Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PATIENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Evaluation of intracoronary hemodynamics identifies perturbations in vorticity

Coronary artery disease (CAD) is highly prevalent and associated with adverse events. Challenges have emerged in the treatment of intermediate coronary artery stenoses. These lesions are often interrogated with fractional flow reserve (FFR) testing to determine if a stenosis is likely to be causative for ischemia in a cardiac territory. This invasive test requires insertion of a pressure wire into a coronary vessel. Recently computational fluid dynamics (CFD) has been used to noninvasively assess fractional flow reserve in vessels reconstructed from medical imaging data. However, many of these simulations are unable to provide additional information about intravascular hemodynamics, including velocity, endothelial shear stress (ESS), and vorticity. We hypothesized that vorticity, which has demonstrated utility in the assessment of ventricular and aortic diseases, would also be an important hemodynamic factor in CAD. Three-dimensional (3D), patient-specific coronary artery geometries that included all vessels >1 mm in diameter were created from angiography data obtained from 10 patients who underwent diagnostic angiography and FFR testing (n = 9). A massively parallel CFD solver (HARVEY) was used to calculate coronary hemodynamic parameters including pressure, velocity, ESS, and vorticity. These simulations were validated by comparing velocity flow fields from simulation to both velocities derived from in vitro particle image velocimetry and to invasively acquired pressure wire-based data from clinical testing. There was strong agreement between findings from CFD simulations and particle image velocimetry experimental testing (p < 0.01). CFD-FFR was also highly correlated with invasively measured FFR (ρ = 0.77, p = 0.01) with an average error of 5.9 ± 0.1%. CFD-FFR also had a strong inverse correlation with the vorticity (ρ = -0.86, p = 0.001). Simulations to determine the effect of the coronary stenosis on intravascular hemodynamics demonstrated significant differences in velocity and vorticity (both p < 0.05). Further evaluation of an angiographically normal appearing non-FFR coronary vessel in patients with CAD also demonstrated differences in vorticity when compared with FFR vessels (p < 0.05). The use of highly accurate 3D CFD-derived intravascular hemodynamics provides additional information beyond pressure measurements that can be used to calculate FFR. Vorticity is one parameter that is modified by a coronary stenosis and appears to be abnormal in angiographically normal vessels in patients with CAD, highlighting a possible use-case in preventative screening for early coronary disease.

59 BASIC BIOLOGICAL SCIENCES↗

Comparative Uptake Patterns of Radioactive Iodine and [18F]-Fluorodeoxyglucose (FDG) in Metastatic Differentiated Thyroid Cancers

Background: Metastatic differentiated thyroid cancer (DTC) represents a molecularly heterogeneous group of cancers with varying radioactive iodine (RAI) and [ 18 F]-fluorodeoxyglucose (FDG) uptake patterns potentially correlated with the degree of de-differentiation through the so-called “flip-flop” phenomenon. However, it is unknown if RAI and FDG uptake patterns correlate with molecular status or metastatic site. Materials and Methods: A retrospective analysis of metastatic DTC patients (n = 46) with radioactive 131-iodine whole body scan (WBS) and FDG-PET imaging between 2008 and 2022 was performed. The inclusion criteria included accessible FDG-PET and WBS studies within 1 year of each other. Studies were interpreted by two blinded radiologists for iodine or FDG uptake in extrathyroidal sites including lungs, lymph nodes, and bone. Cases were stratified by BRAF V600E mutation status, histology, and a combination of tumor genotype and histology. The data were analyzed by McNemar’s Chi-square test. Results: Lung metastasis FDG uptake was significantly more common than iodine uptake (WBS: 52%, FDG: 84%, p = 0.04), but no significant differences were found for lymph or bone metastases. Lung metastasis FDG uptake was significantly more prevalent in the papillary pattern sub-cohort (WBS: 37%, FDG: 89%, p = 0.02) than the follicular pattern sub-cohort (WBS: 75%, FDG: 75%, p = 1.00). Similarly, BRAF V600E+ tumors with lung metastases also demonstrated a preponderance of FDG uptake (WBS: 29%, FDG: 93%, p = 0.02) than BRAF V600E- tumors (WBS: 83%, FDG: 83%, p = 1.00) with lung metastases. Papillary histology featured higher FDG uptake in lung metastasis (WBS: 39%, FDG: 89%, p = 0.03) compared with follicular histology (WBS: 69%, FDG: 77%, p = 1.00). Patients with papillary pattern disease, BRAF V600E+ mutation, or papillary histology had reduced agreement between both modalities in uptake at all metastatic sites compared with those with follicular pattern disease, BRAF V600E- mutation, or follicular histology. Low agreement in lymph node uptake was observed in all patients irrespective of molecular status or histology. Conclusions: The pattern of FDG-PET and radioiodine uptake is dependent on molecular status and metastatic site, with those with papillary histology or BRAF V600E+ mutation featuring increased FDG uptake in distant metastasis. Further study with an expanded cohort may identify which patients may benefit from specific imaging modalities to recognize and surveil metastases.

