Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Calibration and field deployment of low-cost sensor network to monitor underground pipeline leakage

Recent technological advances in methane detection have improved leak detection and repair. However, current methods to reliably measure methane concentrations rely on expensive instruments or demand significant labor input. There is interest in using affordable methane sensors that are responsive to ppmv level changes in methane concentrations in both urban and rural environments for monitoring underground natural gas pipeline leaks. This is especially relevant for situations where potentially significant leaks cannot be repaired immediately or smaller leaks that require long-term monitoring and further evaluation. In this work, a low-cost sensor unit, equipped with a metal oxide sensor, was designed, built, and calibrated over a wide range of methane concentrations and environmental conditions in preparation for field application. A network of these sensors was then installed at the test site and used to measure methane concentrations at ground level above known sub-surface natural gas emissions which emulated underground gas pipeline leaks. This low-cost sensor network measured over 4 days total for the two different known leakage rates. Results demonstrate that the sensors can continuously measure relative methane variability for extended periods but require calibration for a wide range of temperature and humidity conditions to properly determine absolute gas (i.e., methane) concentrations. Furthermore, when a regression analysis was conducted to evaluate the effects of meteorological parameters on methane concentration, air temperature and wind speed have strong impacts on the concentration. Overall, the network approach allows improved identification of leak location and monitoring of underground natural gas leaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and implementation of a portable diagnostic system for Thomson scattering and optical emission spectroscopy measurements

A diagnostic system, which has a design goal of high-portability, has been designed at Oak Ridge National Laboratory (ORNL). This project aims at providing measurements of key plasma parameters (ne, Te, ni, Ti) for fusion-relevant devices, utilizing Thomson scattering (TS) and optical emission spectroscopy (OES). The innovative design employs mostly commercial off-the-shelf instrumentation and a traveling team of researchers to conduct measurements at various magnetic-confinement plasma devices. The TS diagnostic uses a Quantel Q-smart 1500 Nd:YAG laser with a 2ω harmonic generator to produce up to 850 mJ of 532 nm laser pulses at 10 Hz. Collection optics placed at the detection port consists of an 11 × 3 optical fiber bundle, where the TS diagnostic uses an 11 × 1 subset array of the fibers, the OES diagnostic uses another 11 fibers, and the remaining fibers are available to the host institution. The detection system is comprised of two separate IsoPlane-320 spectrometers with triple-grating turrets of various line spacing and two PI-MAX 4 intensified CCD detectors, used simultaneously to measure a broad range of ion, impurity, and electron parameters. The self-contained diagnostic package also includes a data processing and storage system. The design and initial implementation of the TS-OES diagnostic system are described. The experiments from the proof-of-principle operation of the portable package on a high density (∼2.5 × 1022 m−3) and low-temperature (∼5 eV) electrothermal arc source at ORNL are also discussed.

Kafle, N. (ORCID:000000028144787X)↗

A novel network-based approach to determining measurement representation error for model evaluation of aerosol microphysical properties

Atmospheric aerosol size and abundance influence radiative effects and climate change. To date, efforts to constrain global climate models’ radiative forcing with in situ aerosol observations have been hamstrung by uncertainty. One source of error, the regional “representation error,” arises when accurate but sparse single-point measurements of atmospheric aerosol distributions are compared with a model value, assuming that the single-point measurement is representative of the model domain. The Portable Optical Particle Spectrometer network in the Southern Great Plains (POPSnet-SGP) campaign has demonstrated that a network of nearly autonomous aerosol instruments operating at ambient temperature and relative humidity (with low measurement error) may be used to quantify measurement representation error and investigate the factors introducing heterogeneity in aerosol distributions across a rural, continental background region. Measurements were made using Portable Optical Particle Spectrometer (POPS) instruments at several sites for five months across the Department of Energy’s Aerosol Radiation Measurement Southern Great Plains (ARM-SGP) User Facility in the central USA. Measurement representation error decreased with longer averaging periods (20-40 % between 1 sec and 1 day), varied between sites by 10 – 20 % for aerosol concentration 140 – 2500 nm in diameter (N_140), and was higher for aerosols > 400 nm in diameter (N_400). Our measurements also show the influence of local meteorology on aerosol surface area (A_140) and size distributions: A_140 is positively correlated with wind speed and relative humidity, negatively correlated with precipitation, and lower given westerly winds. Based on this study, we conclude that the POPSnet approach provides considerably more insight into the spatial variability in the aerosol population that can be used to constrain climate models than would be available from similar networks of PM 2.5 monitors.

