Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Superlattice Photocathode Damage Analysis

Jefferson Lab uses 100 kV DC high voltage photoguns with high polarization strained superlattice GaAs photocathodes to achieve electron beam polarization over 80%. The photocathode is subjected to back-bombardment from ionized residual gasses during operation. We present surface analyses using transmission electron microscopy (TEM) and secondary ion mass spectrometry (SIMS) to characterize photocathode damage.

36 MATERIALS SCIENCE↗

First Test Results of Superconducting Twin Axis Cavity for ERL Applications

Superconducting cavities with two beam pipes had been proposed in the past for energy recovery linac applications. The relatively complex geometry of those cavities presented a serious challenge for fabrication and surface processing. Main concerns have now been overcome with the production and successful RF testing of a new elliptical twin-axis cavity proposed by Jefferson Lab and optimized by the Center for Accelerator Science at Old Dominion University in the frame of a DoE accelerator stewardship program. The cavity design provides uniform accelerating or decelerating fields for both beams. This paper describes the cavity design, fabrication experience, and the first cold RF test results and explores potential applications especially for Jefferson Lab s EIC (JLEIC).

Park, H.-K.↗

Energy-Recovery Linacs for Commercial Radioisotope Production

Most radioisotopes are produced by nuclear reactors or positive ion accelerators, which are expensive to construct and to operate. Photonuclear reactions using bremsstrahlung photon beams from less-expensive electron linacs can generate isotopes of critical interest, but much of the beam energy in a conventional electron linac is dumped at high energy, making unwanted radioactivation. The largest part of this radioactivation may be completely eliminated by applying energy recovery linac technology to the problem with an additional benefit that the energy cost to produce a given amount of isotope is reduced. Consequently, a Superconducting Radio Frequency (SRF) Energy Recovery Linac (ERL) is a path to a more diverse and reliable domestic supply of short-lived, high-value, high-demand isotopes at a cost lower than that of isotopes produced by reactors or positive-ion accelerators. A Jefferson Lab approach to this problem involves a thin photon production radiator, which allows the electron beam to recirculate through rf cavities so the beam energy can be recovered while the spent electrons are extracted and absorbed at a low enough energy to minimize unwanted radioactivation. The thicker isotope photoproduction target is not in the beam. MuPlus, with Jefferson Lab and Niowave, proposed to extend this ERL technology to the commercial world of radioisotope production. In Phase I we demonstrated that 1) the ERL advantage for producing radioisotopes is at high energies (~100 MeV), 2) the range of acceptable radiator thickness is narrow (too thin and there is no advantage relative to other methods and too thick means energy recovery is too difficult), 3) using optics techniques developed under an earlier STTR for collider low beta designs greatly improves the fraction of beam energy that can be recovered (patent pending), 4) many potentially useful radioisotopes can be made with this ERL technique that have never before been available in significant commercial quantities. We developed a plan for the Phase II project that started with a Conceptual Design Report (CDR) based on the results of the Phase I studies and concluded with a Technical Design Report (TDR) for a facility to make isotopes that are most attractive based on market analyses.

