Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Advances in geophysical forensic event monitoring

Forensic analysis of man-made, non-nuclear events (such as industrial accidents, explosion experiments and mine collapses) has become more frequent and detailed owing to advancements in geophysical monitoring. Here, in this Technical Review, we demonstrate how geophysical forensic monitoring using seismic, infrasound and hydroacoustic recordings provides insights on events in the solid earth, atmosphere and underwater. Advanced techniques, including machine-learning-based models, have been developed to detect, identify and investigate these events, providing information on location, subevents, sources and explosive yield. The increase in data availability, application of advanced methods and computation and the growth of multitechnology approaches have increased the accuracy of forensic event analysis and enabled more realistic characterization of uncertainties. For example, the 2020 Beirut explosion in Lebanon demonstrated that various seismic, acoustic and other methods could be used to estimate explosive yield (and yield uncertainties) of about 1 ktonne, providing confidence in the application of these methods to smaller events where data are available. However, forensic investigations remain largely limited to known events with identified sources. Increased access to data, sophisticated analysis methods and high-resolution earth models will improve forensic event analysis further, enabling civil and scientific applications, such as localization in the search for the lost ARA San Juan submarine.

geophysics↗

Automated instant labeling chemistry workflow for real-time monitoring of monoclonal antibody N -glycosylation

With the transition toward continuous bioprocessing, process analytical technology (PAT) is becoming necessary for rapid and reliable in-process monitoring during biotherapeutics manufacturing. Bioprocess 4.0 is looking to build end-to-end bioprocesses that include PAT-enabled real-time process control. This is especially important for drug product quality attributes that can change during bioprocessing, such as protein N-glycosylation, a critical quality attribute for most monoclonal antibody (mAb) therapeutics. Glycosylation of mAbs is known to influence their efficacy as therapeutics and is regulated for a majority of mAb products on the market today. Currently, there is no method to truly measure N-glycosylation using on-line PAT, hence making it impractical to design upstream process control strategies. We recently described the N-GLYcanyzer workflow: an integrated PAT unit that measures mAb N-glycosylation within 3 hours of automated sampling from a bioreactor. Here, we integrated Agilent's Instant Procainamide (InstantPC) based chemistry workflow into the N-GLYcanyzer PAT unit to allow for nearly 10× faster near real-time analysis of mAb glycoforms. Furthermore, our methodology is explained in detail to allow for replication of the PAT workflow as well as present a case study demonstrating the use of this PAT to autonomously monitor a mammalian cell perfusion process at the bench scale to gain increased knowledge of mAb glycosylation dynamics during continuous biologics manufacturing using Chinese hamster ovary (CHO) cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards non-contact pollution monitoring in sewers with hyperspectral imaging

Monitoring water quality in sewers is challenging, particularly because state-of-the-art technologies require contact with the raw wastewater. The presence of fat, oil, grease, and solids makes automated grab sampling difficult and causes sensor fouling. To overcome these limitations, non-contact methods based on light reflectance, such as hyperspectral imaging (HSI), are gaining attention. However, HSI has never been tested for raw wastewater. To assess its accuracy for measuring pollution, we developed a laboratory setup and performed targeted experiments with a combination of raw and diluted wastewater, as well as synthetic turbidity stock solutions. We measured seven pollution variables: chemical oxygen demand, turbidity, dissolved organic compounds, ammonium, total nitrogen, phosphate, and sulphates. We used automated pixel selection and partial least squares regression to retrieve pollution information from the hyperspectral images. Our results, based on 144 samples, suggest that HSI can estimate pollution levels with a precision in the range of state-of-the-art absorbance spectrophotometric methods. Additionally, we found that the combination of pixel and wavelength selection, enabled by the hyperspectral data structure, significantly influences the performance of partial least square modelling. Overall, our findings indicate that HSI is a promising technology for non-contact monitoring of water quality in raw wastewater.