54 ENVIRONMENTAL SCIENCES↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

Low-Activity Waste Glass Standards Preparation and Characterization for Calibration of Analytical Instruments

A matrix of seven low-activity waste (LAW) glasses was fabricated and characterized to be used by the Hanford Waste Treatment and Immobilization Plant (WTP) as analytical instrument calibration and matrix interference standards when measuring LAW glass compositions. The matrix of glasses was designed to represent the range of LAW glass compositions that will be generated by the WTP. Samples from each of the seven glasses were measured with electron probe microanalysis (EPMA), ion chromatography (IC), and bulk inductively coupled plasma mass spectroscopy (ICP-MS) to determine the variability and accuracy across batches and within individually poured glass bar samples. High relative percent differences and standard deviations were calculated for components with low concentrations due to instrument detection limits. IC and ICP-MS percent differences and standard deviations were higher at low component concentrations. Otherwise, variability in measured compositions from IC and ICP-MS was generally lower than measurements from EPMA, with the exclusion of Cl, F, Si, and B. Overall, the two methods proved comparable and complementary. From EPMA, IC, and ICP-MS data, volatile elements were underrepresented compared to batched compositions, which suggested loss of these elements during melting. EPMA data was statistically analyzed to evaluate homogeneity within single bars and whole compositions for each of the seven glasses. Most of the variability within glass compositions occurred at the bar-to-bar level; however, no clear systematic trends were observed. Based on these analyses, when using these glasses as reference material, it is recommended that the overall mean and variance of each composition be used for performing instrument calibrations and analytical corrections.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A New Field Instrument for Leaf Volatiles Reveals an Unexpected Vertical Profile of Isoprenoid Emission Capacities in a Tropical Forest

Both plant physiology and atmospheric chemistry are substantially altered by the emission of volatile isoprenoids (VI), such as isoprene and monoterpenes, from plant leaves. Yet, since gaining scientific attention in the 1950’s, empirical research on leaf VI has been largely confined to laboratory experiments and atmospheric observations. Here, we introduce a new field instrument designed to bridge the scales from leaf to atmosphere, by enabling precision VI detection in real time from plants in their natural ecological setting. With a field campaign in the Brazilian Amazon, we reveal an unexpected distribution of leaf emission capacities (EC) across the vertical axis of the forest canopy, with EC peaking in the mid-canopy instead of the sun-exposed canopy surface, and moderately high emissions occurring in understory specialist species. Compared to the simple interpretation that VI protect leaves from heat stress at the hot canopy surface, our results encourage a more nuanced view of the adaptive role of VI in plants. We infer that forest emissions to the atmosphere depend on the dynamic microenvironments imposed by canopy structure, and not simply on canopy surface conditions. We provide a new emissions inventory from 52 tropical tree species, revealing moderate consistency in EC within taxonomic groups. We highlight priorities in leaf volatiles research that require field-portable detection systems. Our self-contained, portable instrument provides real-time detection and live measurement feedback with precision and detection limits better than 0.5 nmol VI m -2 leaf s -1 . We call the instrument ‘PORCO’ based on the gas detection method: photoionization of organic compounds. We provide a thorough validation of PORCO and demonstrate its capacity to detect ecologically driven variation in leaf emission rates and thus accelerate a nascent field of science: the ecology and ecophysiology of plant volatiles.

