Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAMMALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Bone Marrow Nails Created by Percutaneous Osteoplasty for Long Bone Fracture: Comparisons Among Acrylic Cement Alone, Acrylic-Cement-Filled Bare Metallic Stent, and Acrylic-Cement-Filled Covered Metallic Stent

Purpose: This study was designed to compare the strength among bone marrow nails created to treat long bone fractures using interventional procedures. Methods: Twelve resected intact tibiae of healthy swine were used. A circumferential bone fracture was made in nine tibiae and restored with the following created bone marrow nails: acrylic cement alone (ACA) (n = 3), acrylic-cement-filled bare metallic stent (AC-FBMS) (n = 3), and acrylic-cement-filled covered metallic (AC-FCMS) stent (n = 3). The remaining intact tibiae (n = 3) were used as controls. Results: A bone marrow nail was successfully achieved within 30 min in all swine. The maximum injection volume of acrylic cement for creating ACA, AC-FBMS, and AC-FCMS was 1.7 {+-} 0.3, 3.2 {+-} 0.4, and 2.9 {+-} 0.4 mL, respectively. The thickness of bone marrow nail created in the ACA, AC-FBMS, and AC-FCMS groups was 3.6 {+-} 1.0, 10.3 {+-} 0.26, and 9.6 {+-} 0.32 mm, respectively (AC-FBMS group versus AC-FCMS group, p = 0.038), probably because of leakage of acrylic cement surrounding the interstices. The maximum bending power (kilonewton) and bending strength (newton/mm{sup 2}) in the normal long bone, ACA, AC-FBMS, and AC-FCMS groups were: 1.70 {+-} 0.25 and 79.2 {+-} 16.1; 0.21 {+-} 0.11 and 8.8 {+-} 2.8; 0.46 {+-} 0.06 and 18.2 {+-} 1.6; and 0.18 {+-} 0.04 and 7.8 {+-} 2.7, respectively. Conclusions: Although the maximum bending power and bending strength of AC-FBMS were not satisfactory, it was the most robust of the three marrow nails for restoring fractured long bone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Seven-Year, Single-Centre Experience of the Long-Term Outcomes of Bovine Ureter Grafts Used as Novel Conduits for Haemodialysis Fistulas

Purpose: To report the long-term outcomes of bovine ureter grafts as novel conduits for haemodialysis fistulas. Materials and Methods: Thirty-five patients underwent placement of a total of 40 SynerGraft 100 (SG100; CryoLife Europa{sup Registered-Sign}, Guildford, UK) bovine ureter grafts between April 2002 and February 2009. Prospective data were collected on all patients, including active surveillance with blood flow studies and 6-monthly duplex ultrasound studies. Main outcome measures were primary and secondary patency rates. Results: Mean follow-up time was 97 weeks (range 4-270). Thirteen patients died from unrelated causes during the study period; 12 of these patients had a functioning graft at the time of death. Five patients underwent transplantation, and all had a functioning graft at transplantation. Twelve patients had a functioning graft at the end of the study period. One hundred and ten stenoses were detected, and 97 venoplasty procedures were performed. Of the stenoses, 41.8% were located at the venous anastomosis, 12.7% within the graft, 17.3% in the outflow veins, and 28.1% in central veins. No arterial stenoses were detected. Primary patency rates were 53% at 6 months and 14% at 1 year. Secondary patency rates were 81% at 6 months, 75% at 1 year, and 56% at 2 years. Conclusions: Active surveillance and intervention was able to achieve satisfactory long-term secondary patency for these novel conduits compared with those made of PTFE seen in other studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

British Society of Interventional Radiology: Biliary Drainage and Stenting Registry (BDSR)

Objectives: This study was designed to audit current practice in percutaneous biliary drainage and stenting in the United Kingdom. Methods: In 2006, the British Society of Interventional Radiology set up the first web-based Biliary Drainage and Stenting Registry (BDSR). This consisted of a series of tick sheets, which were completed online. Data collection included technical and clinical success of the procedures and outcomes at discharge with a separate form for any follow-up visits. Two months before data analysis, all contributors were asked via email to complete any outstanding data. This paper reports on data collected between November 1, 2006 and August 18, 2009. Results: A total of 833 procedures were recorded and were entered by 62 operators from 44 institutions within the United Kingdom. There were 455 men and 378 women with a median age of 69 (range 20-101) years.The majority of procedures were performed by a consultant. Successful drainage of the biliary tree was achieved in 98.7%. Partial or complete relief of symptoms was seen in 65% of patients. Minor complications, predominantly pain (14.3%), were seen in 26% and major complications, predominantly sepsis (3.5%), were seen in 7.9% of patients. Conclusions: These figures provide an essential benchmark for both audit and patient information. Identifying areas of good practice and those that require improvement will ultimately result in better patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carotid Artery Stenosis at MSCT: Is there a Threshold in Millimeters that Determines Clinical Significance?