43 PARTICLE ACCELERATORS↗

Energy-Recovery Linacs for Commercial Radioisotope Production - Phase I

Most radioisotopes are produced by nuclear reactors or positive ion accelerators, which are expensive to construct and to operate. Photonuclear reactions using bremsstrahlung photon beams from less-expensive electron linacs can generate isotopes of critical interest, but much of the beam energy in a conventional electron linac is dumped at high energy, making unwanted radioactivation. The largest part of this radioactivation may be completely eliminated by applying energy recovery linac technology to the problem with an additional benefit that the energy cost to produce a given amount of isotope is reduced. Consequently a Superconducting Radio Frequency (SRF) Energy Recovery Linac (ERL) is a path to a more diverse and reliable domestic supply of short-lived, high-value, high-demand isotopes at a cost lower than that of isotopes produced by reactors or positive-ion accelerators. A Jefferson Lab approach to this problem involves a thin photon production radiator, which allows the electron beam to recirculate through rf cavities so the beam energy can be recovered while the spent electrons are extracted and absorbed at a low enough energy to minimize unwanted radioactivation. The thicker isotope photoproduction target is not in the beam. MuPlus, with Jefferson Lab and Niowave, proposed to extend this ERL technology to the commercial world of radioisotope production. In Phase I we demonstrated that 1) the ERL advantage for producing radioisotopes is at high energies (~100 MeV), 2) the range of acceptable radiator thickness is narrow (too thin and there is no advantage relative to other methods and too thick means energy recovery is too difficult), 3) using optics techniques developed under an earlier STTR for collider low beta designs greatly improves the fraction of beam energy that can be recovered (patent pending), 4) many potentially useful radioisotopes can be made with this ERL technique that have never before been available in significant commercial quantities. We developed a plan for the Phase II project that started with a Conceptual Design Report (CDR) based on the results of the Phase I studies and concluded with a Technical Design Report (TDR) for a facility to make isotopes that are most attractive based on market analyses.

07 ISOTOPE AND RADIATION SOURCES↗

System Downtime Management at 12 GeV CEBAF

Jefferson Lab?s Accelerator Division uses two independent web based applications for Beam Time Accounting and System Downtime tracking. The Beam Time Accounting application acts as the accelerator time clock, while the Downtime Manager application monitors individual system performance. Accelerator system health is important to quantify in order to effectively and efficiently utilize limited resources for performance improvements. Jefferson Lab?s Accelerator Operability Group has historically tracked System Downtime by gathering failure data via Operator input. A recent overhaul of that process has been implemented which includes failure guidelines, a new web based application/reporting application, and Operator training. The new process was implemented at the start of CEBAF?s 12 GeV Commissioning to document system failures during commissioning, identify ?infant mortality? failures, and improve the Downtime Manager application prior to production running. This discussion will focus on the journey of implementing the modified system downtime process and the vision of future improvements for CEBAF operations.

Michaud, Randy↗

A High Power Prototype of a Harmonic Kicker Cavity

A harmonic kicker, a beam exchange device that can deflect the beam at an ultra-fast time scale (a few ns), has been developed in Jefferson Lab *, **. The high power prototype that can deliver more than a 100 kV kick at 7 kW was fabricated. The RF performance of cavity such as the harmonic resonant frequencies, kick profiles, it’s stability, and electric center is tested at bench. The cavity will eventually be tested with a beam at Upgraded Injector Test Facility (UITF) in Jefferson Lab. In this paper, we report some features of fabrication and bench test results. We also briefly describe our beam test plan in the future.

Park, Gunn↗

Summary of performance of superconducting radio-frequency cavities built from CBMM niobium ingots

Several Nb ingots have been provided by CBMM to Jefferson Lab since 2004 as part of an R&D collaboration aimed at evaluating the performance of superconducting radio-frequency cavities built from ingots with different purity, as a results of different ingot production processes. Approximately 32 multi- and single-cell cavities with resonant frequency between ∼1.3-2.3 GHz were built, treated and tested at 2 K at Jefferson Lab between 2004 and 2014. The average peak surface field achieved in cavities made of RRR∼260 and RRR∼100-150 ingots was (119 ± 4) mT and (100 ± 8) mT, respectively. Higher quality factor values at 2.0 K have been measured in medium-purity, compared to higher purity material.