54 ENVIRONMENTAL SCIENCES↗

Real-time elemental analysis of liquids for process monitoring using laser-induced breakdown spectroscopy with a liquid wheel sampling approach

This article presents an engineered sampling system that used a rotating wheel to form a thin liquid layer, permitting the use of laser-induced breakdown spectroscopy (LIBS) for in situ, real-time elemental impurity quantification during liquid processing. The sampling approach was demonstrated on eight elements from across the periodic table (Na, Al, K, Ca, Ti, Sr, Mo, and Yb). Univariate and multivariate calibrations were presented for each element. The average value for percent root mean square errors of cross-validation for the multivariate models was 3.64%, highlighting the method's strong prediction accuracy. Additionally, the limits of detection for each analyte were estimated from their univariate models: Na = 0.0532, Al = 18.5, K = 0.105, Ca = 0.273, Ti = 67.7, Sr = 0.640, Mo = 22.4, and Yb = 22.9 μg mL –1 . Finally, a test in which multivariate models were used to monitor a liquid system for 80 min was performed to investigate the real-time monitoring capabilities of this liquid LIBS sampling approach. Rigorous measurements were performed to effectively predict the absence and concentrations of multiple analytes as they were spiked and diluted. This demonstration showed the feasibility of using LIBS for real-time liquid quantification models with estimated precision ≤ 8.1%. Finally, the limitations of this approach and potential future improvements are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TDCOSMO: II. Six new time delays in lensed quasars from high-cadence monitoring at the MPIA 2.2m telescope

In this paper we present six new time-delay measurements obtained from $R_c$-band monitoring data acquired at the Max Planck Institute for Astrophysics (MPIA) 2.2 m telescope at La Silla observatory between October 2016 and February 2020. The lensed quasars HE 0047–1756, WG 0214–2105, DES 0407–5006, 2M 1134–2103, PSJ 1606–2333, and DES 2325–5229 were observed almost daily at high signal-to-noise ratio to obtain high-quality light curves where we can record fast and small-amplitude variations of the quasars. We measured time delays between all pairs of multiple images with only one or two seasons of monitoring with the exception of the time delays relative to image D of PSJ 1606–2333. The most precise estimate was obtained for the delay between image A and image B of DES 0407–5006, where $τ_{AB} = –128.4_{–3.8}^{+3.5}$ d (2.8% precision) including systematics due to extrinsic variability in the light curves. For HE 0047–1756, we combined our high-cadence data with measurements from decade-long light curves from previous COSMOGRAIL campaigns, and reach a precision of 0.9 d on the final measurement. The present work demonstrates the feasibility of measuring time delays in lensed quasars in only one or two seasons, provided high signal-to-noise ratio data are obtained at a cadence close to daily.

79 ASTRONOMY AND ASTROPHYSICS↗

Anomaly Detection Based on Machine Learning for the CMS Electromagnetic Calorimeter Online Data Quality Monitoring

Using a semi-supervised machine learning approach we present a real-time anomaly detection system based on an autoencoder used for online data quality monitoring of the CMS electromagnetic calorimeter operating at the CERN LHC. We introduce a novel method that maximizes the anomaly detection performance making use of the time-dependence of anomalies and the spatial variations in the detector response. The autoencoder-based system efficiently detects anomalies in real time and maintains a very low false discovery rate. We validate the performance of this novel system with anomalies from LHC collision data taken in 2018 and 2022. In addition, results are presented after deploying the autoencoder-based system in the CMS online Data Quality Monitoring workflow at the beginning of LHC Run 3 resulting in the system to detect issues that were missed by the existing system.

Harilal, Abhirami [Carnegie Mellon University, Pit↗

Sensor Placement Optimization Software Applied to Site-Scale Methane-Emissions Monitoring

Advances in sensor technology have increased our ability to monitor a wide range of environments. However, even as the cost of sensors decline, only a limited number of sensors can be installed at any given site. The physical placement of sensors, along with the sensor technology and operating conditions, can have a large impact on our ability to adequately monitor environmental change. This paper introduces a new open-source Python package, called Chama, that determines optimal sensor placement and technology to improve a sensor network’s detection capabilities. Additionally, the methods are demonstrated using site-specific methane emission scenarios that capture uncertainty in wind conditions and emission characteristics. Mixed-integer linear programming formulations are used to determine sensor locations and detection thresholds that maximize detection of the emission scenarios. The optimized sensor networks consistently increase the ability to detect leaks, as compared to sensors placed near each potential emission source or along the perimeter of the site.

