Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ODS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

SU-F-SPS-10: The Dosimetric Comparison of GammaKnife and Cyberknife Treatment Plans for Brain SRS Treatment

Purpose: Brain stereotactic radiosurgery (SRS) involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of GammaKnife perfection and Cyberknife M6 treatment plans were made. Methods: Treatment plannings were done for GammaKnife perfection unit using Gammaplan treatment planning system (TPS) on the CT scan of head and neck randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using TMR 10 algorithm. The treatment planning for the same target were also done for Cyberknife M6 machine using Multiplan (TPS) with Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife treatment plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For gammaknife treatment plans, the gamma analysis passing rates were 98.9% and 93.2% for target and peripheral region of target respectively. Conclusion: The study shows that dosimetrically comparable plans are achievable with Cyberknife and GammaKnife. Although TMR 10 algorithm predicts the target dose.

60 APPLIED LIFE SCIENCES↗

SU-F-SPS-11: The Dosimetric Comparison of Truebeam 2.0 and Cyberknife M6 Treatment Plans for Brain SRS Treatment

Purpose: Brain stereotactic radiosurgery involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of Truebeam 2.0 and Cyberknife M6 treatment plans were made. Methods: For Truebeam 2.0 machine, treatment planning were done using 2 full arc VMAT technique with 6 FFF beam on the CT scan of Randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using Eclipse treatment planning system with Acuros XB algorithm. The treatment planning of the same target were also done for Cyberknife M6 machine with Multiplan treatment planning system using Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For Truebeam plans, the gamma analysis passing rates were 99.1% and 95.5% for target and peripheral region of target respectively. Conclusion: Although, target dose distribution calculated accurately by Acuros XB and Monte Carlo algorithms, Monte carlo calculation algorithm predicts dose distribution around the peripheral region of target more accurately than Acuros algorithm.

60 APPLIED LIFE SCIENCES↗

SU-F-T-52: Study of Energy Dependent Effect of Dosimetry Systems Used in Therapeutic Soft X-Ray Energy Range

Purpose: To investigate energy dependent effects of different dosimetry systems which can be used as in vivo dosimetry monitoring for intraoperative radiotherapy in therapeutic soft x-ray energy range. Methods: Three dosimetry systems were evaluated in therapeutic soft x-ray energy range: optically stimulated luminescent dosimeter (OSLD) nanoDots, radiochromic EBT2 and EBT3 films. The x-ray photons were produced by a Zeiss Intrabeam 50 kV x-ray radiotherapy system. Solid water and bolus slabs with different thicknesses were used in the process of irradiation. An aluminum filter set was used to measure HVLs of X-rays. Calibration curves were made at different depth of boluses. Results: Half Value Layers at depths of 0, 3, 10, and 20 mm of solid water were measured to represent the energy change versus depth, yielding 0.306, 0.482, 0.865 and 0.901 respectively and indicating nearly unchanged HVL beyond 1 cm depth. The responses of each system at different depths were normalized to the response at 2 cm depth. In film dosimetry, the response is calculated as optical density (OD). The results show that there is nearly the same energy dependence for EBT2 and EBT3. At a HVL of 0.482 mm Al, the relative responses of nanoDots and EBT3 are 0.85 ± 0.04 and 0.89 ± 0.03 compared to those at 0.901 mm Al HVL, respectively, indicating no obvious difference between those two systems within the measurement uncertainty. Conclusion: It was observed that the studied dosimeter response increases about 13% from the x-ray energy of 0.48 mm Al to 0.90 mm Al. Therefore, caution should be exercised in using an appropriate calibration curve, and x-ray beam hardening effect has to be taken into account.

