Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Variable Sampling Mapping

The performance of an optical system (for example, a telescope) is limited by the misalignments and manufacturing imperfections of the optical elements in the system. The impact of these misalignments and imperfections can be quantified by the phase variations imparted on light traveling through the system. Phase retrieval is a methodology for determining these variations. Phase retrieval uses images taken with the optical system and using a light source of known shape and characteristics. Unlike interferometric methods, which require an optical reference for comparison, and unlike Shack-Hartmann wavefront sensors that require special optical hardware at the optical system's exit pupil, phase retrieval is an in situ, image-based method for determining the phase variations of light at the system s exit pupil. Phase retrieval can be used both as an optical metrology tool (during fabrication of optical surfaces and assembly of optical systems) and as a sensor used in active, closed-loop control of an optical system, to optimize performance. One class of phase-retrieval algorithms is the iterative transform algorithm (ITA). ITAs estimate the phase variations by iteratively enforcing known constraints in the exit pupil and at the detector, determined from modeled or measured data. The Variable Sampling Mapping (VSM) technique is a new method for enforcing these constraints in ITAs. VSM is an open framework for addressing a wide range of issues that have previously been considered detrimental to high-accuracy phase retrieval, including undersampled images, broadband illumination, images taken at or near best focus, chromatic aberrations, jitter or vibration of the optical system or detector, and dead or noisy detector pixels. The VSM is a model-to-data mapping procedure. In VSM, fully sampled electric fields at multiple wavelengths are modeled inside the phase-retrieval algorithm, and then these fields are mapped to intensities on the light detector, using the properties of the detector and optical system, for comparison with measured data. Ultimately, this model-to-data mapping procedure enables a more robust and accurate way of incorporating the exit-pupil and image detector constraints, which are fundamental to the general class of ITA phase retrieval algorithms.

Smith, Jeffrey, S.↗

The ProtoDUNE large demonstrator of the Liquid Argon double phase TPC program at CERN

The Deep Underground Neutrino Experiment (DUNE) will use a large liquid argon detector consisting of four modules each with a fiducial mass of 10 kt. A liquid-argon TPC working in double phase mode has been proposed as one of the first modules. The protoDUNE DP is a large demonstrator of the double phase liquid argon TPC with a 6×6×6 m(3) (300t) active volume. ProtoDUNE DP is under construction at CERN and will be exposed to a charged particle beam (0.5-20 GeV/c) in 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evolution of the Data Quality Monitoring and Prompt Processing System in the proto DUNE-SP experiment

The DUNE Collaboration currently operates an experimental program based at CERN which includes a beam test and an extended cosmic ray run of two large-scale prototypes of the massive Liquid Argon Time Projection Chamber (LArTPC) for the DUNE Far Detector. The volume of data collected by the single-phase prototype (protoDUNE-SP) amounts to 3PB and the sustained rate of data sent to mass storage is O(100) MB/s. Data Quality Monitoring was implemented by directing a fraction of the data stream to the protoDUNE prompt processing system (p3s) which is optimized for continuous low-latency calculation of the vital detector metrics and various graphics including event displays. It served a crucial role throughout the life cycle of the experiment. We present our experience in leveraging the CERN computing environment and operating the system over an extended period of time, while adapting to evolving requirements and computing platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polycapillary lenses for soft x-ray transmission in ITER: Model, comparison with experiments, and potential application

Measuring Soft X-Ray (SXR) radiation [0.1 keV; 15 keV] in tokamaks is a standard way of extracting valuable information on the particle transport and magnetohydrodynamic activity. Generally, the analysis is performed with detectors positioned close to the plasma for a direct line of sight. A burning plasma, like the ITER deuterium-tritium phase, is too harsh an environment to permit the use of such detectors in close vicinity of the machine. We have thus investigated in this article the possibility of using polycapillary lenses in ITER to transport the SXR information several meters away from the plasma in the complex port-plug geometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pursuing the Ultimate Power of Xenon Dark Matter Detectors (Annual Progress Report)