47 OTHER INSTRUMENTATION↗

Edge AI-Enhanced Traffic Monitoring and Anomaly Detection Using Multimodal Large Language Models

This paper addresses the challenge of traffic monitoring and incident detection in remote areas, utilizing multimodal large language models (LLMs) deployed on edge AI devices. The key novelty of the LLM is to convert real-time video streams into descriptive texts, enabling low-bandwidth transmissions and reliable detection of anomalies and incidents in environments of intermittent connectivity. The model is developed based on fine-tuning open-source LLMs and extending it with multi-modal capabilities to analyze video frames. Our work also involves deploying this model on edge devices such as Nvidia IGX Orin and is planned to be tested in realistic environments in future work. The methodology includes data set curation, iterative model fine-tuning and compression, and hardware-based optimization. This approach aims to enhance traffic safety and response speed in remote areas, marking a significant advancement in the application of AI for traffic monitoring and safety management.

Peruski, Ryan [University of Tennessee, Knoxville ↗

Multichannel gas-uptake/evolution reactor for monitoring liquid-phase chemical reactions

The design of a headspace pressure-monitoring reactor for measuring the uptake/evolution of gas in gas–liquid chemical transformations is described. The reactor features a parallel setup with ten-reactor cells, each featuring a low working volume of 0.2–2 ml, a pressure capacity from 0 to 150 PSIa, and a high sensitivity pressure transducer. The reactor cells are composed of commercially available disposable thickwalled glassware and compact monolithic weld assemblies. The software interface controls the reactor temperature while monitoring pressure in each of the parallel reactor cells. Reactions are easy to set up and yield high-density gas uptake/evolution data. This instrument is especially well suited to acquire quantitative time-course data for reactions with small quantities of gas consumed or produced.

47 OTHER INSTRUMENTATION↗

Monitoring Methods for Early Detection of Inadvertent Fission Product Release at the Advanced Test Reactor

Isotope effluent data obtained during three instances of experiment failures at the Advanced Test Reactor (ATR) are analyzed to provide an overview of the methods used to detect initial signs of unintended fission product release. The data is contextualized with the operational experience, including means of identification and subsequent mitigation strategies, gained during these events. General trends as well as variations in isotopic behavior between the three failures are explored. Background on the Real Time Monitor, a High Purity Germanium detector, and other fission product monitoring systems utilized at the Advanced Test Reactor is also provided. The presented analysis was used to establish administrative action levels which are currently utilized by ATR for early detection of experiment fission product release. Early identification provides time to make programmatic decisions before approaching safety and environmental limits.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

In situ effective pumping speed measurements as a tool for non-evaporable getter activation and saturation monitoring

We have developed method of in situ effective pumping speed measurements based on injecting finite gas pulse into a vacuum volume and subsequent recording of pressure response using a Residual Gas Analyzer (RGA). The pressure burst caused by injected gas pulse falls exponentially in time and the exponential coefficient of such pressure decay is proportional to total effective pumping speed of all vacuum pumps acting on vacuum chamber volume. The effective pumping speed can be extracted from the dependence of injected gas species pressure vs time recorded by an RGA. Non-Evaporable Getters (NEGs) are widely used in multiple ultra and extremely high vacuum devices and applications during the last several decades. Areas of NEG applications were recently expanded into vacuum devices with relatively high-pressure levels (up to 10 -7 Torr) by the invention of high capacity ZAO NEG which can be operated at elevated temperatures. The intrinsic property of all NEG-based vacuum pumps is the reduction of their pumping speed, called “NEG saturation”, after an extended period of operation. Typical time interval for such process can span from about a month and up to a few years depending on NEG type, vacuum level of NEG pump operation, and residual gas content. After that, the NEG pump will require a re-activation cycle to restore its pumping speed close to the initial value. For many applications it is difficult to realize what is the current pumping speed of NEG pump is and when the pump should be re-activated. A method for in situ effective pumping speed measurements developed in this study can be used as a tool for NEG-based pump activation and saturation monitoring. Application of such an approach to monitor pumping status of NEG pumps was utilized and will be continually used at Extended EBIS which was recently developed and commissioned for Relativistic Heavy Ion Collider (RHIC) and future Electron Ion Collider (EIC). The results obtained during commissioning are presented and discussed.