Purpose: The purpose of this work was to determine whether it is possible to identify a reliable carotid stenosis threshold-measured in millimeters (mm)-that is associated with cerebrovascular symptoms. Methods: Written, informed consent was obtained for each patient; 149 consecutive patients (98 men; median age, 68 years) were studied for suspected pathology of the carotid arteries by using MDCTA. In each patient, carotid artery stenosis was quantified using the mm-method. Continuous data were described as the mean value {+-} standard deviation (SD), and they were compared by using the Student's t test. A ROC curve was calculated to test the study hypothesis and identify a specific mm-stenosis threshold. Logistic regression analysis was performed to include other MDCTA findings, such as plaque type and ulcerations. A P value < 0.05 was considered to indicate statistical significance. Results: Twenty-six patients were excluded. Of those remaining, 75 patients suffered cerebrovascular symptoms (61%). There was a statistically significant difference (P = 0.0046) in the mm-carotid stenosis between patients with symptoms (1.31 {+-} 0.64 mm SD) and without symptoms (1.68 {+-} 0.79 mm SD). Multiple logistic regression analysis confirmed that symptoms were associated with increased luminal stenosis (P = 0.013) and with the presence of fatty plaques (P = 0.0491). Moreover, the ROC curve (Az = 0.669; {+-}0.051 SD; P = 0.0009) indicated that a threshold of 1.6 mm stenosis was associated with a sensitivity to symptoms of 76%. Conclusions: The results of our study suggest an association between luminal stenosis (measure in mm) and the presence of cerebrovascular symptoms. Luminal stenosis of 1.6 mm is associated, with a sensitivity of 76%, with cerebrovascular symptoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing the Detectability of Hepatocellular Carcinoma by C-Arm Dual-Phase Cone-Beam Computed Tomography During Hepatic Arteriography With Conventional Contrast-Enhanced Magnetic Resonance Imaging

Purpose: To evaluate the sensitivity of dual-phase cone-beam computed tomography during hepatic arteriography (CBCTHA) for the detection of hepatocellular carcinoma (HCC) by comparing it with the diagnostic imaging 'gold standard': contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver. Materials and Methods: Eighty-eight HCC lesions (mean diameter 3.9 {+-} 3.3 cm) in 20 patients (13 men, mean age 61.4 years [range 50 to 80]), who sequentially underwent baseline diagnostic liver CE-MRI and then underwent early arterial- and delayed portal venous-phase CBCTHA during drug eluting-bead transarterial chemoembolization, were evaluated. Dual-phase CBCTHA findings of each tumor in terms of conspicuity were compared with standard CE-MR images and classified into three grades: optimal, suboptimal, and nondiagnostic. Results: Seventy-seven (mean diameter 4.2 {+-} 3.4 cm [range 0.9 to 15.9]) (93.9%) of 82 tumors were detected. Sensitivity of arterial-phase (71.9%) was lower than that of venous-phase CBCTHA (86.6%) for the detection of HCC lesions. Of the 82 tumors, 33 (40.2%) and 52 (63.4%), 26 (31.7%) and 19 (23.2%), and 23 (28%) and 11 (13.4%) nodules were classed as optimal, suboptimal, and nondiagnostic on arterial- and venous-phase CBCTHA images, respectively. Seventeen (73.9%) of the 23 tumors that were not visible on arterial phase were detected on venous phase. Six (54.5%) of the 11 tumors that were not visible on venous phase were detected on arterial phase. Conclusions: Dual-phase CBCTHA has sufficient image quality to detect the majority of HCC lesions compared with the imaging 'gold standard': CE-MRI of the liver. Moreover, dual-phase CBCTHA is more useful and reliable than single-phasic imaging to depict HCC nodules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree; Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Repair of a Secondary Aorto-Appendiceal Fistula