60 APPLIED LIFE SCIENCES↗

Screening and Brief Interventions for Alcohol Use During Pregnancy: Practices Among US Primary Care Clinicians, DocStyles 2019

Alcohol use during pregnancy can cause birth defects and developmental disabilities. From 2018 through 2020, 13.5% of pregnant women reported current drinking. The US Preventive Services Task Force recommends evidence-based tools (eg, AUDIT-C and SASQ) for implementing screening and brief interventions to reduce excessive alcohol use among adults, including pregnant people, for whom any alcohol use is considered excessive. We used DocStyles 2019 data to conduct a cross-sectional analysis to examine current screening and brief intervention practices that primary care clinicians conduct among pregnant patients; clinicians’ confidence levels in conducting screening, brief interventions, and referral to treatment; and the documentation of brief interventions in the medical record. A total of 1,500 US adult medicine clinicians completed the entire survey. Among the respondents who conduct screening (N = 1,373) and brief interventions (N = 1,357) in their practice, nearly all reported implementing screening (94.6%) and brief interventions (94.9%) with their pregnant patients for alcohol use, but fewer than half felt confident about conducting their screening practices (46.5%). Two-thirds (64%) reported using a tool that met the criteria recommended by the US Preventive Services Task Force (USPSTF). Over half documented brief interventions in electronic health record notes (51.7%) or designated space (50.7%). Pregnancy presents a unique opportunity for clinicians to incorporate screening into routine obstetric care and encourage behavior change among patients. Most providers reported always screening their pregnant patients for alcohol use, but fewer used evidence-based USPSTF-recommended screening tools. Increased clinician confidence in screening and brief intervention, the use of standardized screening tools tailored to pregnant people, and maximal use of electronic health record technology may enhance the benefits of their application to alcohol use, which ultimately can reduce adverse outcomes associated with alcohol use during pregnancy.

60 APPLIED LIFE SCIENCES↗

SARS-CoV-2 suppresses anticoagulant and fibrinolytic gene expression in the lung

Extensive fibrin deposition in the lungs and altered levels of circulating blood coagulation proteins in COVID-19 patients imply local derangement of pathways that limit fibrin formation and/or promote its clearance. We examined transcriptional profiles of bronchoalveolar lavage fluid (BALF) samples to identify molecular mechanisms underlying these coagulopathies. mRNA levels for regulators of the kallikrein–kinin (C1-inhibitor), coagulation (thrombomodulin, endothelial protein C receptor), and fibrinolytic (urokinase and urokinase receptor) pathways were significantly reduced in COVID-19 patients. While transcripts for several coagulation proteins were increased, those encoding tissue factor, the protein that initiates coagulation and whose expression is frequently increased in inflammatory disorders, were not increased in BALF from COVID-19 patients. Our analysis implicates enhanced propagation of coagulation and decreased fibrinolysis as drivers of the coagulopathy in the lungs of COVID-19 patients.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of the pulse-contour method of determining stroke volume in man.