60 APPLIED LIFE SCIENCES↗

SU-F-T-566: Absolute Film Dosimetry for Stereotactic Radiosurgery and Stereotactic Body Radiotherapy Quality Assurance Using Gafchromic EBT3 Films

Purpose: To evaluate the dosimetric uncertainty associated with Gafchromic (EBT3) films and establish an absolute dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). Methods: EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields, and standard deviations of dose maps were calculated at each color channel for evaluation. A scanner non-uniform response correction map was built by registering and comparing film doses to the reference diode array-based dose map delivered with the same doses. To determine the temporal dependence of EBT3 films, the average correction factors of different dose levels as a function of time were evaluated up to four days after irradiation. An integrated film dosimetry protocol was developed for dose calibration, calibration curve fitting, dose mapping, and profile/gamma analysis. Patient specific quality assurance (PSQA) was performed for 93 SRS/SBRT treatment plans. Results: The scanner response varied within 1% for the field sizes less than 5 × 5 cm{sup 2}, and up to 5% for the field sizes of 10 × 10 cm{sup 2}. The scanner correction method was able to remove visually evident, irregular detector responses found for larger field sizes. The dose response of the film changed rapidly (∼10%) in the first two hours and plateaued afterwards, ∼3% change between 2 and 24 hours. The mean uncertainties (mean of the standard deviations) were <0.5% over the dose range 1∼15Gy for all color channels for the OD response curves. The percentage of points passing the 3%/1mm gamma criteria based on absolute dose analysis, averaged over all tests, was 95.0 ± 4.2. Conclusion: We have developed an absolute film dose dosimetry protocol using EBT3 films. The overall uncertainty has been established to be approximately 1% for SRS and SBRT PSQA. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗

SU-F-T-665: Confocal Microscopy Imaging of Cell Cycle Distribution in Cells Treated with Pegylated Gold Nanoshells

Purpose: To use confocal microscopy to distinguish cells in different phases of the cell cycle before and after treatment with pegylated gold nanoshells (PEG-AuNSs). Methods: Transfected fibrosarcoma cells (HT1080-EYFP-53BP1-FUCCI) were cultured in T-25 flasks and seeded in glass bottom dishes. These cells express the fluorescent probe AmCyan during the G2/S phases of the cell cycle, mCherry during the G1 phase, and EYFP tagged to the DNA repair protein 53BP1. After allowing cells 4 h to adhere to dishes, PEG-AuNS (Nanospectra Biosciences, Houston, TX) at a concentration of 0.15 OD were administered. At time points of 8, 16 and 24 h following treatment, the PEG-AuNS-treated and control samples were washed with phosphate buffered saline (PBS) and fixed using 4% paraformaldehyde in PBS. Samples were imaged with an Olympus FV1200 confocal microscope using 473, 543, and 641 nm excitation lasers. We used band-pass filters to select AmCyan and mCherry fluorescence. Reflection from the 641 nm laser was used to detect PEG-AuNSs. Z-stack images were analyzed to assess cell cycle distribution through fluorescent probe expression. Live cells were imaged after PEG-AuNS treatment using a confocal microscope with a stage top CO2 incubator. Results: We were able to obtain high-resolution images of cells with internalized AuNSs. We were also able to distinguish cells in different phases of the cell cycle. Conclusion: This work demonstrates a new assay to investigate the effect of AuNSs on the cell cycle phase in live cells. Future work will employ confocal microscopy and flow cytometry to focus on effects of AuNS treatment on cell cycle distribution. This research was supported by the Sister Institution Network Fund and the Center for Radiation Oncology Research at The University of Texas MD Anderson Cancer Center and Cancer Prevention and Research Institute of Texas. Gabriel Sawakuchi has research support from Elekta Inc.

