Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLASTICITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

A new water-equivalent 2D plastic scintillation detectors array for the dosimetry of megavoltage energy photon beams in radiation therapy

Purpose: The objective of this work is to present a new 2D plastic scintillation detectors array (2D-PSDA) designed for the dosimetry of megavoltage (MV) energy photon beams in radiation therapy and to characterize its basic performance. Methods: We developed a 2D detector array consisting of 781 plastic scintillation detectors (PSDs) inserted into a plane of a water-equivalent phantom. The PSDs were distributed on a 26 x 26 cm{sup 2} grid, with an interdetector spacing of 10 mm, except for two perpendicular lines centered on the detection plane, where the spacing was 5 mm. Each PSD was made of a 1 mm diameter by 3 mm long cylindrical polystyrene scintillating fiber coupled to a clear nonscintillating plastic optical fiber. All of the light signals emitted by the PSDs were read simultaneously with an optical system at a rate of one measurement per second. We characterized the performance of the optical system, the angular dependency of the device, and the perturbation of dose distributions caused by the hundreds of PSDs inserted into the phantom. We also evaluated the capacity of the system to monitor complex multileaf collimator (MLC) sequences such as those encountered in step-and-shoot intensity modulated radiation therapy (IMRT) plans. We compared our results with calculations performed by a treatment planning system and with measurements taken with a 2D ionization chamber array and with a radiochromic film. Results: The detector array that we developed allowed us to measure doses with an average precision of better than 1% for cumulated doses equal to or greater than 6.3 cGy. Our results showed that the dose distributions produced by the 6-MV photon beam are not perturbed (within {+-}1.1%) by the presence of the hundreds of PSDs located into the phantom. The results also showed that the variations in the beam incidences have little effect on the dose response of the device. For all incidences tested, the passing rates of the gamma tests between the 2D-PSDA and the treatment planning system were higher than 97.5% when the standard clinical tolerances of 3% or 3 mm were used. Excellent agreement was obtained between the doses measured and calculated when we used the 2D-PSDA for monitoring a MLC sequence from a step-and-shoot IMRT plan. Conclusions: We demonstrated the feasibility of using a large number of PSDs in a new 2D-PSDA for the dosimetry of MV energy photon beams in radiation therapy. The excellent precision, accuracy, and low angular dependence of the device indicate that such a prototype could potentially be used as a high-accuracy quality assurance tool for IMRT and arc therapy patient plan verification. The homogeneity and water-equivalence of the prototype we built suggest that this technology could be extended to multiple detection planes by arranging the fibers into more complex orientations, opening the possibility for 3D dosimetry with PSDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers

Purpose: Most electronic portal imaging devices (EPIDs) developed so far use a thin Cu plate/phosphor screen to convert x-ray energies into light photons, while maintaining a high spatial resolution. This results in a low x-ray absorption and thus a low quantum efficiency (QE) of approximately 2-4% for megavoltage (MV) x-rays. A significant increase of QE is desirable for applications such as MV cone-beam computed tomography (MV-CBCT). Furthermore, the Cu plate/phosphor screen contains high atomic number (high-Z) materials, resulting in an undesirable over-response to low energy x-rays (due to photoelectric effect) as well as high energy x-rays (due to pair production) when used for dosimetric verification. Our goal is to develop a new MV x-ray detector that has a high QE and uses low-Z materials to overcome the obstacles faced by current MV x-ray imaging technologies. Methods: A new high QE and low-Z EPID is proposed. It consists of a matrix of plastic scintillating fibers embedded in a water-equivalent medium and coupled to an optically sensitive 2D active matrix flat panel imager (AMFPI) for image readout. It differs from the previous approach that uses segmented crystalline scintillators made of higher density and higher atomic number materials to detect MV x-rays. The plastic scintillating fibers are focused toward the x-ray source to avoid image blurring due to oblique incidence of off-axis x-rays. When MV x-rays interact with the scintillating fibers in the detector, scintillation light will be produced. The light photons produced in a fiber core and emitted within the acceptance angle of the fiber will be guided toward the AMFPI by total internal reflection. A Monte Carlo simulation has been used to investigate imaging and dosimetric characteristics of the proposed detector under irradiation of MV x-rays. Results: Properties, such as detection efficiency, modulation transfer function, detective quantum efficiency (DQE), energy dependence of detector response, and water-equivalence of dose response have been investigated. It has been found that the zero frequency DQE of the proposed detector can be up to 37% at 6 MV. The detector, also, is water-equivalent with a relatively uniform response to different energy x-rays as compared to current EPIDs. Conclusions: The results of our simulations show that, using plastic scintillating fibers, it is possible to construct a water-equivalent EPID that has a better energy response and a higher detection efficiency than current flat panel based EPIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-50: Study On the Magnetic Field Effect On the Exradin W1 Plastic Scintillation Detector

