Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Motion Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

L1599B: CLOUD ENVELOPE AND C{sup +} EMISSION IN A REGION OF MODERATELY ENHANCED RADIATION FIELD

We study the effects of an asymmetric radiation field on the properties of a molecular cloud envelope. We employ observations of carbon monoxide ({sup 12}CO and {sup 13}CO), atomic carbon, ionized carbon, and atomic hydrogen to analyze the chemical and physical properties of the core and envelope of L1599B, a molecular cloud forming a portion of the ring at ≃27 pc from the star Λ Ori. The O8 star provides an asymmetric radiation field that produces a moderate enhancement of the external radiation field. Observations of the [C ii] fine structure line with the GREAT instrument on SOFIA indicate a significant enhanced emission on the side of the cloud facing the star, while the [C i], {sup 12}CO and {sup 13}CO J = 1–0 and 2–1, and {sup 12}CO J = 3–2 data from the Purple Mountain Observatory and APEX telescopes suggest a relatively typical cloud interior. The atomic, ionic, and molecular line centroid velocities track each other very closely, and indicate that the cloud may be undergoing differential radial motion. The H i data from the Arecibo GALFA survey and the SOFIA/GREAT [C ii] data do not suggest any systematic motion of the halo gas, relative to the dense central portion of the cloud traced by {sup 12}CO and {sup 13}CO.

79 ASTRONOMY AND ASTROPHYSICS↗

Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator

Purpose: Intrafraction deformation limits targeting accuracy in radiotherapy. Studies show tumor deformation of over 10 mm for both single tumor deformation and system deformation (due to differential motion between primary tumors and involved lymph nodes). Such deformation cannot be adapted to with current radiotherapy methods. The objective of this study was to develop and experimentally investigate the ability of a dynamic multi-leaf collimator (DMLC) tracking system to account for tumor deformation. Methods: To compensate for tumor deformation, the DMLC tracking strategy is to warp the planned beam aperture directly to conform to the new tumor shape based on real time tumor deformation input. Two deformable phantoms that correspond to a single tumor and a tumor system were developed. The planar deformations derived from the phantom images in beam's eye view were used to guide the aperture warping. An in-house deformable image registration software was developed to automatically trigger the registration once new target image was acquired and send the computed deformation to the DMLC tracking software. Because the registration speed is not fast enough to implement the experiment in real-time manner, the phantom deformation only proceeded to the next position until registration of the current deformation position was completed. The deformation tracking accuracy was evaluated by a geometric target coverage metric defined as the sum of the area incorrectly outside and inside the ideal aperture. The individual contributions from the deformable registration algorithm and the finite leaf width to the tracking uncertainty were analyzed. Clinical proof-of-principle experiment of deformation tracking using previously acquired MR images of a lung cancer patient was implemented to represent the MRI-Linac environment. Intensity-modulated radiation therapy (IMRT) treatment delivered with enabled deformation tracking was simulated and demonstrated. Results: The first experimental investigation of adapting to tumor deformation has been performed using simple deformable phantoms. For the single tumor deformation, the A{sub u}+A{sub o} was reduced over 56% when deformation was larger than 2 mm. Overall, the total improvement was 82%. For the tumor system deformation, the A{sub u}+A{sub o} reductions were all above 75% and the total A{sub u}+A{sub o} improvement was 86%. Similar coverage improvement was also found in simulating deformation tracking during IMRT delivery. The deformable image registration algorithm was identified as the dominant contributor to the tracking error rather than the finite leaf width. The discrepancy between the warped beam shape and the ideal beam shape due to the deformable registration was observed to be partially compensated during leaf fitting due to the finite leaf width. The clinical proof-of-principle experiment demonstrated the feasibility of intrafraction deformable tracking for clinical scenarios. Conclusions: For the first time, we developed and demonstrated an experimental system that is capable of adapting the MLC aperture to account for tumor deformation. This work provides a potentially widely available management method to effectively account for intrafractional tumor deformation. This proof-of-principle study is the first experimental step toward the development of an image-guided radiotherapy system to treat deforming tumors in real-time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cine EPID evaluation of two non-commercial techniques for DIBH