60 APPLIED LIFE SCIENCES↗

New framework hydrous silicate K{sub 3}Sc[Si{sub 3}O{sub 9}] {center_dot} H{sub 2}O related to the high-temperature anhydrous silicate K{sub 3}Ho[Si{sub 3}O{sub 9}] and symmetry analysis of a phase transition with prediction of structures

Crystals of a new framework silicate K{sub 3}Sc[Si{sub 3}O{sub 9}] {center_dot} H{sub 2}O, space group Pm2{sub 1}n (nonstandard setting of space group Pmn2{sub 1} = C{sub 2v}{sup 7}), are obtained under hydrothermal conditions. The structure is determined without preliminary knowledge of the chemical formula. The absolute configuration is determined. The structure is close to that of the high-temperature K{sub 3}Ho[Si{sub 3}O{sub 9}] phase, which was obtained upon the heating of K{sub 3}HoSi{sub 3}O{sub 8}(OH){sub 2}. This structural similarity is due to the specific conditions of synthesis and an analogous formula, where holmium is replaced by scandium. A symmetry analysis shows that the high local symmetry of a block (rod) is responsible for the first-order phase transition of both the order-disorder (OD) and displacement type. The number of structures in which the simplest and high-symmetry layers are multiplied by different symmetry elements are predicted.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mn{sub 0.95}I{sub 0.02}[PO{sub 3}(OH)] · 2H{sub 2}O phosphate–iodate, an inorganic analogue of phosphonates

The new Mn{sub 0.95}I{sub 0.02}[PO{sub 3}(OH)] · 2H{sub 2}O phosphate–iodate (space group Pnam = Pnma, D{sub 2h}{sup 16}) is obtained under hydrothermal conditions. The crystal structure is determined without preliminary knowledge of the chemical formula. The structure consists of layers of MnO{sub 6} octahedra connected with PO{sub 4} tetrahedra. Water molecules are located between the layers. [IO3]{sup –} groups having a typical umbrella-like coordination are statistically implanted in layers of MnO{sub 6} octahedra at a distance of 1.2 Å from Mn atoms. Their content in the crystal is minor. The structures of the phosphate–iodate coincides with the structures of phosphonates with consideration for the replacement of one (OH) vertex of the PO{sub 4} tetrahedron by the organic methyl radical CH{sub 3}. In the structures of phosphonates and earlier studied phosphates, identical layers are distinguished and the cause of the existence of two MDO varieties is established based on the analysis within the OD theory. Possible hybrid structures derived from the prototypes under consideration are predicted.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Capabilities to improve corrosion resistance of fuel claddings by using powerful laser and plasma sources

The treatment conditions of fuel claddings of the E110 alloy by using powerful UV or IR laser radiation, which lead to the increase in the corrosion resistance at the high-temperature (T = 1100°C) oxidation simulating a loss-of-coolant accident, are determined. The possibility of the complete suppression of corrosion under these conditions by using pulsed laser deposition of a Cr layer is demonstrated. The behavior of protective coatings of Al, Al{sub 2}O{sub 3}, and Cr planted on steel EP823 by pulsed laser deposition, which is planned to be used in the BREST-OD-300, is studied. The methods of the almost complete suppression of corrosion in liquid lead to the temperature of 720°C are shown.

36 MATERIALS SCIENCE↗

Top Quark Mass and Properties Measurements with the ATLAS Detector

The top quark is the heaviest elementary particle and unique among the known quarks since it decays before forming hadronic bound states. This makes measurements of the top quark itself particularly interesting as one can access directly the properties of a bare quark. The latest measurements of these properties with the ATLAS detector are reported using data from 8 TeV and 13 TeV proton-proton collisions at the Large Hadron Collider at CERN. The latest measurements of the top quark mass using template meth- ods, as well as others aiming to measure the mass in a well-de ned scheme, are presented. In addition, measurements for the top quark decay width, top quark spin observables and W-boson helicity in events with top quark pairs ($t\bar{t}$) are presented and compared to the Standard Model predictions. The cross-section measurements of top quark pair production in association with a photon, Z- or W-boson are also reported and compared to the most accurate theoretical calculations. These measurements probe the top quark electroweak couplings. Limits on the rate of avour-changing neutral current processes in the production or decay of the top quark are also shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Spatiotemporal Prediction Model for Regional Scheduling of Shared Bicycles Based on the INLA Method