Purpose: To study the response of the Exradin W1 plastic scintillator detector to a 6 MV photon field in the presence of a strong magnetic field (B). Methods: An Exradin W1 scintillator detector coupled to a SuperMax two-channel electrometer, both manufactured by Standard Imaging, Inc., was first calibrated in a Co-60 beam. The Cerenkov Light Ratio (CLR) was obtained following the procedure recommended by the manufacturer. Subtracting signal in channel 2 multiplied by CLR from the signal in channel 1 should lead to a Cerenkov-free signal. The W1 scintillator was placed in a plastic phantom inside a dipole electromagnet (GMW Associates) that could produce a strong B field, and irradiated using a 6 MV beam from an Elekta Versa HD LINAC. Signals from both channels of the W1 scintillator were acquired as a function of B (0 - 1.5 T). Results: The signals from both channels increased as a function of the B field strength. At 1.5 T, channel 1 increased by 11% compared to the baseline (B=0 T), while channel 2 increased by 22%. Applying the recommended Cerenkov correction led to a 2% difference between dose measurement with and without a magnetic field. The values between B=0.3 T and B=1.5 T remained constant. Conclusion: Signals from the Exradin W1 plastic scintillation detector increased as the B field increased. This increase mainly comes from a change in the amount of Cerenkov light coupled within the optical fiber. Removing the Cerenkov component following the procedure recommended by the manufacturer showed to be an effective way to measure dose accurately in strong magnetic fields. The cause for the residual 2% difference is currently under investigation. We acknowledge research support from Elekta AB.

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-12: Impact of a Magnetic Field On the Response From a Plastic Scintillation Detector

Purpose: To study the effect of a strong magnetic field on the scintillation and the stem effect from a plastic scintillation detector (PSD) and evaluate its accuracy to measure dose. Methods: A plastic scintillation detector and a bare plastic fiber were placed inside a magnet of adjustable field strength (B=0−1.5T) and irradiated by a 6-MV photon beam (Elekta Versa HD LINAC). The PSD was built in-house using a scintillating fiber (BCF-60, 3-mm long × 1-mm diameter) coupled to an optical fiber similar to the bare fiber (PMMA, 12-m long, 1-mm diameter). Light output spectra were acquired with a spectrometer. Intensity and shape of the output spectra were compared as a function of the magnetic field strength. The bare fiber was used to study the behavior of the stem effect (composed of Cerenkov and fluorescence). The spectrometry setup allowed to perform a previously demonstrated hyperspectral stem-effect removal and calculated dose was studied as a function of the magnetic field strength. Results: Signal intensities were shown to increase with the magnetic field strength by up to 19% and 79% at 1.5T in comparison to the irradiation without a magnetic field, for respectively the PSD and the bare fiber. The light produced by Cerenkov effect in the optical fiber was shown to be the major component affected by the magnetic field. Effect of the magnetic field on the electrons trajectory may explain this behavior. Finally, accounting for the stem effect using the hyperspectral approach led to accuracy in dose measurement within 2.6%. Interestingly, variations in accuracy were negligible for values over 0.3T. Conclusion: Dependence of PSDs to magnetic field is mainly due to the Cerenkov light. When accounting for it, PSDs become a candidate of choice for both quality assurance and in vivo dosimetry of therapy under strong magnetic fields (e.g. for MRI-Linacs).

60 APPLIED LIFE SCIENCES↗

Model of Nanostructuring Burnishing by a Spherical Indenter Taking into Consideration Plastic Deformations

A dynamic model of the nanostructuring burnishing of a surface of metallic details taking into consideration plastic deformations has been suggested. To describe the plasticity, the ideology of dimension reduction method supplemented with the plasticity criterion is used. The model considers the action of the normal burnishing force and the tangential friction force. The effect of the coefficient of friction and the periodical oscillation of the burnishing force on the burnishing kinetics are investigated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Correlation between Characteristics of Macrolocalized Plastic Deformation and Parameters of the Electronic Structure of Metals

The correlation between lattice characteristics of a deformed medium and parameters of autowaves of a localized plastic flow in metals at the stage of linear strain hardening is considered. Such correlation testifies for the existence of a close connection between elastic and plastic deformations of the medium and, more generally, between characteristics of plasticity and electronic structure of elements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polycrystal Plasticity: Comparison Between Grain - Scale Observations of Deformation and Simulations