Purpose: To evaluate the efficacy of two noncommercial techniques for deep inspiration breathhold (DIBH) treatment of left-sided breast cancer (LSBC) usingcine electronic portal imaging device (EPID) images. Methods: 23 875 EPID images of 65 patients treated for LSBC at two different cancer treatment centers were retrieved. At the Milford Regional Cancer Center, DIBH stability was maintained by visual alignment of inroom lasers and patient skin tattoos (TAT). At the South Shore Hospital, a distance-measuring laser device (RTSSD) was implemented. For both centers,cine EPID images were acquired at least once per week during beam-on. Chest wall position relative to image boundary was measured and tracked over the course of treatment for every patient and treatment fraction for which data were acquired. Results: Median intrabeam chest motion was 0.31 mm for the TAT method and 0.37 mm for the RTSSD method. The maximum excursions exceeded our treatment protocol threshold of 3 mm in 0.3% of cases (TAT) and 1.2% of cases (RTSSD). The authors did not observe a clinically significant difference between the two datasets. Conclusions: Both noncommercial techniques for monitoring the DIBH location provided DIBH stability within the predetermined treatment protocol parameters (<3 mm). The intreatment imaging offered by the EPID operating incine mode facilitates retrospective analysis and validation of both techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-target camera tracking, hand-off and display LDRD 158819 final report

Modern security control rooms gather video and sensor feeds from tens to hundreds of cameras. Advanced camera analytics can detect motion from individual video streams and convert unexpected motion into alarms, but the interpretation of these alarms depends heavily upon human operators. Unfortunately, these operators can be overwhelmed when a large number of events happen simultaneously, or lulled into complacency due to frequent false alarms. This LDRD project has focused on improving video surveillance-based security systems by changing the fundamental focus from the cameras to the targets being tracked. If properly integrated, more cameras shouldn't lead to more alarms, more monitors, more operators, and increased response latency but instead should lead to better information and more rapid response times. For the course of the LDRD we have been developing algorithms that take live video imagery from multiple video cameras, identifies individual moving targets from the background imagery, and then displays the results in a single 3D interactive video. In this document we summarize the work in developing this multi-camera, multi-target system, including lessons learned, tools developed, technologies explored, and a description of current capability.

47 OTHER INSTRUMENTATION↗

Failure mode and effect analysis-based quality assurance for dynamic MLC tracking systems

Purpose: To develop and implement a failure mode and effect analysis (FMEA)-based commissioning and quality assurance framework for dynamic multileaf collimator (DMLC) tumor tracking systems. Methods: A systematic failure mode and effect analysis was performed for a prototype real-time tumor tracking system that uses implanted electromagnetic transponders for tumor position monitoring and a DMLC for real-time beam adaptation. A detailed process tree of DMLC tracking delivery was created and potential tracking-specific failure modes were identified. For each failure mode, a risk probability number (RPN) was calculated from the product of the probability of occurrence, the severity of effect, and the detectibility of the failure. Based on the insights obtained from the FMEA, commissioning and QA procedures were developed to check (i) the accuracy of coordinate system transformation, (ii) system latency, (iii) spatial and dosimetric delivery accuracy, (iv) delivery efficiency, and (v) accuracy and consistency of system response to error conditions. The frequency of testing for each failure mode was determined from the RPN value. Results: Failures modes with RPN{>=}125 were recommended to be tested monthly. Failure modes with RPN<125 were assigned to be tested during comprehensive evaluations, e.g., during commissioning, annual quality assurance, and after major software/hardware upgrades. System latency was determined to be {approx}193 ms. The system showed consistent and accurate response to erroneous conditions. Tracking accuracy was within 3%-3 mm gamma (100% pass rate) for sinusoidal as well as a wide variety of patient-derived respiratory motions. The total time taken for monthly QA was {approx}35 min, while that taken for comprehensive testing was {approx}3.5 h. Conclusions: FMEA proved to be a powerful and flexible tool to develop and implement a quality management (QM) framework for DMLC tracking. The authors conclude that the use of FMEA-based QM ensures efficient allocation of clinical resources because the most critical failure modes receive the most attention. It is expected that the set of guidelines proposed here will serve as a living document that is updated with the accumulation of progressively more intrainstitutional and interinstitutional experience with DMLC tracking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning-driven descriptions of protein dynamics at solid-liquid interfaces