Liquid xenon-based experiments have been leading direct searches for dark matter – a cornerstone of modern cosmology and particle physics. Despite rapid improvement of experimental sensitivities in the past two decades, no definitive dark matter interactions have been observed. This project aims to expand the physics reach of existing and future xenon dark matter experiments, especially for low-mass dark matter interactions that would fall below the energy thresholds of current detectors. The main approach is to thoroughly characterize and to suppress the low-energy electron background observed in dual-phase xenon Time Projection Chambers (TPCs), which has so far prevented these detectors from achieving lower energy thresholds. Per recent discussion with and approval from the program manager, we have added a new task of experimentally measuring the Migdal effect to this project. The Migdal effect predicts that ultra-low energy dark matter interactions may produce detectable electron recoil signals in liquid xenon at the keV level in addition to much lower energy nuclear recoils. If this effect is experimentally measured, it will drastically improve xenon detectors’ sensitivity to subGeV dark matter interactions. This new task shares strong synergy with the original project goal of pursuing the ultimate power of xenon dark matter experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Interferometric direction finding with a metamaterial detector

We present measurements and analysis demonstrating useful direction finding of sources in the S band (2–4 GHz) using a metamaterial detector. An augmented metamaterial absorber that supports magnitude and phase measurement of the incident electric field, within each unit cell, is described. The metamaterial is implemented in a commercial printed circuit board process with off-board back-end electronics. We also discuss on-board back-end implementation strategies. Direction finding performance is analyzed for the fabricated metamaterial detector using simulated data and the standard algorithm, MUtiple SIgnal Classification. The performance of this complete system is characterized by its angular resolution as a function of radiation density at the detector. Sources with power outputs typical of mobile communication devices can be resolved at kilometer distances with sub-degree resolution and high frame rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

DarkSide-20k (DS-20k) is a dark matter detection experimentunder construction at the Laboratori Nazionali del Gran Sasso (LNGS)in Italy. It utilises ∼ 100 t of low radioactivity argon from anunderground source (UAr) in its inner detector, with half serving astarget in a dual-phase time projection chamber (TPC). The UArcryogenics system must maintain stable thermodynamic conditionsthroughout the experiment's lifetime of over10 years. Continuous removal ofimpurities and radon from the UAr is essential for maximising signalyield and mitigating background. We are developing an efficient andpowerful cryogenics system with a gas purification loop with atarget circulation rate of1000 slpm. Central to itsdesign is a condenser operated with liquid nitrogen which is pairedwith a gas heat exchanger cascade, delivering a combined coolingpower of more than 8 kW. Here wepresent the design choices in view of the DS-20k requirements, inparticular the condenser's working principle and the coolingcontrol, and we show test results obtained with a dedicatedbenchmarking platform at CERN and LNGS. We find that the thermalefficiency of the recirculation loop, defined in terms of nitrogenconsumption per argon flow rate, is95 % and the pressure in the testcryostat can be maintained within±(0.1–0.2) mbar. Wefurther detail a 5-day cool-down procedure of the test cryostat,maintaining a cooling rate typically within-2 K/h, as required for theDS-20k inner detector. Additionally, we assess the circuit's flowresistance, and the heat transfer capabilities of two heat exchangergeometries for argon phase change, used to provide gas forrecirculation. We conclude by discussing how our findings influencethe finalisation of the system design, including necessarymodifications to meet requirements and ongoing testing activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser Metrology Heterodyne Phase-Locked Loop

A method reduces sensitivity to noise in a signal from a laser heterodyne interferometer. The phase-locked loop (PLL) removes glitches that occur in a zero-crossing detector s output [that can happen if the signal-to-noise ratio (SNR) of the heterodyne signal is low] by the use of an internal oscillator that produces a square-wave signal at a frequency that is inherently close to the heterodyne frequency. It also contains phase-locking circuits that lock the phase of the oscillator to the output of the zero-crossing detector. Because the PLL output is an oscillator signal, it is glitch-free. This enables the ability to make accurate phase measurements in spite of low SNR, creates an immunity to phase error caused by shifts in the heterodyne frequency (i.e. if the target moves causing Doppler shift), and maintains a valid phase even when the signal drops out for brief periods of time, such as when the laser is blocked by a stray object.