54 ENVIRONMENTAL SCIENCES↗

Characterizing Greater Houston's Aerosol by Air Mass During TRACER

During the TRacking Aerosol and Convection interaction ExpeRiment (TRACER), a suite of aerosol and cloud measurements were made using the Texas A&M Rapid Onsite Atmospheric Measurement Van (ROAM-V) mobile instrument platform. Joint ROAM-V/radiosonde deployments focused on sampling polluted marine and continental air masses to understand summertime convection along and across the sea-breeze front as it propagated through Houston. The polluted marine air mass at Seawolf Park, Galveston, TX was defined by two characteristic aerosol populations. Although the background total particle concentrations averaged 2,500 cm −3 , the air mass was also influenced by frequent but irregular periods of ship emission with significantly higher aerosol concentrations at times exceeding 34,000 cm −3 . Ship emission influenced periods, typically lasting <10 min, contained smaller, less hygroscopic particles resulting in a 69% relative decline in cloud condensation nuclei (CCN) activated fraction at 1% supersaturation compared to background periods. Measurements in continental air masses northwest of Houston revealed an average aerosol concentration of 5,208 cm −3 with a κ value near 0.1 reasonably describing the CCN population, independent of particle size. In continental air masses, substantial differences in particle size and CCN activation over small distances (<42 miles between sites) suggest considerable site-to-site variability in addition to the expected day-to-day differences. This small-scale variability makes it difficult to generalize continental air mass aerosol properties. Both coastal and inland locations had effective ice nucleating particles, but inland deployments observed the warmest nucleation temperature at −15.6°C compared to −17.8°C close to the coast. These measurements can reduce uncertainties in regional convection allowing models to improve understanding of aerosol-cloud interactions.

54 ENVIRONMENTAL SCIENCES↗

Design and performance of a variable gap system for thermal conductivity measurements of high temperature, corrosive, and reactive fluids

We report high-temperature fluids such as molten salts, liquid metals, and gasses are being proposed for many advanced energy systems including thermal energy storage devices, concentrating solar plants, and advanced nuclear reactor designs. However, the chemical behavior and thermophysical properties of many of these fluids have not been well characterized, which hinders the design, modeling, safety analysis, and deployment of these systems. Thermal conductivity is a property that is especially limited by existing measurement capabilities, which are subject to errors caused by convection, material interaction, radiative heat transfer, and instrument degradation. Therefore, there is a lack of standard, systematic measurement techniques for high-temperature, reactive, and corrosive fluids. In this work, the development of a variable gap thermal conductivity measurement system is detailed. The system is designed to measure the thermal conductivity of highly corrosive and reactive fluids, and survive operation between 100 °C and 800 °C. The effects of convection are minimized by limiting the thickness of the specimen to thin sizes (<0.3 mm). Corrections for radiative heat transfer were included in the working equations to consider specimens with varying optical properties. The design, construction, instrumentation, operating principles, and data analysis techniques are discussed in detail. The system was tested up to 500 °C using helium gas and molten KNO 3 -NaNO 3 to verify the measurement technique and determine the sources of error. At 300 and 400 °C KNO 3 -NaNO 3 , results showed maximum relative error of 6% when compared to results in the literature. The helium results were within 13% of those in the literature at 300 and 400 °C. Higher errors were observed at 500 °C for both fluids, and the sources of these errors are discussed.

42 ENGINEERING↗

Analyze the real-time performance of the optimized fiber-PTR instrument

An instrument to perform in-reactor, real-time thermal property measurements of nuclear fuels and materials was recently designed, optimized, and tested at Massachusetts Institute of Technology Research Reactor. It was the second insertion experiments of a total of two rounds. Here we report the collection and analysis of the real-time captured thermal diffusivity data on the preloaded SiC. With the optimized design, the instrument temperature had been successfully raised as we expected. Only one probe (the top one) returned real-time thermal diffusivity in a time span of approximately two days. Measured thermal diffusivity of the preloaded SiC was significantly lower than the literature value at the same temperature, indicating a significant influence from the irradiation induced microstructure damage. Meanwhile, the real-time thermal diffusivity value continuously reduced with time, indicating the dynamic microstructure evolution. The possible reasons of the probes that did not return data were hypothesized. The further optimization of the instrument with the objective to improve the measurement accuracy and instrument survivability is also discussed.