This chapter has described how ML has enabled quantitative analysis of HS-AFM data to discover the physical phenomena governing protein dynamics and ordering at solid-liquid interfaces. The research detailed in this chapter modeled the rotation models of protein nanorods, the discovery of which would otherwise not be possible. By tracking the trajectories of individual protein rods from frame to frame, it was possible to model Brownian type motion and behaviors and Levy-flight dynamics that had not previously been shown. We also described the application of the Python package AtomAI, which has been developed specifically to analyze and extract physical phenomena, providing exemplar code for training an ensemble of deep neural networks to produce the semantic segmentation of AFM data and functions for encoding and decoding local environments. We last described a combinatorial approach to analyze very noisy data with a densely covered substrate where the emergence of order for the protein liquid crystals could be elucidated. By combining the methods from Case 1 and 2, it was possible to obtain the center of mass and angle for each rod in the images and track the assembly of the rods over time into a 2D liquid crystal array on the surface of mica.

protein dynamics, solid-liquid interfaces, atomic ↗

MO-FG-BRA-08: Swarm Intelligence-Based Personalized Respiratory Gating in Lung SAbR

Purpose: Respiratory gating is widely deployed as a clinical motion-management strategy in lung radiotherapy. In conventional gating, the beam is turned on during a pre-determined phase window; typically, around end-exhalation. In this work, we challenge the notion that end-exhalation is always the optimal gating phase. Specifically, we use a swarm-intelligence-based, inverse planning approach to determine the optimal respiratory phase and MU for each beam with respect to (i) the state of the anatomy at each phase and (ii) the time spent in that state, estimated from long-term monitoring of the patient’s breathing motion. Methods: In a retrospective study of five lung cancer patients, we compared the dosimetric performance of our proposed personalized gating (PG) with that of conventional end-of-exhale gating (CEG) and a previously-developed, fully 4D-optimized plan (combined with MLC tracking delivery). For each patient, respiratory phase probabilities (indicative of the time duration of the phase) were estimated over 2 minutes from lung tumor motion traces recorded previously using the Synchrony system (Accuray Inc.). Based on this information, inverse planning optimization was performed to calculate the optimal respiratory gating phase and MU for each beam. To ensure practical deliverability, each PG beam was constrained to deliver the assigned MU over a time duration comparable to that of CEG delivery. Results: Maximum OAR sparing for the five patients achieved by the PG and the 4D plans compared to CEG plans was: Esophagus Dmax [PG:57%, 4D:37%], Heart Dmax [PG:71%, 4D:87%], Spinal cord Dmax [PG:18%, 4D:68%] and Lung V13 [PG:16%, 4D:31%]. While patients spent the most time in exhalation, the PG-optimization chose end-exhale only for 28% of beams. Conclusion: Our novel gating strategy achieved significant dosimetric improvements over conventional gating, and approached the upper limit represented by fully 4D optimized planning while being significantly simpler and more clinically translatable. This work was partially supported through research funding from National Institutes of Health (R01CA169102) and Varian Medical Systems, Palo Alto, CA, USA.