Here, the response of polycrystals to plastic deformation is studied at the level of variations within individual grains, and comparisons are made to theoretical calculations using crystal plasticity (CP). We provide a brief overview of CP and a review of the literature, which is dominated by surface observations. The motivating question asks how well does CP represent the mesoscale behavior of large populations of dislocations (as carriers of plastic strain). The literature shows consistently that only moderate agreement is found between experiment and calculation. We supplement this with a current example of microstructure evolution in the interior of a copper sample subjected to tensile deformation. Nondestructive measurements of orientation fields were performed using the near-field high-energy X-ray diffraction microscopy (nf-HEDM) technique at the Advanced Photon Source (APS). Starting at highly ordered grains, a single two-dimensional slice of microstructure containing ~150 grains was followed through multiple strain states, where it tracked lattice rotations and defect accumulation of up to 14% elongation. In accord with the literature, at the scale of individual grains, comparison of observations with CP models indicates reasonable qualitative agreement but significant variations between simulation and experiment are apparent. The conclusion is that in order to be able to quantify the effects of microstructure on the distributions of slip, orientation change, and damage accumulation, the empirically derived constitutive relations used in continuum-scale simulations need to be improved. Equally important will be the development of large-scale simulations of polycrystals that directly model dislocations.

36 MATERIALS SCIENCE↗

Insights into Plastic Localization by Crystallographic Slip from Emerging Experimental and Numerical Approaches

Advanced experimental and numerical approaches are being developed to capture the localization of plasticity at the nanometer scale as a function of the multiscale and heterogeneous microstructure present in metallic materials. These innovative approaches promise new avenues to understand microstructural effects on mechanical properties, accelerate alloy design, and enable more accurate mechanical property prediction. This article provides an overview of emerging approaches with a focus on the localization of plasticity by crystallographic slip. New insights into the mechanisms and mechanics of strain localization are addressed. The consequences of the localization of plasticity by deformation slip for mechanical properties of metallic materials are also detailed.

36 MATERIALS SCIENCE↗

Stress- and Radiation-Induced Swelling in Plastic Capsules

The process of filling targets with D-T for cryogenic experiments on the OMEGA laser induces small-scale features on the inner surface of the plastic capsules. Each feature was a cluster of low-level domes (< 0.1 um high) with individual lateral dimensions < 5 um that collectively covered lateral dimensions of up to 300 um 2 . These features were observed only when a high radiation dose was combined with high stress in the plastic wall, as occurs when the capsules are permeation filled and transferred at cryogenic temperatures. No porosity or void structure was observed in or below these domes. It is speculated that the domes are a swelling caused by radiation-induced bond scission and chemical restructuring that reduces the plastic density in localized regions.

tritium-induced damage, plastic capsule↗

Industrial Scalable Additives for Enhanced Decomposition of Plastic Waste Through Photocatalysis

Polymer pollution is a dangerous environmental problem that can lead to the spread of toxic chemicals and microplastics throughout aquatic biomes. Commonly littered plastic from consumer goods and products with a limited or single use can be embedded with photocatalysts to avoid an increase in the amount of plastic present in Earth’s bodies of water. In this work, the photocatalyst nanoparticles, less than 100 nm particle size, were integrated into polyethylene terephthalate, high-density polyethylene, low-density polyethylene, and polystyrene and exposed under ultraviolet light over two independent experimental trials examining both the environmental factors impacting decay and the physical parameters required to implement this solution on a large scale. The plastics were chosen due to their prolific use in items such as grocery bags, bottles, and packaging. The first half of the project examined the effects of water and light frequency on polymer decay, and the second half of the project examined photodecomposition of polymer films. We report that low-density and high-density polyethylene films with titanium dioxide decayed approximately 11.7 and 9.6 faster than control samples, respectively. With an estimated price of less than half the cost of a shopping bag for titanium catalyst integration and a retention of the polymer’s tensile strength with a 2 wt% catalyst concentration, photocatalytic decomposition is a feasible, scalable method for the prevention and future reduction of polymer waste from realistic products littered in the environment.