Aortoenteric fistula (AEF) is an uncommon but serious complication occurring after aortic surgery and may occur at any site in the gastrointestinal tract, with the duodenum being the most common. Conventional surgical repair of secondary AEF has high mortality, whereas endovascular repair has emerged as an alternative treatment despite concerns about persistent or recurrent infection. We report the case of a 91-year old man who was admitted with rectal bleeding from an aorto-appendiceal fistula 9 years after open abdominal aortic aneurysm repair. This rare site for AEF was diagnosed on computed tomography, and we present the first case of endovascular treatment of this uncommon complication.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pre-Uterine Artery Embolization MRI: Beyond Fibroids

Uterine leiomyomata, or fibroids, although benign, cause debilitating symptoms in many women. Symptoms are often nonspecific and may be the presenting complaint in a number of other conditions. Furthermore, because the presence of fibroids may be coincident with other symptomatic conditions that result in similar complaints, there may be diagnostic difficulty and consequent difficulty in planning therapeutic strategy. Uterine artery embolization (UAE) is a safe and effective treatment for symptomatic fibroids and is increasingly being performed. Magnetic resonance imaging (MRI) evaluation before and after treatment is routine practice with the potential to significantly alter management in up to a fifth of patients. It is well recognized that significant incidental findings may be demonstrated during imaging investigations, and in particular that abnormalities that are not directly related to the clinical question may be overlooked. Radiologists evaluating pre-UAE MRI studies must be aware of the MRI appearances of gynecological pathologies that may cause similar symptoms or that may affect the success or complication rates of UAE, and they must also be wary of 'satisfaction of search,' reviewing imaging thoroughly so that relevant other pathologies are not missed. We demonstrate the appearances of coincidental pathologies found on pre-UAE MRI, with the potential to change patient management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Embolization of the Pancreas Safe? Pancreatic Histological Changes after Selective Transcatheter Arterial Embolization with N-Butyl Cyanoacrylate in a Swine Model

Purpose: This study was designed to evaluate the safety of selective transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) in a swine model in terms of histological changes in the pancreas. Methods: Three groups of two female swine (58-64 kg) per group underwent TAE of the dorsal pancreatic artery, under anesthesia, with 1:1, 1:4, and 1:9 mixtures of NBCA and iodized oil. Blood parameters were evaluated at days 1, 4, and 10 after TAE, after which the animals were sacrificed and pancreatic tissues were examined under light microscopy. Results: All of the animals were asymptomatic and survived for 10 days. Cone beam computed tomographic angiography revealed occlusion of the dorsal pancreatic artery and no enhancement in the embolized area. The white blood cell count and C-reactive protein level were elevated slightly on day 1 after TAE (mean {+-} SD: 252.7 {+-} 27.8 Multiplication-Sign 10{sup 2}/{mu}l and 0.15 {+-} 0.07 mg/l, respectively), but they normalized or remained near the upper normal limit thereafter. The serum amylase and lipase levels also were elevated on day 1 (8831.7 {+-} 2169.2 U/l and 130 {+-} 53.4 U/l, respectively) but normalized thereafter. Histologically, necrosis and fibrosis were noted only in the embolized segment, and necrosis and acute inflammatory reactions were absent in the nonembolized segment. The border between both segments was well defined. Lymphocytic infiltration and foreign body reaction were noted around the embolized vessels. Conclusions: Selective TAE with NBCA in the pancreas caused localized ischemic necrosis without clinically significant pancreatitis; therefore, this procedure is tolerable in swine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Acute Arterial Hemorrhage in Trauma Patients Using Ethylene Vinyl Alcohol Copolymer (Onyx)

Purpose: This study was designed to determine the feasibility and efficacy of endovascular embolization with liquid embolic agent ethylene vinyl alcohol copolymer (Onyx) in patients with acute traumatic arterial bleeding. Methods: This is a retrospective review of 13 patients (9 men and 4 women; mean age 45 years) with severe trauma who underwent embolotherapy using Onyx from November 2003 to February 2009. Bleeding was located in the pelvis (5 patients), kidney (3 patients), mesenteric region (2 patients), retroperitoneal space (2 patients), neck (1 patient), and thigh (1 patient). In three cases (23.1%), Onyx was used in conjunction with coils. We evaluate the technical and clinical success, procedural and embolization time, occurrence of rebleeding, and embolotherapy-related complications, such as necrosis or migration of Onyx into nontarget vessels. Results: In all patients, embolotherapy was technically and clinically successful on the first attempt. Control of bleeding could be reached with a mean time of 19 (range, 4-63) min after correct placement of the microcatheter in the feeding artery. No recurrent bleeding was detected. No unintended necrosis or migration of Onyx into a nontarget region was observed. During the follow-up period, three patients (23.1%) died due to severe intracranial hemorrhage, cardiac arrest, and sepsis. Conclusions: Transcatheter embolization with new liquid embolic agent Onyx is technically feasible and effective in trauma patients with acute arterial hemorrhage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Response and Apoptosis of N1-S1 Rodent Hepatomas in Response to Intra-arterial and Intravenous Benzamide Riboside