60 APPLIED LIFE SCIENCES↗

Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to 100%, 99.2%, and 96.5% for the CS, ablation, and lasso catheters, respectively. Subjective clinical evaluation by three experienced electrophysiologists showed that the detection and tracking results were clinically acceptable.Conclusions: The proposed detection and tracking methods are automatic and can detect and track CS, ablation, and lasso catheters simultaneously and in real-time. The accuracy of the proposed methods is sub-mm and the methods are robust toward low-dose x-ray fluoroscopic images, which are mainly used during EP procedures to maintain low radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-Target Camera Tracking, Hand-off and Display LDRD 158819 Final Report

Modern security control rooms gather video and sensor feeds from tens to hundreds of cameras. Advanced camera analytics can detect motion from individual video streams and convert unexpected motion into alarms, but the interpretation of these alarms depends heavily upon human operators. Unfortunately, these operators can be overwhelmed when a large number of events happen simultaneously, or lulled into complacency due to frequent false alarms. This LDRD project has focused on improving video surveillance-based security systems by changing the fundamental focus from the cameras to the targets being tracked. If properly integrated, more cameras shouldn’t lead to more alarms, more monitors, more operators, and increased response latency but instead should lead to better information and more rapid response times. For the course of the LDRD we have been developing algorithms that take live video imagery from multiple video cameras, identify individual moving targets from the background imagery, and then display the results in a single 3D interactive video. In this document we summarize the work in developing this multi-camera, multi-target system, including lessons learned, tools developed, technologies explored, and a description of current capability.

47 OTHER INSTRUMENTATION↗

Multiple target detection in video using quadratic multi-frame correlation filtering

Most integrated target detection and tracking systems employ state-space models to keep track of an explicit number o findividual targets. Recently, a non-state-space framework was developed for enhancing target detection in video by applying probabilistic motion models to the soft information in correlation outputs before thresholding. This framework has been referred to as multi-frame correlation ltering (MFCF), and because it avoids the use of state-space models and the formation of explicit tracks, the framework is well-suited for handling scenes with unknown numbers of targets at unknown positions. In this paper, we propose to use quadratic correlation lters(QCFs)in the MFCF framework for robust target detection. We test our detection algorithm on real and synthe sized single-target and multi-target video sequences. Simulation results show that MFCF can signi cantly reduce (to zero in the best case) the false alarm rates of QCFs at detection rates above 95%in the presence of large amounts of uncorrelated noise. We also show that MFCF is more adept at rejecting those false peaks due to uncorrelated noise rather than those due to clutter and compression noise; consequently, we show that lters used in the framework should be made to favor clutter rejection over noise tolerance.

Kerekes, Ryan A↗

Dark matter directional detection: comparison of the track direction determination

Several directional techniques have been proposed for a directional detection of Dark matter, among others anisotropic crystal detectors, nuclear emulsion plates, and low-pressure gaseous TPCs. The key point is to get access to the initial direction of the nucleus recoiling due to the elastic scattering by a WIMP. In this article, we aim at estimating, for each method, how the information of the recoil track initial direction is preserved in different detector materials. We use the SRIM simulation code to emulate the motion of the first recoiling nucleus in each material. We propose the use of a new observable, D , to quantify the preservation of the initial direction of the recoiling nucleus in the detector. We show that in an emulsion mix and an anisotropic crystal, the initial direction is lost very early, while in a typical TPC gas mix, the direction is well preserved.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy

Purpose: To develop a method for dose reconstruction by incorporating the interplay effect between aperture modulation and target motion, and to assess the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy (VMAT). Methods and Materials: Clinical VMAT plans were delivered with the TrueBeam linac for 8 patients with prostate cancer. The real-time target motion during dose delivery was determined based on the 2-dimensional fiducial localization using an onboard electronic portal imaging device. The target shift in each image was correlated with the control point with the same gantry angle in the VMAT plan. An in-house-developed Monte Carlo simulation tool was used to calculate the 3-dimensional dose distribution for each control point individually, taking into account the corresponding real-time target motion (assuming a nondeformable target with no rotation). The delivered target dose was then estimated by accumulating the dose from all control points in the plan. On the basis of this information, dose–volume histograms and 3-dimensional dose distributions were calculated to assess their degradation from the planned dose caused by target motion. Thirty-two prostate motion trajectories were analyzed. Results: The minimum dose to 0.03 cm{sup 3} of the gross tumor volume (D{sub 0.03cc}) was only slightly degraded after taking motion into account, with a minimum value of 94.1% of the planned dose among all patients and fractions. However, the gross tumor volume receiving prescription dose (V{sub 100%}) could be largely affected by motion, dropping below 60% in 1 trajectory. We did not observe a correlation between motion magnitude and dose degradation. Conclusions: Prostate motion degrades the delivered dose to the target in an unpredictable way, although its effect is reduced over multiple fractions, and for most patients the degradation is small. Patients with greater prostate motion or those treated with stereotactic body radiation therapy would benefit from real-time prostate tracking to reduce the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gel formation and aging in weakly attractive nanocolloid suspensions at intermediate concentrations