36 MATERIALS SCIENCE↗

LyaCoLoRe : synthetic datasets for current and future Lyman-α forest BAO surveys

The statistical power of Lyman-α forest Baryon Acoustic Oscillation (BAO) measurements is set to increase significantly in the coming years as new instruments such as the Dark Energy Spectroscopic Instrument deliver progressively more constraining data. Generating mock datasets for such measurements will be important for validating analysis pipelines and evaluating the effects of systematics. With such studies in mind, here we present LyaCoLoRe: a package for producing synthetic Lyman-α forest survey datasets for BAO analyses. LyaCoLoRe transforms initial Gaussian random field skewers into skewers of transmitted flux fraction via a number of fast approximations. In this work we explain the methods of producing mock datasets used in LyaCoLoRe, and then measure correlation functions on a suite of realisations of such data. We demonstrate that we are able to recover the correct BAO signal, as well as large-scale bias parameters similar to literature values. Finally, we briefly describe methods to add further astrophysical effects to our skewers — high column density systems and metal absorbers — which act as potential complications for BAO analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Ice Nucleation Measurements during TRACER (Field Campaign Report)

This campaign, Ice Nucleation Measurements during TRACER, was conducted during the TRacking Aerosol Convection Interactions ExpeRiment (TRACER) in Houston, Texas during June-September, 2022. Specifically, our ice nucleation campaign was designed to improve understanding of ice nucleating particles (INPs) and their role in deep convective clouds across the Houston region. Summertime deep convection in southeast Texas is regularly tied to the sea-breeze front (SBF) that pushes inland from the Gulf of Mexico across the region. During TRACER, three Davis Rotating Uniform size-cut Monitors (DRUM; DRUMAir 4-DRUM) were used to collect aerosols for offline ice nucleation measurements in the Brooks laboratory at Texas A&M University. The three instruments were located at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) first Mobile Facility (AMF1) in La Porte, at the ancillary site in Guy (ANC), and onboard the newly developed Texas A&M Rapid Onsite Atmospheric Measurements Van (ROAM-V). Aerosol at the main ARM TRACER site, ARM1, is expected to arise from local urban, industrial, and ship channel sources. In contrast, the ANC is isolated and rural, and can therefore provide a continental background aerosol population. On select days when convective development was forecast to be probable, ROAM-V commuted from College Station, Texas to Galveston, sampled in the morning/mid-day on the coast, and then transited to a second inland site for the afternoon/evening. Sampling from the ROAM-V allowed us to capture aerosol and meteorological differences between maritime and continental airmasses by strategically positioning the ROAM-V near the coast in the morning in the opposite airmass from the AMF1 site.

54 ENVIRONMENTAL SCIENCES↗

CACTI ARM Aerial Facility Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0&deg;C down to -26 to -29&deg;C) of atmospheric ice nucleating particle (INP) concentrations taken on the Atmospheric Radiation Measurement (ARM) program Aerial Facilty (AAF) G-1 aircraft. INP measurements on the G-1 were collected from varied altitudes on different flights over the region of the Sierras de C&oacute;rdoba mountain range of north-central Argentina, centred over ARM's Mobile Facility (AMF-1) near Villa Yacanto, where ground-based INP measures were being taken concurrently. Both studies took place as part of the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampling system was deployed on the G-1 to collect aerosol particles for post-processing of INPs collected on filters (measuring their immersion freezing ability) once returned to Colorado State University (CSU). Filter holders used were pre-cleaned aluminum in-line units loaded with pre-cleaned and pre-sterilized 47 mm dia. Nuclepore polycarbonate filters (0.2 mm pore size). Filters were drawn for varied times, resulting in varied volumes collected (51 to 1667 SL). Mass flow rate was recorded in real-time so that total sampled volume (at standard temperature and pressure) could be determined. A total of 34 sample filters were collected over the IOP, including 5 blanks. Filters were stored at -20&deg;C freezer prior to frozen return to Colorado State University (CSU). . Processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7 mL of 0.02 &micro;m-filtered deionized water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33&deg;C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. Aliquots of suspensions from selected samples were also heat treated (95&deg;C for 20 min) to denature and deactivate biological INPs, and digested in 10% H2O2 at 95&deg;C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O&rsquo;Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196&ndash;6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402&ndash;409.