The pulse-contour method for determining stroke volume has been employed as a continuous rapid method of monitoring the cardiovascular status of patients. Twenty-one patients with ischemic heart disease and 21 patients with mitral valve disease were subjected to a variety of hemodynamic interventions. The pulse-contour estimations, using three different formulas derived by Warner, Kouchoukos, and Herd, were compared with indicator-dilution outputs. A comparison of the results of the two methods for determining stroke volume yielded correlation coefficients ranging from 0.59 to 0.84. The better performing Warner formula yielded a coefficient of variation of about 20%. The type of hemodynamic interventions employed did not significantly affect the results using the pulse-contour method. Although the correlation of the pulse-contour and indicator-dilution stroke volumes is high, the coefficient of variation is such that small changes in stroke volume cannot be accurately assessed by the pulse-contour method. However, the simplicity and rapidity of this method compared to determination of cardiac output by Fick or indicator-dilution methods makes it a potentially useful adjunct for monitoring critically ill patients.

Alderman, E. L.↗

Preliminary report on use of Lahey clinic automated history in an idustrial complex

A questionnaire has been developed and used extensively as an aid to the appointment office in determining what department a patient should be referred to and what time for special consultations should be reserved. It has helped to maintain a balanced case load and informs the physician in advance about the patients he will see. By coordinating appointments so that the patient can visit two or more of the specialty departments in one day rather than having to return a number of times to see different doctors, it has increased efficiency. The questionnaire screens for important symptoms or trouble spots to which the computer is programmed to assign scoring values which in turn point out the clinic division or section to which the patient should initially be referred.

Leonardson, B. O.↗

Development of the NASA/Baylor VAD

A cooperative effort between the NASA/Johnson Space Center (JSC) and the Baylor College of Medicine (BCM) has been underway since 1988 to develop a long-term implantable Ventricular Assist Device (VAD). The VAD is intended to boost the cardiac output of patients with deteriorated cardiac function. For many of these patients, the best alternative is heart transplantation. Heart transplantation is a complex and expensive procedure and usually requires a long waiting period for a donor heart. The condition of the patient often deteriorates during this waiting period which complicates the pre and post-operative care. Because of these factors, the need for a long-term implantable VAD for use as a bridge-to-transplant device or as a permanent assist device has become the focus of much research. The need for a VAD has been estimated at 50,000 to 60,000 patients per year in the United States alone. A device which satisfies all the system performance and reliability requirements has yet to be achieved. However, the development of the NASA/Baylor VAD has progressed to a state in which commercial viability can being to be considered. The device is small, simple, efficient and reliable which meets all requirements for a totally implantable VAD.

Aber, G. S.↗

Multimodal correlation and intraoperative matching of virtual models in neurosurgery

The multimodal correlation between different diagnostic exams, the intraoperative calibration of pointing tools and the correlation of the patient's virtual models with the patient himself, are some examples, taken from the biomedical field, of a unique problem: determine the relationship linking representation of the same object in different reference frames. Several methods have been developed in order to determine this relationship, among them, the surface matching method is one that gives the patient minimum discomfort and the errors occurring are compatible with the required precision. The surface matching method has been successfully applied to the multimodal correlation of diagnostic exams such as CT, MR, PET and SPECT. Algorithms for automatic segmentation of diagnostic images have been developed to extract the reference surfaces from the diagnostic exams, whereas the surface of the patient's skull has been monitored, in our approach, by means of a laser sensor mounted on the end effector of an industrial robot. An integrated system for virtual planning and real time execution of surgical procedures has been realized.