Dock-less bicycle-sharing programs have been widely accepted as an efficient mode to benefit health and reduce congestions. And modeling and prediction has always been a core proposition in the field of transportation. Most of the existing demand prediction models for shared bikes take regions as research objects; therefore, a POI-based method can be a beneficial complement to existing research, including zone-level, OD-level, and station-level techniques. Point of interest (POI) is the location description of spatial entities, which can reflect the cycling route characteristics for both commuting and noncommuting trips to a certain extent, and is also the main generating point and attraction point of shared-bike travel flow. In this study, we make an effort to model a POI-level cycling demand with a Bayesian hierarchical method. The proposed model combines the integrated nested Laplace approximation (INLA) and random partial differential equation (SPDE) to cope with the huge computation in the modeling process. In particular, we have adopted the dock-less bicycle-sharing rental records of Mobike as a case study to validate our method; the study area was one of the fastest growing urban districts in Shanghai in August 2016. The operation results show that the method can help better understand, measure, and characterize spatiotemporal patterns of bike-share ridership at the POI level and quantify the impact of the spatiotemporal effect on bicycle-sharing use.

Yu, Zhuoran↗

Strengths and Limitations of Governmental Support for Environmental Technology in Japan

In recent years, Japanese government and industry have initiated a wide range of policies, programs, and investment strategies responsive to the growing agenda of domestic and global environmental problems. For the most part, these actions have not been due to any significant domestic envi ronmental political pressure but primarily because of the perception that "green" products and manufacturing methods are simply good business. These strategies have, therefore, been closely linked to export and foreign aid policies of long-term benefit to the Japanese economy. A strength of the Japanese approach to environmental policy is the govern ment's ability to bring together a range of business to create a climate for long-term investment in promising new technologies such as fuel cells and electric vehicles. Because this approach is done to advance industrial policy as much as environmental goals, industrial interests are responding to busi ness opportunities, rather than environmental constraints. The Japanese sys tem is, however, not without its own blind spots and limitations. For exam ple, very little has been done to improve the energy efficiency of consumer products, including automobiles, since the mid 1980s. Japanese industry has so far not demonstrated much awareness of concepts like "design for envi ronment" that imply a fundamental reexamination of manufacturing meth ods and materials. The Japanese response to conservation issues that tend not to have technological solutions or potential for business development has also not been as impressive.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Progress Toward Molten Salt Reactor Heat Exchanger On-Line Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Alkaline-SDS cell lysis of microbes with acetone protein precipitation for proteomic sample preparation in 96-well plate format

Plate-based proteomic sample preparation offers a solution to the large sample throughput demands in the biotechnology field where hundreds or thousands of engineered microbes are constructed for testing is routine. Meanwhile, sample preparation methods that work efficiently on broader microbial groups are desirable for new applications of proteomics in other fields, such as microbial communities. Here, we detail a step-by-step protocol that consists of cell lysis in an alkaline chemical buffer (NaOH/SDS) followed by protein precipitation with high-ionic strength acetone in 96-well format. The protocol works for a broad range of microbes ( e . g ., Gram-negative bacteria, Gram-positive bacteria, non-filamentous fungi) and the resulting proteins are ready for tryptic digestion for bottom-up quantitative proteomic analysis without the need for desalting column cleanup. The yield of protein using this protocol increases linearly with respect to the amount of starting biomass from 0.5–2.0 OD*mL of cells. By using a bench-top automated liquid dispenser, a cost-effective and environmentally-friendly option to eliminating pipette tips and reducing reagent waste, the protocol takes approximately 30 minutes to extract protein from 96 samples. Tests on mock mixtures showed expected results that the biomass composition structure is in close agreement with the experimental design. Lastly, we applied the protocol for the composition analysis of a synthetic community of environmental isolates grown on two different media. This protocol has been developed to facilitate rapid, low-variance sample preparation of hundreds of samples and allow flexibility for future protocol development.