36 MATERIALS SCIENCE↗

Large-Scale Molecular Dynamics Simulations of Shock Induced Plasticity in Tantalum Single Crystals

We report on large-scale non-equilibrium molecular dynamics (NEMD) simulations of shock wave compression in Ta single crystals. The atomic interactions are modeled via a recently developed and optimized embedded-atom method (EAM) potential for Ta, which reproduces the equation of state up to 200 GPa. We examined the elastic-plastic transition and shock wave structure for wave propagation along the low index directions: (100), (110) and (Ill). Shock waves along (100) and (Ill) exhibit an elastic precursor followed by a plastic wave for particle velocities below 1.1 kmls for (100) and 1.4 km/s for (Ill). The nature of the plastic deformation along (lID) is dominated by twin ning for pressures above 41 GPa.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance Testing of a Moving-Bed Gasifier Using Coal, Biomass, and Waste Plastic Blends to Generate White Hydrogen

The objective of this DOE-funded project by the Electric Power Research Institute, Inc. (EPRI), Hamilton Maurer International (HMI) and Sotacarbo S.p.A. (Sotacarbo), is to qualify coal, biomass, and plastic waste blends based on performance testing of selected pellet recipes in a pilot-scale updraft moving-bed gasifier. The testing provides relevant data to advance the commercial-scale design of the moving-bed gasifier to be able to successfully use these feedstocks to produce hydrogen. In particular, the effects of the waste plastics on feedstock development (i.e., blending and pelletizing) and the resulting products (i.e., syngas compositions, organic condensate production, and ash characteristics) are a focus. The gasifier is Hamilton Mauer International, Inc. (HMI)’s moving-bed gasifier, which has been proven capable of gasifying nearly all coal ranks. It has also shown the ability in prior testing work to gasify wood chips. However, mixtures of these fuels with plastic wastes had not yet been prepared and gasified together. The feedstocks were prepared by California Pellet Mill (CPM) under contract to HMI.

01 COAL, LIGNITE, AND PEAT↗

Development and Characterization of Densified Biomass-plastic Blend for Entrained Flow Gasification (Final Technical Report)

Supported by the U.S. DOE NETL Award DE-FE0032043, this project was a collaborative effort. Project participants included the University of Kentucky Institute for Decarbonization and Energy Advancement (UK IDEA), Biosystems and Agricultural Engineering department (UK BAE), and Wabash Valley Resources, LLC. The goal of this final technical project report is to comprehensively summarize the work conducted on project DE-FE0032043. In accordance with the Statement of Project Objectives (SOPO), the University of Kentucky (UK) (Project Prime Recipient) has developed and studied a biomass/plastic fuel with a hydrophobic surface area less than 10 m 2 /m 3 that is suitable for oxygen-blown entrained flow gasification with slurry feed. The project involved the utilization of an existing thermogravimetric analysis (TGA)-mass spectrometer (MS), 1.5” drop tube furnace, 1 ton per day (TPD) coal gasifier, and high-pressure extruder operated at UK. The pilot-scale production of blended material was done at the Polymers Technology Center in Charlotte, North Carolina. Parametric testing and solid fuel blend slurry performance validation was completed using the UK entrained flow gasifier with multiple opposed burners to narrow the major near-term technical gaps that impede gasification of biomass and carbonaceous mixed wastes such as plastics in order to achieve net-negative CO 2 emissions. Project results validated the UK approach to address the major technical challenges on the biomass/plastic pretreatment and gasification. Previously, this has been limited in application to fluidized-type or moving bed-type gasifiers due to the high-water uptake of porous biomass containing hydroxyl groups during the conventional slurry preparation, resulting in a highly viscous, un-pumpable slurry. The biomass pretreatment with plastic developed for this project demonstrates advantages in cost and flexibility, which include: 1) the development of a blended solid fuel slurry with 55-60 wt% solids and comparable heating value to 100% coal-based water slurry; 2) the collection of gasification kinetic data and identification of preliminary operating conditions by performing thermogravimetric analysis, gasification experiments by using a 1.5” drop tube furnace; and finally 3) the demonstrated gasification of the blended solid fuel in the UK entrained flow gasifier with a long-lasting stable solid fuel blend slurry, dataset detailing operating conditions, and characterization of slag phase formation and solidification. The lab-scale data and experience obtained during this project encourages the development of technologies and commercial approaches to enable a hydrogen-based energy economy while achieving net-negative CO 2 emissions through gasification of coal, biomass, and carbonaceous mixed wastes such as plastics.