Ceresole, Enrico↗

Delivery of cardiopulmonary resuscitation in the microgravity environment

The microgravity environment presents several challenges for delivering effective cardiopulmonary resuscitation (CPR). Chest compressions must be driven by muscular force rather than by the weight of the rescuer's upper torso. Airway stabilization is influenced by the neutral body posture. Rescuers will consist of crew members of varying sizes and degrees of physical deconditioning from space flight. Several methods of CPR designed to accommodate these factors were tested in the one G environment, in parabolic flight, and on a recent shuttle flight. Methods: Utilizing study participants of varying sizes, different techniques of CPR delivery were evaluated using a recording CPR manikin to assess adequacy of compressive force and frequency. Under conditions of parabolic flight, methods tested included conventional positioning of rescuer and victim, free floating 'Heimlich type' compressions, straddling the patient with active and passive restraints, and utilizing a mechanical cardiac compression assist device (CCAD). Multiple restrain systems and ventilation methods were also assessed. Results: Delivery of effective CPR was possible in all configurations tested. Reliance on muscular force alone was quickly fatiguing to the rescuer. Effectiveness of CPR was dependent on technique, adequate restraint of the rescuer and patient, and rescuer size and preference. Free floating CPR was adequate but rapidly fatiguing. The CCAD was able to provide adequate compressive force but positioning was problematic. Conclusions: Delivery of effective CPR in microgravity will be dependent on adequate resuer and patient restraint, technique, and rescuer size and preference. Free floating CPR may be employed as a stop gap method until patient restraint is available. Development of an adequate CCAD would be desirable to compensate for the effects of deconditioning.

Barratt, M. R.↗

Method and apparatus for non-invasive evaluation of diaphragmatic function

A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.

Yost, William T.↗

Method and apparatus for non-invasive evaluation of diaphragmatic function

A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.

Yost, William T.↗

Information Technology: A Tool to Cut Health Care Costs

Old Dominion University embarked on a project to see how current computer technology could be applied to reduce the cost and or to improve the efficiency of health care services. We designed and built a prototype for an integrated medical record system (MRS). The MRS is written in Tool control language/Tool kit (Tcl/Tk). While the initial version of the prototype had patient information hard coded into the system, later versions used an INGRES database for storing patient information. Currently, we have proposed an object-oriented model for implementing MRS. These projects involve developing information systems for physicians and medical researchers to enhance their ability for improved treatment at reduced costs. The move to computerized patient records is well underway, several standards exist for laboratory records, and several groups are working on standards for other portions of the patient record.

Mukkamala, Ravi↗

Abnormal Eye Movements in Creutzfeldt-Jakob Disease

We report 3 patients with autopsy-proven Creutzfeldt-Jakob disease who, early in their course, developed abnormal eye movements that included periodic alternating nystagmus and slow vertical saccades. These findings suggested involvement of the cerebellar nodulus and uvula, and the brainstem reticular formation, respectively. Cerebellar ataxia was also an early manifestation and, in one patient, a frontal lobe brain biopsy was normal at a time when ocular motor and cerebellar signs were conspicuous. As the disease progressed, all saccades and quick phases of nystagmus were lost, but periodic alternating gaze deviation persisted. At autopsy, 2 of the 3 patients had pronounced involvement of the cerebellum, especially of the midline structures. Creutzfeldt-Jakob disease should be considered in patients with subacute progressive neurological disease when cognitive changes are overshadowed by ocular motor findings or ataxia.

Grant, Michael P.↗

NASA Technology Benefits Orthotics

Engineers at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama have designed a knee brace to aid in the rehabilitation of medical patients. The device, called the Selectively Lockable Knee Brace, was designed for knee injury and stroke patients but may potentially serve in many more patient applications. Individuals with sports related injuries, spinal cord injuries and birth defects, such as spina bifida, may also benefit from the device. The Selectively Lockable Knee Brace is designed to provide secure support to the patient when weight is applied to the leg; however; when the leg is not supporting weight, the device allows free motion of the knee joint. Braces currently on the market lock the knee in a rigid, straight or bent position, or by manually pulling a pin, allow continuous free joint motion.

Myers, Neill↗

Biomedical Use of Aerospace Personal Cooling Garments

Personal thermoregulatory systems are required during extravehicular activity (EVA) to remove the metabolic heat generated by the suited astronaut. The Extravehicular and Protective Systems (STE) Branch of NASA Ames Research Center has developed advanced concepts or liquid cooling garments for both industrial and biomedical applications for the past 25 years. Examples of this work include: (1) liquid cooled helmets for helicopter pilots and race car drivers; (2) vests for fire and mine rescue personnel; (3) bras to increase the definition of tumors during thermography; (4) lower body garments for young women with erythomelaigia; and (5) whole body garments used by patients with multiple sclerosis (MS). The benefits of the biomedical application of artificial thermoregulation received national attention through two recent events: (1) the liquid-cooled garment technology was inducted into the United States Space Foundation's Space Technology Hall of Fame (1993); and (2) NASA has signed a joint Memorandum of Understanding with the Multiple Sclerosis Association (1994) to share this technology for use with MS patient treatment. The STE Branch is currently pursuing a program to refine thermoregulatory design in light of recent technology developments that might be applicable for use by several medical patient populations. Projects have been initiated to apply thermoregulatory technology for the treatment and/or rehabilitation of patients with spinal cord injuries, multiple sclerosis, migraine headaches, and to help prevent the loss of hair during chemotherapy.