Loya, Frank↗

SU-E-T-59: Calculations of Collimator Scatter Factors (Sc) with and Without Custom-Made Build-Up Caps for CyberKnife

Purpose: To investigate the impact of custom-made build-up caps for a diode detector in robotic radiosurgery radiation fields with variable collimator (IRIS) for collimator scatter factor (Sc) calculation. Methods: An acrylic cap was custom-made to fit our SFD (IBA Dosimetry, Germany) diode detector. The cap has thickness of 5 cm, corresponding to a depth beyond electron contamination. IAEA phase space data was used for beam modeling and DOSRZnrc code was used to model the detector. The detector was positioned at 80 cm source-to-detector distance. Calculations were performed with the SFD, with and without the build-up cap, for clinical IRIS settings ranging from 7.5 to 60 mm. Results: The collimator scatter factors were calculated with and without 5 cm build-up cap. They were agreed within 3% difference except 15 mm cone. The Sc factor for 15 mm cone without buildup was 13.2% lower than that with buildup. Conclusion: Sc data is a critical component in advanced algorithms for treatment planning in order to calculate the dose accurately. After incorporating build-up cap, we discovered differences of up to 13.2 % in Sc factors in the SFD detector, when compared against in-air measurements without build-up caps.

07 ISOTOPE AND RADIATION SOURCES↗

SCGSR Final Report

Dual phase noble liquid time projection chambers (TPCs) have an unprecedented sensitivity towards dark matter searches and neutrinos, owing to their ability to detect single electrons. When a particle deposits energy into one of these detectors, electrons are released and drifted into a gaseous region of high electric field. In the gas, the electrons are accelerated to produce extra light into what is called an S2 pulse. This light is far easier to detect than the current induced from a single electron. The two widely used elements for noble liquid detectors are Xe and Ar. Xe has a larger chance of being hit by neutrinos or dark matter, but ends with a lower (i.e. harder to detect) energy when struck. However, Ar light is hard to reflect and detect due to its short wavelength which is absorbed by most materials. While one may use TPB to re-emit this light at a longer wavelength, spatial variations of TPB thickness can smear the amount of re-emitted light, and thus cause a poor S2 energy resolution and spatial resolution. Furthermore, a single electron pulse in Ar is spread over a much longer time than one in Xe, which makes it harder to identify single electrons in Ar. The goal of Xe doping is to combine the best aspects of Ar with the best aspects of Xe. More specifically, this means a detector with a larger yield of photons and electrons produced per energy deposition, an ability to collect more of the light given by those signals, and a narrower pulse from the electron signal. During this project, we developed and operated a detector that can overcome the thermodynamic challenges of Xe doping – namely, preventing Xe from freezing. In the first experimental run during this award period, we found that we can achieve at least 5% of Xe in LAr, and measure the Xe concentration in the gas. In the second run, we installed our detector and saw the first S2 pulses in a dual phase Xe doped LAr TPC. With the data we took, we quantified the effect of Xe doping on the detectability of wavelength-shifted light produced in a Xe doped Ar mixture, as well as the single electron pulse shape. While the Ar light has successfully been wavelength shifted, we learned that much to our surprise, Xe doping actually makes the S2 pulse wider before it makes it narrower.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Approaching perfect microwave photodetection in circuit QED

In order to apply all ideas from quantum optics to the field of quantum circuits, one of the missing ingredients is a high-efficiency single-photon detector. In this work we propose a design for such a device which successfully reaches 100% efficiency with only one absorber. Our photon detector consists of a three-level system (a phase qubit) coupled to a semi-infinite one-dimensional waveguide (a microwave transmission line) which performs highly efficient photodetection in a simplified manner as compared to previous proposals. Using the tools of quantum optics we extensively study the scattering properties of realistic wave packets against this device, thereby computing the efficiency of the detector. We find that the detector has many operating modes, can detect detuned photons, is robust against design imperfections, and can be made broadband by using more than one absorbing element in the design. Many of these ideas could be translated to other single-mode photonic or plasmonic waveguides interacting with three-level atoms or quantum dots.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modified gravitational wave propagation with higher modes and its degeneracies with lensing