43 PARTICLE ACCELERATORS↗

Measurement of the Neutron Radius of 208 Pb Through Parity Violation in Electron Scattering

In contrast to the nuclear charge densities, which have been accurately measured with electron scattering, the knowledge of neutron densities still lack precision. Previous model-dependent hadron experiments suggest the difference between the neutron radius, R n , of a heavy nucleus and the proton radius, R p , to be in the order of several percent. To accurately obtain the difference, R n -R p , which is essentially a neutron skin, the Jefferson Lab Lead ( 208 Pb) Radius Experiment (PREX) measured the parity-violating electroweak asymmetry in the elastic scattering of polarized electrons from 208 Pb at an energy of 1.06 GeV and a scattering angle of 5° . Since Z 0 boson couples mainly to neutrons, this asymmetry provides a clean measurement of R n with respect to R p . PREX was conducted at the Jefferson lab experimental Hall A, from March to June 2010. The experiment collected a final data sample of 2x 10 7 helicity-window quadruplets. The measured parity-violating electroweak asymmetry A PV = 0.656 ± 0.060 (stat) ± 0.014 (syst) ppm corresponds to a difference between the radii of the neutron and proton distributions, R n -R p = 0.33 +0.16 -0.18 fm and provides the first electroweak observation of the neutron skin as expected in a heavy, neutron-rich nucleus. The value of the neutron radius of 208 Pb has important implications for models of nuclear structure and their application in atomic physics and astrophysics such as atomic parity non-conservation (PNC) and neutron stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Q weak experimental apparatus

The Jefferson Lab Q weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was created for this experiment to meet the technical challenges presented by the smallest and most precise e → p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 μA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Møller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8° and 11.6° were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cherenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q 2 =0.025 GeV 2 was observed using dedicated low-current ( ~ 100 pA ) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hadronization Studies via π 0 Electroproduction off D, C, Fe, and Pb

Propagation of partons and formation of hadrons is a topic of interest to multiple communities. New data available from Drell-Yan measurements at FermiLab, heavy ion collisions in RHIC and LHC, SIDIS measurements from HERMES at DESY and Jefferson Lab, all bring different types of information on short distance processes. DIS data obtained in the well understood nuclear medium provide direct information on hadron formation, essential to lay the groundwork for testing theoretical tools. A series of semi-inclusive DIS measurements were performed on D, C, Fe, Pb nuclei. The data were collected during the EG2 run period using the CLAS at Jefferson Lab. A double-target system consisting of liquid deuterium and one of the solid targets was exposed to a 5.014 GeV electron beam. The goal of the experiment is to extract hadronic multiplicity ratios (R$h\atop{A}$) off nuclei of varying size. These are believed to have sensitivity to the parton fragmentation as well as in-medium hadronization.

Mineeva, Taisiya↗

PhytoPET, PhytoBeta and PhytoSPECT: Radioisotope Imaging Systems Being Developed for Plant Biology Research

The Radiation Detector and Imaging Group at Thomas Jefferson National Accelerator Facility (Jefferson Lab) is developing radioisotope imaging systems designed and constructed to facilitate plant biology studies at the Duke University Phytotron. The imaging systems utilize nuclear medicine imaging methodologies used in positron emission tomography (PET) and single photon emission computed tomography (SPECT) but designed specifically for plant biology. The range of plant shapes and the environmental conditions in plant growth chambers pose a technological challenge. Description: Jefferson Lab is collaborating with the Duke University Phytotron and the Triangle Universities Nuclear Laboratory (TUNL) in the construction and operation of PhytoPET and PhytoBeta (for direct beta particle detection) for plant and/or microbe imaging. The TUNL tandem Van de Graaff accelerator (maximum terminal voltage of 10 MV) has been used to generate 11C and 13N for plant biology research. The PhytoPET and PhytoBeta have been used with 11C as a 11CO2 tracer for plant ecophysiology imaging with corn, poplar, oak and barley utilizing technologies developed for nuclear physics research and nuclear medicine. The imaging detectors are based on position sensitive photomultiplier tubes coupled to scintillators. Additionally, the collaboration is investigating a methodology using single photon emitting radioisotope tracers for imaging the distribution of molecular compounds of interest in the rhizosphere, the interface between root and soil, without disturbing the root or soil habitat. Plans are underway to develop a single photon emission computed tomography (SPECT) system (PhytoSPECT) to image the bio-distribution of fungi in association with a host plant's roots. In addition to a description of the technology an overview will be given of the application of PhytoPET, PhytBeta and PhytoSPECT to plant biology research at Duke University. Conclusions: We have developed and used radioisotope imaging technologies based on PET and SPECT to visualize plant function in changing environments. There are many opportunities to provide radioisotope based imaging tools for plant ecophysiology imaging. Keywords: radioisotope detection, plant biology, carbon-11, accelerator produced isotopes