We report x-ray photon correlation spectroscopy (XPCS) and rheometry experiments to study the temporal evolution of gel formation and aging in suspensions of silica nanocolloids possessing a tunable short-range attraction. The colloid volume fractions, {phi} = 0.20 and 0.43, are below the glass regime at high concentration and above the fractal regime at low concentration. Following a sudden initiation of the interparticle attraction, the suspensions display a protracted latency period in which they remain fluid before acquiring a measurable elastic shear modulus. The duration of the latency period and the subsequent rate of increase of the modulus vary strongly with the strength of the attraction. The XPCS results indicate dynamic heterogeneity among the colloids during this gel formation in which a growing fraction of the particles become localized. The temporal evolution of this localization correlates with that of the rheology. In particular, the time scale over which the fraction of localized particles increases tracks the duration of the latency period. Also, at {phi} = 0.20 the localization length characterizing the motion of the localized fraction scales onto the shear modulus with no free parameters as predicted by a self-consistent theory based on mode coupling [K. S. Schweizer and G. Yatsenko, J. Chem. Phys. 127, 164505 (2007)10.1063/1.2780861], while deviations from the predicted scaling at {phi} = 0.43 are observed near the gel point. The XPCS results also reveal slow, hyperdiffusive motion of the colloids in the newly formed gels that is attributed to strain from the relaxation of internal stress. While some features of this motion correlate with the evolving rheology, others appear decoupled from the macroscopic mechanical behavior.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inter fractional variability of breathing phase definition as determined by fiducial location

Reconstruction of four-dimensional (4D) imaging typically requires an externally measurable surrogate to represent the real-time relative phase of respiration. A common method is to use a reflective marker on the external surface of the patient which moves with respiration and can be tracked in real time. The location of the marker is often chosen to maximize the observable motion, though this location may not be at the region of interest. We evaluate the importance of infrared (IR) marker placement location on breathing phase definition for the purpose of respiratory gating and 4D computed tomography (CT) image reconstruction. Data were collected for ten patients enrolled on an approved IRB protocol. Real-time position data were collected during CT imaging and daily treatments for two external IR reflective markers: one placed near the xyphoid and another at the approximate location of the treatment isocenter. Motion traces from the markers were compared using cross-correlation coefficient and by estimating the relative respiratory phase, based on either marker, as would be used for 4D-CT reconstruction. Cross-correlation analysis revealed differences in the motion waveform, as well as phase differences, both of which were variable between patients as well as day to day for the same patient. Estimated relative phases from each marker were compared by the percentage amount of time the estimated phase for each marker was different, binned based on increments of 10% of a full cycle. For all collected data combined, the frequency with which breathing phase mismatch led to different bin allocation in steps of 10% was as follows: T{sub 010%}=65.1%, T{sub 1020%}=25.3%, T{sub 2030%}=7.8%, T{sub 3040%}=1.5% and T{sub 4050%}=0.4%. Based on ten images per cycle, this indicates that 4D reconstructions would be influenced, depending on which marker was used, by at least 1 bin 34.9% of the time. This number was noticeably higher for some patients; the maximum was 71% of the time for one patient of ten. In conclusion, the respiratory amplitude and relative phase depend significantly on the location of the IR marker used to monitor respiration. For some patients the xyphoid and isocentric markers may be completely out of phase. More importantly, this relationship varies day to day, suggesting that a single marker may be inadequate for the purposes of respiratory gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Review of Existing Test Methods for Occupancy Sensors