43 PARTICLE ACCELERATORS↗

Optimization and characterization of a silicon photomultiplier-based ZnS(Ag) proton recoil fast neutron detector for nuclear fuel performance monitoring at TREAT

The restart of the Transient Reactor Test Facility (TREAT) at Idaho National Laboratory and consequent refurbishment of the Fuel Motion Monitoring System (FMMS), or Hodoscope, offers the opportunity to upgrade the detector system used for neutron imaging. Silicon photomultipliers (SiPMs) are a viable option for updating the Hodoscope to yield improved fuel monitoring capability. The Hodoscope uses ZnS(Ag) proton recoil scintillators (PRS) that provide good gamma-ray suppression and discrimination. Previous work showed that the Hamamatsu S13360-6075CS SiPM offers the best neutron detection and gamma-ray discrimination capability with the ZnS PRS. This work optimizes a SiPM-based detector and develops a PRS prototype for testing. Specifically, possible overvoltages for use are determined by confirming steady operation over extended measurement times. In addition, various SiPM-circuit implementations are tested to optimize the detector according to desired properties, and ultimately a PRS prototype is developed with modifiable components for versatile testing. Measurements of the neutron detection efficiency and gamma-ray rejection efficiency of SiPM-based PRS detectors and a reference PMT-based detector are also carried out. Neutron detection efficiency ranges between 1-2%, and detected gamma-ray rejection efficiency is on the order of 10 -7 . In conclusion, use of a low-pass filter only or a low-pass filter and 50-ω shunt resistor is recommended for the SiPM-based detector, and both configurations demonstrate improved performance over the PMT-based detector.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

A novel liquid argon purity monitor based on 207 Bi

A novel liquid argon purity monitor based on a 207 Bi radioactive source, emitting monochromatic internal-conversion electrons, is presented. This new monitor allows for a very precise and fast measurement of the electronegative impurities concentration in liquid argon. It can be operated continuously in liquid argon TPC experiments without interfering with the main detector operation. Different drift lengths can be assembled for the proposed device, to assess a large range of liquid argon purities while minimizing systematic uncertainties. Two prototypes have been built and successfully operated in dedicated test stands. The results and performance are reported.

double-phase↗

Relocating microseismicity from downhole monitoring of the Decatur CCS site using a modified double-difference algorithm

SUMMARY The injection of CO2 at the Decatur carbon capture and storage site has generated significant microseismic activity, which occurs in distinct spatial clusters up to approximately 2.2 km from the primary injection well. Accurate and precise event locations are vital for the characterization of the microseismicity to help understand the reservoir response to the CO2 injection, whilst enabling the identification of minor faults and fractures below the resolution of conventional active seismic imaging. However, microseismic monitoring of fluid injection sites, such as Decatur, is often performed using a network of borehole sensors often from a single well. While these downhole sensors have excellent detection capabilities, their poor azimuthal coverage limits the ability to precisely determine event locations. We have developed a modified double-difference relocation algorithm suitable for both 1-D and 3-D velocity models, and which incorporates differential back azimuth observations to allow the benefits of the original double-difference algorithm to be applicable to a downhole microseismic monitoring setting. Applying the modified double-difference algorithm to the microseismicity at Decatur, we have successfully relocated 4293 events. The relocation included over 59 million observations for 757 285 event pairs, split across seven geographic regions. Despite the majority of observations being recorded in only two boreholes, with an almost identical azimuthal coverage, the results have shown to be reliable with significantly reduced residuals and low uncertainties associated with the final locations. We have analysed the residuals in terms of their association with each geographic region, data type, station and individual events, to fully appreciate their influence in the inversion and the fit of the data to the final set of event locations. For each region, the relocated seismicity has become less diffuse with improved clustering, and with newly visible linear features often orientated in a NE–SW direction. These results show the potential improvements that can be made to microseismic event locations recorded by a borehole network with a limited and variable azimuthal distribution.

58 GEOSCIENCES↗

Monitoring natural gas storage using Synthetic Aperture Radar: are the residuals informative?

Estimates of line-of-sight (LOS) displacements from Interferometric Synthetic Aperture Radar (InSAR) observations serve as the basis of the long-term monitoring of an operating natural gas storage site at Honor Rancho in California. Here, an inversion algorithm is used to estimate the portion of the signal that is attributable to deformation within the gas storage reservoir, located at a depth of around 3 km. Removing this contribution produces residuals that are used to characterize the background variation is surface deformation at the gas storage facility and to determine a threshold that can signify unusually large residuals. An application to almost 7 yr of InSAR data, from 2011 until 2018, indicates that there are intervals of heightened residuals as well as brief episodes of anomalously large misfits. An examination of the spatial distributions of the individual residual LOS displacements indicates larger displacements in an alluvial valley just south of the reservoir, with rapid spatial variations in sign, indicating a rather shallow origin. Furthermore, the two anomalous events also involve rapid spatial variations in the LOS displacement residuals directly above the storage facility. The results demonstrate that the technique of extracting residuals after removing the reservoir signal is a useful approach, even in the case of this deep reservoir, and is a promising method for long-term monitoring.