Weisenberger, Andrew↗

Exotic Hybrid Meson Spectroscopy with the GlueX detector at Jlab

The GlueX experiment is scheduled to begin taking data in 2015. The goal is to discover evidence for the existence of exotic hybrid mesons and to map out their spectrum in the light quark sector. Recent theoretical developments using Lattice QCD predict exotic hybrid states in a mass range accessible using the newly upgraded 12GeV electron accelerator at Jefferson Lab. Hybrid mesons, and in particular exotic hybrid mesons, provide the ideal laboratory for testing QCD in the confinement regime since these mesons explicitly manifest the gluonic degrees of freedom. The experiment will use 9 GeV linearly polarized photons produced via coherent bremsstrahlung to produce the exotic hybrids. The decay products will be detected in the solenoid-based GlueX detector currently under construction at Jefferson Lab. The status of the GlueX experiment including detector parameters will be presented along with theoretical motivation for the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Meson Spectroscopy at CLAS and CLAS12

We report on meson spectroscopy using the CLAS at Jefferson Lab. We study photo-production of exotic mesons and strangeonia on the largest data sample ever to be produced at photon energies of about 5 GeV. We also describe an experiment to continue meson spectroscopy at CLAS12 (CLAS energy upgrade) using electroproduction at very low Q{sup 2}(''quasireal photons'') up to photon energies of 10 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The structure of the nucleon: Elastic electromagnetic form factors

Precise proton and neutron form factor measurements at Jefferson Lab, using spin observables, have recently made a significant contribution to the unraveling of the internal structure of the nucleon. Accurate experimental measurements of the nucleon form factors are a test-bed for understanding how the nucleon's static properties and dynamical behavior emerge from QCD, the theory of the strong interactions between quarks. There has been enormous theoretical progress, since the publication of the Jefferson Lab proton form factor ratio data, aiming at reevaluating the picture of the nucleon. We will review the experimental and theoretical developments in this field and discuss the outlook for the future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Metastability exchange optical pumping of 3 He at low pressure and high magnetic field

We report systematic studies on metastability exchange optical pumping of 3 He nuclei have been performed at Jefferson Lab using a 1-torr sealed cell at magnetic fields from 2 to 4 T. The effects of the discharge intensity, pump laser power and pumping transition schemes on achievable nuclear polarization and pumping rate have been investigated. A maximum steady-state nuclear polarization of about 75% has been obtained. This work provides a baseline for the development of the novel polarized 3 He target for CLAS12 at Jefferson Lab.

47 OTHER INSTRUMENTATION↗

Short-Distance Structure of Nuclei

One of Jefferson Lab's original missions was to further our understanding of the short-distance structure of nuclei. In particular, to understand what happens when two or more nucleons within a nucleus have strongly overlapping wave-functions; a phenomena commonly referred to as short-range correlations. Herein, we review the results of the (e,e'), (e,e'p) and (e,e'pN) reactions that have been used at Jefferson Lab to probe this short-distance structure as well as provide an outlook for future experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High-Magnetic-Field Polarized 3He Target for JLab's CLAS12 Spectrometer

We are developing a polarized 3He target for use in high luminosity electron scattering experiments within the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping (MEOP) of 3He with cryogenic, double-cell target methods as used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic field environments. We have begun polarizing sealed 3He cells at fields up to 5 T at Jefferson Lab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target. A key focus of our research is the determination of polarization relaxation under the irradiation of an ionizing particle beam within high magnetic fields.

Maxwell, James↗