One of the key new features of connected lighting systems (CLS) is their ability to collect data from various types of integral sensors and share that data with other lighting or building systems. Occupancy and vacancy sensors have been widely adopted as an energy-saving strategy in buildings, yet published test methods for reproducibly characterizing their performance remain few and limited in their sophistication. As a result, it has been difficult to predict their performance in a specific application, and in practice, they frequently do not meet energy-savings expectations. Occupants at times remove or otherwise bypass occupancy sensors that hinder their work or otherwise do not perform as expected, thereby compromising the sensors’ potential to reduce energy consumption. Poor performance can result from multiple causes – ranging from fundamental limitations of the sensor technology, to misconfiguration, to poor placement in the room or space. Innovative occupancy sensors, some of them combining multiple sensing technologies, have come on the market over the years, with claims of improved performance compared to their predecessors; yet in practice, their performance has led to neither high deployment nor high user satisfaction in any significant application, nor has it differed enough from the performance of previous products to necessitate a test method that facilitated comparison between them. While the performance of both common and novel occupancy sensors has been the subject of many published research articles, the test methods that have been employed for them have typically been loosely described and incorporated custom equipment or techniques that render them difficult to reproduce, or have been limited in their ability to fairly characterize devices that utilize varying sensor technology. The lack of a well-described, technology-agnostic test method that yields reproducible results across different implementations has been a barrier to the commercial success of new occupancy sensor products, as users and specifiers who have been disappointed with previous products are often unwilling to take a chance with new ones. Motivated by a desire to fairly characterize new technologies that continue to enter the market and claim not only improved occupancy detection but, in some cases, also additional capabilities (e.g., the ability to measure traffic or discern between different object types), this report presents the results of a literature review of recent published, well-described test methods for characterizing occupancy sensor performance, as well as research articles containing ad-hoc test methods. The review also identifies and consolidates the best techniques for characterizing sensor performance in indoor spaces and identifies test method gaps that need to be filled in order to evaluate emerging technologies and products.

47 OTHER INSTRUMENTATION↗

Structure formation by a fifth force: N-body versus linear simulations

We lay out the frameworks to numerically study the structure formation in both linear and nonlinear regimes in general dark-matter-coupled scalar field models, and give an explicit example where the scalar field serves as a dynamical dark energy. Adopting parameters of the scalar field which yield a realistic cosmic microwave background (CMB) spectrum, we generate the initial conditions for our N-body simulations, which follow the spatial distributions of the dark matter and the scalar field by solving their equations of motion using the multilevel adaptive grid technique. We show that the spatial configuration of the scalar field tracks well the voids and clusters of dark matter. Indeed, the propagation of scalar degree of freedom effectively acts as a fifth force on dark matter particles, whose range and magnitude are determined by the two model parameters ({mu},{gamma}), local dark matter density as well as the background value for the scalar field. The model behaves like the {lambda}CDM paradigm on scales relevant to the CMB spectrum, which are well beyond the probe of the local fifth force and thus not significantly affected by the matter-scalar coupling. On scales comparable or shorter than the range of the local fifth force, the fifth force is perfectly parallel to gravity and their strengths have a fixed ratio 2{gamma}{sup 2} determined by the matter-scalar coupling, provided that the chameleon effect is weak; if on the other hand there is a strong chameleon effect (i.e., the scalar field almost resides at its effective potential minimum everywhere in the space), the fifth force indeed has suppressed effects in high density regions and shows no obvious correlation with gravity, which means that the dark-matter-scalar-field coupling is not simply equivalent to a rescaling of the gravitational constant or the mass of the dark matter particles. We show these spatial distributions and (lack of) correlations at typical redshifts (z=0,1,5.5) in our multigrid million-particle simulations. The viable parameters for the scalar field can be inferred on intermediate or small scales at late times from, e.g., weak lensing and phase space properties, while the predicted Hubble expansion and linearly simulated CMB spectrum are virtually indistinguishable from the standard {lambda}CDM predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