manufacturer and were recently changed to explicitly proscribe the mating of connectors from different manufacturers. Unfortunately, the industry has chosen to design connectors that will commonly connect together with those from other manufacturers. This is done to simplify installation avoiding the situations such as when the connectors on a microinverter, or other module level power electronics, do not match the connectors on the modules in the system. This rampant violation of electrical codes worldwide indicates that there is a strong desire and need to develop a universal connector standard. Here we present the initial approach and philosophy behind the formation of an IEC subgroup under TC82 WG2 looking at this problem. We intend to develop a standard where the materials and geometry of construction are specified to ensure compatibility and the design is intended to be of the highest quality. We expect that this connector will be more costly but especially in rooftop installations where power electronics requires matching components from several manufacturers, that this may still result in a net cost savings. These connectors must be of the highest quality because we wouldn’t want to develop a connector that precluded the manufacturing of a higher quality product, and because these will most commonly be used on rooftop installations where safety is more of a concern. Additionally, because we do not know which brands of connectors will be used together, we cannot simply rely on test results to ensure safety but must create a design that is as inherently safe as possible.
No abstract prepared.
PurposePTC and stenting procedures are associated with significant risks including life-threatening haemorrhage, sepsis, renal failure and high mortality rates. PTC tract closure methods are utilised to reduce haemorrhagic complications despite little evidence to support their use. The current study assesses the incidence of haemorrhagic complications following PTC and stenting procedures, both prior to and following the introduction of a dedicated expanding gelatin foam-targeted embolisation liver tract closure technique.Materials and MethodsHaemorrhagic complications were retrospectively identified in patients undergoing PTC procedures both prior to (subgroup 1) and following (subgroup 2) the introduction of a dedicated targeted liver tract closure method between 9/11/2010 and 10/08/2012 in a single tertiary referral centre. Mean blood Hb decrease following PTC was established in subgroups 1 and 2. Kaplan–Meier life-table analysis was performed to compare survival outcomes between subgroups using the log-rank test.ResultsHaemorrhagic complications were significantly reduced following the introduction of the targeted PTC tract closure method [(12 vs. 3 % of subgroups 1 (n = 101) and 2 (n = 92), respectively (p = 0.027)]. Mean blood Hb decrease following PTC was 1.40 versus 0.68 g/dL in subgroups 1 and 2, respectively (p = 0.069). 30-day mortality was 14 and 12 % in subgroups 1 and 2, respectively. 50 % of the entire cohort had died by 174 days post-PTC.ConclusionIntroduction of liver tract embolisation significantly reduced haemorrhagic complications in our patient cohort. Utilisation of this method has the potential to reduce the morbidity and mortality burden associated with post-PTC haemorrhage by preventing bleeding from the liver access tract.
No abstract prepared.
No abstract prepared.
No abstract prepared.
No abstract prepared.
No abstract prepared.