Purpose: Benzamide riboside (BR) induces tumor apoptosis in multiple cell lines and animals. This pilot study compares apoptosis and tumor response in rat hepatomas treated with hepatic arterial BR (IA) or intravenous (IV) BR. Methods: A total of 10{sup 6} N1-S1 cells were placed in the left hepatic lobes of 15 Sprague-Dawley rats. After 2 weeks, BR (20 mg/kg) was infused IA (n = 5) or IV (n = 5). One animal in each group was excluded for technical factors, which prevented a full dose administration (1 IA and 1 IV). Five rats received saline (3 IA and 2 IV). Animals were killed after 3 weeks. Tumor volumes after IA and IV treatments were analyzed by Wilcoxon rank sum test. The percentage of tumor and normal liver apoptosis was counted by using 10 fields of TUNEL (terminal deoxynucleotidyl transferase dUTP nick-end labeling)-stained slides at 40 Multiplication-Sign magnification. The percentage of apoptosis was compared between IV and IA administrations and with saline sham-treated rats by the Wilcoxon rank sum test. Results: Tumors were smaller after IA treatment, but this did not reach statistical significance (0.14 IA vs. 0.57 IV; P = 0.138). There was much variability in percentage of apoptosis and no significant difference between IA and IV BR (44.49 vs. 1.52%; P = 0.18); IA BR and saline (44.49 vs. 33.83%; P = 0.66); or IV BR and saline (1.52 vs. 193%; P = 0.18). Conclusions: Although differences in tumor volumes did not reach statistical significance, there was a trend toward smaller tumors after IA BR than IV BR in this small pilot study. Comparisons of these treatment methods will require a larger sample size and repeat experimentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Irreversible Electroporation Lung Ablation: Preliminary Results in a Porcine Model

Objective: Irreversible electroporation (IRE) uses direct electrical pulses to create permanent 'pores' in cell membranes to cause cell death. In contrast to conventional modalities, IRE has a nonthermal mechanism of action. Our objective was to study the histopathological and imaging features of IRE in normal swine lung. Materials and Methods: Eleven female swine were studied for hyperacute (8 h), acute (24 h), subacute (96 h), and chronic (3 week) effects of IRE ablation in lung. Paired unipolar IRE applicators were placed under computed tomography (CT) guidance. Some applicators were deliberately positioned near bronchovascular structures. IRE pulse delivery was synchronized with the cardiac rhythm only when ablation was performed within 2 cm of the heart. Contrast-enhanced CT scan was performed immediately before and after IRE and at 1 and 3 weeks after IRE ablation. Representative tissue was stained with hematoxylin and eosin for histopathology. Results: Twenty-five ablations were created: ten hyperacute, four acute, and three subacute ablations showed alveolar edema and necrosis with necrosis of bronchial, bronchiolar, and vascular epithelium. Bronchovascular architecture was maintained. Chronic ablations showed bronchiolitis obliterans and alveolar interstitial fibrosis. Immediate post-procedure CT images showed linear or patchy density along the applicator tract. At 1 week, there was consolidation that resolved partially or completely by 3 weeks. Pneumothorax requiring chest tube developed in two animals; no significant cardiac arrhythmias were noted. Conclusion: Our preliminary porcine study demonstrates the nonthermal and extracellular matrix sparing mechanism of action of IRE. IRE is a potential alternative to thermal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial and Long-Term Results of Endovascular Therapy for Chronic Total Occlusion of the Subclavian Artery