59 BASIC BIOLOGICAL SCIENCES↗

Rare Earth Desorption Test with Citrate and Bicarbonate

LBT (lanthanide binding tag) cells were grown overnight in LB media with 0.05% Amp. 1:100 subculture taken from overnights, grown for 2 hours. LBT was induced with 0.002% arabinose added for 3 hours. REE adsorption was done by combining 350 ul (0.25% 1M MES, 12.5 uM Tb, and 12.5 uM La or Cu in sterile DI water) and 350 ul (LBT cells with OD = 1 in 10 mM MES), reacted for approx. 30 min. Following adsorption, citrate and bicarbonate solutions were used in desorption to recover rare earth from cell surface, and to further separate REE from non-REEs. The samples were then centrifuged and a fraction of the supernatant was collected for ICP-MS analysis.

15 GEOTHERMAL ENERGY↗

Hawthorne Nevada Deep Direct-Use Feasibility Study - 3D Seismic

The objective of this project is to use a multi-disciplinary, three-tiered approach to assess the geothermal resource and determine the feasibility of implementing a large-scale, direct-use facility for the Hawthorne Army Depot (HAD) and the various town and county facilities in Hawthorne, Nevada. This assessment directly targets a geothermal resource recently characterized by the Navy Geothermal Program Office (GPO) as part of a focused exploration and development campaign. This data includes but is not limited to: OD Data, Map of Hawthorne Area 3D Seismic Survey, HAW 3D Seismic interpretation report, Zip folder containing DBF files pertaining to the Spring Well Seismic Survey Zone, Zip file containing one shapefile of 3D seismic data.

15 GEOTHERMAL ENERGY↗

Model Inputs, Outputs, and Scripts associated with: “Spatial microbial respiration variations in the hyporheic zones within the Columbia River Basin”

This data package is associated with the publication “Spatial microbial respiration variations in the hyporheic zones within the Columbia River Basin” published in the Journal of Geophysical Research: Biogeosciences (Son et al. 2022) available at doi: 10.1029/2021JG006654. This data package includes the key model inputs/outputs of the river corridor model for the Columbia River Basin (CRB) and the model source codes, which were used in the manuscript. The model is a carbon-nitrogen-coupled river corridor model (RCM), and the model is used to quantify hyporheic zone (HZ) aerobic and anaerobic respiration at the NHDPLUS stream reach scales. The RCM used in this study combines empirical substrate models derived from observations and three microbially driven reactions to compute respiration of the HZ for each National Hydrography Dataset (NHD) reach within the CRB. The reactions in HZs of each NHD reach include anaerobic respiration and two-step anaerobic respiration via denitrification. Our HZ respiration estimates are limited to the lotic (or flowing) stream/river systems, and do not account for the respiration process in water column. Note that the RCM only simulates the HZ’s contribution to the dissolved carbon dioxide (CO2) concentrations in the streams, and the CO2 emissions to the atmosphere are not modelled. The model computes at hourly timesteps because of the fast reaction rates. The key input data of the model are exchange flux, residence time, and stream solute (dissolved organic carbon (DOC), dissolved oxygen (DO), and nitrate concentrations). These inputs are constant over time and represent long-term averaged values.This modeling framework successfully quantified HZ respiration components over multiple scales. It revealed key mechanisms driving the spatial variation of HZ aerobic and anaerobic respiration in reaches with varying hydrologic and substrate conditions. Thus, this modeling study offers a testing hypothesis in different river system (e.g., climate and biomes) for the HZ respiration processes, and can be used as a sampling design tool for large-scale HZ experimental studies.This dataset contains five folders: (1) model_inputs, (2) model_outputs, (3) Rscripts, (4) figures, and (5) model_codes. It also contains a readme, file level metadata (FLMD), and data dictionary (dd). Please see the FLMD for a list of all the files contained in this data package and descriptions for each. The model_inputs folder contains the model inputs used to drive the model simulations. The model_outputs folder contains key model output files from the river corridor model. The Rscripts folder contains the Rscripts for pre- and post- processing model results. The figures folder contains the raw figures associated with the manuscript. The model_codes folder includes key model source codes/input files. All files are .jpg, .jpeg, .out, .e, .od, .dat, .sub, .F90, .0, .R, .sbx, .cpg, .sbn, .shx, .shp, .dbf, .prj, .tfw, .tif, .xml, .pdf, or .csv.