54 ENVIRONMENTAL SCIENCES↗

LANL MPCL Measurement System Analysis: AMPTEC 630ES Igniter Tester / Ohmmeter

This comprehensive analysis aimed to evaluate the measurement capability of the AMPTEC 630ES Explosive Safety Igniter Tester, a critical tool for organizations engaged in the measurement of High Explosive components and related Electro-Explosive devices. With a history of notable calibration issues involving specific model numbers, the Metrology Program and Calibration Laboratory (MPCL) initiated an extensive Measurement System Analysis. The analysis's primary focus was to thoroughly quantify the various sources of measurement variability intrinsic to the calibration process. It centered on two pivotal aspects: repeatability (the variation observed when the same operator uses the same instrument) and reproducibility (the variation seen when different operators perform measurements). A secondary objective was to determine whether equipment usage and age had any impact on the instrument's performance.

47 OTHER INSTRUMENTATION↗

Novel design for a polarizing DUV spectrometer using a Wollaston prism and its application as a diagnostic for measuring Thomson scattering data in the presence of strong self-emission backgrounds

We present a novel design for an optical spectrometer for use in ultraviolet Thomson scattering measurements of plasma parameters in high energy density (HED) inertial confinement fusion experiments on large-scale high-energy laser facilities. In experiments investigating high-Z plasmas, the fidelity of measurements is commonly limited by signal/background ratios approaching or exceeding unity. An alpha barium borate Wollaston prism can provide both spectral dispersion and polarization channel separation, allowing simultaneous measurement of both the Thomson scattering signal and plasma self-emission along a single line of sight and in a single experiment, which should greatly improve data quality and reduce the opportunity cost of taking high quality measurements. Here, we present a basic discussion of the design and a worked example of an instrument designed to take fourth harmonic electron plasma wave measurements in HED experiments at the OMEGA laser facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operationally induced preferred basis in unitary quantum mechanics

The preferred-basis problem and the definite-outcome aspect of the measurement problem persist even if the detector is modeled unitarily, because experimental data are necessarily represented in a Boolean event algebra of mutually exclusive records whereas the theoretical description is naturally formulated in a noncommutative operator algebra with continuous unitary symmetry. This change of mathematical type constitutes the core of the 'cut': a structurally necessary interface from group-based kinematics to set-based counting. In the presented view the basis relevant for recorded outcomes is not determined by the system Hamiltonian alone; it is induced by the measurement mapping, i.e., by the detector channel together with the coarse-grained readout that defines an instrument. The probabilistic mapping is anchored in symmetry and measure theory: by Gleason-type uniqueness (Gleason for projections in $d>2$ and Busch's extension for Positive Operator-Valued Measures (POVMs) including $d=2$), the trace rule is the unique probability measure consistent with additivity over exclusive events and basis-independence of the unitary sector. A compact qubit--pointer model yields an induced unsharp POVM $E_\pm=\tfrac12(\id\pm η\,σ_z)$ with $η$ fixed by pointer resolution, displaying explicitly how the detector induces the relevant basis. Finally, nested-observer paradoxes are tightened into a non-composability lemma: joint assignment of outcome propositions is obstructed unless a joint instrument exists. This relocates the origin of randomness to the stochasticity of the transition rules.