03 NATURAL GAS↗

Elucidation of complex respiratory chains: a straightforward strategy to monitor electron transfer between cytochromes

Abstract Cytochromes are electron transfer (ET) proteins essential in various biological systems, playing crucial roles in the respiratory chains of bacteria. These proteins are particularly abundant in electrogenic microorganisms and are responsible for the efficient delivery of electrons to the cells’ exterior. The capability of sending electrons outside the cells open new avenues to be explored for emerging biotechnological applications in bioremediation, microbial electrosynthesis, and bioenergy fields. To develop these applications, it is critical to identify the different redox partners and to elucidate the stepwise ET along the respiratory paths. However, investigating direct ET events between proteins with identical features in nearly all spectroscopic techniques is extremely challenging. Nuclear magnetic resonance (NMR) spectroscopy offers the possibility to overcome this difficulty by analysing the alterations of the spectral signatures of each protein caused by electron exchange events. The uncrowded NMR spectral regions containing the heme resonances of the cytochromes display unique and distinct signatures in the reduced and oxidized states, which can be explored to monitor ET within the redox complex. In this study, we present a strategy for a fast and straightforward monitorization of ET between c-type cytochromes, using as model a triheme periplasmic cytochrome and a membrane-associated monoheme cytochrome from the electrogenic bacterium Geobacter sulfurreducens. The comparison between the 1D 1H NMR spectra obtained for samples containing the two cytochromes and for samples containing the individual proteins clearly demonstrated a unidirectional ET within the redox complex. This strategy provides a simple and straightforward means to elucidate complex biologic respiratory ET chains.

Morgado, Leonor (ORCID:0000000237605180)↗

Follow-up observations for IceCube-170922A: Detection of rapid near-infrared variability and intensive monitoring of TXS 0506+056

Abstract We present our follow-up observations to search for an electromagnetic counterpart of the IceCube high-energy neutrino IceCube-170922A. Monitoring observations of a likely counterpart, TXS 0506+056, are also described. First, we quickly took optical and near-infrared images of seven flat-spectrum radio sources within the IceCube error region right after the neutrino detection and found a rapid flux decline of TXS 0506+056 in Kanata/HONIR J-band data. Motivated by this discovery, intensive follow-up observations of TXS 0506+056 were continuously performed, including our monitoring imaging observations, spectroscopic observations, and polarimetric observations in optical and near-infrared wavelengths. TXS 0506+056 showed a large-amplitude (∼1.0 mag) variability in a time scale of several days or longer, although no significant variability was detected in a time scale of a day or shorter. TXS 0506+056 also showed a bluer-when-brighter trend in optical and near-infrared wavelengths. Structure functions of the variabilities were examined and indicate that TXS 0506+056 is not a special blazar in terms of optical variability. Polarization measurement results of TXS 0506+056 are also discussed.

(galaxies:) BL Lacertae objects: general↗

Precision beam diagnostics at the NuMI facility using muon monitor observations

The Neutrinos at the Main Injector (NuMI) facility at Fermilab delivers an intense neutrino beam for multiple experiments by producing pions that decay into neutrinos, muons, and other particles. Magnetic horns—the primary pion focusing elements in the NuMI beamline—exhibit predominantly linear optics, enabling a predictable relationship between the proton beam and the resulting pion and muon phase spaces. This study has two primary objectives: first, to evaluate and confirm the linearity of the horn focusing mechanism using analytical models and numerical simulations; and second, to demonstrate that key beam parameters—such as proton beam intensity, beam position on target, and horn current—can be extracted from muon monitor observations within this linear optics framework. Using a machine learning model trained on spill-by-spill muon monitor data, we infer the horn current with a precision of ±0.05%, the beam intensity with ±0.1%, and the beam position on target with ±0.018⁢ mm horizontally and ±0.013⁢ mm vertically. This approach provides a reliable cross-check of beam parameters, helping to reduce systematic uncertainties that are critical for future experiments such as the Deep Underground Neutrino Experiment, which will rely on the neutrino beam produced by the Long-Baseline Neutrino Facility.

Beam control↗