54 ENVIRONMENTAL SCIENCES↗

Model Inputs, Outputs, and Scripts associated with: “Combined effects of stream hydrology and land use on basin-scale hyporheic zone denitrification in the Columbia River Basin”

This data package is associated with the publication “Combined effects of stream hydrology and land use on basin‐scale hyporheic zone denitrification in the Columbia River Basin”, published in Water Resource Research (Son et al.2022) available at https://doi.org/10.1029/2021WR031131. This data package includes the key model inputs/outputs of the river corridor model for the Columbia River Basin (CRB) and the model source codes used in the manuscript. The model is a carbon-nitrogen-coupled river corridor model (RCM), and the model is used to quantify hyporheic zone (HZ) denitrification at the NHDPLUS stream reach scales. The RCM used in this study combines empirical substrate models derived from observations and three microbially driven reactions, including two-step denitrification and aerobic respiration, are considered within the HZ. The key input data of the model are exchange flux, residence time, and stream solute (dissolved organic carbon (DOC), dissolved oxygen (DO), and nitrate concentrations). These inputs are constant over time and represent long-term averaged values. This study uses the RCM to explore the spatial patterns of HZ denitrification across reaches with different sizes and land use in the CRB. Our main objective is to use the RCM as a virtual reality model, and the machine-learning models as surrogates that encapsulate the complexities of the physics-based model while identifying the importance of different variables that are not evident in the model conceptualization. We do not include a direct comparison of the modeled HZ denitrification and measurements; however, the RCM can capture the overall spatial patterns of the HZ denitrification because the model inputs and its reaction networks are based on well-established theory and a physical-based model. The combination of the model-based predictions and a machine-learning approach (e.g., random forest) is used to improve our understanding of what variables of the model are associated with spatial patterns of the modeled denitrification across reaches with different sizes and land uses, and to develop a proxy model using measurable variables to reproduce the simulated patterns.This dataset contains five folders: (1) model_inputs, (2) model_outputs, (3) Rscripts, (4) figures, and (5) model_codes. It also contains a readme, file level metadata (FLMD), and data dictionary (dd). Please see the FLMD for a list of all the files contained in this data package and descriptions for each. The model_inputs folder contains the model inputs used to drive the model simulations. The model_outputs folder contains key model output files from the river corridor model. The Rscripts folder contains the Rscripts for pre- and post- processing model results. The figures folder contains the raw figures associated with the manuscript. The model_codes folder includes key model source codes/input files. All files are .jpg, .jpeg, .out, .e, .od, .dat, .sub, .F90, .0, .R, .sbx, .cpg, .sbn, .shx, .shp, .dbf, .prj, .tfw, .tif, .xml, .pdf, or .csv.

54 ENVIRONMENTAL SCIENCES↗

Application of STEM characterization for investigating radiation effects in BCC Fe-based alloys

This paper provides a general overview of advanced scanning transmission electron microscopy (STEM) techniques used for characterization of irradiated BCC Fe-based alloys. Advanced STEM methods provide the high-resolution imaging and chemical analysis necessary to understand the irradiation response of BCC Fe-based alloys. The use of STEM with energy dispersive x-ray spectroscopy (EDX) for measurement of radiation-induced segregation (RIS) is described, with an illustrated example of RIS in proton- and self-ion irradiated T91. Aberration-corrected STEM-EDX for nanocluster/nanoparticle imaging and chemical analysis is also discussed, and examples are provided from ion-irradiated oxide dispersion strengthened (ODS) alloys. In conclusion, STEM techniques for void, cavity, and dislocation loop imaging are described, with examples from various BCC Fe-based alloys.

36 MATERIALS SCIENCE↗