Effect of alloying on grain refinement of electron-beam-melted tungsten
Effect of alloying on grain refinement of electron-beam-melted tungsten
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Effect of alloying on grain refinement of electron-beam-melted tungsten
Suspension of flat plate in parallel heated air stream - ablation and melting wave behavior
Method for determining thermal diffusivity of thermal energy storage solid materials with high melting points
Solid solution and carbide strengthened arc melted alloys of hafnium with tungsten and ternary alloys of tantalum, columbium, rhenium and carbon
Apparatus for melting boron carbide inductively on water-cooled hearth, noting application to other refractory materials
Lindemann, Grueneisen and melting laws in theory of normal properties of high pressure solids
Linear melting curve of fayalite up to 40 kb determined, using piston cylinder and thermocouples
Melt regions on Greenland ice are mapped daily with the SeaWinds wideswath Ku-band scatterometer on the QuikSCAT satellite.
The Earth's energy balance and hydrology are effected by the distribution and characteristics of snow cover on the surface. Snow grainsize and snow melt, influence surface albedo and hydrology.
The first in-situ field observations of Antarcic austral summer sea-ice melt were made in the Bellingshausen Sea by Arctowski (1908) on Belgica in 1899, and later by Wordie (1921) during the ill-fated drift of Endurance in the Weddell Sea from 1914-1916.
The Heat Melt Compactor (HMC) is designed to sterilize and process wastes produced during space missions. Benefits of the HMC include reduction of biohazards to the crew, reduction in volume of wastes that would otherwise require storage, production of radiation shielding tiles, and recovery of water and other resources. Water reuse is critical onboard spacecrafts; it reduces the need for resupply missions and saves valuable storage space. The main sources of water in HMC batches are food, beverages, shampoo, disinfecting wipes, toothpaste, and diapers. Water reclaimed by the HMC was analyzed for concentrations of Na+, NH4+, K+, Mg2+, Ca2+, Cl-‐, NO2-‐, Br-‐, NO3-‐, PO43-‐, SO42-‐, total organic carbon (TOC), total inorganic carbon (TIC), % total solids, and pH. The data are discussed in relation to the current water input characteristics established for the International Space Station Water Processor Assembly system. Batches with higher than average amounts of food produced HMC product water with higher sulfate content, and batches with higher proportions of disinfectant wipes and food yielded HMC product water with higher ammonium concentration. We also compared theoretical chemical composition of HMC product water based on food labels and literature values to experimental results.
Electrical resistivity (ER) measurements are a possible health monitoring technique for CMC components in future aerospace applications. In order to use ER measurements to detect and identify damage, it is necessary to understand how each specific damage state will affect the ER response. In this paper, finite element models are developed and applied to quantify the effect of specific damage states on the electrical resistivity response in a melt-infiltrated silicon carbide (SiC) fiber-reinforced silicon carbide composite. The electrical resistivity of several damage states are calculated by simulating the electric current flow through the damaged micro-structure. This is achieved by performing the numerical solution of the steady-state conservation of charge density equation. Numerical results reveal that cracking of the inter-tow matrix has the most profound effect on the composite electrical resistivity. Also, fiber/matrix debonding at matrix cracks in the 0° tows (tows aligned with the loading direction) may cause a significant increase in the electrical resistivity, but only if the fiber coating resistivity is 1000 Ω-cm or less. Cracks in the 90° tows and the crack opening displacement have very little effect on the composite electrical resistivity.
The processing of trash and waste is a welcome and valuable addition to humans living and working in space. Besides the obvious desire to have a pleasant and productive habitation environment, trash management has many practicalbenefits for crew health, resource recovery, and volume reclamation through garbage compaction. The Trash Compaction and Processing System (TCPS), which is a NASA project to develop a trash processing system for long-duration spaceflight, is currently undergoing concept development with engineering prototype validation through two contracted efforts. The development efforts are being supported with activities associated with the NASA Generation 2 Heat Melt Compactor (HMC). The HMC is a facility that compacts trash, recovers water, heats the trash to eliminate biological activity, and manages gas and vapor effluents. The resulting residual processed trash is a compact tile that is free of biological growth and that can be used for augmenting radiation shields. The work being conducted with the HMC focuses on high risk technical areas with respect to operations, subsystem performance, and ISS effluent management interface requirements. This paper gives an overview of the technical risks and the current use of the HMC as a facility for reducing risk.
The Heat Melt Compactor (HMC) reduces volume, heat sterilizes, stabilizes, and manages gas and water effluent of the International Space Station (ISS) trash. Processing the trash at high temperatures produces volatile gas compounds that need to be treated before venting to cabin and/or the Vacuum Exhaust System (VES) in the ISS. The release of gases may not meet the Spacecraft Maximum Allowable Concentrations (SMAC) requirement, if vented directly into cabin, and/or gases are incompatible for venting to the VES. In order to assess the HMC gas release and venting parameters, effluent gas analysis is conducted to determine contaminant load. This paper will analyze different collection and analytical methods of the effluent gas, and report corresponding data, such that these results can be used for process design and effluent management.
The Heat Melt Compactor (HMC) system has been developed to manage the waste generated on board spacecraft during long-duration missions. The quantity and composition of spacecraft trash depends upon the mission and can have a very high daily variability. This requires a flexible system able to manage extreme waste scenarios. Most missions will generate on average about one kilograms of trash per astronaut per day, derived mainly from the spacecraft logistics supplies and consisting of clothing, food & beverage residues, packaging, paper, plastic, hygiene wipes, and many other personal or scientific items used and discarded by the crew. Uncontained and unprocessed waste is a health hazard and a habitat storage problem. However, trash also contains valuable resources such as water. HMC is designed to provide volume reduction, microbial safening and stabilization, water recovery, and radiation shielding material. The final byproduct generated by HMC is a sterilized tile with the consistency of hard plastic that can be safely handled, easily stored, and used for radiation protection. This paper provides the summary of an extensive campaign of testing performed using the HMC system to simulate different nominal and extreme operational scenarios and to generate the data necessary to finalize requirements for proto-flight hardware to be deployed to an International Space Station (ISS) EXPRESS Rack.
The effluent gases and water vapor of the Trash Compaction and Processing System (TCPS) can be vented through the Vacuum Exhaust System (VES) if requirements are met. One of the constraints in this venting scenario is the dew point of the exhaust gases disposed into the VES must be less than 15.5 °C. With simulations using Aspen Plus and the effluent gas sample results of the Heat Melt Compactor (HMC), flash calculations were conducted in the modeling study to calculate the feed temperature and dew point at fixed pressures. Saturated vapor curves were produced and provided a preliminary result on optimal feed conditions that satisfy the dew point and vapor-phase only requirements after flashing across the throttle valve towards the VES.
The Heat Melt Compactor (HMC) recovers water from trash at low temperatures and under vacuum conditions to obtain relatively cleaner water with less contaminants. The effluent water vapor is condensed and collected for analysis. The objectives of the analysis are to identify chemical components in the water sample, evaluate water quality, and assess the compatibility of the liquid effluent with the International Space Station (ISS) water systems. The evaluation of water quality includes total organic carbon (TOC) concentrations which provide a general indication of overall water quality, other defining characteristics such as pH and conductivity, and comparison with previous ISS water analytical data as a baseline for the evaluation.
Processing of metallic melts in microgravity containerless experiments requires control of contaminants like oxygen and water vapor to below parts-per-billion (ppb) levels.