01 COAL, LIGNITE, AND PEAT↗

Hydrocracking Plastic Mixtures into Xylene

Our research aims to tackle the challenge in recycling end-of-life plastics, the accumulation of which has become a grand challenge to our society, sustainability and economy. Guided by life-cycle assessment (LCA) and tech-economic analysis (TEA), we specifically target the catalytic conversion of low-cost #3-7 plastic mixtures ($\$$5/ton) into p-xylene (>$\$$1000/ton), one of the most valuable hydrocarbon products. This goal is achieved by carrying out integrated research including catalysis, process engineering, and reactor design. The ultimate goal of this project is to enable energy-efficient and economically viable depolymerization of end-of-life plastic mixtures into value-added commodity chemicals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlling the Plastic Anisotropy of Magnesium Alloy by Tailoring the Grain Size and Yttrium Content

Hexagonal close-packed (HCP) magnesium alloys are widely used in automotive and aerospace industries due to their low density and high specific-strength. Their applicability is mainly restricted due to poor formability and pronounced plastic anisotropy. The formability is usually improved by altering the chemistry (adding rare-earth elements like Y) or modulating the microstructure (e.g., grain refinement). However, grain refinement alone cannot yield the desired ductility, and the scarcity of rare-earth elements also limits the extent to which the alloying strategy can be used. To overcome these issues, in this work, it is proposed that the formability of Mg alloys can be improved by combining the grain refinement and alloying approaches. To quantitively explore this possibility, a crystal-plasticity-based constitutive model, which is sensitive to both alloying concentration and grain sizes, is developed. To demonstrate, the model is applied to study the combined effect of Y content and grain size on the mechanical responses of Mg alloy. The calculations are used to build maps of plastic anisotropy measures, such as tension–compression asymmetry ratio and Lankford coefficients, for a wide range of Y content and grain sizes. From these maps, the grain size that would yield the desired performance of Mg alloy for a fixed Y content can be identified. This work provides an accelerated pathway to optimize both the microstructure and chemistry simultaneously to achieve formability and to reduce the dependence on alloying.

36 MATERIALS SCIENCE↗

Bending Nanoindentation and Plasticity Noise in FCC Single and Polycrystals

We present a high-throughput nanoindentation study of in situ bending effects on incipient plastic deformation behavior of polycrystalline and single-crystalline pure aluminum and pure copper at ultranano depths (< 200 nm). We find that hardness displays a statistically inverse dependence on in-plane stress for indentation depths smaller than 10 nm, and the dependence disappears for larger indentation depths. In contrast, plastic noise in the nanoindentation force and displacement displays statistically robust noise features, independently of applied stresses. Our experimental results suggest the existence of a regime in Face Centered Cubic (FCC) crystals where ultranano hardness is sensitive to residual applied stresses, but plasticity pop-in noise is insensitive to it.

36 MATERIALS SCIENCE↗

Theoretical Development of an Orthotropic Elasto-Plastic Generalized Composite Material Model

The need for accurate material models to simulate the deformation, damage and failure of polymer matrix composites is becoming critical as these materials are gaining increased usage in the aerospace and automotive industries. While there are several composite material models currently available within LSDYNA (Livermore Software Technology Corporation), there are several features that have been identified that could improve the predictive capability of a composite model. To address these needs, a combined plasticity and damage model suitable for use with both solid and shell elements is being developed and is being implemented into LS-DYNA as MAT_213. A key feature of the improved material model is the use of tabulated stress-strain data in a variety of coordinate directions to fully define the stress-strain response of the material. To date, the model development efforts have focused on creating the plasticity portion of the model. The Tsai-Wu composite failure model has been generalized and extended to a strain-hardening based orthotropic yield function with a nonassociative flow rule. The coefficients of the yield function, and the stresses to be used in both the yield function and the flow rule, are computed based on the input stress-strain curves using the effective plastic strain as the tracking variable. The coefficients in the flow rule are computed based on the obtained stress-strain data. The developed material model is suitable for implementation within LS-DYNA for use in analyzing the nonlinear response of polymer composites.

Polymer Matrix Composites↗

Theoretical Development of an Orthotropic Elasto-Plastic Generalized Composite Material Model

The need for accurate material models to simulate the deformation, damage and failure of polymer matrix composites is becoming critical as these materials are gaining increased usage in the aerospace and automotive industries. While there are several composite material models currently available within LS-DYNA (Registered), there are several features that have been identified that could improve the predictive capability of a composite model. To address these needs, a combined plasticity and damage model suitable for use with both solid and shell elements is being developed and is being implemented into LS-DYNA as MAT_213. A key feature of the improved material model is the use of tabulated stress-strain data in a variety of coordinate directions to fully define the stress-strain response of the material. To date, the model development efforts have focused on creating the plasticity portion of the model. The Tsai-Wu composite failure model has been generalized and extended to a strain-hardening based orthotropic material model with a non-associative flow rule. The coefficients of the yield function, and the stresses to be used in both the yield function and the flow rule, are computed based on the input stress-strain curves using the effective plastic strain as the tracking variable. The coefficients in the flow rule are computed based on the obtained stress-strain data. The developed material model is suitable for implementation within LS-DYNA for use in analyzing the nonlinear response of polymer composites.

Plasticity↗