Webbon, Bruce W.↗

Method and Apparatus for Assessment of Changes in Intracranial Pressure

A non-invasive method and apparatus for monitoring changes in intracranial pressure which removes extracranial effects from the measurements. The method and apparatus can include the supplying of a fixed frequency electrical output to a transducer coupled to the patient's head, thereby generating an acoustical tone burst in the patient's head which generates a first echo and a second echo, the first echo reflecting from a first interface in the side of the patient's head coupled to the transducer, and the second echo reflecting from a second interface at the opposite side of the patient's head. The first and second echoes are received by the transducer which can generate a first electrical signal and a second electrical signal, wherein the first and second electrical signals vary in accordance with the corresponding first and second echoes. The counterbalancing phase shifts required to bring about quadrature between each of the first and second electrical signals and the fixed frequency electrical output can be measured, and values for the change in intracranial distance based on the changes in the counterbalancing phase shifts can be obtained.

Yost, William T.↗

Keeping Hearts Pumping

A collaboration between NASA, Dr. Michael DeBakey, Dr. George Noon, and MicroMed Technology, Inc., resulted in a life-saving heart pump for patients awaiting heart transplants. The MicroMed DeBakey VAD functions as a "bridge to heart transplant" by pumping blood throughout the body to keep critically ill patients alive until a donor heart is available. Weighing less than 4 ounces and measuring 1 inch by 3 inches, the pump is approximately one-tenth the size of other currently marketed pulsatile VADs. This makes it less invasive and ideal for smaller adults and children. Because of the pump's small size, less than 5 percent of the patients implanted developed device-related infections. It can operate up to 8 hours on batteries, giving patients the mobility to do normal, everyday activities.The MicroMed DeBakey VAD is a registered trademark of MicroMed Technology, Inc.

Source record↗

Radiation-induced second cancers: the impact of 3D-CRT and IMRT

Information concerning radiation-induced malignancies comes from the A-bomb survivors and from medically exposed individuals, including second cancers in radiation therapy patients. The A-bomb survivors show an excess incidence of carcinomas in tissues such as the gastrointestinal tract, breast, thyroid, and bladder, which is linear with dose up to about 2.5 Sv. There is great uncertainty concerning the dose-response relationship for radiation-induced carcinogenesis at higher doses. Some animal and human data suggest a decrease at higher doses, usually attributed to cell killing; other data suggest a plateau in dose. Radiotherapy patients also show an excess incidence of carcinomas, often in sites remote from the treatment fields; in addition there is an excess incidence of sarcomas in the heavily irradiated in-field tissues. The transition from conventional radiotherapy to three-dimensional conformal radiation therapy (3D-CRT) involves a reduction in the volume of normal tissues receiving a high dose, with an increase in dose to the target volume that includes the tumor and a limited amount of normal tissue. One might expect a decrease in the number of sarcomas induced and also (less certain) a small decrease in the number of carcinomas. All around, a good thing. By contrast, the move from 3D-CRT to intensity-modulated radiation therapy (IMRT) involves more fields, and the dose-volume histograms show that, as a consequence, a larger volume of normal tissue is exposed to lower doses. In addition, the number of monitor units is increased by a factor of 2 to 3, increasing the total body exposure, due to leakage radiation. Both factors will tend to increase the risk of second cancers. Altogether, IMRT is likely to almost double the incidence of second malignancies compared with conventional radiotherapy from about 1% to 1.75% for patients surviving 10 years. The numbers may be larger for longer survival (or for younger patients), but the ratio should remain the same.

Review, Tutorial↗