Purpose: To study the initial and long-term results of angioplasty and primary stenting for the treatment of chronic total occlusion (CTO) of the subclavian artery (SA). Materials and Methods: From January 1999 to February 2010, 56 patients (25 men with a mean age of 58 {+-} 8 years) underwent endovascular treatment for CTO of the SA. Duplex scans and arteriograms confirmed occlusion in all cases. Indications for recanalization were subclavian steal syndrome in 33 patients (58.1%), arm claudication in 13 patients (23.2%), and coronary ischemia in 7 patients (12.5%) who had a history of previous coronary artery bypass grafting that included left internal thoracic artery graft. Three patients (5.4%) were treated before the scheduled coronary artery bypass surgery, which included left internal thoracic artery graft. After successful recanalization, all arteries were stented, and all of the patients were followed-up at 1, 3, 6, and 12 months after surgery and annually thereafter. Results: Successful recanalization of the SA was achieved in 46 patients (82.1%), and the complication rate was 7.1%. During follow-up (mean 40 {+-} 26 months; range 2 to 125), the primary patency rates after 1 and 3 years were 97.9% and 82.7%, respectively. At the end of follow-up, 76% of the arteries showed no evidence of restenosis. Univariate analysis failed to identify any variable predictive of long-term patency of successfully recanalized SA. Conclusion: Percutaneous transluminal angioplasty with stenting of the complete total occlusion of the SA is a safe and effective procedure associated with low risks and good long-term results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraluminal Radioactive Stent Compared with Covered Stent Alone for the Treatment of Malignant Esophageal Stricture

Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consent was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hepatic Arterial Embolization with Doxorubicin-Loaded Superabsorbent Polymer Microspheres in a Rabbit Liver Tumor Model

Objectives: The pharmacokinetic profile after hepatic arterial embolization with superabsorbent microspheres (QuadraSpheres) loaded with doxorubicin was studied. Methods: Rabbits with hepatic VX2 tumors were treated with intra-arterial administration of QuadraSpheres loaded with doxorubicin, or transarterial chemoembolization (TACE) using doxorubicin, Lipiodol and Embospheres, or hepatic arterial infusion (HAI) of doxorubicin. Tumor specimens were evaluated by fluorescence microscopy, and plasma and tumor concentrations of doxorubicin were measured. Results: The peak plasma concentration of doxorubicin was lower in the QuadraSphere group (309.9 ng/ml) than in the HAI (673.4 ng/ml) or TACE (360.5 ng/ml) groups, suggesting higher tumor retention in the QuadraSphere group. Intratumoral doxorubicin levels declined to negligible levels at 1 and 3 days after treatment, respectively, in the HAI and TACE groups. In the QuadraSphere groups, intratumoral doxorubicin level declined after day 1, but was still detectable at 14 days after treatment and was higher than that in the other groups at 1, 3, and 7 days. Intratumoral doxorubicin fluorescence was detected at all time points in the QuadraSphere group, but only at 1 day after treatment in the TACE group. Conclusions: Hepatic arterial administration of doxorubicin-loaded QuadraSpheres enables the sustained release of doxorubicin to hepatic tumors.

60 APPLIED LIFE SCIENCES↗

Enhanced Antitumor Effect of Tirapazamine Delivered Intraperitoneally to VX2 Liver Tumor-Bearing Rabbits Subjected to Transarterial Hepatic Embolization

Purpose: We evaluated the effects of the combination of Tirapazamine (TPZ), activated preferentially under hypoxic conditions, and gelatin microspheres (GMS) on the tumor growth ratio in rabbits. Methods: We assigned 20 liver tumor-bearing Japanese white rabbits to 4 equal groups. Group 1 received 1 ml of saline intra-arterially (i.a.) and 20 ml of saline intraperitoneally (i.p.; saline group). Group 2 was injected with GMS i.a. and 20 ml saline i.p. (GMS group). Group 3 received 1 ml of saline i.a. and 300 mg/m{sup 2} of TPZ i.p. (TPZ group), and group 4 was treated with GMS i.a. and 300 mg/m{sup 2} of TPZ i.p. (GMS + TPZ group). The infusion of GMS was stopped when the blood flow stagnated. Before and 7 days after treatment, the liver tumor volumes were measured as the total number of pixels on 0.3Tesla (T) magnetic resonance imaging (MRI) scans. Results: The tumor growth ratio (mean {+-} standard deviation) of the saline, GMS, TPZ, and GMS + TPZ groups was 519.15 {+-} 93.78, 279.24 {+-} 91.83, 369.78 {+-} 95.73, and 119.87 {+-} 17.62, respectively. The difference between the GMS + TPZ group and the other groups was statistically significant (P < 0.05). Conclusions: Our results show that the combination of TPZ i.p. and GMS i.a. enhanced the antitumor effect of TPZ. This procedure may represent a new alternative treatment for patients with hepatic cell carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

Purpose: To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence. Materials and Methods: A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 {+-} 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted. Results: A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD's tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days. Conclusions: Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