Low-energy alternatives to General Relativity (GR) generically modify the phase of gravitational waves (GWs) during their propagation. As detector sensitivities increase, it becomes key to understand how these modifications affect the GW higher modes and to disentangle possible degeneracies with astrophysical phenomena. We apply a general formalism — the WKB approach — for solving analytically wave propagation in the spatial domain with a modified dispersion relation (MDR). We compare this WKB approach to applying a stationary phase approximation (SPA) in the temporal domain with time delays associated to the group or particle velocity. To this end, we extend the SPA to generic signals with higher modes, keeping careful track of reference phases and arrival times. We find that the WKB approach coincides with the SPA using the group velocity, in agreement with the principles of wave propagation. We then explore the degeneracies between a GW propagation with an MDR and a strongly-lensed GW in GR, since the latter can introduce a frequency-independent phase shift which is not degenerate with source parameters in the presence of higher modes. We find that for a particular MDR there is an exact degeneracy for wave propagation, unlike with the SPA for particle propagation. For the other cases, we search for the values of the MDR parameters that minimize the χ 2 and conclude that strongly-lensed GR GWs could be misinterpreted as GWs in modified gravity. As a result, future MDR constraints with higher mode GWs should include the possibility of frequency-independent phase shifts, allowing for the identification of modified gravity and strong lensing distortions at the same time.

79 ASTRONOMY AND ASTROPHYSICS↗

Acquisition of the QPSK demodulator in the presence of interference

The acquisition behavior of the tracking and data relay satellite system (TDRSS) receiver (a quadrative phase-shift keying (QPSK) demodulator using a dither lock detector) in the presence of interference from another user has been analyzed using a simulation model. The demodulator is composed of an automatic gain control, a QPSK Costas loop, a frequency sweep unit, lock test units, and a control unit. The simulation model has been tested for the following variables: signal and interference Doppler frequencies and phase offsets (with respect to initial voltage control oscillator setup), signal-to-interference ratio (SIR), and signal I/Q power ratio. The simulation results are discussed.

Ghazvinian, Farzad↗

All electrical propagating spin wave spectroscopy with broadband wavevector capability

We developed an all electrical experiment to perform the broadband phase-resolved spectroscopy of propagating spin waves in micrometer sized thin magnetic stripes. The magnetostatic surface spin waves are excited and detected by scaled down to 125 nm wide inductive antennas, which award ultra broadband wavevector capability. The wavevector selection can be done by applying an excitation frequency above the ferromagnetic resonance. Wavevector demultiplexing is done at the spin wave detector thanks to the rotation of the spin wave phase upon propagation. A simple model accounts for the main features of the apparatus transfer functions. Our approach opens an avenue for the all electrical study of wavevector-dependent spin wave properties including dispersion spectra or non-reciprocal propagation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Revealing Phase Heterogeneity in Vertically Aligned Nanocomposites via Plan-View Electron Energy Loss Spectroscopy

Hydrogen utilization in clean energy technologies is challenged by limited storage and transport within materials, owing to the complex hydrogen kinetics at interfaces [1]. Understanding these interfacial mechanisms at the nanoscale is crucial for developing improved materials for hydrogen applications, particularly proton-conducting fuel cells (PCFCs). Vertically aligned nanocomposites (VANs) grown by pulsed laser deposition (PLD) offer a unique platform for investigating the interfacial effects on hydrogen transport due to their well-defined interfaces parallel to the direction of charge transport [2-4]. To investigate hydrogen transport, the two phases within the VANs were chosen as BaZr 0.9 Y 0.1 O 3-x (BZY), a known proton conductor, and Pr 0.1 Ce 0.9 O 2-x (PCO), a mixed ionic-electronic conductor [5]. This PCO-BZY VANs architecture allows the investigation of how the interface between a proton conductor and a mixed conductor influences hydrogen transport. However, because of the small size of hydrogen, it is difficult to discern the nature of its interactions with interfaces from bulk measurements at the macroscale, thus necessitating nanoscale measurements [6]. Electron energy loss spectroscopy (EELS) allows for nanometer-resolution probing of the local atomic structure and chemistry at the BZY/PCO interface. In this study, plan-view analysis of PCO-BZY VANs films was employed to characterize the structure and phase distribution of the VANs and investigate the interface between the nanostructures. The films were imaged using scanning electron microscopy (SEM) in the Hitachi S-4800 SEM, collecting secondary electron images using mixed upper and lower detectors. Then, plan-view transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) EELS were employed using a JEOL ARM300 microscope operated at 300kV with a Gatan K3 GIF Continuum detector to study the distribution of the BZY and PCO phases through the film. As a result, spectrum images were acquired at a dispersion of 0.18eV per channel and denoised afterward by principal component analysis (PCA) method.

Griffin, Elizabeth [Northwestern University, Evans↗