Pronskikh, Vitaly [Fermilab] (ORCID:00000002518174↗

CACTI ARM Mobile Facility (AMF) Measurements of Ice Nucleating Particles

The dataset comprises measures, using Colorado State University's Ice Spectrometer (IS, an immersion freezing device with a range from 0&deg;C down to -26 to -29&deg;C) of atmosperic ice nucleating particle (INP) concentrations taken on ARM's Mobile Facility (AMF-1) Aerosol Observing System, near Villa Yacanto in central Argentina, during the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) Experiment. A filter sampler was mounted on the AOS trailer (2 m below the AOS inlet). Single-use filter units open to the atmosphere fitted with pre-cleaned and pre-sterilized, 47-mm dia. Nuclepore polycarbonate filters were used. Filters were typically drawn for an 8-hour period, totaling 6000 liters sampled on average. After collection, filters were stored at -20&deg;C until processed. Initial processing to obtain spectra of INP number concentration active via the immersion freezing mechanism versus temperature was conducted using CSU's IS instrument (McCluskey et al., 2018). For measurment of INPs, collected aerosol particles were re-suspended in 7-8 mL of 0.1 &micro;m-filtered deionized (DI) water. Aliquots of each suspension, and serial dilutions, were dispensed into trays which were fit into aluminum blocks in the IS. Samples are cooled at 0.33&deg;C min-1 and the freezing temperatures of wells recorded automatically. Cumulative INP concentrations were determined by first calculating the INPs per mL of suspension based on Vali (1971) and then converting to concentration per standard liter of air using the proportion of the total liquid sample dispensed and the air sample volumes. An aliquot of suspension fro selected samples were also heat treated (95&deg;C for 20 min) to denature and deactivate biological INPs, and another aliquot digested in 10% H2O2 at 95&deg;C under UV-B to remove all organic carbon INPs. McCluskey, C. S., J. Ovadnevaite, M. Rinaldi, J. Atkinson, F. Belosi, D. Ceburnis, S. Marullo, T. C. J. Hill, U. Lohmann, Z. A. Kanji, C. O&rsquo;Dowd, S. M. Kreidenweis, P. J. DeMott, 2018: Marine and Terrestrial Organic Ice Nucleating Particles in Pristine Marine to Continentally-Influenced Northeast Atlantic Air Masses, Journal of Geophysical Research: Atmospheres, 123, 6196&ndash;6212, https://doi.org/10.1029/2017JD028033. Vali, G., 1971: Quantitative evaluation of experimental results on the heterogeneous freezing nucleation of supercooled liquids. J. Atmos. Sci., 28, 402&ndash;409.

54 ENVIRONMENTAL SCIENCES↗

Incompatibility as a Resource for Programmable Quantum Instruments

Quantum instruments represent the most general type of quantum measurement, as they incorporate processes with both classical and quantum outputs. In many scenarios, it may be desirable to have some “on-demand” device that is capable of implementing one of many possible instruments whenever the experimenter desires. We refer to such objects as programmable instrument devices (PIDs), and this paper studies PIDs from a resource-theoretic perspective. A physically important class of PIDs are those that do not require quantum memories to implement, and these are naturally “free” in this resource theory. Additionally, these free objects correspond precisely to the class of unsteerable channel assemblages in the study of channel steering. The traditional notion of measurement incompatibility emerges as a resource in this theory since any PID controlling an incompatible family of instruments requires a quantum memory to build. We identify an incompatibility preorder between PIDs based on whether one can be transformed into another using processes that do not require additional quantum memories. Necessary and sufficient conditions are derived for when such transformations are possible based on how well certain guessing games can be played using a given PID. Ultimately our results provide an operational characterization of incompatibility, and they offer semi-device-independent tests for incompatibility in the most general types of quantum instruments. Published by the American Physical Society 2024

Physics↗

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds↗